Home
Sagem 155C User's Manual
Contents
1. 11 RB Output for data extracted from STM 1 line and sampled on the RE eee RSR EC E Bone Receive mode byte sync output indicating the setting of bit 1 and pq ROFPA sent on the falling edge of clock T64 B A rc LL BLL Rea LO 14 Tu 64 kHz transmit clock output pu __ ot comected 5 oo L8 BE j GOemnd 9 Timing diagram for the EOW AUX interface in contra directional mode 64 kbit s synchronous use T64 B A transmit clock output input for data to transmit l l over STM1 line l l TOFP B A transmit synchro byte pulse output R64 B A receive clock output R B A output for data received B8 C Bo Y B2 from STM1 line ROFP B A receive synchro byte pulse output Installation and User Guide N56717020101 Page A1 14 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING 1 3 3 3 Connecting with MSP operation As EOW and AUX ports are physically integral with ADR IC1 x operating the order wire and auxiliary channels with MSP protection requires the use of a Y cord electrically connecting one by one identically the signals of EOW and AUX connectors ADR IC1 x Working ADR IC1 x Protection Y cord for Y cord for order wire auxiliary wire channel operation channel operation Likewise in order to ensure a good be
2. TEST LOCAL Inventaire du mat riel Contr le des alimentation 48 V Bouclage optique des r sultants Insertion des param tres de communication VT100 i i i i i Mise l heure et insertion de la configuration de test des acc s affluents i i navigateur HTTP i l i Contr le de continuit des acc s affluents Contr le de redondance du 48 V Contr le des alarmes et des boucles A et B Test local de la transmission 30 mn cas d un quipement unitaire sous quip Raccordement optique Raccordement de l entr e de synchronisation externe d un quipement maitre optionnel Elaboration de la configuration Test local du dernier quipement sur le r seau non oui Mesures optiques V rification de la protection MSP Raz des compteurs Qualit 24 H en liaison Equipement op rationnel constitution du dossier d installation Sauvegarde de la configuration Figure 1 8 Processus de mise en service d un r seau d ADR155C Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 19 1 INSTALLATION ET MISE EN SERVICE 1 4 Mise en service NOTA L exploitation de l quipement peut tre r alis e a partir d un PC quip d une emulation VT100 et du navigateur HT
3. eS 1 O O O Siolo o D Local equipment Remote indication 1 Non alarmed Remote indication 2 Non alarmed Remote indication 3 major Remote indication A minor spem gt 3213821381383 S S o N ewe eem mum 0 RO lui A Op Remote equipment Far user inputs Remote indication 1 Major Far user inputs Hemote indication 2 Minor H H N A Card configuration major Defective card major lt lt lt D D D ep W o o Missing Table 2 10 Alarms severity 2 2 Ifthe equipment configured is declared centre site Installation and User Guide N56717020101 Page A2 14 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Correlation of faults A correlation mechanism is implemented on all faults detected This correlation mechanism implemented on each change of information collected is used to eliminate faults induced by other faults to facilitate fault finding and fault locating The following tables define the faults that are masked for each fault detected in the system column For example The LOF fault is masked by fault 2 LOS Key The fault concerned on the current line is masked by the fault in the current Correlation of STM1 faults FAULTS r LOS LOF ge B2 LOF AIS MS
4. Voyants STATUS 1 OUTPUT et E4 INPUT 30 OO OOOOOOOOOOOOO 16 Allum Eteint Carte en service 44 Allum Allum Carte en alarme Eteint Eteint D faut mat riel de la carte fusible Eteint Allum Carte hors service Toca Clignotant D faut autotest 1 Tx Rx 1A 17 Tx Rx 2B 31 Tx Rx 1B 2 Tx Rx 3B 18 Tx Rx 32 Tx Rx 2A Tx Rx 4A 19 Tx Rx 5B 33 Tx Rx 4B 4 Tx Rx 6B 20 Tx Rx 6A 34 Tx Rx 5A 5 Tx Rx 7A 21 Tx Rx 8B 35 Tx Rx 7B 6 Tx Rx 9B 22 TX Rx 9A 36 Tx Rx 8A 7 Tx Rx 10 23 Tx Rx 11B 37 Tx Rx 10B 8 Tx Rx 128 24 Tx Rx 12A 38 Tx Rx 11A 9 Tx RX 13 25 Tx Rx 14B 39 Tx Rx 13B 10 Tx Rx 15B 26 Tx Rx 15 40 Tx Rx 14A 11 TX RX 16 27 Tx Rx 17B 41 Tx Rx 16B 12 Tx Rx 18B 28 Tx Rx 18B 42 Tx Rx 17A 13 TX RX 19 29 Tx Rx 20B 43 Tx Rx 19B 14 TX RX 21B 30 Tx Rx 21 44 Tx Rx 20A 15 GND Figure 1 6 Raccordement sur le module ADR 21E120 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 17 1 INSTALLATION ET MISE EN SERVICE 1 3 6 Bandeau de raccordement 75 Q R daction r serv e Figure 1 7 Bandeau de raccordement 75 Q Guide d Installation et d Utilisation N56717020101 Page B1 18 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE
5. is the result of a logical OR between signals OB1 OB2 on the PWR PWRA PWRB power supply interfaces ETH Interface Port Ethernet management interface operating at 10 Mbit s in half duplex or full duplex mode according to the mode used by the interlocutor dynamic adaptation of the Ethernet port on each new log in of the interlocutor Connector RJ48 Type RJ45 shielded Pin 1 Pin 8 Front view ww Swamme Comm _ Output hot poing Output cold point input hot point input cold Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 7 1 INSTALLATION AND COMMISSIONING NOTE Two LEDs are linked to the ETH port e LED Activity green colour Trafic status indicator LED Link yellow colour Link status indicator 1 3 2 2 Management and Administration ports COMM Interface Ports RS232 connecting VT100 standard console or emulation Bit rate 19200 bauds 8 data bits no parity bit and 1 stop bit Connector Female 9 way HE5 9 6 000 0 ome seme TE ES WE DCD Connected to DSR e DSR Data Set Ready to DCE L2 FX Received data to DCE EBENEN WE ME RTS Request To Send from DCE ND CE EN Transmitted data from DCE Le a CTS Clear To Send to DCE DTR Data Terminal Ready from DCE Ro o Ring Indicator not connected 5 T 7 GND Ground The ADR15
6. On Off On On Off Off Hardware default on card fuse Off On Card out of service not configured Flashing Seft est default gt Pushbuttons Designation Location Role Action initiated ACK Front panel Alarm Pressing disables the outgoing alarm acknowledge loops The visual alarm is kept INIT Motherboard Configuration Factory Configuration reload CONFIG reload To activate INIT keep button pressed for at least 5 seconds This button is inaccessible and unused in normal operation It is necessary to remove the cover to access it Installation and User Guide N56717020101 Page A2 12 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Defaults and Alarms The tables below give the default values of severity associated with the failures Description Severity o Pl SDH Physical Interface O Loss Of Signal Major 71 f T Transmit Fail Major RST Regenerator Section Termination LOF Loss Of Frame Major MST Multiplex section Termination Bit Error Rate gt 10 on B2 Byte major Signal Degrade B2 minor Alarm Indication Signal Non alarmed lt G D e SIE gt 59 0 UJ N Remote Defect Indication minor MSP Multiplex Section Protection PAM Protection Architecture Mismatch SCM Selector Control Mismatch OTM Operation Type Mismatch MSA Multiplex Section Adaptation AU AIS AU LO
7. near end working protection RS multiplex section byte B2 near end working protection MS VC3 tributary paths near end Low Path Virtual Container VC12 tributary paths byte V5 near end Low Path Virtual Container for the remote equipment multiplex section byte M1 far end working protection MS VC3 tributary paths far end Low Path Virtual Container VC12 tributary paths byte V5 far end Low Path Virtual Container Performance processing includes the following functions calculation of the number of errored blocks or bit errors on local and remote faults and monitoring of the appearance faults over a one second period VC12 REI indicators are not taken into account in the calculation calculation and determination of the ES Errored Second SES Severely Errored Second BBE Background Block Error and UAS UnAvailable Second states for each monitoring point generation for each monitoring point of 15 minute counters and 24 hour counters BBE ES SES and UAS Determination of ES SES and UAS performance states For each of the monitoring points the following states are ES Errored Second number of seconds with at least one error detected in a 1 s period or one fault SES Severely Errored Second number of severely errored seconds An SES is a second for which the number of errors exceeds a defined threshold or during which at least one fault is detecte
8. toutes les cartes de l quipement 1 Mettre la carte concern e hors service partir du navigateur HTTP 2 Retirer les raccordements externes effectu s sur la face avant de la carte NOTA Lorsque les fibres optiques externes sont d connect es remettre en place les capots de protection des connecteurs 3 D visser les vis TORX situ es en face avant l aide du tournevis adapt et d senficher la carte 4 Extraire la carte en respectant les mesures de protection contre les d charges lectrostatiques NOTA Pour toute manipulation de carte l op rateur doit tre quip d un bracelet anti statique bien serr au poignet et reli la terre 5 Conditionner la carte dans un sachet anti statique 6 Sortir la nouvelle carte de son sachet anti statique 7 Ins rer avec pr caution la carte dans son alv ole en respectant les mesures de protection contre les d charges lectrostatiques et la fixer avec les vis TORX 8 R tablir les raccordements en face avant de la carte NOTA Pour la carte STM1 optique retirer les capots de protection des connecteurs Pour nettoyer les connecteurs optiques utiliser une bombe d air sous pression 9 Configurer la carte si n cessaire et la mettre en service Remplacement du module ventilateur Le module ADRFAN est compos de deux ventilateurs redondants afin d assurer une ventilation suffisante lors d une d faillance de l un d entre eux Les pannes des ventilateurs
9. 48V 60W de la source primaire d alimentation D visser le porte fusible en face avant de l alimentation Remplacer le fusible d fectueux par un fusible quivalent savoir Fusible 4A rapide HA214A Dimensions longueur 20mm 0 5 diam tre 5 2 mm 0 1 0 2 Revisser le porte fusible Heconnecter le cordon d alimentation ou le transformateur 110 240 48V 60W sur la source primaire d alimentation Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 21 2 EXPLOITATION Guide d Installation et d Utilisation N56717020101 Page B2 22 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 3 RECHANGES 3 RECHANGES ADR155C ch ssis 19 Ch ssis ADR155C AM101333 Module de ventilation ADRFAN AM101360 Adaptateur 22 x 75 ohms 1 0 2 3 19 ETSI AM101901 Carte d acces Acc s STM1 optique IC1 1 ADR IC1 1 AM101328 Acc s STM1 optique IC1 2 ADR IC1 2 AM101329 Acc s Ethernet 10 100 ADR LAN AM101331 Acces 21 x 2Mbit s 120 ohms ADR 21E120 AM101330 Boitier externe Transformateur 110 240 48V 60W AM101669 Logiciel Liste des cordons disponibles Acces SYNC 251 008 309 Synchronisation 251 008 312 251 008 320 291 008 333 Acc s E1 INPUT ou E1 OUTPUT Et ou St 21x2Mbit s sur carte mere ou ADR21E120 Et ou ST 21x2 Mbit s 120 ohms SUBD 55 6 0 741 55 670 742 55 670 743 55 670 74
10. LPOM Surveillance de pr fixe de conduit d ordre inf rieur Lower Order path Overhead Monitor SD B3 Signal d grad calcul partir des octets B3 mineure VC3 Signal Degrade B3 SD B2 Signal d grad calcul a partir des octets B2 mineure VC12 Signal Degrade B2 LO RDI Indication d alarme distante sur conduit d ordre mineure inf rieur Low order Path Remote Defect Indication LO UNEQ Etiquette du conduit d ordre inf rieur non quip n ant Low order Path Unequipped LPT Terminaison de conduit d ordre inf rieur Lower order Path Termination SD V5 Signal d grad calcul a partir des V5 mineure VC12 Signal Degrade V5 SD B3 Signal d grad calcul partir des octets B3 mineure VC3 Signal Degrade B3 LO SLM n ant Erreur sur l tiquette du signal de conduit d ordre inf rieur Low order Path Signal Label Mismatch LO RDI Indication d alarme distante associ e au conduit mineure d ordre inf rieur Low order Path Remote Defect Indication e D z LO UNEQ Etiquette du conduit d ordre inf rieur non quip n ant Low order Path Unequipped LPA Adaptation de conduit d ordre inf rieur Lower order Path Adaptation LO SLM Erreur sur l tiquette du signal de conduit d ordre n ant inf rieur Low order Path Signal Label Mismatch Tableau 2 10 Alarmes et gravit 2 3 Guide d Installation et d Utilisation N56717020101
11. PWR ou PWRA et ou PWRB Sur le bandeau de la carte m re du ch ssis acces de gestion COMM ETH et ou MNGT acc s de t l signalisation de t l commandes et d alarmes station LOOPS acc s de synchronisation 2Mbit s G 703 SYNC acces de trafic 21x2Mbit s G 703 E1 INPUT et E1 OUTPUT selon les modules d acc s utilis s acces STM 1 optiques et acces des voies de service acces Ethernet acces de trafic 21x2Mbit s G 703 Regles de raccordement gt 1 3 1 Pour une bonne r partition des cordons de part et d autre du ch ssis les raccordements des alv oles A et C les 21 acc s 2Mbit s et l acc s de synchronisation sont orient s vers la gauche Tous les autres raccordements sont orient s vers la droite Le passage des cordons ne doit pas g ner l extraction d un module en particulier les c bles de raccordement de la moiti gauche du ch ssis doivent tre assujettis au b ti avec un mou suffisant afin de permettre l extraction du module de ventilation lors d une op ration de maintenance Raccordement de l alimentation Acc s PWRA et ou PWRB lorsque l quipement est aliment partir d une ou deux source s 48 V la ou les sources s d alimentation doit doivent tre limit e s 100 VA Acces PWR lorsque l quipement est aliment partir d une tension r seau 230 V CA via un transformateur 110 240 48V 60W optionnel R gles de raccordement respecter
12. Page B2 14 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Alarmes D nomination Gravit Interface physique PDH PDH Physical Interface PPI LOS Perte de signal mineure Loss Of Signal AIS oignal d indication d alarme N ant Alarm Indication Signal SETS Source de rythme de l quipement synchrone Synchronous Equipment Timing Source T3 LOS Perte de signal sur l entr e de synchro T3 mineure T1LOS Perte de signal sur l entr e de synchro T1 n ant T2 LOS Perte de signal sur l entr e de synchroT2 n ant T4 D faut sur la sortie de synchronisation T4 mineure Failure Equipement local Local user T l signalisation 1 n ant inputs 1 Local user T l signalisation 2 n ant inputs 2 Local user T l signalisation 3 majeure inputs 3 Local user T l signalisation 4 mineure inputs 4 Equipement distant Far user T l signalisation 1 Majeur inputs 1 Far user T l signalisation 2 Mineure inputs 2 Card configuration majeure Message Defective card majeure Message Missing card majeure Tableau 2 11 Alarmes et gravit 3 3 Si l quipement configur est d clar site central Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 15 2 EXPLOITATION Corr lation des d fauts Un traitement de corr lation est r alis sur l ense
13. Proto Cost 4 2 2 2 2 4 2 2 2 2 2 2 24 2 24 2 4 4 020 000 000 000 255 000 000 000 020 000 000 010 020 000 000 000 255 000 000 000 030 000 000 001 other dir 255 255 255 255 255 255 255 2553 127 255 251 223 inull other other t toggle route filter up d page down INTERFACES Eort tatus subnet mask ip of dest Path 8OH RIP 4 R R R R R 020 000 000 010 255 000 000 000 ON DOWN 030 000 000 001 255 000 000 000 000 000 000 000 MNGT ON OFF OFF OFF 00 06 59 connect wT100 9600 DH D fi Mai Num Capturer Imprimer l cho Cet cran permet de visualiser la table de routage de lister les routes dynamiques et ou statiques ainsi que la configuration des interfaces Choix 4 REBOOT de l quipement Cette commande permet d effectuer un REBOOT imm diat de l application et de red marrer avec les param tres d j m moris s dans l quipement Choix 5 Logout D connexion Le param trage termin cette commande ferme la session en cours Une sortie de session automatique est effectu e apr s quelques minutes de non activit d lai param trable partir du gestionnaire Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 25 1 INSTALLATION ET MISE EN SE
14. au milieu en rouge si n cessaire les modules en alarme encadr s en rouge dans le cas d une alarme majeure en jaune pour une alarme mineure e les modules configur s hors surveillance sont repr sent s en gris Les modules configur s hors service comportent une croix pour signaler cet tat administratif Guide d Installation et d Utilisation N56717020101 Page B1 26 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE Cet cran permet galement d activer les fonctionnalit s communes de l quipement telles que la synchronisation la s curit les informations de trafic etc en cliquant sur une fonction de la barre de menu voir arborescence du menu g n ral Figure 1 10 d acc der aux fonctionnalit s li es un module en particulier par exemple protection MSP dans le cas d un module ADRIC1 x double click sur le module s lectionner la fl che de s lection clignote et son menu sp cifique apparait voir arborescence des menus carte Figure 1 10 de visualiser les caract ristiques propres un acc s connexions effectu es configuration de celles ci tat des alarmes en s lectionnant le connecteur correspondant Pour chaque fonction visualis e les param tres de configuration les commandes d exploitation les param tres actifs et l tat des alarmes sont regroup s sur le m me cran les diff rentes actions possib
15. deux quipements types On note que chaque port de la fonction de routage embarqu e correspond un SUBNET diff rent Sch ma d un exemple d architecture de RGT 140 1 1 3 140 1 0 2 140 1 0 3 140 1 1 2 Ethernet 128 1 0 1 Ethernet 12811 0 3 NET 128 1 NET 140 1 Ee 1501 02 7 em Fibre Ethernet e E NET 160 1 NET 150 1 Configuration de l ADR155C F6 Interfaces IP Ether 128 1 0 3 Masque Ether 255 255 0 0 IP STM1 150 1 0 2 Masque STM1 255 255 255 0 IP X21 P 0 0 0 0 Interface non mise en service Masque X21 P 0 0 0 0 Routes statiques Dest IP Subnet mask Next hop Interface Metric Remarque 140 1 0 0 255 255 0 0 128 1 0 2 e 1 Tout le NET 140 1 150 1 1 0 255 255 255 0 150 1 0 3 S 1 Tout le SUBNET 155 1 1 Guide d installation et d utilisation N56717020101 Page BA 4 Reproduction et communication interdites sans autorisation crite de SAGEM SA ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP A3 Configuration de l ADR155C F8 Interfaces IP Ether 150 1 1 3 Masque Ether 255 255 255 0 IP STM1 0 0 0 0 Interface non mise en service Masque STM1 0 0 0 0 IP X21 P 0 0 0 0 Interface non mise en service Masque X21 P 0 0 0 0 Routes statiques Dest IP Subnet mask Next hop Interface Metric Remarque 128 1 0 0 255 255 0 0 150 1 1 2 e 2 Tout le NET 128 1 140 1 0 0 255 255 0 0 150 1 1 2 e 3 Tout le NET 140 1 150 1 0 0 255 255 255 0 150 1 1 2 e 1 Tout le SUBNET 155 1 0 Uti
16. management ports COMM ETH and or MNGT e Remote indication remote control and station alarm port LOOPS 2Mbit s G 703 synchronization port SYNC e 21x2Mbit s G 703 traffic ports E1 INPUT and E1 OUTPUT Depending on the traffic modules used e Optical STM 1 ports and order wire channels ports e Ethernet port e 21x2Mbit s G 703 traffic ports Connection requirements For a right distribution of cords on either side of the subrack the connections of slots A and C the 21 2Mbit s accesses and synchronization access are oriented leftward All other connections are oriented leftward gt The run of cords must not hinder the extraction of a module in particular connecting cables of the left subrack half is to be secured to the frame with enough backlash to enable the ventilation module to be extracted during a maintenance operation 1 3 1 Connecting Power Supply e PWRA and or PWRB ports when the equipment is powered from one or two 48 V sources the power source s should be limited to 100 VA PWR port when the equipment is powered from a mains voltage 230 V AC via an optional 110 240 48V 60W transformer Observe the following connection requirements gt PWR and PWRA and or PWRB Power supply ports can be connected simultaneously gt The power cord or the 110 240 48V 60W transformer must not be connected to the primary source prior to being connected to the equipment
17. rer Edin Ave Aree Torsten 7 Diel cxi scies ei EC mrswiuums Bain MATI FATIT EUTE3 Fa nent hom Bin PETI deem a add coute coute w aramsas couts B DE 3C connects 3n 84 1 Murs L cran visualise les routes de gestion d j d finies avec leurs caract ristiques No r f rence de la route destination 9 IP adresse IP du destinataire quipement ou sous r seau subnet mask masque de sous r seau next hop Q IP adresse IP de l quipement suivant connect en direct avec l quipement donn interface interface utilis e pour atteindre l quipement suivant cost ou metric nombre de bonds pour atteindre le destinataire Guide d Installation et d Utilisation N56717020101 Page B1 24 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE A partir de cet cran il est possible de modifier les routes existantes de les supprimer ou d en creer de nouvelles le routage statique est n cessaire si des FOT155C sont pr sents dans le r seau ou pour une interconnexion avec un sous r seau voisin Choix 3 Affichage des informations de routage adr155 HyperT erminal Iofs Fichier Edition Affichage Appel Transf rer 7 oel es SPACE refresh ESC previous main menu RIP ROUTING TABLE Page 1 1 destination 1 subnet mask next hop Aip Intf
18. 1 Using the HTTP navigator see 1 4 3 e Update the equipment time and date Set each card under monitoring validate the Monitoring command Connect the 2 Mbit s and or Ethernet ports according to the equipment composition Connect the AUX and EOW ports required Download a predefined configuration or prepare the desired configuration using the HTTP navigator Create the connections Establish the wished protection MSP protection SNC protection Choose the synchronization source and change its parameters if required Change if necessary the configuration parameters and the alarm configuration The default configuration of the various parameters is provided by 2 1 1 Conduct the tests on STM 1 links complying with the process described in Figure 1 2 From that moment the equipment is operational Operating alarms can signal a wrong connection of interfaces Check the connection of ports the alarms corresponding to the connected ports and correct any problems that may arise Save configuration REMARK It is possible once the commissioning is performed to connect additional 2 Mbit s G 703 Ethernet or STM1 ports and to insert or extract powered cards Installation and User Guide N56717020101 Page A1 20 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING Mngt port Application SEH HTTP server RI SNNP f Point to Point
19. 22 Tx Rx 9A 36 Tx Rx 8A 7 Tx Rx 10 23 Tx Rx 11B 37 Tx Rx 10B 8 Tx Rx 128 24 Tx Rx 12 38 Tx Rx 11A 9 Tx RX 13 25 Tx Rx 14B 39 Tx Rx 13B 10 Tx Rx 15B 26 Tx Rx 15 40 Tx Rx 14A 11 TX RX 16 27 Tx Rx 17B 41 Tx Rx 16B 12 Tx Rx 188 28 Tx Rx 18B 42 Tx Rx 17A 13 TX RX 19 29 Tx Rx 20B 43 Tx Rx 19B 14 TX RX 21B 30 Tx Rx 21 44 Tx Rx 20 15 GND Figure 1 6 Connecting ADR 21E120 card inputs Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 17 1 INSTALLATION AND COMMISSIONING 1 3 6 75 connecting strip Drafting TBD Figure 1 7 75 2 connecting strip Installation and User Guide N56717020101 Page A1 18 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING LOCAL TEST Equipment Inventor 48 V power Check Aagregate optical loopback Insertion of communication parameters VT100 Setting to time and insertion of the test configuration tributary accesses HTTP browser Tributary Ports continuity check 48 V redundancy Check A and B loops and alarms check case of underequipped unitary equipment Local transmission test 30 mn Optical connection Connection of external sync input from of an Master equipment optional Configuration Elaboration no Local Test on
20. 3 gt PFPP3 4 FrPP 7 W WI S nam Ha Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 23 1 INSTALLATION AND COMMISSIONING The screen displays the 5 communication interfaces possible with their characteristics and proposes to change each of them by turns These interfaces are an Ethernet port ETH 4 PPP Point to Point Protocol portes PPP1 to PPP4 to be chosen from the following management paths either at bytes D1 to D3 of channel DCC1 of an STM1 frame named DCC1 A DCC1 B DCC1 C or DCC1 D according to the number and position of ADR IC1 x modules in the equipment or the MNGT interface Each interface is defined by its characteristics Port physical port ETH PPP1 to PPP4 Admin or interface state ON interface active or OFF interface inactive IP IP address subnet mask subnetwork mask IP of dest destination IP address for PPP ports only Path management path chosen for the PPP ports DCC1x or MNGT RIP management routing self adaptability to the network structure validated or not limited to 16 hops without gateway The parameterization is backed up port by port Choice 2 Configuration of static routes FIDE uiu Enter den Aren Sepe Dundee 7 Piae exi scies ei d pasa up d page deem coute mimodify cout
21. 3 remote links totalling 3 VC3 used This equipment is managed from a HTTP navigator either locally via its dedicated Ethernet interface or remotely by teleoperation or from the IONOS ANM network manager in this last case using the SNMP protocol also allows global network supervision Using a local terminal with VT100 emulation is necessary on the first commissioning for the configuration of communication parameters Management network connections are performed via DCC D1 to D3 or D4 to D12 of the STM1 or on Ethernet ETH or P MNGT interfaces of the equipment The ADR155C is placed in 19 racks or ETSI frames It consists of a 2U subrack fitted with a motherboard grouping together the basic functions of the equipment a backplane and a secured 48V DC power supply an ADRFAN module consisting of two redundant ventilation units four traffic cards C1 1 or 1 1 2 STM1 optical card ADR 1C1 1 or ADR 1C1 2 card allowing a VC4 connection or 3 VC3 connections or 63 VC12 connections or a combination of VC3 VC12 connections e 21x2Mbit s card G 703 ADR21E120 card allowing 21 VC12 connections Ethernet 10 100 card LAN1 ADR card allowing 2 VC3 connections Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 1 1 INSTALLATION AND COMMISSIONING OK OQ ADR 155C Subrack Left uprights of rack ADR 155C ETSI RACK 19
22. 31 Installation and User Guide N56717020101 Page A1 10 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING t o Jgornd 3 _ p Tq 2 32 TX RX 2A Output input 2 Mbit s cold point 2 3 o de TX RX3A 133 4 TX RX 4B Output Input 2 Mbit s hot point 3 T4 5 TXRX5B J 4 o J TX RX 6A 15 7 5 l __ TX RX 8B 899 8 o Jz TX RX 9A s n 7 J3 n Ex 118 o I8 8 2 oo qa TX RX 12A 15 9 125 14 TX RX 14B Output Input 2 Mbit s hot point o 4 po 15 o iz TX RX 15A Ja 16 Hj j _ 1 17 TX RX 17B Output Input 2 Mbit s hot point o l Je 12 J 9 T28 TX RX 18A Output input 2 Mbit s cold point 9 19 129 20 TX RX 20B Output Input 2 Mbit s hot point o l Ja 1 4 21 TXR9 18 __ 35 OD Ground O NOTA The shielding of the connector case is connected to the subrack front panel ground Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 11 1 INSTALLATION AND COMMISSIONING STM 1 transmission port STM 1 reception port DR IC1 T D T TATUS EOW a
23. 75 75 75 Fax 33 1 55 75 31 91 http www sagem com Si ge social 6 rue d l na 75783 PARIS CEDEX 16 FRANCE S A au capital de FRF 210 502 900 562 082 909 RCS PARIS
24. ETPJ 4d FrPP 7 TE conecte Ganen Mum ware ura Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 23 1 INSTALLATION ET MISE EN SERVICE L cran pr sente les 5 interfaces de communication possibles avec leurs caract ristiques et propose de modifier chacune d elles tour tour Ces interfaces sont un acc s Ethernet ETH 4 acc s PPP Point to Point Protocole PPP1 PPP4 choisir parmi les chemins de gestion suivants soit aux octets D1 D3 du canal DCC1 d une trame STM1 appel s DCC1 A DCC1 B DCC1 C ou DCC1 D selon le nombre et la position des modules ADR IC1 x dans l quipement soit l interface MNGT Chaque interface est d finie par ses caract ristiques Port port physique ETH PPP1 PPP4 Admin ou tat de l interface ON interface active ou OFF interface non active IP adresse IP subnet mask masque de sous r seau IP of dest adresse IP du destinataire pour les ports PPP uniquement Path chemin de gestion choisi pour les ports PPP DCC1x ou MNGT RIP autoadaptativit du routage de gestion la structure du r seau valid e ou non limit e 16 bonds sans passerelle La sauvegarde du param trage s effectue port par port Choix 2 Configuration des routes statiques e abi Hager
25. No Monitoring Monitoring If EBER B2 is not monitoring AIS SF and MS RDI consequent actions are inhibited SD B2 threshold configurable from 10 to 10 SD B2 threshold MSP Multiplex Section Protection Link type 1 0 or 1 1 Protection mode bi directional unidirectional Mode BIDIR Revertive authorization return after a WTR time delay to the working link when the fault SF or SD causing the switch has disappeared Revertive Table 2 1 Configuration parameters 1 6 Installation and User Guide N56717020101 Page A2 2 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Configuration parameters per functional blocks Default value MSP Multiplex Section Protection suite Wait Time to Restore WTR period in revertive mode period following restoration of nominal operation configurable from O to 15mn in one second steps WTR SF SD priority according to Recommendation G 783 1994 annex A 1 2 1 possible value high or low compatibility with MXA Sf sd priority SF and SD fault persistence configurable from 0 to 10s in 100ms steps Hold off time HPOM Higher order path overhead monitor Signal label expected and received byte C2 of VC4 path overhead Label Expected possible values 01H equipment not specified or 02H TUG mode structure Received HPT Higher Order Path Termination Signal la
26. RBR 9 Sortie donn es extraites de la trame STM 1 et mises sur le front descendant de l horloge R64 B A 12 Sortie synchro octet en r ception indiquant le positionnement du bit 5 nor o 1 et mise sur le front descendant de l horloge R64 B A Re B 9 Sortie horloge de r ception 64 kHz LS R4 LO 4 TB Sortie horloge d mission 64 kHz ZJ TA jo Non connect Chronogramme de l interface EOW AUX en mode contra directionnel utilisation synchrone 64 kbit s T64 B A sortie horloge d mission entr e donn es transmettre l l sur la ligne STM1 l l TOFP B A sortie synchro octet en mission R64 B A sortie horloge de r ception R B A sortie donn es re ues B8 lt Y B2 de la ligne STM1 l l l l ROFP B A sortie impulsion de trame en r ception Guide d Installation et d Utilisation N56717020101 Page B1 14 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE 1 3 3 3 Raccordement avec exploitation MSP Les acc s EOW et AUX tant physiquement solidaires des modules ADR 1C1 x l exploitation des voie de service et voie auxiliaire avec protection MSP n cessite l utilisation d un cordon en Y reliant lectriquement un un l identique les signaux des connecteurs EOW et AUX ADR IC1 x Working ADR IC1 x Protection Cordon en
27. SUBRACK Two M6x12 Two M6x12 HM screw HM screw Two M6 Two M6 cage nuts cage nuts 19 rack mounting ETSI rack mouting Figure 1 1 ADR155C Subrack Installation Installation and User Guide N56717020101 Page A1 2 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING 1 2 Subrack installation The ADR 155C subrack can be installed in 19 rack or ETSI frame see Figure 1 1 It consists of motherboard located in the lower part item M e four non dedicated slots items to D designed to accommodate the traffic cards e slide located the left of the subrack designed to accommodate the ventilation module item V a power supply item P All connections are performed on front panel either on the subrack or on the modules Installation in a 19 rack Elements attaching the subrack in 19 rack brackets cage nuts and attaching screws are provided in its package The ADR155C has a system of thermal control by ventilation during the installation provide for sufficient space for the ventilation aperture on the left of the subrack and also for the aeration at the top and right of the subrack On the other hand never hinder the natural air convection on the right side Perform the following operations provide a 20 place in the rack for each equipment and a 1U space between equipments Secure the attaching brackets for mounting i
28. Y Cordon en Y pour exploitation pour exploitation de la voie de service de la voie auxiliaire De m me pour garantir un bon comportement lors du basculement d un module sur l autre l op rateur doit veiller conserver une configuration identique sur les deux cartes ADR IC1 x un message d avertissement apparait en cas de modification Seules les connexions ne sont pas identiques Il ne doit pas y avoir de connexions sur le module en Protection toutes les connexions tant cr es sur le module Working Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 15 1 INSTALLATION ET MISE EN SERVICE 1 3 4 Raccordement sur le module ADR LAN1 DR LAN1 STATUS 10 100 HALF FULL ETH Voyants STATUS HALF FULL Vert Rouge Voyant jaune nature de l interface Allum Eteint Carte en service Ethernet Allum Allum Carte en alarme Half ou Full Duplex Eteint Eteint D faut mat riel de la carte fusible Eteint Allum Carte hors service Allum Full duplex Clignotant D faut autotest 10 100 Contact 1 Contact 8 Voyant jaune d bit sur l interface Ethernet 1 TX ETH 5 NC 2 TX ETH RING 6 RX_ETH_RING Allume 100 Mbit s ETH 7 NC 4 NC 8 NC NC R serve Voyant jaune Etat de la liaison Allum Liaison correcte Voyant vert Etat du trafic Allum R ception en cours Figure 1 5 Raccordement sur le mo
29. an equivalent fuse namely 4A quick break fuse HA214A Dimensions length 20mm 0 5 diameter 5 2 mm 0 1 0 2 Screw the fuse holder Reconnect the power cable or the 110 240 48V 60W transformer to the primary power source Installation and User Guide N56717020101 Page A2 20 No reproduction or communication without the written consent of SAGEM SA 3 SPARE PARTS 3 SPARE PARTS Designation ADR155C 19 subrack ADR155C subrack AM101333 Fan module ADR FAN AM101360 Adaptator 22 x 75 ohms 1 0 2 3 19 ETSI AM101901 Traffic card IC1 1 STM1 optical card ADR IC1 1 IC1 2 STM1 optical card ADR IC1 2 Ethernet 10 100 card ADR LAN 21 x 2Mbit s 120 ohms card ADR 21E120 External transformer Transformer 110 240 48V 60W Available cable list SYNC port 251 008 309 Synchronization 251 008 312 251 008 320 251 008 333 E1 INPUT or E1 OUTPUT port 21x2Mbit s In or Out on motherboard or ADR21E120 Et or ST 21x2 Mbit s 120 ohms SUBD 55 670 741 55 670 742 55 670 743 55 670 744 21x2 Mbit s 75 ohms 1 0 2 3 55 670 582 right cable 55 670 583 55 670 584 55 670 585 Installation and User Guide N56715070103 No reproduction or communication without the written consent of SAGEM SA Page A3 1 3 SPARE PARTS Available cable list continue MNGT port 1 5 m 55 670 655 P management between two ADR 155C 3 m 55 670 656 COMM port 1 8 m 4 980 214 VT100 Management port ETH port Ethernet port on mother board o
30. are coded over 4 bytes and are usually represented in decimal form e g 135 11 33 115 An IP address is divided into 3 fields e the NET field on the left e the subnet field in the center e the host field on the right The length of the first field depends on the class to which the address belongs The length of the subnet and host fields is defined by a mask associated with the address There are three address classes e class A the NET field is coded over the first byte the three other bytes are reserved for the SUBNET and HOST fields class A addresses vary from 1 0 0 0 to 126 255 255 254 e class B the NET field is coded over the first two bytes the two other bytes are reserved for the SUBNET and HOST fields class B addresses vary from 128 0 0 0 to 191 255 255 254 e class C the NET field is coded over the first three bytes the last byte is reserved for the SUBNET and HOST fields class C addresses vary from 192 0 0 0 to 223 255 255 254 the maximum number of equipment pieces that can belong to the same class C IP network having the same NET is 254 Note Addresses starting with 127 and addresses including all 1 or all O in the SUBNET and HOST fields are not permitted Note The IP standard authorizes that the SUBNET and HOST fields can be coded over a number of bits that does not correspond to an byte border usually this is not implemented for reasons of address legibilit
31. gt The 110 240 48V 60W transformer must be mounted far from any heat source and no traction must be exerted on its connecting wires Installation and User Guide N56717020101 Page A1 4 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING Description of power supply ports PWR Jack type connector FAAL250V Fuse 4A Quick fuse low power shutdown 250V PWRA and PWRB 1 48 2 48 Bi 6 OB1 3 Reserved 7 OB1 4 48 B2 8 OB2 5 48 B2 9 OB2 ADR 155C Figure 1 2 Connecting power supply ports PWRA PWRB power supply interface Input voltage One or two Safety Extra Low Voltage SELV type 48V sources Voltage range allowed 36 V to 60 V Maximum voltage range 36 V to 72 V Power 100 VA maximum Connector Male 9 way HE5 48B1 48B1 NOTA The shielding of the connector is connected to the equipment ground PWR power supply interface Port Connecting transformer 110 240 48V 60W Connector Jack core OB1 and shield 48 V1 Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 5 1 INSTALLATION AND COMMISSIONING IO OQ OO 15 0 0 0 0 0 0 0 9 Break B Make B 9 Common B Common A 10 Break A Gnd 11 Make A J O O1 O ND SYNC R MON AN 12 R MON 4 P OB R MON 3 N 13 R MON 3 P OB 5
32. impos ou auto adaptatif la connexion s lection du d bit maximal propos sur le bus half ou full duplex Contr le du flux LAN vers VC3 1 60 96 VC3 i vers VC3 j ou LAN 60 96 Tableau 2 3 Param tres de configuration 3 6 Guide d Installation et d Utilisation Nb6717020101 Page B2 4 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Param tres d exploitation en fonction des blocs fonctionnels d faut Module ADRLAN suite Configuration des interfaces LAN en service hors service Service Age maximum du routage 300 s Path trace J1 mis UNNAMED UNNAMED VC3 CRC7 non configurable et non trait en r ception VC3 CRC7 SETS Source de rythme de l quipement synchrone Synchronous Equipment Timing Source Niveau de qualit des sources de synchronisation Quality PRC Primary Reference Clock SSUT Synchronisation Supply Unit Transit T3 PRC T1 SSMB SSUL Synchronisation Supply Unit Local T2 SEC SEC Synchronisation Equipment Clock DNU Do Not Use SSMB Synchronisation Status Message Byte qualit de synchronisation transport dans l octet 51 Utilisation des messages d tat de synchronisation SSM Synchronisation otatus Message SSM Table de priorit de TO fonction des sources d clar es 1 pour toutes valeurs possibles 1 8 les sources T4 SEC N d
33. or ETSI 300 mm 6 kg approx Corresponding to the IP of the rack used Consumption lt 40 W to a equipped subrack of two cards ADR IC1 x and two cards ADR LAN L gt Environmental specifications ETS 300 119 4 19 or CEI 297 3 ETSI ETS 300 019 2 3 Climatic conditions CEI 721 1 1993 ETS300 019 part 1 3 class 3 1 3 2 Operating temperature range 5 Ca 45T Extended operating temperature 25 C to 55 C the MTBF Mean Time Between Failure is significantly degraded Packaged transportation and 40 C to 70 C storage temperature Relative humidit lt 85 ESD NF EN 50081 1 NF EN 50082 1 June 1992 and ETS 300 386 1 1994 Electromagnetic Compatibility NF EN 55022 1994 Additive A1 02 1996 equipment Class B NF EN 60950 and UTE C 92130 the equipment does not provide the fire envelope ETS 300132 2 is VLV equipment a lt 5 z S 2 O D lt O ITI CD sl a 2 lt lt Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A4 1 4 SPECIFICATIONS Predicted reliability Motherboard 3 4 10 The predicted reliability computations are based on the CNET s 1993 issue RDF 93 of the Reliability Data Manual on the assumption of specific requirements for the following ambient temperature 25 C with ventilation conditions such as the subrack internal middle temperature is less than 40 C environment mount
34. page down INTERFACES Eort tatus subnet mask ip of dest Path 80H RIP 020 000 000 010 255 000 000 000 030 000 000 001 255 000 000 000 000 000 000 000 MNGT 00 06 59 connect T100 9600 DH D fi Mai Num Capturer Imprimer l cho This screen is used to view the routing table to list the dynamic and or static routes and also the interface configurations Choice 4 equipment REBOOT This command is used to perform immediate application REBOOT and to restart with the parameters already stored in the equipment Choice 5 Logout With the parameterization being complete this command closes the current session An automatic session exit is performed after a few minutes of inactivity time parameterizable from the manager Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 25 1 INSTALLATION AND COMMISSIONING 1 4 3 Using HTTP navigator 1 4 3 1 First commissioning Start the NESCAPE application On the Welcome screen fill in the Address field with the IP address of the ADR155C equipment e WARNING With NESCAPE 4 5 the equipment IP address should include no non significant 0 Example http 135 11 9 30 instead of http 135 11 09 30 The navigator welcome screen Welcome to the ADR155C s site appears On the first commissioning the password is empty click on Apply to access ADR155C sh
35. sont d tect es sur la carte mere par surveillance du courant consomm elles sont visualis es dans l cran d accueil ADR155C shelf view du navigateur HTTP si au moins un des deux ventilateurs est en panne le module ADRFAN est encadr en rouge alarme majeure non configurable NOTA le fonctionnement du module ADRFAN n est pas permanent son d clenchement est li la temp rature interne de l quipement Le module ADRFAN est extractible il peut tre remplac tout moment sans perturbation du trafic Guide d Installation et d Utilisation N56717020101 Page B2 20 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Proc dure 1 D visser les vis TORX situ es en face avant l aide du tournevis adapt et d senficher le module 2 Extraire la carte en respectant les mesures de protection contre les d charges lectrostatiques NOTA Pour toute manipulation de carte l op rateur doit tre quip d un bracelet anti statique bien serr au poignet et reli la terre Conditionner le module dans un sachet anti statique Sortir le nouveau module de son sachet anti statique Ins rer avec pr caution le module dans son emplacement en respectant les mesures de protection contre les d charges lectrostatiques et le fixer avec les vis TORX Remplacement du fusible de face avant Procedure 1 D connecter le cordon d alimentation ou le transformateur 110 240
36. transformateur 110 240 48V 60W Connecteur Jack me OB1 et blindage 48 V1 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 5 1 INSTALLATION ET MISE EN SERVICE SYNC eer 9NO O O O 6 GND TX1_TIP 6 TX1 RING RX1_TIP 7 RX2 RX2 RING 8 RX1 RING RESERVED 9 RESERVED O A N E1 OUTPUT et E1 INPUT 30 OOOOOOOOOOOOOOO 16 44 O0000000000000 31 16 GND 1 Tx Rx 1A 17 Tx Rx 2B 31 Tx Rx 1B 2 Tx Rx 3B 18 Tx Rx 32 Tx Rx 2A Tx Rx 4A 19 Tx Rx 5B 33 Tx Rx 4B 4 Tx Rx 6B 20 Tx Rx 6 34 Tx Rx 5A 5 Tx Rx 7A 21 Tx Rx BB 35 Tx Rx 7B 6 Tx Rx 9B 22 Tx Rx 9A 36 Tx Rx 8A 7 Tx Rx 10 23 Tx Rx 11B 37 Tx Rx 10B 8 Tx RX 12B 24 Tx Rx 12 38 Tx Rx 11A 9 Tx RX 13 25 Tx Rx 14B 39 Tx Rx 13B 10 Tx Rx 15B 26 Tx Rx 15 40 Tx Rx 14A 11 TX RX 16 27 Tx Rx 17B 41 Tx Rx 16B 12 Tx Rx 188 28 Tx Rx 18B 42 Tx Rx 17A 13 Tx Rx 19A 29 Tx Rx 20B 43 Tx Rx 19B 14 TX RX 21B 30 Tx Rx 21 44 Tx Rx 20A 15 GND MNGT 9 C O O 0 6 COMM 1 GND 2 RXPA 6 RXPB 7 2000 4 TXCLKPA 8 TXCLKPB GE SES 5 RXCLKPA 9 RXCLKPB 3 TX 7 RTS 4 DIR 8 CTS 5 Gnd 9 NC 8 GO e 10 15 060 44 15 0 O 0 O O O 0 9 J O O1 O ND Clignotant Eteint Vo
37. 0 O O O R MON 2 N 14 R MON 2 P OB 9 0 O O 0 6 R MON 1 N 15 R MON 1 P OB 1 GND Schematic diagram 2 TX1 TIP 6 TX1 RING of a dry loop 3 RX1 7 RX2_TIP 4 RX2 RING 8 RX1_RING 5 RESERVED 9 RESERVED E1 OUTPUT and E1 INPUT O00000000000000 1 0000000000000000 16 0060000000000000 31 16 GND 15 Green ON LED On In service card Flashing Autotest default 4 X H X 1 Tx Rx 1A 17 Tx Rx 2B 31 Tx Rx 1B Off No powered equipment 2 Tx Rx 3B 18 Tx RX 32 Tx Rx 2A or not run software Tx Rx 4A 19 Tx Rx 5B 33 Tx Rx 4B 4 Tx Rx 6B 20 Tx Rx 6 34 Tx Rx 5A 5 Tx Rx 7A 21 Tx Rx 8B 35 Tx Rx 7B ALA LEDs 6 Tx Rx 9B 22 Tx Rx 9A 36 Tx Rx 8A Red M LED 7 Tx Rx 10 23 Tx Rx 11B 37 Tx Rx 10B ON major alarm 8 Tx RX 128 24 Tx Rx 12 38 Tx Rx 11A Yellow m LED 9 13A 25 Tx Rx 148 39 Tx Rx 13B OFF minor alarm 10 Tx Rx 15B 26 Tx Rx 15 40 Tx Rx 14A 11 TX RX 16 27 Tx Rx 17B 41 Tx Rx 16B ACK Push button 12 TX Rx 188 28 Tx Rx 18B 42 Tx Rx 17A alarm acquittement 13 Tx Rx 19A 29 Tx Rx 20B 43 Tx Rx 19B 14 TX RX 21B 30 Tx Rx 21 44 Tx Rx 20 ETH 15 GND Pin 1N Pin8 v vw MNGT 1 TX ETH 5 NC p Aa 2 TX ETH RING 6 RX ETH RING 3 ETH 7 NC 99 9 0 0 6 COMM 4 NC 8 NC 1 GND 2 RXPA 6 RXPB Yellow LED link status 3 TXPA 7 9NO O 0 6 ON correct link 4 TXCLKPA
38. 000000 31 Guide d installation et d Utilisation N56717020101 Page B1 10 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE END Masse BS L Lo qz 2 __ EC 2 J res pe TX RX3A _ 15 4 3 LL L pe LJ 5 rose a J J eae dJe TX RX 6 15 7 pq ER Ss RER EN Lp o ESS CEE WE Lo del TX RX 9A _ v EMI D __ J t Dap 158 s J 2 TX RX 12 L J 8 9 _ des J 14 pp TX RX 14A po _ 26 Lp 16 16 1 1 Lo 7 p 7 1 TX RX 17 12 se _ L 8 19 TXRX1B Ds qp 2 TX RX 20 J 7 LG 480 T Sortie Entr e 2 Mbit s point froid 15 Ov Mase NOTA Le blindage du connecteur est reli la masse lectrique de la face avant du ch ssis Guide d Installation et d Utilisation Nb6717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 11 1 INSTALLATION ET MISE EN SERVICE Acc s STM1 mission Acc s STM1 r ception ADR IC1 peo ATUS gets EOW et AUX Voyants STATUS 8 1 00000000 Allum Eteint Carte en service 1 NC Allum Allum Carte en alarme 2 9 TB Eteint Eteint D faut mat riel de la carte fusible 3 j TOE PA 10 TOF PB Eteint Allum Carte hors service 4 11 RB Clignotant D faut autotes
39. 0101 No reproduction or communication without the written consent of SAGEM SA Page A2 7 2 OPERATION Maintenance operation commands Monitoring commands according to the functional blocks SPI SDH Physical Interface 2s laser restart on operator action 9s laser restart on operator action Line loopback enabled disabled transparent type Equipment loopback enabled disabled transparent type MSP Multiplex Section Protection Operator command for MSP protection Clear Lockout of Protection Forced Switch to Working Forced Switch to Protection Manual Switch to Working Manual Switch to Protection LPC Lower order Path Connection Operator command for SNC protection of VC12 or VC3 path per path and in order of priority Clear Lockout of Protection Forced Switch to Working Forced Switch to Protection Manual Switch to Working Manual Switch to Protection PPI PDH Physical Interface Line loopback enabled disabled transparent type Equipment loopback enabled disabled transparent type ADRLAN Card LAN statistics VC3 i statistics Flow control Interface status SETS Synchronous Equipment Timing Source Protection operator command Clear Lockout of Protection Forced Switch Manual Switch to Protection Table 2 7 Commands 1 2 Installation and User Guide N56717020101 Page A2 8 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Monitoring commands according to the functional blocks su
40. 105 S 5 5 D D Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B4 1 4 CARACTERISTIQUES TECHNIQUES Fiabilit pr visionnelle 3 4 10 Module ventilateur Les calculs de fiabilit pr visionnelle ont t effectu s partir du Recueil de Donn es de fiabilit du CNET dition 1993 RDF 93 dans des hypoth ses de temp rature ambiante de 25 C dans des conditions d a ration telles que la temp rature moyenne interne au ch ssis ne d passe pas 40 C d environnement au sol fixe et prot g de qualification et d ges des composants bien pr cises Toute modification de ces hypoth ses peut entra ner des r sultats diff rents Le module ventilateur fonctionne pas permanence mais seulement pour temp rature ambiante lev e TRANSFORMATEUR 110 240 48V 60W OPTION Dimensions hors c ble et prise L x x H 132 mm x 58 mm x 30 mm Temperature de fonctionnement 0 40 C Temp rature de stockage 20 C 85 Tension d entr e Fr quence d entr e Tension de sortie Protections lectroniques Normes EN60950 et UL CSA Guide d installation et d Utilisation N56717020101 Page B4 2 Reproduction et communication interdites sans autorisation crite de SAGEM SA ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEA
41. 4 21x2 Mbit s 75 ohms 1 0 2 3 55 670 582 cordon droit 55 670 583 55 670 584 55 670 585 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B3 1 3 RECHANGES Liste des cordons disponibles suite Acc s MNGT 1 5 m 55 670 655 Management P entre deux ADR 155C 3 m 55 670 656 Acc s COMM 1 8 m 4 980 214 Acc s de gestion VT100 Acc s ETH Acc s Ethernet sur carte m re ou module ADRLAN1 Cordon droit male m le 55 670 421 Cordon droit m le m le 55 670 422 Cordon crois m le male 55 670 610 Cordon droit m le femelle 55 670 423 Cordon droit m le femelle 55 670 424 Acc s LOOPS 6 013 628 Boucles d alarmes GTR et t l signalisation 6 013 261 6 013 161 6 013 262 Acc s TR ou REC 6 491 366 Jarreti re optique FC PC FC PC sur carte 6 491 367 ADRIC1 x 6 491 369 6 491 370 6 491 371 6 491 372 55 670 481 95 670 495 55 670 752 Acces AUX ou EOW 6 013 632 Acc s auxiliaire et voie de service sur carte 6 013 266 ADRIC1 x 6013 176 6 013 267 Guide d Installation et d Utilisation N56717020101 Page B3 2 Reproduction et communication interdites sans autorisation crite de SAGEM SA 4 CARACTERISTIQUES TECHNIQUES 4 CARACTERISTIQUES TECHNIQUES Caract ristiques optiques EQUIPEMENT IC1 1 L1 1 S1 1 ou IC1 22 L1 2 51 2 155 520 Mbit s 20 ppm UIT T G 957 G 958 Non cod NRZ Monomode 1300 nm 1C1 1 o
42. 50 1 ADR155C F6 Configuration Interfaces Ether IP 128 1 0 3 Ether Mask 255 255 0 0 STM1 IP 150 1 0 2 STM1 Mask 255 255 255 0 X21 P IP 0 0 0 0 Interface not put into service X21 P Mask 0 0 0 0 Static routes Dest IP Subnet mask Next hop Interface Metric Remark 140 1 0 0 255 255 0 0 128 1 0 2 e 1 All the NET 140 1 150 1 1 0 255 255 255 0 150 1 0 3 S 1 All the SUBNET 155 1 1 Installation and User Guide N56717020101 Page AA 4 No reproduction or communication without the written consent of SAGEM SA A3 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN ADR155C F8 Modification Interfaces Ether IP 150 1 1 3 Ether Mask 255 255 255 0 STM1 IP 0 0 0 0 Interface not put into service STM1 Mask 0 0 0 0 X21 P IP 0 0 0 0 Interface not put into service X21 P Mask 0 0 0 0 Static routes Dest IP Subnet mask Next hop Interface Metric Remark 128 1 0 0 255 255 0 0 150 1 1 2 e 2 All the NET 128 1 140 1 0 0 255 255 0 0 150 1 1 2 e 3 All the NET 140 1 150 1 0 0 255 255 255 0 150 1 1 2 e 1 All the SUBNET 155 1 0 Use of RIP routing demon RIP is a routing demon which makes it possible to dispense with part of the static routing tables The network must be divided into AUTONOMOUS SYSTEMS or AS each with a different NET number Each AS is an RIP routing domain and must be limited to a length of 15 hops max between two equipment pieces requiring to exchange packets within this AS The maximum distance is taken into ac
43. 5C is seen as DCE Connection cable See below Equipment side VT100 or PC COMM side Male 9 way connector Female 9 way connector Wiring diagram Installation and User Guide N56717020101 Page A1 8 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING MNGT Interface Port V 11 synchronous differential interconnection possible with other SAGEM equipment ADR155C FOT 155C through serial synchronous links used in codirectional mode at 64 kbit s or master contra directional mode rate defined by the ADR 155C Bit rate 64 kbit s Connector Female 9 way HE5 9 6 O 0 Polarity Comments no connected RXPB Input for data received over the P interface and sampled on the RER RXPA rising edge of receive clock RXCLKP B A 7 opp H Output for data sent over the P interface on the falling edge of RE E 8 TXCLKPB Output for transmit clock in codirectional mode the transmit clock 1xcLKPA _ timing is derived from the equipment s internal timing 5 RXCLKPB 9 Receive clock input _ 5 E O In slave contradirectional mode coming TXCLK signals are inputs Timing diagram for the MNGT interface in codirectional mode 64 kbit s synchronous use TXCLKP B A codirectional transmit clock output TXP B A output Tor data transmitted B8 B2 over P i
44. 8 TXCLKPB E Seen Green LED traffic status 5 RXCLKPA 9 RXCLKPB c E ON on reception 4 DIR 8 CTS 5 Gnd 9 NG NC Reserved Figure 1 3 Connecting mother board inputs Installation and User Guide N56717020101 Page A1 6 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING 1 3 2 Connecting on motherboard 1 3 2 1 Remote indication remote control and station alarm port LOOPS LOOPS Interface Ports 4 remote indication inputs for floating contacts Local user inputs biased to 48 V internally active when closed and with electrical isolation loop current from 1 to 10 mA 2 dry loop outputs common normally closed and normally open Local user outputs for station alarm or remote control use maximum current 100 mA on resistive load Connector Female 15 way HE5 00000200 mw s9wamm Comm _ 1 BREAKB Normally closed contact of dry loop B 9 COMMON B Common contact of dry loop B 2 MAKEB Normally open contact of dry loop B 10 Breaka Normally closed contact of dry loop A COMMONA Common contact of dry loop A ___ 9 Make A Normally open contact of dry loop A GND God ___ 12 RMON4P O8 _ User imput N 4 EE 15 R MON3P OB Userimput 2 ___ 14 RMON2P OB Userimput N2 EE T ___ 15 OB User imput N EE 7 ________
45. A Page B2 11 2 EXPLOITATION 2 5 Traitement des alarmes Voyants et boutons poussoirs Les tableaux ci apr s donnent les significations de l activation des voyants et les cons quences suite la mise en oeuvre des boutons poussoirs gt Voyants Organe Appellation Couleur Signification surveill Carte mere ON Vert Fixe Carte en service Clignotant D faut autotest Eteint Equipement non aliment ou logiciel non d marr ALA M Rouge Fixe Alarme majeure ALA m acc s de gestion Eteint Pas de trafic Eteint Absence de liaison STATUS Voir tableau ci apr s gt Voyants STATUS sur les cartes ADR IC 1 x ADR LAN et ADR 21E120 Signification Carte en service et en alarme D faut mat riel de la carte fusible Carte hors service non configur Clignotant D fautauttest __ gt Boutons poussoirs Appellation Localisation R le Cons quence la mise en oeuvre ACK Face avant Acquittement L appui d sactive les boucles d alarmes des alarmes sortantes L alarme visuelle est maintenue INIT Carte m re Rechargement Rechargement de la configuration CONFIG configuration constructeur a Pour mettre en uvre le bouton poussoir INIT appuyer dessus pendant 5 secondes minimum Ce bouton poussoir est inaccessible et inutilis en exploitation normale La depose du capot est n cessaire pour son accessibilite Guide d Installation et d Util
46. AIS LR SNS NS RE EE 6 RDI MS RDI le Ell ee Correlation of AU faults The AU faults are masked by the STM1 LOS LOF and AIS MS AIS faults The TU LOM fault is filtered if there is no configured VC12 connection on this STM1 FAULTS FAULTS E al LOF ups Ei E Cou AU AIS AU LOP SES EE EE _ 3 UNEQ VC4UNEQ X X RDI VC4 RDI LOX X j X L SM C Dp X X X 1 7 6 TU LOM E XY Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 15 2 OPERATION Correlation of TU VC faults TU AIS LP UNEQ LP RDI and LP SLM are masked by the STM1 LOS LOF and AIS MS AIS faults and by the AU AU LOP AU AIS UNEQ VC4 UNEQ and TU LOM faults TU LOP is masked by the AU SLM and TU LOM faults Tu AIS and TU LOP faults of a not connected input are filtered FAULTS FAULTS m UP UNE NE i LP resm ios as Correlation of port faults FAULTS FAULTS os as Correlation of remote faults LO REI LO RDI HO REI and HO RDI faults of unidirectional connection input are filtered Installation and User Guide N56717020101 Page A2 16 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION 2 6 Performance processing Performance processing consists in supervising the following monitoring ports for local equipment regeneration section byte B1
47. COMPACT 155 Mbit s ADD DROP MULTIPLEXER MULTIPLEXEUR ADD DROP a 155 Mbit s COMPACT ADR 155C Installation and User Guide Guide d Installation et d Utilisation N56717020101 Issue April 2000 Edition Avril 2000 SAGEM COMPACT 155 Mbit s ADD DROP MULTIPLEXER MUL TIPLEXEUR ADD DROP 155 Mbit s COMPACT ADR 155C Installation and User Guide Guide d Installation et d Utilisation N56717020101 Issue April 2000 Edition Avril 2000 LIST OF CHANGES REPERTOIRE DES MISES JOUR A new edition replaces any previous versions Une nouvelle dition annule et remplace la pr c dente No N Date Date Change description Description de la Page Page mise a jour April 2000 Creation of original user guide All pages Avril 2000 Cr ation du document a l dition originale Toutes pages Remarque importante La version logicielle actuelle n offre pas la fonction RIP d crite dans ce guide Important remark The current software version does not offer the RIP function described in this guide COMPACT 155 Mbit s ADD DROP MULTIPLEXER ADR 155C Installation and User Guide Installation and User Guide N56717020101 Reproduction and communication in any form prohibited without the written permission of E Page AO 1 PORTS SECURITY LEVEL Port safety level for the 19 subrack access The connectors are identified on the front panels of the equipment cards or motherboard Connectors Security leve
48. La longueur des champs subnet et host est d finie par un masque associ l adresse Il existe trois classes d adresses e la classe A le champ NET est cod sur le premier octet les trois autres octets tant r serv s aux champs SUBNET et HOST les adresses de classe A varient de 1 0 0 0 a 126 255 255 254 e a classe B le champ NET est cod sur les deux premiers octets les deux autres octets tant r serv s aux champs SUBNET et HOST les adresses de classe B varient de 128 0 0 0 a 191 255 255 254 e a classe C le champ NET est code sur les trois premiers octets le dernier octet tant reserve aux champs SUBNET et HOST les adresses de classe C varient de 192 0 0 0 a 223 255 255 254 le nombre maximal d quipements pouvant appartenir un m me r seau IP de classe C ayant le m me NET est de 254 quipements Hem Les adresses commen ant par 127 et les adresses comportant tout 1 ou tout 0 dans les champs SUBNET et HOST sont interdites Rem Le standard IP autorise que les champs SUBNET et HOST puissent tre cod s sur un nombre de bits ne correspondant pas une fronti re d octet usuellement ceci n est pas mis en oeuvre pour des raisons de lisibilit d adresses et car la plupart des impl mentations du d mon de routage RIP ne supportent pas cette fonctionnalit Le champ SUBNET se d finit par un masque qui s crit sous la f
49. MNGT Acces synchrone V 11 diff rentiel Interconnexion possible avec d autres quipements SAGEM ADR155C FOT 155C travers des liens synchrones s rie utilis s en mode codirectionnel 64 kbit s ou contra directionnel maitre rythme d fini par ADR 155C D bit 64 kbit s Connecteur Type HE5 9 points femelles 050 o olo 9 6 o 000 N de broche D signation Polarit Remarques du signal Toun Masse non connect 6 RB 9 Entr e donn es re ues sur l interface P et chantillonn es sur le 2 Re o front montant de l horloge de r ception RXCLKP B A 7 TXPB Sortie donn es mises sur l interface P sur le front descendant LGS do d TXPA de l horloge d mission TXCLKP B A CG T 8 TXCLKPB Sortie horloge d mission en mode codirectionnel le rythme 4 TXCLKPA de l horloge d mission est issu du rythme interne de l quipement Ta RXCLKPB Entr e horloge de r ception 5 RXCLKPA En mode contradirectionnel esclave entrant les signaux TXCLK sont des entr es Chronogramme de l interface MNGT en mode codirectionnel utilisation synchrone 64 kbit s TXCLKP B A sortie horloge d mission Y gj codirectionnelle TXP B A sortie donn es mises B8 X B1 X B2 sur l interface P RXCLKP B A entr e horloge de r ception RXP B A B8 XK B1 X B2 entr e donn es re ues sur l interface P Guide d Installation et d
50. P Administrative Unit Loss Of Pointer HPOM Higher Order path Overhead Monitor HO RDI G1 HO UNEQ High order Path Unequipped HPT Higher Order Path Termination High Order Path Signal Label Mismatch High Order Path Remote Defect Indication High Order Path UNEQuipped HPA Higher Order Path Adaptation Tributary Unit Loss Of Multiframe Administrative Unit Alarm Indication Signal Non alarmed major High Order Path Remote Defect Indication minor Non alarmed Non alarmed minor Non alarmed T C Z M ZE 1 OJO 3 d T O lt minor Tributary Unit Alarm Indication Signal Non alarmed Tributary Unit Loss Of Pointer LPOM Lower Order path Overhead Monitor cc C gt QO Fa Hi minor SD 22 VC CI Table 2 9 Alarms and severity 1 2 Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 13 2 OPERATION Alarms Description Severity LPT Lower order Path Termination SD V5 v12 SE LPA Lower order Path Adaptation LO SLM Low order Path Signal Label Mismatch PPI PDH Physical Interface SETS Synchronous Equipment Timing Source Loss Of Signal on T3 sync input minor Loss Of Signal on T1 sync input Non alarmed Loss Of Signal on T2 sync input Non alarmed Failure on T4 synchronization output minor alala IN
51. Protection E1 INPUT OUTPUT ports Board status TR REC ports EOW port AUX port Figure 1 10 Menu structure Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 27 1 INSTALLATION AND COMMISSIONING Installation and User Guide N56717020101 Page A1 28 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION 2 OPERATION 2 1 Functional description The ADR 155C is an optical STM1 add drop multiplexer used to build STM 1 point to point links STM 1 rings or mesh networks so achieving the mismatch of links at 2 Mbit s Ethernet or STM1 The ADR 155C can also be connected to an equipment of the synchronous digital hierarchy in accordance with UIT T recommendations G 707 and G 783 The ADR 155C modelling in functional blocks according to standard G 783 is presented below RST Regeneration Section Termination OHA OverHead Access MST Multiplex Section Termination SETS Synchronous Equipment Timing Source MSP Multiplex Section Protection 2 l MSA Multiplex Section Adaptation HPOM Higher order Path Overhead Monitor SETPI Synchronous Equipment Timing Physical Interface HPC Higher order Path Connection HPT Higher order Path Termination HPA Higher order Path Adaptation SEMF Synchronous Equipment Management Function LUG Lower order path Unequipped Generator LPC Lower order Pat
52. Protocol SNNP agent for Routing IONOS ANM function Communication function over an ADR 155C D D over STM1 D D over STM1 de e _ m mm _ on an p ad Example 1 communication over a point to point link IONOS ANM The TPI can be connected to any Ethernet interface as soon as the parameterezing enables to reach ADR 1 equipment to be operated PE qeu SR rd em Dn 4 X X STM1 Ki d on West d on East S D Dj STM1 on East ADR X D D STM1 on West x IONOS ANM in necessary a y to operate this FOT C L D D lt Di D5 x x Db 7 but the ADR cannot be onSTMi N STM1 STM1 s operated from the ETH tributary gt lt East Ge E interface of the FOT C A 4 FOT C D D on STM1 ADR aggregate Example 2 communication over an ADR 155C and FOT 155C ring Figure 1 9 Examples of the communication function configuration Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 21 1 INSTALLATION AND COMMISSIONING 1 4 1 Configuration required The minimum configuration proposed for the operating PC is as follows Interface Serial RS232 interface Ethernet 10 base T network card Operating system Windows 95 Windows NT4 Applications Hyperterminal for Windows HTTP navigator Netscape Communicator 4 5 1 4 2 Parameterizing the communication fu
53. RVICE 1 4 3 Utilisation du navigateur HTTP 1 4 3 1 Premi re mise en service Lancer l application NESCAPE Dans l cran d accueil renseigner le champ Adresse avec l adresse IP de l quipement ADR155C ATTENTION Avec NESCAPE 4 5 l adresse IP de l quipement ne doit pas comporter de 0 non significatif Exemple http 135 11 9 30 au lieu de http 135 11 09 30 L cran d accueil du navigateur Welcome on the ADR155C s site apparait Lors de la premi re mise en service le mot de passe est vide cliquer sur Apply pour acc der l cran ADR155C shelf view e Le navigateur est d s lors op rationnel 1 4 3 2 Pr sentation du navigateur A l ouverture d une session sur le navigateur HTTP l cran ADR155C shelf view repr sente la vue globale de l quipement o chaque alv ole est rep r e par une lettre A B C D ou M conform ment la Figure 1 1 Ed ADR 155 C 8 171 117 203 Operator Netscape Fichier Edition Afficher Aller Communicator Aide 3 A a u Pr c dent Etant Recharger Accueil Rechercher Guide Imprimer S curit ATeter amp SAGEM C RE Ins erted ADRTLIEDLM EQ eT tr S 10 100 HalfiFull e ee E D BN Cet cran permet de visualiser l tat de l quipement en particulier e les incoh rences entre configuration et constitution chaque alv ole comporte le nom de la carte attendue haut gauche et le nom de la carte ins r e
54. SAGEM SA 2 EXPLOITATION Gestion des boucles Sur les sites distants les deux boucles sortantes locales Local user outputs A et B sont activ es sur l apparition d une alarme locale alarme quipement ou boucles de t l signalisation 3 et 4 Local user input 3 ou 4 La fonction d port de boucles permet de rapatrier sur un quipement appel site central les d fauts pr sents sur les sites distants Pour ce faire chaque site doit transmettre au site central une information de pr sence d alarme Cette information qui correspond une boucle de t l signalisation 1 ou 2 Local user input 1 ou 2 est transmise sur l octet S1 Pour associer cette information aux alarmes d un quipement il suffit de connecter les sorties des boucles A et B Local user outputs A et B respectivement sur les entr es de t l signalisation 1 et 2 Local user input 1 ou 2 Le cha nage de l information dans une topologie de type bus ou anneau est assur par la validation d une fonction OU entre les informations re ues Far user inputs 1 et 2 via S1 STM1 Ouest et S1 STM1 Est d une part et l information locale d autre part au niveau de chaque site constituant le r seau Au niveau de l quipement site central la validation d une fonction OU entre les informations re ues Far user inputs 1 et 2 via S1 STM1 Ouest et S1 STM1 Est d une part et les informations locales Local user input 1 ou 2 et alarme locale d autre part perme
55. SAGEM SA 2 1 2 EXPLOITATION 2 EXPLOITATION Pr sentation fonctionnelle L ADR 155C est un multiplexeur add drop optique STM1 qui permet de construire des liaisons point point STM1 des anneaux STM1 ou des r seaux maill s en r alisant ainsi le d port de liaisons 2 Mbit s Ethernet ou STM1 L ADR 155C peut aussi tre raccord un quipement de la hi rarchie num rique synchrone conforme aux recommandations G 707 et G 783 de l UIT T La mod lisation de l ADR 155C en blocs fonctionnels selon la norme G 783 est pr sent e ci apr s SPI Interface Physique synchrone o SSS o RST Terminaison de section de r g n ration OHA Acc s au surd bit MST Terminaison de section de multiplexage MSP Protection de section de multiplexage NENNEN l quipement synchrone MSA Adaptation de section de multiplexage HPOM Surveillance de pr fixe de conduit d ordre sup rieur SETPI Interface physique de synchronisation de HPC Connexion de conduit d ordre sup rieur l quipement synchrone HPT Terminaison de conduit d ordre sup rieur HPA Adaptation de conduit d ordre sup rieur SEMF Fonction de gestion Se E eae d quipement synchrone LUG G n rateur de conduit d ordre d ordre inf rieur non quip LPOM Surveillance de pr fixe de conduit d ordre inf rieur MCF Fonction de E LPC Connexion de conduit d ordre inf rieur LPT Terminaison de conduit d ordre inf rieur LPA Adapta
56. STM1 7 DD sur STM1 Sa N Ouest X X Est S D D Sur STM1 Est k x D D sur STM1 Ouest Fs N d faut IONOS ANM pour DD D D x X D D E sur Affluent sur STM1 Ge pd mais on peut exploiter Est uest _ l ADR depuis l interface G STM1 FOT C D la D sur R sultant STM1 ADR Exemple 2 communication sur un anneau d ADH 155C et de FOT 155C Figure 1 9 Exemples de configuration de la fonction de communication Guide d Installation et d Utilisation Nb6717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 21 1 INSTALLATION ET MISE EN SERVICE 1 4 1 Configuration n cessaire La configuration minimale propos e pour le PC d exploitation est la suivante Configuration 1 Configuration 2 Processeur Pentium 266 MHz Affichage 800x600 256 couleurs conseill 1024x768 Interface Interface s rie RS232 Carte r seau Ethernet 10 base T Syst me d exploitation Windows 95 Windows NT4 Applications Hyperterminal pour Windows Navigateur HTTP Netscape Communicator 4 5 1 4 2 Param trage de la fonction communication La Figure 1 9 pr sente les ressources disponibles et diff rentes configurations possibles de la fonction de communication Raccorder l acc s COMM de l quipement un port COM non utilis du PC avec mulation VT100 Mett
57. TP sa configuration minimale est d finie au paragraphe 1 4 1 Un terminal local avec mulation VT100 est indispensable lors de la premi re mise en service afin de pouvoir acc der l quipement via la fonction de gestion toutefois celui ci ne permet que le param trage de la fonction communication Proc dure A la premi re mise en service l quipement scrute sa constitution et la prend comme configuration attendue en service non monitor Il est donc conseill d ins rer toutes les cartes d acc s avant la mise sous tension afin d acc l rer la mise en service Mettre en marche l alimentation raccord e l quipement L quipement effectue des auto tests lorsque les auto tests se sont d roul s correctement le voyant ON est allum dans le cas contraire un code de clignotement du voyant d finit l auto test d faillant contacter la hotline amp Param trer l interface de communication l aide de la VT100 voir 1 4 1 amp A l aide du navigateur HTTP voir 1 4 3 e Mettre jour l heure et la date de l quipement Mettre chaque carte d acc s sous surveillance valider la commande Monitoring Raccorder les acc s 2 Mbit s et ou Ethernet selon la constitution de l quipement Raccorder les acc s AUX et EOW n cessaires T l charger une configuration pr d finie ou laborer la configuration souhait e l aide du navigateur HTTP Creer les connexions Etablir les
58. U IP 1 Cette annexe d crit d une fa on succincte les r gles permettant de construire RGT bas sur la suite de protocoles IP Pr ambule La suite de protocoles IP permet dans un r seau de transmission de donn es le transport de donn es sous la forme de paquets entre deux points du r seau Selon le mod le ISO IP est le protocole de la couche r seau Il a donc en charge au sein de chaque n ud le routage de paquets afin que ceux ci puissent tre achemin s dans le r seau Les protocoles situ s en dessous d IP correspondent aux couches liaison et physique ils tablissent des liaisons entre deux noeuds cons cutifs du r seau Les protocoles au dessus d IP TCP et UDP sont les protocoles de la couche transport ils assurent une transmission de donn es de bout en bout entre deux points loign s du r seau Les protocoles s appuyant sur TCP UDP sont orient s applicatifs ils offrent des services tels que le transfert de fichiers TFTP sur UDP FTP sur TCP la gestion d quipements SNMP la messagerie SMTP La figure ci dessous d crit l empilement des principaux protocoles pouvant tre mis en jeu dans un n ud du r seau vers Automate vers fonctions Serveur HTTP de t l chargement d exploitation 1 SNMP i J TCP UDP KA Ethernet EOC Suite des protocoles IP Rem Le protocole MAC se rattache au port physique Ethernet media point multi points
59. Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 9 1 INSTALLATION ET MISE EN SERVICE 1 3 2 3 Acc s de synchronisation 2 Mbit s G 703 Interface SYNC Acc s 2 Interfaces d entr e de synchronisation externe 2 MHz G 703 T3 et une interface de sortie de synchronisation 2 MHz G 703 T4 Conforme la recommandation G 703 de l UIT T 10 3 pour l interface d entr e tab 10 pour l interface de sortie D bit 2 048 Mbit s 50 ppm Imp dance 120 Q sym trique Connecteur HE5 9 points femelles 120 Q 5 O O O O o l 7 INC SE NOTA Le blindage du connecteur est reli a la masse lectrique de la face avant du chassis NC Ld qe 6 2 SERRE REC O8 j MEME HE E pu e 9 o5 1 1 3 2 4 Acc s de trafic 21 x 2 Mbit s G 703 Acc s E1 INPUT et E1 OUTPUT Acc s Acc s de trafic 21 x 2 Mbit s Conforme la recommandation G 703 de l UIT T 6 3 pour l interface d entr e tab 6 pour l interface de sortie D bit 2 048 Mbit s 50 ppm Code HDB3 Imp dance 120 Q sym trique Connecteur SUB D haute densit 44 points femelles supportant le c ble L907 21 acc s Deux connecteurs sont associ s aux acc s les appellations RX correspondent celles du connecteur E1 INPUT et les appellations TX celles du connecteur E1 OUTPUT 15 000000000000000 1 30 0000000000000000 16 44V O0O000000
60. _ _ T1 C TO ADR155C1 Internal T1 C TO SSM PRC synchronization TO T3 2 MHz clock output T4 TO T3 ADR155C1 ADR155C 3 Synchronization of other equipments SSM PRC 2 MHz clock output T4 T1 N Synchronization of other equipments Figure 2 1 Synchronization from the 2 MHz external sync input T3 2 Mbit s port T2 Quality PRC Priority 1 STM 1port T1 C STM 1port T1 C Quality DNU Quality DNU Priority 2 Priority 2 ADR155C 2 Kee ge S T1 C TO T1 c West Internal T1 C TO T2 SSM SEC TO T1 C West synchronization or T2 ADRA55C1 TO T2 2 MHz clock output T4 TO Tic West ADR155C 3 Synchronization of other equipments SSM SEC 2 MHz clock output T4 T1 N Synchronization of other equipments NOTE Synchronization is applied to the 2 Mbit s port of the ADR155C which is enabled first local ADR155C in the example Figure 2 2 Synchronization from a 2 Mbit s port Installation and User Guide N56717020101 Page A2 10 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Loops Management On remote sites two local outgoing loops Local user outputs A and B are activated on the appearance of a local equipment alarm or remote indication loops 3 and 4 Local user input 3 or 4 The remote loopback function allows an equipment named present on remote sites central s
61. age d un quipement donn comprend les champs suivants e destination IP correspond l adresse IP de l quipement ou du sous r seau voire du r seau que l on veut atteindre partir de l quipement donn e subnet mask masque de sous r seau associ l adresse IP d finie dans destination QIP tous les quipements dont la partie d adresse IP d finie par les bits 1 de ce champ correspond a la m me valeur que la partie de destination IP d finie par ce m me masque pourront tre atteints gr ce cette route e next hop IP adresse IP du prochain quipement connect en direct avec l quipement donn auquel va tre envoy le paquet e metric on parle aussi de co t ou de distance valeur de 1 15 indiquant le nombre de bonds pour atteindre l quipement correspondant l adresse destination IP 16 correspond l infini pour le d mon de routage RIP Ce champ est utilis uniquement par un ventuel d mon de routage pour choisir une route pr f rentielle s il existe plusieurs routes diff rentes pour une m me destination Il est possible de toujours renseigner ce champ 1 dans un but de simplification si son exploitation n est pas indispensable e interf num ro de l interface qui permet d atteindre le prochain quipement dont l adresse IP est next hop IP Hem La d claration des adresses IP des interfaces induit l tablissement de routes statiques
62. ansmission between two remote points on the network The protocols based on TCP UDP are application oriented they offer services such as file transfer TFTP over UDP FTP over TCP equipment management SNMP messaging SMTP etc The figure below describes the stacking of the main protocols that can be used in a network node To download To OS HTTP Server mechanism functions Ethernet EOC IP protocol suite Note The MAC protocol is linked to the Ethernet physical port point multipoint media and PPP protocol is linked to the physical ports for the point to point links optical radio V11 etc Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page AA 1 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN A 2 Addressing IP To route packets in a node IP uses an addressing mechanism depending on the destination address contained in the packet it determines by polling its routing table the next router to which it should send the packet and determines the physical interface over which it should transmit the packet The terms router and equipment will be used interchangeably in the following There are two non exclusive ways of updating IP routing tables e use of static routes entered by operator e use of a routing demon such as RIP RIP2 OSPF which takes charge of dynamic management of routing tables across the network The IP addresses
63. aram tres de communication Les raccordements du r seau de gestion s effectuent via les DCC D1 D3 ou D4 D12 des STM1 ou sur les interfaces Ethernet ETH ou P MNGT de l quipement L ADR155C prend place dans des baies 19 ou b tis ETSI Il est constitu d un ch ssis 2U quip d une carte m re regroupant les fonctions de base de l quipement d un fond de panier et d une alimentation 48V DC s curis e d un module ADRFAN compos e de deux blocs de ventilation redondants de quatre cartes d acc s au choix carte d acc s STM1 optique IC1 1 ou IC1 2 carte ADR IC1 1 ou ADR IC1 2 permettant une connexion VC4 ou 3 connexions VC3 ou 63 connexions VC12 ou un mixte de connexions VC3 VC12 carte d acc s 21 x 2 Mbit s G 703 carte ADR21E120 permettant 21 connexions VC12 carte d acc s Ethernet 10 100 carte ADR LAN1 permettant 2 connexions VC3 Guide d Installation et d Utilisation Nb6717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 1 1 INSTALLATION ET MISE EN SERVICE o0 Chassis ADR 155C Montants gauches de la baie ADR 155C bati ETSI ADR 155C CHASSIS 19 2 vis HS M6x12 2 ecrous 2 ecrous cage M6 cage M6 Montage en baie 19 Montage en b ti ETSI Figure 1 1 Installation du ch ssis ADR155C Guide d Installation et d Utilisation Nb6717020101 Page B1 2 Reproduction et communication interdites sans au
64. ation configurable from O to 15mn in one second steps WTR SF and SD fault persistence path by path configurable from O to 10s in 100ms steps Hold off time LPT Lower order Path Termination oignal label VC12 transmitted expected and received Label Transmitted 000b no connection or 010b asynchronous if connection not configurable by the operator Expected possible value 001b equipped without specification or 010b asynchronous Received SD V5 threshold VC12 configurable from 10 to 10 for VC12 SD V5 threshold ADRLAN Card Signal label VC3 i transmitted expected and received Label Transmitted not configurable Expected not configurable Received Bit rate Forcing the Ethernet port bit rate 10 Mbit s The bit rate is imposed on or self adaptive to the connection selection of the maximum proposed bit rate on the half or full duplex bus Flow control LAN towards VC3 60 itowardsVC3 j or LAN 60 ASH ASH Table 2 3 Configuration parameters 3 6 Installation and User Guide N56717020101 Page A2 4 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Configuration parameters per functional blocks Default value ADRLAN Card continue Interface configuration LAN in service no service Service 300 s UNNAMED VC3 CRC7 Maximum route Age Path trace J1 tra
65. ation parameters 4 6 Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 5 2 OPERATION Configuration parameters per functional blocks Default value OHA OverHead Access EOW interface operating mode CO codirectional or CT contra directional master EOW configuration Selection of E1 E2 ad AUX interface operating mode F1 CO codirectional or CT contra directional master AUX configuration 4 MCF Message Communications Function MNGT interface operating mode CO codirectional or CT contra directional master P port configuration Q d Equipment Selection of clearance level Administrator Operator Observer One password by clearance level No password Only the administrator may modify password Equipment date and time 01 01 1970 Status of slots A B C D slot configured with an expected card A C ADR21E120 B D ADRIC1 x Monitoring of modules No Monitoring A no monitored card is indicated in the equipment view not monitoring a card inhibits the entire management of the faults related to this card card and port Subrack Monitoring Monitoring Monitoring of ports Monitoring Not monitoring a port inhibits the entire management of the faults related to for physical port this port No Monitoring for performance Putting a card into out of service Service The ca
66. auts AU SLM et TU LOM Les d fauts TU AIS et TU LOP d une entr e non connect e sont filtr s DEFAUTS DEFAUTS Ai Lob UP UNE fibi LP resm ios as Corr lation des d fauts acc s DEFAUTS DEFAUTS os as _ Corr lation des d fauts distants Les d fauts LO REI LO RDI HO REI et HO RDI d une entr e de connexion unidirectionnelle sont filtr s Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 17 2 EXPLOITATION 2 6 Traitement de la qualit Le traitement de la qualit consiste superviser les points de surveillance suivants pour l quipement local la section de r g n ration octet B1 near end working protection RS section de multiplexage octet B2 near end working protection MS les conduits near end Low Path Virtual Container etles conduits VC12 octet V5 near end Low Path Virtual Container pour l quipement distant section de multiplexage octet M1 far end working protection MS les conduits far end Low Path Virtual Container e etles conduits VC12 octet V5 far end Low Path Virtual Container Le traitement de la qualit comporte les fonctions suivantes calcul du nombre de blocs erron s ou d erreurs bits sur les anomalies locales et distantes et surveillance de l apparition des d fauts sur une p riode d une seco
67. bel transmitted expected and received byte C2 of VC4 path overhead Label Transmitted possible values 01H equipment not specified or 02H TUG mode structure Expected possible values 01H equipment not specified or 02H TUG mode structure Received hexadecimal value Path trace Byte J1 transmitted UNNAMED UNNAMED VC4 CRC7 not configurable and not treated in reception VC4 CRC7 LUG Lower order path Unequipped Generator Number of the unequipped VC12s transmitted in TUG3s by default no connection LPOM Lower order path overhead monitor Signal label VC 12 received Label Rec Signal label VC3 received Label Rec SD threshold configurable from 10 to 107 for VC3 configurable from 10 to 10 for VC12 SD threshold Table 2 2 Configuration parameters 2 6 Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 3 2 OPERATION Default value Configuration parameters per functional blocks LPC Lower order Path Connection Service Te bearestonal unrecional MONO _ FIT C RR NN Revertive authorization path by path return after a WTR time delay to the working link when the fault SF or SD causing the switch has disappeared Revertive Wait Time to Restore WTR period common to all paths in revertive mode period following restoration of nominal oper
68. boration des compteurs 15 minutes et 24 heures Le r sultat de ces calculs est ensuite cumul pour chaque point de surveillance dans des compteurs 24 heures BBE ES SES et UAS et des compteurs 15 minutes BBE ES SES et UAS Les six derni res p riodes d indisponibilit UNAVAILABLE PERIODS sont conserv es et visualisables partir du navigateur HTTP Le traitement de la qualit est initialis d s que l quipement est mis sous tension et que le point de surveillance est active monitored Les 16 derniers compteurs 15 minutes non nuls le compteur 15 minutes courant le dernier compteur 24 heures non nul le compteur 24 heures courant et les 6 derni res p riodes d indisponibilit sont visualisables partir du navigateur HTTP Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 19 2 EXPLOITATION 2 7 Proc dures de changement de sous ensemble Remplacement d une carte Observations Des alarmes apparaissent lorsqu une carte est extraite du ch ssis Afin d viter la remont e des alarmes Mim et boucles ALA 1 et ALA 2 la carte doit tre d clar e hors service Chaque module peut tre extrait ou ins r sans intervention sur les autres modules ou leur c blage Seul le trafic du module concern est perturb Proc dure La proc dure d crite ci dessous peut s appliquer sauf indication contraire
69. ce de pr fixe de conduit d ordre sup rieur higher order path overhead monitor Etiquette signal octet C2 du surdebit de conduit du VC4 attendue et re ue Label Expected valeurs possibles 01H quipement non sp cifi ou 02H structure en TUG Received HPT de conduit d ordre sup rieur Higher Order Path Termination Etiquette signal octet C2 du surd bit de conduit du VC4 transmise attendue et recue Label Transmitted valeurs possibles 01H quipement non sp cifi ou 02H structure en TUG Expected valeurs possibles 01H quipement non sp cifi ou 02H structure en TUG Received valeur en hexad cimale Path trace J1 mis UNNAMED UNNAMED VC4 CRC7 non configurable et non trait en r ception VC4 CRC7 LUG G n rateur de conduit d ordre inf rieur non quip Lower order path Unequipped Generator Num ro des VC12s non quip s mis dans les TUG3s par d faut pas de connexion LPOM Surveillance de pr fixe de conduit d ordre inf rieur lower order path overhead monitor Etiquette signal VC12 recue Label Rec Etiquette signal VC3 recue Label Rec Seuil SD configurable de 10 10 pour VC3 configurable de 10 10 pour VC12 SD threshold Tableau 2 2 Param tres de configuration 2 6 Guide d Installation et d Utilisation N56717020101 Reproduction et co
70. ch acknoledgements occur only at the level of major and minor output loops RESET of performance logs 15 mn i Hot reset of the equipment performed by software the reset time should be shorter than 30s Table 2 8 Commands 2 2 RESET of performance logs 24h 1 2 4 Predefined functions On commissioning the following mechanisms are implemented automatically e Synchronization e management of outgoing remote indication loops Synchronization The synchronisation of the local equipment and remote equipment is managed according to the available synchronization sources their quality and the priority they are allocated The synchronization sources possible are standalone operation local oscillator T1 extracted from one of the incoming STM1 streams 1 to 4 possibilities according to the number of ADRIC1 x cards present in the equipment 2 0ne 2 Mbit s G 703 source per declared 2 Mbit s module and selected from the various 2 Mbit s G 703 accesses 13 two external 2 MHz G 703 sources Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 9 2 OPERATION The following figures give typical synchronization examples according to equipment connections 2 MHz external sync input T3 Quality PRC Priority 1 STM 1port T1 C STM 1port T1 C Quality DNU Quality DNU Priority 2 Priority 2 ea uM Ce
71. comme alarme station ou t l commande courant maximal 100mA sur charge r sistive Connecteur Type HE5 15 points femelles 080 e000 o lo 15 9 0900009909 1 BREAKB Contact repos de la boucle s che B 9 COMMON B Contact commun de la boucle s che B EN Contact travail de la boucle s che 10 BREAKA Contact repos de la boucle s che A T 0 COMMON A Contact commun de la boucle s che A _ WS gt MAKE A Contact travail de la boucle s che A 4 GND Masse 12 R MON4P 0B Boucle de t l signalisation N 4 EE ea 13 R MON3P OB Boucle de t l signalisation N 3 EE 14 R MON2P OB Boucle de t l signalisation N 2 EE e 15 R MON1P OB Boucle de t l signalisation N 1 er NOTA OB est le OU logique des signaux OB1 et OB2 des interfaces alimentation PWR PWRA et PWRB Interface ETH Acc s Interface Ethernet de gestion fonctionnant 10 Mbit s en mode half duplex ou full duplex selon le mode utilis par l interlocuteur adaptation dynamique du port Ethernet chaque nouvelle connexion de l interlocuteur Connecteur Type RJ48 RJ45 blind Contact 1 Contact 8 Iu vue de face Sortie Ethernet point chaud Sortie Ethernet point froid Entr e Ethernet point chaud Entr e Ethernet point froid Guide d Installation et d Utilisation N56717020101 Reprod
72. correspond a r seau d isolement et les NET 160 1 et 150 1 correspondent a des AS dans lesquels RIP est active Guide d installation et d utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page BA 5 ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP Guide d installation et d utilisation N56717020101 Page BA 6 Reproduction et communication interdites sans autorisation crite de SAGEM SA En cas de difficult s rencontr es lors de l installation ou de l utilisation n h sitez pas If you encounter problems during installation or use do not hesitate to CONTACTER NOTRE HOTLINE PRODUITS SDH CONTACT OUR SDH PRODUCTS HOTLINE UN SEUL NUMERO DE TELEPHONE ON A SINGLE TELEPHONE NUMBER en France m tropolitaine in mainland France 01 55 75 77 77 ou depuis l trangeror from abroad 33 1 55 75 77 77 UN SEUL NUMERO DE FAX ON A SINGLE FAX NUMBER en France metropolitaine in mainland France 01 55 75 77 70 ou depuis l trangeror from abroad 33 1 55 75 77 70 UN SEUL Email ON A SINGLE Email address SAGEM HOTLINE SAGEM FR N oubliez pas de vous munir de votre numero de client qui est inscrit sur votre facture Don t forget to provide yourself with your customer number which is written on your bild SAGEM SA Networks and Telecommunications Division S SAGEM Le Ponant de Paris 27 rue Leblanc 75512 PARIS CEDEX 15 FRANCE Tel 33 1 55
73. count to include the worst case security These ASs are mutually independent within RIP and are linked via isolated networks each constituting a single link Ethernet or point to point Each isolated network has its own NET number The equipment interfaces belonging to an isolated network must be filtering RIP filtering option activated on these interfaces i e they prohibit export of automatic updates of RIP routing tables These equipment pieces with a filtering interface are designated border Within an AS all equipment pieces must have their RIP routing demon activated Within each AS each link between two equipment pieces is described by a specific SUBNET value The routings from one AS to another AS via an isolated network are described using static routes In the example given above NET 128 1 corresponds to an isolated network and NETs 160 1 and 150 1 correspond to ASs in which RIP is activated Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page AA 5 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN Installation and User Guide N56717020101 Page AA 6 No reproduction or communication without the written consent of SAGEM SA MULTIPLEXEUR ADD DROP a 155 Mbit s COMPACT ADR 155C Guide d Installation et d Utilisation Guide d Installation et d Utilisation Nb6717020101 Reproduction et communication interdites sans autorisation
74. crite de SAGEM SA Page BO 1 NIVEAUX DE SECURITE DES ACCES Niveau de s curit des acces du chassis 19 Les connecteurs sont rep r s sur les faces avant de l quipement carte m re et modules s curit PWRAPWRB TBTS PWR Acc s alimentation TBTS Z Acc s de gestion locale via une console au standard TBTS VT100 ou un PC Im T TR et REC Acc s optique STM 1 IC1 1 ou IC1 2 G 957 et G 958 Laser classe 1 Sans danger Acc s de gestion distante via un r seau Ethernet TBTS LOOPS Acc s boucles s ches et t l signalisations TBTS m 4 SR Acc s Ethernet TBTS E1 INPUT amp E1 OUTPUT Acc s de trafic 2 Mbit s G 703 TBTS Le ch ssis 19 ne doit tre mont que dans des baies ou b tis dont la partie inf rieure est ferm e ou quip e d un filtre air class V1 ou HF1 au minimum ou reposant sur un sol non inflammable Obligation de terre s re Ce mat riel ne peut tre install que par un personnel comp tent Sa conformit est conditionn e au raccordement de la borne de terre de protection une terre s re de r sistance Z lt 5 ohms Pr caution de manipulation Toute intervention l int rieur des quipements n cessite obligatoirement l utilisation d un bracelet lectrostatique Pile au Lithium Attention il y a danger d explosion s il y a remplacement incorrect de la pile Remplacer uniquement avec une batterie de m me type ou d un type quivalent recommand par
75. cting Power Supply 1 3 2 Connecting on motherboard 1 3 3 Connecting on the ADR IC1 x card 1 3 4 Connecting on ADR LAN1 card 1 3 5 Connecting on ADR 21E120 card 1 3 6 75 Q connecting strip 1 4 Commissioning 1 4 1 Configuration required 1 42 Parameterizing the communication function 1 4 8 Using HTTP navigator Figure 1 1 ADR155C Subrack Installation Figure 1 2 Connecting power supply ports Figure 1 3 Connecting motherboard inputs Figure 1 4 Connecting ADR IC1 x card inputs Figure 1 5 Connecting ADR LAN 1 card input Figure 1 6 Connecting ADR 21E120 card input Figure 1 7 75 Q connecting strip Figure 1 8 Commissioning procedure for ADR155C network Figure 1 9 Examples of the communication function configuration Figure 1 10 Menu structure 2 OPERATION 2 1 Functional description 2 2 General 2 3 Operational parameters 2 4 Predefined functions 2 5 Alarms processing 2 6 Performance processing 2 Procedure for replacing subassemblies 0 2 A0 T to AA 6 A0 2 A0 3 to A0 4 A1 1 to A1 28 A1 1 A1 3 A1 4 A1 4 A1 7 A1 13 A1 16 A1 17 A1 18 A1 20 A1 22 A1 22 A1 26 A1 2 A1 5 A2 1 to A2 20 A2 1 A2 2 A2 2 A2 9 A2 12 A2 17 A2 19 Installation and User Guide N56717020101 Reproduction and communication in any form prohibited without the written permission of E Page A0 3 Figure 2 1 Synchronization from the 2 MHz external sync input T3 A2 10 Fig
76. d Monitoring point SES declaration threshold MS byte B2 for local and MS byte M1 for remote 2400 HS byte B1 for local 2400 VC3 for local VC12 byte V5 for local UAS UnAvailable Second number of seconds of unavailability BBE Background Block Error number of residual errored blocks excluding SES Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 17 2 OPERATION Generation of 15 minute and 24 hour counters The result of these calculations is then aggregated for each of the monitoring points in 24 hour counters BBE ES SES and UAS 15 minute counters BBE ES SES and UAS The last 6 UNAVAILABLE PERIODS are stored and displayed on HTTP navigator The performance process is initialized when the equipment is powered up and the monitoring point is monitored The last 16 non zero 15 minute counters the current 15 minute counter the last non zero 24 hour counter the current 24 hour counter and the last 6 unavailable periods are displayed on HTTP navigator Installation and User Guide N56717020101 Page A2 18 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION 2 7 Procedure for replacing subassemblies Replacing a card Remarks Alarms appear whenever a card is extracted from the subrack In order to prevent feedback of M m alarms and ALA 1 and ALA 2 loops the card sh
77. dule ADR LAN Interface ETH Acces Interface Ethernet de trafic fonctionnant a 10 ou 100 Mbit s en mode half duplex ou full duplex selon le mode utilis par l interlocuteur adaptation dynamique du port Ethernet chaque nouvelle connexion de l interlocuteur Connecteur Prise Ethernet 10 ou 100 BaseT Type RJ48 RJ45 blind Contact 1 Contact 8 LL vue de face N de broche Sortie Ethernet point chaud Sortie Ethernet point froid Entr e Ethernet point chaud Entr e Ethernet point froid NOTA Deux LEDs sont associ es au connecteur ETH LED de couleur verte Activity indicateur de l tat du trafic LED de couleur jaune Link indicateur de l tat de la liaison Caract ristiques lectriques conformes 802 30 Guide d Installation et d Utilisation N56717020101 Page B1 16 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE 1 3 5 Raccordement sur le module ADR 21E120 Les raccordements de trafic 2 Mbit s effectu s sur les acc s E1 INPUT et E1 OUTPUT de la carte ADR21E120 sont identiques ceux effectu s sur les acc s E1 INPUT et E1 OUTPUT de la face avant de la carte m re voir 1 3 2 4 DR 21E120 0000000000000000 PS 000000000000000 000000000000 00 MEUS o E1 INPUT STATUS E1 OUTPUT
78. e e acass couts DO E Scores Liat EM dd 1 tr The screen displays the already defined management routes with their characteristics No reference of the route destination IP destination IP address equipment or subnetwork subnet mask subnetwork mask next hop IP IP address of the next equipment connected on line with the given equipment Installation and User Guide N56717020101 Page A1 24 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING interface interface used to reach the next equipment cost or metric number of hops to reach the destination From this screen it is possible to change the existing routes to delete them or to create new ones the static routing is necessary if FOT155C s are present on the network or for an interconnection with a contiguous network Choice 3 Display of routing information adr155 HyperTerminal OP EX Fichier Edition Affichage Appel Transf rer 7 Dig amp ADR155C SPACE refresh ESC previnus main menu RIP ROUTING TABLE Page 1 1 destination ip subnet mask next hop Aip Intf Proto Cost Ab bb ee 020 000 000 000 255 000 000 000 020 000 000 010 local 030 000 000 000 255 000 000 000 030 000 000 001 PPPI other dir 255 255 255 255 255 255 255 255 127 255 251 223 null other other t toggle route filter up d
79. e l acc s 2 Mbit s choisi pour T2 T2 Tributary port 1 acc s par carte 2 Mbit s d clar e Autorisation de r versibilit commune toutes les sources retour apr s une dur e WTR sur la liaison normal lorsque le d faut SF ou SD ayant entrain la commutation a disparu Revertive P riode WTR Wait Time to Restore commune tous les sources en mode r versible temporisation de retour sur la liaison normale configurable de O 30mn par pas de 1s WTR Source s lectionn e pour T4 Active source TO Contr le du mode SASE activation ou d sactivation Choix de la source T3 pour le mode SASE T3 1 ou T3 2 oeuil de qualit pour T4 PRC PRC Primary Reference Clock SSUT Synchronisation Supply Unit Transit SSUL Synchronisation Supply Unit Local SEC Synchronisation Equipment Clock Tableau 2 4 Param tres de configuration 4 6 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 5 2 EXPLOITATION Param tres d exploitation en fonction des blocs fonctionnels Valeur par d faut Acc s au surd bit OverHead Access Mode de fonctionnement de l interface EOW CO codirectionnel ou CT contra directionnel maitre EOW configuration Selection de E1 E2 Mode de fonctionnement de l interface AUX F1 CO codirectionnel ou CT contra directionnel maitre AUX c
80. e maximum Sensibilit 10 Att nuation garantie Port e typique Connecteur 10 1 12 L 1 1 5 1 1 ou IC 1 2 L 1 2 S 12 155 520 Mbit s 15 ppm UIT T G 957 G 958 Non cod NRZ monomode 1300 nm 1C1 1 ou 1550 nm IC1 2 UIT T G 652 5 0 dBm O dBm 34 dB O 28 dB sans att nuateur externe O 60 km 1C1 1 ou 0 90 km IC1 2 FC PC tout c ramique Il est possible d utiliser une fibre optique multi mode de diam tre inf rieur ou gal 62 5 microns Le budget optique est alors r duit 25 du budget optique obtenu avec une fibre mono mode La fibre optique mission est de type mono mode et la fibre optique r ception est de type multi mode 1 3 3 2 Raccordement des voies de service Interface EOW et AUX Acc s D bit synchrone V 11 diff rentiel 64 kbit s Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 13 1 INSTALLATION ET MISE EN SERVICE Connecteur Type HE5 15 points femelles 8 1 15 ooo coc g N de broche D signation Pola Remarques du signal rit Non connect Entr e donn es transmettre sur la trame STM 1 et 2 chantillonn es sur le front montant de l horloge T64 B A 10 Sortie synchro octet en mission indiquant le positionnement du bit 1 et mise sur le front montant de l horloge T64 B A
81. eT RJ48 Type Shielded RJ45 Pin 1 N Pin 8 Front view inne Signaname Comments 0 Ethernet output hot point Ethernet output cold point Ethernet input hot point Ethernet input cold point NOTE Two LEDs are linked to the ETH interface LED Activity green colour Trafic status indicator LED Link yellow colour Link status indicator Electrical characteristics compliant with the IEEE 802 3U Installation and User Guide N56717020101 Page A1 16 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING 1 3 5 Connecting on ADR 21E120 card 2 Mbit s traffic connections performed on E1 INPUT and E1 OUTPUT ports on the ADR21E120 card are identical with those performed on E1 INPUT and E1 OUTPUT ports on the front side of the motherboard see 1 3 2 4 DR 21E120 0000000000000000 0000000000000000 GC S STATUS E1 OUTPUT E1 INPUT FER ARIS E1 OUTPUT and E1 INPUT Green Red 15 000000000000000 1 30 OOOOOOOOOOOOOOO 16 ON OFF Card in service 44 31 ON ON Card in alarm OFF OFF Hardware default fuse OFF ON Card out of service 1685 Flashing Autotest default 1 Tx Rx 1A 17 Tx Rx 2B 31 Tx Rx 1B 2 Tx Rx 3B 18 Tx Rx 32 Tx Rx 2A Tx Rx 4A 19 Tx Rx 5B 33 Tx Rx 4B 4 Tx Rx 6B 20 Tx Rx 6A 34 Tx Rx 5A 5 Tx Rx 7A 21 Tx Rx 88 35 Tx Rx 7B 6 Tx Rx 9B
82. ection de multiplexage Multiplex section Termination Surveillance de l EBER B2 configurable en Monitoring ou No Monitoring Monitoring Lorsque EBER B2 n est pas surveill les actions cons quentes AIS SF et MS RDI sont inhib es Seuil SD B2 configurable de 10 10 SD B2 threshold MSP Protection de section de multiplexage Multiplex Section Protection Type de liaison 1 0 ou 1 1 Mode de s curisation bidirectionnel unidirectionnel Mode BIDIR Autorisation de r versibilit retour apr s une dur e WTR sur la liaison normal lorsque le d faut SF ou SD ayant entrain la commutation a disparu Revertive Tableau 2 1 Param tres de configuration 1 6 Guide d Installation et d Utilisation Nb6717020101 Page B2 2 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Param tres d exploitation en fonction des blocs fonctionnels Valeur par d faut MSP Protection de section de multiplexage Multiplex Section Protection suite P riode WTR Wait Time to Restore en mode r versible temporisation de retour sur la liaison normale configurable de O 15mn par pas de 1s WTR Priorit SF SD selon la recommandation G 783 1994 annexe A 1 2 1 valeur possible high ou low compatibilite MXA Sf sd priority Persistance des d fauts SF et SD configurable de 0 a 10s par pas de 100ms Hold off time HPOM Surveillan
83. ed on the ground fixed and protected qualification and component ageing Any changes in the above requirements may entail variations in the results The fan module does not operate continuously but only for high ambient temperature TRANSFORMER 110 240 48V 60W OPTIONAL Dimensions without cable and connector LxlxH 1382 mm x 58 mm x 30 mm Operating temperature OC to 40 C Storage temperature 20 C to 85 C Inout voltage 90 to 264 VAC 47 to 63 Hz output voltage 48 VDC Electronics protection Short circuit and overload EN60950 and UL CSA Installation and User Guide N56717020101 Page A4 2 No reproduction or communication without the written consent of SAGEM SA ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN This annex summarizes the rules for constructing a TMN based on the IP protocols suite A 1 Preamble The IP protocols suite enables the transport of data in a transmission network in the form of packets between two points in the network According to the ISO model IP is the network layer protocol It is therefore responsible for the packet routing of each node so that the packets can be routed correctly via the network The protocols below IP correspond to the link and physical layers they set up the links between two consecutive network nodes The protocols above IP TCP and UDP are the transport layer protocols they enable end to end data tr
84. elf view screen e From that moment the navigator is operational 1 4 3 2 Navigator Presentation On session opening on the HTTP navigator the ADR155C shelf view represents the equipment global view where each slot is marked with a letter A B C D or M according to Figure 1 1 Sn Equpert Trusmunen Syncthronitanon o Mr ER M aly ll ET nie This screen is used to view the equipment status in particular e inconsistencies between configuration and composition each slot includes the name of the expected card top left and the name of the inserted card in the middle red coloured if necessary alarmed modules framed red in the case of a major alarm yellow for a minor alarm modules configured out of monitoring are represented greyed modules configured out of service include a cross to signal this administrative status Installation and User Guide N56717020101 Page A1 26 No reproduction or communication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING This screen is also used to activate the common functions of the equipment such as the synchronization safety traffic information etc by clicking on a function in the menu bar see tree structure of the general menu Figure 1 10 access the functionalities related to a module in particular for example MSP protection in the case of an ADRIC1 x module double click on the module to be selected t
85. es l aide du bouton poussoir de face avant cet acquittement n intervient qu au niveau des boucles majeure et mineure de sortie RAZ du journal des alarmes et des v nements RAZ des journaux qualit 15 mn i RAZ des journaux qualit 24 h i Reset chaud de l quipement r alis par logiciel la dur e du reset doit tre inf rieure 30s Tableau 2 8 Commandes 2 2 2 4 Fonctions pr d finies A la mise en service les m canismes suivants sont mis en uvre automatiquement e Synchronisation gestion des boucles sortantes de t l signalisations Synchronisation La synchronisation de l quipement local et de l quipement distant est g r e en fonction des sources de synchronisation disponibles de leur qualit et de la priorit qui leur a t attribu e Les sources de synchronisation possibles sont fonctionnement en autonome oscillateur local e 1 extraites de l un des trains STM1 entrants 1 4 possibilit selon le nombre de cartes ADRIC1 x pr sentes dans l quipement T2 une source 2 Mbit s G 703 par module 2 Mbit s d clar et s lectionn e parmi les diff rents acc s 2 Mbit s G 703 3 deux sources externes 2 MHz G 703 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 9 2 EXPLOITATION Les figures ci apr s pr sentent des exemples de synchronisation en fonction du
86. et le protocole PPP se rattache aux ports physiques r alisant des liaisons point point media optique hertzien V11 Guide d installation et d utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page BA 1 ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP A 2 Adressage IP Afin de pouvoir router des paquets au sein d un noeud IP utilise un m canisme d adressage en fonction de l adresse destination contenue dans le paquet il determine en scrutant sa table de routage vers quel prochain routeur il doit envoyer le paquet et il en d duit l interface physique sur laquelle il doit mettre le paquet On utilisera indiff remment les vocables routeur ou quipement par la suite l existe deux fa ons non exclusives pour mettre jour les tables de routage d IP e Utilisation de routes statiques saisies par l op rateur e l utilisation d un d mon de routage tels que RIP RIP2 OSPF ayant la charge de g rer dynamiquement les tables de routage travers le r seau Les adresses IP sont cod es sous la forme de 4 octets et sont repr sent es usuellement sous forme d cimale exemple 135 11 33 115 Une adresse IP se d compose au plus en 3 champs e le champ NET situ gauche e le champ subnet situ au centre e le champ host situ droite La longueur du premier champ d pend de la classe laquelle appartient l adresse
87. g table contains the following fields e destination ip corresponding to the IP address of the equipment or sub network or network that is targeted from the equipment in question e subnet mask sub network mask associated with the IP address defined in destination ip all equipment pieces with this part of their IP address fields defined by 1 bits correspond to the destination ip defined by this same mask that can be attained using this route e next hop ip IP address of the next router in direct connection with the equipment in question to which the packet is to be sent e metric also named cost or distance value from 1 to 15 indicating the number of hops required to reach the equipment corresponding to the destination ip address 16 corresponds to infinite for the RIP routing demon This field may only be used by a routing demon to select a preferential route if there are several different possible routes for a given destination It is possible to always enter 1 for this field in order to simplify if this operation is not required e interf interface number used to reach the next router the IP address of which is next hop ip Rem The declaration of interface IP addresses induces the establishment of implicit static routes to associated SUBNETs So it is not necessary to define static routes to join two equipments of the same SUBNET Rem The equipment IP addresses are the addresse
88. gt gt Les acc s d alimentation PWR et PWRA et ou PWRB peuvent tre connect s simultan ment Le cordon d alimentation ou le transformateur 110 240 48V 60W ne doit pas tre reli la source primaire avant d tre raccord l quipement Le transformateur 110 240 48V 60W doit tre mont loign de toute source de chaleur et aucune traction ne doit tre exerc e sur ses fils de raccordement Guide d Installation et d Utilisation N56717020101 Page B1 4 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE Description des acc s d alimentation PWR Connecteur de type Jack Fusible FAAL250V fusible rapide 4A faible pouvoir de coupure 250V PWRA et PWRB 1 48 B1 2 48 B1 6 OB1 3 R serv 7 OB1 4 48 B2 8 OB2 5 48 B2 9 OB2 ADR 155C Figure 1 2 Raccordement des acc s alimentation Interface d alimentation PWRA PWRB Tension d entr e Une ou deux sources d alimentation 48 V de type TBTS Tr s Basse Tension de S curit Plage de tension autoris e 36 V 60V Plage de tension maximale 36V 72 V Puissance 100 VA maximum Connecteur HE5 9 points male o ole 9 6 000 0 7 R ser O 48B2 NOTA Le blindage du connecteur est reli la masse de l quipement B1 B1 B2 B2 NE NE Reserve ed MEE Interface d alimentation PWR Acc s Raccordement du
89. gt Transmission gt Reception TR REC ports Interface Type Bit rate Standart Encoding Optical fiber Transmit optical power Max receive power Sensibility at 10 garanteed Attenuation Typical range Connector TR Connector REC Connector IC 1 1 L 1 1 S 1 1 or IC 1 2 L 1 2 S 1 2 155 520 Mbit s 15 ppm ITU T G 957 G 958 Not encoded NRZ oingle mode 1300 nm IC1 1 or 1550 nm IC1 2 ITU T G 652 5 to 0 dBm 0 dBm 34 dB O 28 dB with no external attenuator 0 60 km IC1 1 90 km IC1 2 all ceramic FC PC It is possible to use a multi mode optical fiber with diameter smaller than or equal to 62 5 microns The optical budget is then reduced to 25 96 of the optical budget obtained with a mono mode optical fiber The transmission optical fiber is mono mode type and the reception optical fiber is multi mode type 1 3 3 2 Connecting order wire channels EOW and AUX Interface Port synchronous V 11 differential Bit rate 64 kbit s Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 13 1 INSTALLATION AND COMMISSIONING Connector Female 15 way HE5 D DG D HP Od 1 15 0 Rep Not connected 9 B 6 Input for data to send over the STM 1 line and sampled on the NS 10 TOB Transmit mode byte sync output indicating the positioning of bit 1 E
90. h Connection LPT Lower order Path Termination LPA Lower order Path Lower order Path Adaptation VC12 Adaptation VC3 PPI plesiochronous physical plesiochronous physical Interface VC12 Interface VC3 LPOM Lower order Path Overhead Monitor MCF Message Communication Function Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 1 2 OPERATION 2 2 General The ADR155C operation and maintenance are carried out either directly on the equipment through the front panel indicator lights and two engineering management loops loops A and B or from a PC fitted with HTTP navigator or from a network manager using the SNMP protocol 2 3 Operational parameters The operational parameters include the configuration parameters e the maintenance commands or operations these actions are cleared in case of power supply loss the alarms and their severity Confiquration parameters NOTE The functional blocks naming configuration parameters and their default value noted XXXXXX are displayed on HTTP navigator Configuration parameters per functional blocks Default value SPI SDH Physical Interface The Automatic Laser Shutdown function is always enabled equipment global functionality ALS Automatic Laser Shutdown enable MST Multiplex section Termination EBER B2 monitoring configurable in Monitoring or
91. haviour during the changeover from one module to the other the operator should take care to keep identical configurations on both ADR IC1 x cards a warning message appears in case of modification Only the connections are not identical There must be no connections on the Protection module as in all the connections are made to the Working module Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 15 1 INSTALLATION AND COMMISSIONING 1 3 4 Connecting on ADR LAN1 card DR LAN1 STATUS ETH 10 100 HALF FULL LED STATUS HALF FULL Green Red Yellow LED Ethernet interface type ON OFF Card in service Half or Full Duplex ON ON Card in alarm OFF OFF Hardware default fuse ON Full duplex OFF ON Card out of service Flashing Autotest default ETH 10 100 Contact 1 Contact 8 or Yellow LED Ethernet interface bite rate 1 TX_ETH_TIP 5 NC ON 100 Mbit s 2 TX_ETH RING 6 ETH RING ETH 7 NC 4 NC 8 NC NC Reserved Yellow LED link status ON correct link Green LED traffic status ON on reception Figure 1 5 Connecting ADR LAN1 card input ETH Interface Port Traffic Ethernet interface operating at 10 or 100 Mbit s in half duplex or full duplex mode according to the mode used by the interlocutor dynamic adaptation of the Ethernet port on each new log in of the interlocutor Connector Ethernet 10 or 100 Bas
92. he selection arrow is blinking and its specific menu appears see the tree structure of card menus in Figure 1 10 view the own characteristics of a port connections performed configuration of connections alarm states by selecting the relevant connector For each function viewed the configuration parameters operating commands active parameters and alarm states are grouped together on the same screen with the various actions possible being accessible or not by the operator according to his her clearance level The upper edge of the navigator window recalls the equipment IP address the clearance level acquired and if required the slot concerned EQUIPMENT TRANSMISSION SYNCHRONISATION CROSS EVENT LOGS CONNECTION Date and Time Failure hold off on Synchronisation Clear About Inventories time sources Configuration Refresh Help hardware Software Laser Delete Convert Security Names Save Management modifications Upload and LAN Wizard Download Maintenance Maintenance Monitoring Maintenance Monitoring Monitoring Service Monitoring Service Service Expected Card Performance Expected Card Expected Card Performance VC12 Near 1 to 21 Performance Performance VC3 Near VC3 Far VC12 Far 1 to 21 VC12 Near 1 to 21 VC12 Near VC12 Far Board status IP Parameters VC12 Far 1 to 21 VC3 Near VC3 Far Board status Board status RST Near MST Near MST Far ETH port 1 INPUT OUTPUT ports
93. implicites vers les SUBNETs associ s Il n est donc pas n cessaire de d finir des routes statiques pour joindre deux quipements d un m me SUBNET Hem L quipement a pour adresses IP les adresses de ses interfaces ou ports configur s Le gestionnaire ne connait qu une seule adresse IP par quipement On parle donc fr quemment de l adresse IP d un quipement pour d signer l adresse renseign e dans la base de donn es du gestionnaire C est l adresse du port par lequel l quipement dialogue normalement avec le gestionnaire Hem Pour exploiter un quipement via un PC et une interface Ethernet il est n cessaire de modifier l adresse IP du PC d exploitation pour qu il appartienne au m me SUBNET que l interface Ethernet qui sert se connecter au r seau l est conseill de laisser libre le num ro de HOST 1 sur chaque SUBNET c d de commencer num roter les quipements partir du num ro de HOST 2 Le PC prendra ainsi toujours une adresse IP de type NET SUBNET 1 Hem Il est possible de d finir un routeur par d faut option parfois disponible auquel sera transmis tout paquet ne pouvant pas tre rout gr ce la table de routage Guide d installation et d utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page BA 3 ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP La figure suivante donne un exemple de r seau IP et des tables de routage associ
94. isation N56717020101 Page B2 12 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION D fauts et Alarmes Les tableaux ci apr s donnent les valeurs par d faut des gravit s associ s aux d faillances Alarmes D nomination Gravit SPI Interface physique SDH SDH Physical Interface Emission en d faut Transmit Fai Terminaison de section de regeneration Regenerator Section Termination F LO Perte de trame durant plus de 1 a 3ms majeure Loss Of Frame MST Terminaison de section de multiplexage Multiplex section Termination EBER B2 Taux d erreurs 10 sur les octets B2 majeure SD B2 oignal d grad calcul partir des octets B2 mineure Signal Degrade B2 MS AIS oignal d indication d alarme n ant Alarm Indication Signal MS RDI Indication d alarme distante mineure Remote Defect Indication MSP Protection de section de multiplexage Multiplex Section Protection PAM Non concordance des octets K2 mis et recus mineure Protection Architecture Mismatch SCM Non concordance entre les indications des mineure canaux secourir Selector Control Mismatch OTM Incoh rence de protocole mineure Operation Type Mismatch MSA Adaptation de section de multiplexage Multiplex Section Adaptation Signal d indication d alarme d unit administrative Administrative Unit Alarm Indication Signal Perte de pointeur d unit administ
95. ite to register faults This function requires each site to transmit to the central site an alarm presence message This messages which corresponds to remote monitoring loopback 1 or 2 Local user input 1 or 2 is transmitted in the S1 byte To link this message to equipment s alarms the outputs of the A and B loops Local user outputs A and B should be connected to remote monitoring loops 1 and 2 Local user input 1 or 2 respectively Data chaining in a bus or ring type network architecture is provided by OR function validation between the data received Far user inputs 1 et 2 via S1 STM1 West and 51 STM1 East and local data for each site in the network At the central site equipment OR function validation between the data received Far user inputs 1 and 2 via S1 STM1 West and S1 STM1 East and local data Local user input 1 or 2 and local alarm enables local alarm loopbacks to be activated Local user outputs A and B To configure the remote loopback function the following parameters should be programmed Line remote loopback and central site The Figure 2 3 gives an example of remote management of the local outgoing loops according to the equipment connections B Local user outputs A Local user outputs Acivation of local EAST WEST EAST ps d S1 state of local user LAM inputs 1 and 2 folowing activation of local user 1 outputs A or B Ne pod i ee alarms 3 or local user Hy inp
96. l ADR IG Gard TR and REC G 957 and G 958 STM 1 IC1 1 or IC1 2 Optical Laser class 1 Dangerless aonana 5 EE G 703 2 Mbit s Ports The 19 subrack must be mounted only in racks with a bottom part that is closed or fitted with a class V1 or HF1 or better air filter or that stand on a non flammable floor Safe earth requirement This equipment must be installed only by skilled personnel For compliance the protective earth terminal must be connected to a safe earth with an impedance Z of less than 5 Ohms Handling precaution For any work to be carried out inside the equipment an antistatic wrist strap must be worn Lithium Battery Warning If the battery is incorrectly replaced there is a risk of explosion Only replace with same type battery or equivalent type recommanded by the manufacturer Dispose of used battery according to manufacturer instructions In ADR155C battery replacement may only be done by return Supply Support Department Safety Extra Low Voltage Circuit Installation and User Guide N56717020101 Page A0 2 Reproduction and communication in any form prohibited without the written permission of E CONTENTS CHANGE LIST SECTION Installation and user guide PORTS SECURITY LEVEL CONTENTS 1 INSTALLATION AND COMMISSIONING eeereeeeee nennen nennen 1 1 General 1 2 Subrack installation 1 3 Connecting ports 1 3 1 Conne
97. le constructeur Mettre au rebut les batteries usag es conform ment aux instructions du fabricant Dans l ADR155C le remplacement de la pile ne peut tre effectu que par retour SAV Circuit Tr s Basse Tension de S curit Guide d Installation et d Utilisation N56717020101 Page B0 2 Reproduction et communication interdites sans autorisation crite de la SAGEM SA TABLE DES MATIERES REPERTOIRE DES MISES A JOUR 0 2 SECTION A Installation and user guide A0 1 to AA 6 SECTION B Guide d installation et d utilisation BO 1 BA 6 NIVEAUX DE SECURITE DES ACCES TABLE DES MATIERES 1 INSTALLATION ET MISE EN SERVICE nenne 1 G n ralit s 2 Installation du chassis 3 Raccordement des acc s 3 1 1 1 1 3 1 Raccordement de l alimentation 1 3 2 Raccordements sur la carte m re 1 3 3 Raccordement sur le module ADR IC1 x 1 3 4 Raccordement sur le module ADR LAN 1 3 5 Raccordement sur le module ADR 21E120 1 3 6 Bandeau de raccordement 75 Q 1 4 Mise en service 1 4 1 Configuration n cessaire 1 4 2 Param trage de la fonction communication 1 4 3 Utilisation du navigateur HTTP Figure 1 1 Installation du ch ssis ADR155C Figure 1 2 Raccordement des acc s alimentation Figure 1 3 Raccordement des acc s sur la carte m re Figure 1 4 Raccordement sur le module ADR IC1 x Figure 1 5 Raccordement
98. les tant accessibles ou non l op rateur selon son niveau d habilitation Le bord sup rieur de la fen tre du navigateur rappelle l adresse IP de l quipement le niveau d habilitation acquis et si besoin l alv ole concern e EQUIPMENT TRANSMISSION SYNCHRONISATION CROSS EVENT LOGS CONNECTION Date and Time Failure hold off on Synchronisation Clear About Inventories time sources Configuration Refresh Help hardware Software Laser Delete Convert Security Names Sg Management modifications Upload and LAN Wizard Download Maintenance Maintenance Monitoring Maintenance Monitoring Monitoring Service Monitoring Service Service Expected Card Performance Expected Card Expected Card Performance VC12 Near 1 to 21 Performance Performance VC3 Near VC3 Far Far F 11021 VC12 Near 1 to 21 VC12 Near VC12 Far Board status IP Parameters VC12 Far 1 to 21 VC3 Near VC3 Far Board status Board status RST Near ETH port MST Near VST Far E1 INPUT OUTPUT ports Protection E1 INPUT OUTPUT ports Board status TR REC ports EOW port AUX port Figure 1 10 Arborescence des menus Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 27 1 INSTALLATION ET MISE EN SERVICE Guide d Installation et d Utilisation N56717020101 Page B1 28 Reproduction et communication interdites sans autorisation crite de
99. lisation du d mon de routage RIP RIP est un d mon de routage permettant de s affranchir d une partie des tables de routage statique Le r seau doit tre d coup en AUTONOMOUS SYSTEMs ou AS ayant chacun un num ro de NET diff rent Chaque AS est un domaine de routage RIP et doit tre limit une distance de 15 bonds au maximum entre deux quipements devant s changer des paquets au sein de cet AS On tient compte de la distance maximale pour inclure le pire cas de s curisation du r seau Ces AS sont disjoints entre eux au sein RIP et reli s par des r seaux d isolement constitu s chacun d une simple liaison Ethernet ou point point Chaque r seau d isolement a son propre num ro de NET Les interfaces d quipements appartenant un r seau d isolement doivent tre filtrantes option de filtrage RIP activ e sur ces interfaces c d qu elles interdisent l exportation des mises jour automatiques des tables de routage RIP Ces quipements ayant une interface filtrante sont dits border Au sein d un AS tous les quipements doivent avoir leur d mon de routage RIP activ A l int rieur de chaque AS chaque liaison reliant deux quipements est d crite par une valeur de SUBNET propre Les routages d un AS vers un autre AS via un r seau d isolement sont d crits a l aide de routes statiques Dans l exemple pr sent ci dessus le NET 128 1
100. mble des d fauts d tect s Ce m canisme de corr lation mis en oeuvre chaque changement des informations collect es permet d liminer les d fauts qui sont induits par d autres d fauts afin de faciliter la recherche et la localisation de panne Les tableaux suivants d finissent les d fauts qui sont masqu s par chaque d faut d tect dans le syst me L gende Le d faut consid r sur la ligne courante est masque par le d faut de la colonne courante ex Le d faut 3 LOF est masqu par le d faut 2 LOS Corr lation des d fauts STM1 DEFAUTS DEFAUTS LOS LOF als som B2 T T T AIS MS AIS ach _5 SbB2 6 RDI MS RDI LE OR yx Corr lation des d fauts AU Les d fauts AU sont masqu s par les d fauts STM1 LOS LOF et AIS MS AIS Le d faut TU LOM est filtr si aucune connexion VC12 n est configur e sur ce STM1 DEFAUTS DEFAUTS m F ups Ei su _ eT AU AIS AU LOP Lt I _ 3 UNEQ VC4 UNEQ RDI VC4 RDI eg Guide d Installation et d Utilisation N56717020101 Page B2 16 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Corr lation des d fauts TU VC TU AIS LP UNEQ LP RDI et LP SLM sont masqu s par les d fauts STM1 LOS LOF et AIS MS AIS et par les d fauts AU AU LOP AU AIS UNEQ VC4 UNEQ et TU LOM TU LOP est masqu par les d f
101. mmunication interdites sans autorisation crite de SAGEM SA Page B2 3 2 EXPLOITATION Valeur par d faut Param tres d exploitation en fonction des blocs fonctionnels LPC Connexion de conduit d ordre inf rieur Lower order Path Connexion service SNCI Autorisation de r versibilit par conduit retour apr s une dur e WTR sur la liaison normal lorsque le d faut SF ou SD ayant entrain la commutation a disparu Revertive P riode WTR Wait Time to Restore commune tous les conduits en mode r versible temporisation de retour sur la liaison normale configurable de O 15mn par pas de 1s WTR Persistance des d fauts SF et SD par conduit configurable de O a 10s par pas de 100ms Hold off time LPT de conduit d ordre inf rieur Lower order Path Termination Etiquette signal VC12 transmise attendue et recue Label Transmitted 000b absence de connexion ou 010b asynchrone en pr sence de connexion non configurable par l op rateur Expected valeurs possibles 001b quip sans sp cification ou 010b asynchrone Received Seuil SD V5 VC12 configurable de 10 10 pour VC12 SD V5 threshold Module ADRLAN Etiquette signal VC3 i transmise attendue et re ue Label Transmitted non configurable Expected non configurable Received D bit Forcage du debit de l acc s Ethernet 10 Mbit s Le d bit est
102. munication without the written consent of SAGEM SA 1 INSTALLATION AND COMMISSIONING Open a session and enter your password to parameterize the communication function it is indispensable to have supervisor rights NOTE By default on the first commissioning the password is empty The following menu appears di gt S l TT Annit5c refresh ESC previous d 1 main men MEK configuratisn Htatic routes cunfiguratiaor Display routing informations Benner squipmant oq out Cheiee 7 gt T Ent d EUpBIWimacr Level W 20944 nas Ha LT To select a command type the command number in Choice text zone and press ENTER key to validate your choice Choice 1 Configuration of communication interface eS CIE Um Annit5c BEACE z rmfrmeah previous i main mun EHTERFAZCEN DCC2 Dpi nl EnEgtsAdmir s d i ma HE t Bip af dept t Path RIP ee pee eee es ee eee 220 0000 000 010 235 000 2030 000 000 001 235 000 000 000 000 000 000 BNG OO0 000 000 000 000 000 000 000 000 000 000 000 DUC CG COU GOU UB D OU 000 Obed COU JUC OCS 0O00 000 000 000 00 000 000 MODIFY INTERFACE PARAMETERS j0 Eth l Erbl 2 EPPZ
103. n 19 rack on either side of the subrack Clip on either side of the rack two M6 cage nuts item 1 position the 19 subrack back in front of the rack e Slide the 19 subrack until attaching brackets are in contact with uprights opposite the 4 cage nuts and then secure the subrack with 4 M6x12 hex head screws item 2 Installation in an ETSI rack The installation of the subrack in ETSI rack is identical with that in 19 rack In this case use the set of attaching brackets specific for mounting in ETSI rack Installation of cards RECALL Prior to any operation on the cards the operator must be provided with an antistatic bracelet ADR155C slots are non dedicated However in order to make wiring easier and ensure the homogeneity among sites it is advisable to proceed as follows position the tributary cards from C clockwise position the agregate cards from D counter clockwise check the ventilation module presence in its reserved slide Secure each card through screws of Torx type 6 branch star using a suited screwdriver Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 3 1 INSTALLATION AND COMMISSIONING 1 3 Connecting ports The connections to be performed on the equipment depend on the configuration chosen On the power supply card poser supply ports PWR or PWRA and or PWRB On the subrack motherboard strip
104. n des blocs fonctionnels Valeur par d faut Equipement Suite Alarmes Gravit des alarmes Voir tableaux 46 TW 2 9 2 11 La gravit de chaque alarme est configurable s par ment avec les attributs SS suivants Majeur majeur invers mineur mineur invers n ant n ant invers Persistance des alarmes Persistance pour l apparition X 1 3 10 ou 30s Persistance pour la disparition Y 1 3 10 ou 30s oo D port des boucles de t l signalisation 1 et 2 valid ou utilisation des bits 1 4 de l octet S1 oite central oui non Autorisation d mission de traps vers la gestion d claration des adresses des gestionnaires 10 adresses possibles Tables des routes statiques configur es Mise en service des ports Ethernet PPP1 PPP2 PPP3 ou PPP4 Activ d sactiv port par port D sactiv Adressage des ports port par port Adresse IP de l interface Masque de sous r seau Adresse IP de destination interface PPP seulement Chemins de gestion port par port PPP seulement Au choix MNGT DCC1 A DCC1 B DCC1 C DCC1 D Non configur s Routage RIP valid ou non port par port Tableau 2 6 Param tres de configuration 6 6 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 7 2 EXPLOITATION Commandes ou op rations de maintenance Commandes de surveillance en fonction de
105. nction Figure 1 9 presents the available resources and various configurations possible for the communication function Connect COMM port of the equipment to a COM port not used on the PC with VT100 emulation Power the PC on Start the Hyper Terminal application on the first use proceed as follows connect COMM port of the equipment to a COM port not used on the PC power the PC on Select in succession from Windows desktop the Start Programs Accessories and HyperTerminal command buttons choose the icon representative of the HyperTerminal application description window for the connection appears give a name for the connection and validate your choices e a new window appears choose that PC COM port which is connected to the equipment and validate your choice e a new window appears configure the port parameters as indicated below and validate the programming Bits per second 19200 Data bits 8 Parity no parity e Stop bits a Flow control none save the connection Save command in the application File menu NOTE On the next opening of Hyperterminal application choosing the connection icon will be enough to be logged on the equipment On the equipment power up the operating menu appears To exit the Hyperterminal application select Quit command from File menu Installation and User Guide N56717020101 Page A1 22 No reproduction or com
106. nd AUX LED STATUS 8 1 Green Red 15 GO 000000 9 ON OFF Card in service re ON ON Card in alarm 2 i TA 9 TB OFF OFF Hardware default fuse d OFF ON Card out of service 3 TOF PA 10 TOF PB Flashing Autotest default 4 RA 11 RB 5 ROF PA 12 ROF PB 6 R64A 13 R64 B 7 T64 14 T64 B 8 GND 15 NC Version 1 STM1 transmission port STM1 reception port DR p 1 GES PS GES PS TATUS EOW and AUX LED STATUS 8 1 Red 15 9 ON OFF Card in service 1 NC ON ON Card in alarm SS L 9 TB OFF OFF Hardware default fuse 3 TOF PA 10 TOF PB OFF ON Card out of service 4 RA 11 Flashing Autotest default 5 ROF PA 12 ROF PB 6 R64 A 13 R64 B 7 T64 A 14 T64 B 8 GND 15 NC Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 12 Version 2 Figure 1 4 Connecting ADR IC1 x card inputs NC Reserved 1 INSTALLATION AND COMMISSIONING 1 3 3 Connecting on the ADR IC1 x card Each ADR IC1 x module provides connection for an STM1 interface TR transmission port and REC reception port two order wire channels at 64 kbit s named EOW and AUX which by default are conveyed in E1 and F1 bytes of the SOH respectively 1 3 3 1 Connecting STM1 interface Remove the contact protection connector Connect STM 1 interface to front panel FC PC connectors
107. nde les indicateurs VC12 REI ne sont pas pris en compte dans les calculs calcul et d termination des tats ES Errored Second seconde erron e SES Severely Errored Second seconde gravement erron e BBE Background Block Error bloc erron r siduel et UAS UnAvailable Second seconde d indisponibilit pour chaque point de surveillance laboration pour chaque point de surveillance des compteurs 15 minutes et des compteurs 24 heures BBE ES SES et UAS D termination des tats qualit ES SES et UAS Pour chaque point de surveillance les tats qualit sont les suivants ES Errored Seconds nombre de secondes avec au moins une erreur d tect e dans une p riode de 1s ou un d faut SES Severely Errored Seconds nombre de secondes gravement erron es Une SES est une seconde pour laquelle le nombre d erreurs d passe un seuil d fini ou pendant laquelle au moins un d faut est d tect Point de surveillance Seuil de d claration d une SES RS octet B1 pour local 2400 MS octet B2 pour local et MS octet M1 pour distant 2400 VC3 pour local ep O VC12 octet V5 pour local UAS UnAvailable Second nombre de secondes d indisponibilit BBE Background Block Error nombre de blocs erron s hors SES Guide d Installation et d Utilisation N56717020101 Page B2 18 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Ela
108. network of last quipment yes Link established Optical measurements MSP protection check 24 H link Performance Equipment operational constitution of installation file Configuration Save Figure 1 8 Commissioning procedure for ADR155C network Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 19 1 INSTALLATION AND COMMISSIONING 1 4 NOTE Commissioning The equipment can be operated from a PC fitted with VT100 emulation and HTTP navigator its minimum configuration is defined in section 1 4 1 A local terminal with VT100 emulation is indispensable during the first commissioning in order to be able to access the equipment via the management function however this terminal only enables the communication function to be parameterized Procedure On the first commissioning the equipment scans its constitution and considers it as the expected configuration in service not monitored It is thus advisable to insert the traffic cards before power up in order to speed up the commissioning owitch on the power supply connected to the equipment The equipment conducts self tests e When self tests have run correctly the ON indicator light is illuminating n the opposite case an indicator flashing code defines the faulty self test contact the hotline Parameterize the communication interface using the VT100 see 1 4
109. ns autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE Ouvrir une session et entrer votre mot de passe pour param trer la fonction de communication il est indispensable de disposer des droits supervisor NOTE par d faut lors de la premi re mise en service le mot de passe est vide Le menu ci dessous apparait di gt Hpp eal ADRESSE SPACE rmfrmeah ERC previous d main mum Interfaces configuration Htatic routes configuration Display routing informations Rsnact ad pace Los aut BUupsEvIlacr laua EEE nan Ha Mr sm Taura Pour s lectionner une commande taper le num ro de la commande dans la zone de texte Choice et appuyer sur la touche ENTER pour valider votre choix Choix 1 Configuration des interfaces de communication 1095 Appa l anal l Fi Annit5c SPACE rmfrmah ERC previous d main mene ZHTERFAZEBN DCCi pi pi EnrgtsAdlmmir ip maak t Bip af dent t Bath RIP ee M R ee eee 220 000 000 010 295 000 000 M000 O30 000 000 00L 25 5 000 000 000 000 000 000 OD DOC 0010 OD 000 000 000 000 000 000 000 000 QUE DO DOUD COUE I DUU OOU JUC Ole COU JUC ob OO0 000 000 000 1 000 000 0000 O00 00 000 000 MODIFY INTERFACE PARAMETERS j0 Eth l Erbl 2 EPPZ i
110. nsmitted UNNAMED VC3 CRC7 not configurable not treated in reception SETS Synchronous Equipment Timing Source Quality level of synchronization sources Quality PRC Primary Reference Clock SSUT Synchronisation Supply Unit Transit SSUL Synchronisation Supply Unit Local SEC Synchronisation Equipment Clock DNU Do Not Use SSMB Synchronisation Status Message Byte synchronization quality carried out in S1 Byte Use of synchronization status messages SSM SSM TO priority Table according to enabled sources 1 possible values 1 to 8 for all sources 2 Mbit s port number chosen for T2 T2 Tributary port 1 port per enabled 2 Mbit s card Revertive authorization common to all sources return after a WTR time delay to the working link when the fault SF or SD causing the switch has disappeared Revertive T3 PRC T1 SSMB T2 SEC T4 SEC Wait Time to Restore WTR period in revertive mode period following restoration of nominal operation configurable from O to 30mn by one second step WTR Source selected for T4 Active source TO SASE mode control enable or disable disabled T3 source selection for SASE mode T3 1 or T3 2 Quality level for T4 PRC PRC Primary Reference Clock SSUT Synchronisation Supply Unit Transit SSUL Synchronisation Supply Unit Local SEC Synchronisation Equipment Clock Table 2 4 Configur
111. nterface RXCLKP B A receive clock input RXP B A input for data received B8 B2 over the P interface Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A1 9 1 INSTALLATION AND COMMISSIONING 1 3 2 3 G 703 2 Mbit s Synchronization port SYNC Interface Ports Two G 703 2MHz external synchronization inputs T3 and one G 703 2MHz clock output T4 compliant with ITU T G 703 Recommendation S 10 3 for input port S tab 10 for output port Bit rate 2 048 Mbit s 50 ppm Impedance 120 balanced Connector Female 9 way HE5 120 5 o 0 O O QV 741 7 Input T3 1 hot point Input T3 1 cold point ING Reserved O NOTA The shielding of the connector case is connected to the subrack front panel ground NC Caf E 383 2 Es cx NN 8 WEE ER WS BECH WER 1 3 2 4 G 703 21 x 2 Mbit s traffic port E1 INPUT and E1 OUTPUT Interface ports 21 x 2 Mbit s traffic ports compliant with the ITU T G 703 Recommendation 6 3 for input port tab 6 for output port Bit rate 2 048 Mbit s 50 ppm Code HDB3 Impedance 120 balanced Connector SUB D HD female 44 pins supporting L907 cable 21 ports This interface uses two connectors E1 INPUT connector for inputs named RX and E1 OUTPUT connector for outputs named TX 15 000000000000000 11 30 0000000000000001 16 44V
112. on interdites sans autorisation crite de la SAGEM SA B2 10 B2 11 B2 2 B2 7 B2 8 B2 9 B2 13 B2 15 B3 1 B3 2 B4 1 B4 2 BA 1 BA5 BA 1 BA 2 BA 3 BA 3 BA 5 1 1 1 INSTALLATION ET MISE EN SERVICE 1 INSTALLATION ET MISE EN SERVICE G n ralit s L ADR 155C est un multiplexeur add drop optique STM 1 qui permet de construire des liaisons point point STM 1 des anneaux STM 1 ou des r seaux maill s avec protection de conduit SNC ou de ligne MSP r alisant ainsi le transport de liaisons 2 Mbit s Ethernet STM 1 L ADR 155C peut tre utilis en Multiplexeur terminal STM 1 avec une capacit maximale de 63 VC12 et possibilit de protection 1 1 H p teur STM 1 aptitude r g n rer 2 VC4 Multiplexeur STM1 insertion extraction avec une capacit maximale de 4 STM 1 et insertion extraction de 21 VC12 Point d interconnexion de LAN en fonction exclusive jusqu 3 liaisons d port es totalisant VC3 utilis s Cet quipement est g r partir d un navigateur HTTP soit localement via son interface Ethernet d di e e soit distance par t l exploitation e O partir du gestionnaire de r seau IONOS ANM dans ce dernier cas l utilisation du protocole SNMP permet galement la supervision globale du r seau L utilisation d un terminal local avec emulation VT100 est n cessaire lors de la premi re mise en service pour la configuration des p
113. onfiguration i Fonction de communication de message Message Communications Function Mode de fonctionnement de l interface MNGT CO codirectionnel ou CT contra directionnel maitre P port configuration O d Equipement Choix d une classe d habilitation Administrateur Exploitant Observateur Un mot de passe par classe d habilitation Pas de mot de Seul l administrateur peut modifier le mot de passe passe Date et heure de l quipement 01 01 1970 Etat des alv oles A B C D alv ole configur e avec une carte attendue A C ADR21E120 B D ADRIC1 x Surveillance Surveillance des modules No Monitoring Une carte non surveill e est indiqu e dans la vue quipement le fait de ne pas surveiller une carte inhibe toute la gestion de la qualit et des d fauts relatifs celle ci carte et acc s Surveillance du ch ssis Monitoring Surveillance des acc s Monitoring Le fait de ne pas surveiller un acc s inhibe toute la gestion des d fauts pour acc s relatifs ce dernier physiques No Monitoring pour performance Mise en hors service d une carte Service La carte est ignor e par la fonction de gestion Tableau 2 5 Param tres de configuration 5 6 Guide d Installation et d Utilisation N56717020101 Page B2 6 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Param tres d exploitation en fonctio
114. orme 255 255 255 0 255 255 0 0 255 0 0 0 etc le nombre de bits z ro de la partie droite du masque d finit la longueur du champ HOST ex pour l adresse 40 2 2 2 associ e au masque 255 255 255 0 le champ NET prend la valeur 40 le champ SUBNET la valeur 2 2 et le champ HOST la valeur 2 Guide d installation et d utilisation N56717020101 Page BA 2 Reproduction et communication interdites sans autorisation crite de SAGEM SA ANNEXE A CONSTRUCTION DU PLAN D ADRESSAGE D UN RESEAU IP A 3 A 4 Plan d adressage Un r seau global IP doit tre subdivis en N r seaux ayant chacun un num ro de NET Au sein de chaque r seau chaque liaison physique point a point ou multi point a son num ro de SUBNET propre Chaque equipement reli a cette liaison 2 pour une liaison point a point N pour un segment Ethernet a son num ro de HOST propre En fonction du nombre d quipements et de liaisons on utilisera des adresses de classes A B ou C et des SUBNETSs cod s sur un ou deux octets En conclusion chaque interface d un noeud du r seau va tre associ obligatoirement un couple constitu d une adresse IP et son masque de SUBNET Utilisation des tables statiques Dans le cadre de l utilisation de tables statiques chaque noeud du r seau doit avoir sa table de routage renseign e afin qu il puisse router correctement les paquets recus Toute route IP d une table de rout
115. ould be declared out of service Each module can be extracted or inserted without acting on other modules or their wiring Only the traffic of the concerned module is disturbed Procedure The procedure described below can apply unless otherwise specified to all the cards in the equipment 1 Put the card concerned no service from HTTP navigator 2 Remove the external connections performed on the card front side NOTE When the external optical fibers are disconnected reinstall the protective covers on connectors 3 Screw off the TORX screws located on the front side using the suited screwdriver and unplug the card 4 Extract the card complying with the measures of protection against electrostatic discharges NOTE For any card handling the operator must wear an anti static bracelet well tight around the wrist and earthed 5 Package the extracted card in an anti static bag 6 Take the new card out of its anti static bag 7 Carefully insert the card into its cell complying with the measures of protection against electrostatic discharges and secure it with the TORX screws 8 Hestore connections on the card front side NOTE For the optical STM1 card remove the protective covers from connectors To clean the optical connectors use a pressurized air aerosol 9 Configure the card if necessary and put it into service Replacing the fan module The ADRFAN module consists of two redundant fans in order to ensure
116. r ADRLAN 1 card Right cable male male Right cable male male 55 670 421 Crossover cable male male 55 670 422 Right cable male female 55 670 610 Right cable male female 55 670 423 55 670 424 LOOPS port 6 013 628 Hemote indication remote control and station alarm 6 013 261 loops 6 013 161 6 013 262 TR or REC ports 6 491 366 FC PC FC PC optical Jumper on ADRIC1 x card 6 491 367 6 491 369 6 491 370 6 491 371 6 491 372 55 670 481 55 6 0 495 55 670 752 AUX or EOW ports 6 013 632 Auxiliary channel and orderwire channel on 6 013 266 ADRIC1 x card 6 013 176 6 013 267 Installation and User Guide N56715070103 Page A3 2 No reproduction or communication without the written consent of SAGEM SA 4 SPECIFICATIONS 4 SPECIFICATIONS Optical specifications m AU 2 IC1 12L1 1 S1 1 or 101 2 L1 2 S12 155 520 Mbit s 20 ppm ITU T G 957 G 958 Not encoded NRZ Single mode 1 300 nm IC1 1 or 1 550 nm IC1 2 ITU T G 652 a Interface type It is possible to use a multi mode optical fiber whose diameter is smaller than or equal to 62 5 microns O 28 dB with no external attenuator O 70 km IC1 1 100 km IC1 2 All ceramic FC PC Guaranteed attenuation oical range O3 m 02 UJ Q E22 10 1515 0191312 D VIL oO 125 lei S C 2 Mechanical specifications C Width Debth Weight Protection Class IP 19
117. raccordement des quipements Entr e de synchronisation externe a 2 MHz T3 Qualit PRC Priorit 1 Acc s STM 1 T1 c Acc s STM 1 T1 c Qualit DNU Qualit DNU Priorit 2 Priorit 2 ADR155C 1 ADR155C 2 Synchronisation T1 C TO T3 SSM PRC T1 C TO T3 ADR155C1 interne Sortie de l horloge 2 MHz T4 TO T3 ADR155C1 ADR155C 3 SSM PRC Sortie de l horloge a 2 MHz 4 TO Tic Synchronisation d autres quipements Figure 2 1 Synchronisation partir de l entr e de synchronisation externe 2 MHz T3 Acc s 2 Mbit s T2 Qualit SEC Priorit 1 Acc s STM 1 T1 c Acc s STM 1 T1 c Qualit DNU Qualit DNU Priorit 2 Priorit 2 ADR155C 1 ADR155C 2 Synchronisation T1 C T0 T2 SSM SEC T1 C TO T1 c Ouest GE TO T1 C Ouest ou T2 ADR155C1 TO TB Sortie de l horloge 2 MHz T4 TO T1c Ouest Synchronisation d autres quipements SSM SEC ADR155C 3 Sortie de l horloge 2 MHz 4 TO Tic Synchronisation d autres quipements NOTA La synchronisation se fait sur l acc s 2 Mbit s de l ADR155C qui est mis en service le premier ADR155C local dans l exemple Figure 2 2 Synchronisation partir d un acc s 2 Mbit s Guide d Installation et d Utilisation N56717020101 Page B2 10 Reproduction et communication interdites sans autorisation crite de la
118. rative majeure Administrative Unit Loss Of Pointer E D Surveillance de pr fixe de conduit d ordre sup rieur vath Overhead Monitor Indication d alarme distante sur conduit d ordre mineure sup rieur High Order Path Remote Defect Indication T O HO UNEQ Etiquette du conduit d ordre superieur non quip High order Path Unequipped T J d Tableau 2 9 Alarmes et gravit 1 3 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 13 2 EXPLOITATION Alarmes D nomination Gravit HPT Terminaison de conduit d ordre sup rieur Higher Order Path Termination n ant HO SLM Erreur sur l tiquette C2 du signal sur conduit d ordre sup rieur High Order Path Signal Label Mismatch HO RDI G1 Conduit d ordre sup rieur Indication d alarme mineure distante High Order Path Remote Defect Indication HO UNEQ Etiquette du conduit d ordre sup rieur non quip n ant High Order Path UNEQuipped HPA Adaptation de conduit d ordre sup rieur Higher Order Path Adaptation TU LOM Perte de multitrame d unit s d affluents Tributary mineure Unit Loss Of Multitrame TU AIS Signal d indication d alarme d unit s d affluents n ant Tributary Unit Alarm Indication Signal TU LOP Perte de pointeur d unit s d affluents mineure Tributary Unit Loss Of Pointer
119. rd is ignored by the management function Table 2 5 Configuration parameters 5 6 Installation and User Guide N56717020101 Page A2 6 No reproduction or communication without the written consent of SAGEM SA 2 OPERATION Configuration parameters per functional blocks Default value Equipment Continue Alarms Do Alarm severity See tables The severity of each alarm is configurable individually with the following 2 9 to 2 11 attributes major major reverse minor minor reverse none none reverse Alarm Persistence Persistence for the appearance X 1 3 10 or 30s X 2 3s Persistence for the disappearance Y 01 3 10 or 30s Y Loge Mismatch of remote indication loops 1 and 2 validated or not Not validated use of bits 1 to 4 of byte S1 35 No Centre site yes no Rum Authorization to transmit traps to the management declaration of the manager addresses 10 addresses possible Tables of configured static routes Not configured Putting ports into service Ethernet PPP1 PPP2 PPP3 or PPP4 Enabled Disabled port by port Disabled Port addressing port by port Interface IP address Subnetwork mask Destination IP address PPP interface only Management paths port by port PPP only Options MNGT DCC1_A DCC1_B DCC1_C DCC1_D RIP routing validated or not port by port Not validated Table 2 6 Configuration parameters 6 6 Installation and User Guide N5671702
120. re le PC sous tension Lancer l application Hyper Terminal Lors de la premi re utilisation proc der comme suit raccorder l acc s COMM de l quipement un port COM non utilis du PC e mettre le PC sous tension s lectionner successivement dans le bureau de Windows les boutons de commande D marrer Programmes Accessoires et HyperTerminal Choisir l ic ne repr sentative de l application HyperTerminal une fen tre de description de la connexion appara t donner un nom et choisir une ic ne pour la connexion et valider vos choix une nouvelle fen tre apparait choisir le port COM du PC qui est raccord l quipement et valider votre choix une nouvelle fen tre apparait configurer les param tres du port comme indiqu ci dessous et valider la programmation Bits par seconde 19200 Bits de donn es 8 Parit aucun Bits d arr t St Contr le du flux aucun enregistrer la connexion commande Enregistrer du menu Fichier de l application NOTA Lors de la prochaine ouverture de l application Hyperterminal il suffira de choisir l ic ne de la connexion pour se connecter sur l quipement A la mise sous tension de l quipement le menu d exploitation apparait Pour quitter l application Hyperterminal s lectionner la commande Quitter du menu Fichier Guide d Installation et d Utilisation N56717020101 Page B1 22 Reproduction et communication interdites sa
121. s curisations souhait es protection MSP protection SNC e Choisir la source de synchronisation et modifier ses param tres si n cessaire Modifier si n cessaire les param tres de surveillance et la configuration des alarmes La configuration par d faut des diff rents param tres est donn e au 2 1 1 Effectuer les tests des liaisons STM 1 en respectant le processus d crit la Figure 1 8 L quipement est des lors op rationnel Les alarmes d exploitation peuvent signaler un mauvais raccordement des acces V rifier le raccordement des acc s les alarmes qui correspondent aux acc s raccord s et corriger les probl mes ventuels amp Effectuer une sauvegarde de la configuration REMARQUE Il est possible une fois la mise en service effectu e de raccorder des acc s suppl mentaires 2 Mbit s G 703 Ethernet ou STM1 et d ins rer ou d extraire des cartes sous tension Guide d Installation et d Utilisation N56717020101 Page B1 20 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE Acc s de gestion Application Acces ETH Serveur HTTP 4 acc s Agent SNNP pour Fonction Point to Point Protocole IONOS ANM de routage Fonction de communication sur un ADR 155C Le TPI peut se brancher sur une interface Ethernet quelconque d s lors que le param trage permet d atteindre 1 quipement exploiter ADR A4 p sur
122. s blocs fonctionnels Commande op rateur pour protection MSP Clear Annulation du for age Lockout of Protection Interdiction de protection Forced Switch to Working For age de la commutation sur normal Forced Switch to Protection For age de la commutation sur secours Manual Switch to Working Commutation manuelle sur normal Manual Switch to Protection Commutation manuelle sur secours Commande op rateur pour la s curisation SNC de conduit VC12 ou VC3 par conduit et par ordre de priorit Clear Annulation du forcage Lockout of Protection Interdiction de protection Forced Switch to Working Forcage de la commutation sur normal Forced Switch to Protection Forcage de la commutation sur secours Manual Switch to Working Commutation manuelle sur normal Manual Switch to Protection Commutation manuelle sur secours SETS Source de rythme de l quipement synchrone Synchronous Equipment Timing Source Commande op rateur pour la s curisation Clear Annulation du for age Lockout of Protection Interdiction de protection Forced Switch For age de la commutation Manual Switch to Protection Commutation manuelle sur secours Tableau 2 7 Commandes 1 2 Guide d Installation et d Utilisation N56717020101 Page B2 8 Reproduction et communication interdites sans autorisation crite de la SAGEM SA 2 EXPLOITATION Commandes de surveillance en fonction des blocs fonctionnels Equipement Acquittement des alarm
123. s of its configured interfaces or ports The manager knows only one IP address per equipment So IP address of an equipment is frequently used to refer to the address filled in the manager database This is the address of the port through which the equipment interacts normally with manager Rem To operate an equipment via a PC and an Ethernet interface it is necessary to change the IP address of the operating PC for the PC to belong to the same SUBNET as the Ethernet interface that is used to be connected to the network It is advisable to leave HOST 1 number free on each SUBNET i e to start numbering the equipments from HOST 2 number Thus the PC will always take an IP address of this type NET SUBNET 1 Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page AA 3 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN Note If it is possible to define a default router option sometimes available to which any packet may be transmitted which cannot be routed using the routing table The following figure shows an example of an IP network and routing tables associated with two equipment types It shall be noted that each port of the onboard routing function corresponds to a different SUBNET Block diagram of example TMN architecture 140 1 1 3 140 1 0 2 140 1 0 3 140 1 0 2 F2 128 1 0 1 Ethernet NET 128 1 128 1 0 3 NET 140 1 Fiber Ethernet Es NET 160 1 NET 1
124. sser le ch ssis 19 jusqu ce que les querres de fixation entrent en contact avec les montants face aux 4 crous cage puis le fixer au moyen de 4 vis t te hexagonale M6x12 rep re 2 Installation en b ti ETSI L installation du ch ssis en b ti ETSI est identique celle en baie 19 Dans ce cas utiliser le jeu d querres de fixation sp cifique d un montage en b ti ETSI Implantation des cartes RAPPEL Avant toute intervention sur les cartes l op rateur doit se munir d un bracelet antistatique Les alv oles d un ADR155C sont banalis es Cependant pour faciliter le c blage et garantir l homog n it des sites il est recommand de proc der de la fa on suivante positionner les cartes affluents depuis l alv ole C dans le sens des aiguilles d une montre positionner les cartes r sultants depuis l alv ole D dans le sens inverse des aiguilles d une montre v rifier la pr sence du module de ventilation dans son tiroir r serv Fixer chaque carte au moyen des vis de type Torx de type M3 toile 6 branches en utilisant un tournevis adapt Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B1 3 1 INSTALLATION ET MISE EN SERVICE 1 3 Raccordement des acc s Les raccordements effectuer sur l quipement sont fonction de la configuration choisie Sur la carte d alimentation acc s d alimentation
125. sufficient ventilation when either of them is defective Fan failures are detected on the motherboard by monitoring the power consumed failures are viewed on ADR155C shelf view screen of HTTP navigator if at least one fan is faulty ADRFAN module is framed red major alarm not configurable NOTE The operation of ADRFAN is not continuous its initiation is related to the equipment internal temperature ADRFAN can be extracted it can be replaced at any moment without disturbing the traffic Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 19 2 OPERATION Procedure 1 Screw off the TORX screws located on the front side using the suited screwdriver and unplug the card 2 Extract the card complying with the measures of protection against electrostatic discharges NOTE For any card handling the operator must wear an anti static bracelet well tight around the wrist and earthed Package the extracted module in an anti static bag Take the new module out of its anti static bag Carefully insert the module into its place complying with the measures of protection against electrostatic discharges and secure it with TORX screws Replacing the front panel fuse Procedure 1 Disconnect the power cable or the 110 240 48V 60W transformer from the primary power source Screw off the fuse holder from the power supply front panel Replace the defective fuse with
126. sur le module ADR LAN 1 Figure 1 6 Raccordement sur le module ADR 21E120 Figure 1 7 Bandeau de raccordement 75 Q Figure 1 8 Processus de mise en service d un r seau d ADR155C Figure 1 9 Exemples de configuration de la fonction de communication Figure 1 10 Arborescence des menus 2 EXPLOITATION BO 2 BO 3 B1 1 B1 28 B1 1 B1 3 B1 4 B1 4 B1 7 B1 13 B1 16 B1 17 B1 18 B1 20 B1 22 B1 22 B1 26 2 1 Pr sentation fonctionnelle B2 1 2 2 G n ralit s B2 2 2 3 Param tres d exploitation B2 2 2 4 Fonctions pr d finies B2 9 2 5 Traitement des alarmes B2 12 2 6 Traitement de la qualit B2 18 2 7 Proc dures de changement de sous ensemble B2 20 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B0 3 Figure 2 1 Synchronisation partir de l entr e de synchronisation externe 2 MHz T3 B2 10 Figure 2 2 Synchronisation partir d un acc s 2 Mbit s Figure 2 3 D port de boucles Rapatriement des alarmes sur un site central Tableaux 2 1 2 6 Param tres de configuration Tableaux 2 7 et 2 8 Commandes Tableaux 2 9 2 11 Alarmes et gravit A 1 Pr ambule A 2 Adressage IP A 3 Plan d adressage A 4 Utilisation des tables statiques 5 Utilisation du d mon de routage RIP Guide d Installation et d Utilisation Nb6717020101 Page B0 4 Reproduction et communicati
127. t 5 ROF PA 12 ROF PB 6 R64 A 13 R64 B 7 T64A 14 T64 B 8 GND 15 NC Version 1 Acc s STM1 mission Acc s STM1 r ception DR IC1 1 pu A pu A TATUS Voyants STATUS 8 1 00000000 15 9 Vert Rouge Allum Eteint Carte en service LENG 2 2 TA 9 TB Allum Allum Carte en alarme 3 TOF PA 10 TOF PB Eteint Eteint D faut mat riel de la carte fusible 4 j RA 11 RB Eteint Allum Carte hors service 5 ROF PA 12 ROF PB Clignotant D faut autotest 6 R64A 13 R64 B 7 T64 A 14 T64 B 8 GND 15 NC NC R serv Version 2 Figure 1 4 Raccordement sur le module ADR IC1 x Guide d Installation et d Utilisation N56717020101 Page B1 12 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE 1 3 3 Raccordement sur le module ADR IC1 x Chaque module ADR IC1 x permet de raccorder un acc s STM1 un acc s mission TR et un acc s r ception REC deux voies de service 64 kbit s appel es EOW et AUX qui par d faut sont transport es respectivement dans les octets E1 et F1 du SOH 1 3 3 1 Raccordement des acc s STM1 Retirer le connecteur protege contacts Raccorder les acc s STM 1 sur les connecteurs FC PC de face avant c Emission Connecteur TR gt R ception Connecteur REC Acc s TR et REC Type d interface D bit Norme Codage Fibre optique Puissance mise Puissance recu
128. t d activer les boucles d alarmes locales Local user outputs A et B Pour configurer la fonction d port de boucles il suffit programmer les param tres D port des boucles par r sultant et Site central La Figure 2 3 donne un exemple de gestion distante des boucles sortantes locales en fonction du raccordement des quipements A B Local user outputs A B Local user outputs OUEST ON EST OUEST EST Acivation de local S1 Ouest re u user inputs 1 tat de Local user 1 ou 2 suite inputs 1 et 2 a activation 1 de local user 1 Activation de outputs A ou B P Local user alarmes 2 e outputs A ou B quipement 3 ou local user By TEE 4 inputs 3 rt 4 4 ADR 155C 2 SITE CENTRAL Local Local user inputs user inputs Local user outputs Acivation de local OUEST user inputs 1 ou 2 suite tat de Local user activation inputs 1 et 2 de local user outputs A ou B alarmes 3 quipement ou local user 4 inputs 3 rt 4 ADR 155C 3 Local user inputs Figure 2 3 D port de boucles rapatriement des alarmes sur un site central NOTA L tat des boucles entrantes Local user inputs 1 4 des boucles entrantes distantes Far user inputs 1 et 2 etdes boucles sortantes Local user outputs A et B peut tre visualis partir du navigateur HTTP Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM S
129. tion de conduit Adaptation de conduit d ordre inf rieur VC12 d ordre inf rieur VC3 PPI Interface physique Interface physique pl siochrone VC12 pl siochrone VC3 Guide d Installation et d Utilisation N56717020101 Reproduction et communication interdites sans autorisation crite de SAGEM SA Page B2 1 2 EXPLOITATION 2 2 G n ralit s L exploitation et la maintenance de l ADR 155C sont r alis es solt directement sur l quipement au moyen des voyants de la face avant et des deux boucles de gestion technique boucles A et B Soit partir d un PC quip d un navigateur HTTP Soit partir d un gestionnaire de r seau par l utilisation du protocole SNMP 2 3 Parametres d exploitation Les param tres d exploitation regroupent les param tres de configuration e les commandes ou op rations de maintenance ces actions sont effac es en cas de perte de l alimentation les alarmes et leur s v rit Param tres de confiquration NOTA La d nomination des blocs fonctionnels les param tres de configuration et leur valeur par d faut not s XXXXXX sont visualis s sur le navigateur HTTP Param tres de configuration en fonction des blocs fonctionnels d faut SPI Interface physique SDH SDH Physical Interface La fonction coupure automatique du Laser est toujours activ e fonctionnalit globale l quipement ALS Automatic Laser Shutdown enable MST Terminaison de s
130. torisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE 1 2 Installation du ch ssis Le ch ssis ADR 155C peut s installer en baie 19 ou en b ti ETSI voir Figure 1 1 Il est constitu d une carte m re situ e dans sa partie inf rieure rep re M de quatre alv oles banalis es rep res A D destin es recevoir les cartes d acc s d un tiroir situ gauche du ch ssis destin recevoir le module de ventilation rep re V d une alimentation rep re P Tous les raccordements s effectuent en face avant soit sur le bandeau du ch ssis soit sur les modules eux m mes Installation en baie 19 Les l ments de fixation du ch ssis en baie 19 querres crous cage et vis de fixation sont fournis dans son emballage L ADR155C poss de un syst me de r gulation thermique par ventilation lors de l installation pr voir un espace suffisant pour la prise d air gauche du ch ssis et un pour l vacuation d air en haut droite du ch ssis Par ailleurs ne pas g ner la convection naturelle d air sur le flanc droit Proc der aux op rations suivantes pr voir un emplacement de 2U dans la baie pour chaque quipement et un espacement de 1U entre les quipements fixer les querres de fixation pour montage en baie 19 de chaque c t du ch ssis clipser de chaque c t de la baie deux crous cage M6 rep re 1 pr senter l arri re du ch ssis 19 face la baie faire gli
131. u 1550 nm 1C1 2 UIT T G 652 Type d interface Fibre optique Ilest possible d utiliser une fibre optique multi mode de diam tre inf rieur ou gal 62 5 microns O 28 dB sans att nuateur externe O 70 km 1C1 1 ou 0 100 km 1C1 2 FC PC tout c ramique Att nuation garantie Port e typique CO SICH o D 5 QIZ10 5 013 1535 D c Caract ristiques m caniques C 19 ou ETSI 300 mm environ 6 ko correspond l IP de la baie utilis e argeur Profondeur Indice de Protection IP Consommation lt 40 W pour un chassis quip de deux cartes ADR IC1 x et deux cartes ADR LAN lt T o C o C x Caract ristiques d environnement ETS 300 119 4 19 ou CEI 297 3 ETSI ETS 300 019 2 3 lt D RV 2 C D 2 Condition climatique CEI 721 1 1993 ETS300 019 part 1 3 class 3 1 3 2 Temp rature de fonctionnement 5 C 45 C Temp rature de fonctionnement 25 C 55 C le MTBF Mean Time Between tendue Failure est sensiblement d grad Temp rature de transport et de 40 C 70 C Humidit relative 8596 DES NF EN 50081 1 NF EN 50082 1 de Juin 1992 et ETS 300 386 1 de 1994 CEM Compatibilit Electro NF EN 55022 1994 Additif A1 de 02 1996 Equipement de classe B NF EN 60950 A4 et A11 ETS 300132 2 l quipement est TBTS o O gt lt D 3 D c C D MIQ D
132. uction et communication interdites sans autorisation crite de SAGEM SA Page B1 7 1 INSTALLATION ET MISE EN SERVICE NOTA Deux LEDs sont associ es au connecteur ETH LED de couleur verte Activity indicateur de l tat du trafic LED de couleur jaune Link indicateur de l tat de la liaison 1 3 2 2 Acc s de gestion et d exploitation Interface COMM Acc s Interface RS232 interconnexion d une console ou mulation au standard VT100 D bit 19200 bauds 8 bits de donn es pas de bit de parit et 1 bit de stop Connecteur Type HE5 9 points femelles 2 9 0 O O 0 6 ee gt gt _x 1 w Poste de donn es pr t Data Set Ready vers ETCD L2 FX de donn es vers ETCD oc PORTS Demande pour mettre Request To Send de ETCD 3 TX Emission de donn es de ETCD EE Pr t a mettre Clear To Send vers ETCD Terminal de donn es pr t Data Terminal Ready de ETCD ___ Ring Indicator non connect _5 GND Masse L ADR155C est vue comme un ETCD Cable de raccordement Voir sch ma ci dessous Cote equipement COMM Cote VT100 ou PC e Connecteur HE5 Connecteur HE5 9 points m les 9 points femelles Sch ma de cablage Guide d Installation et d Utilisation N56717020101 Page B1 8 Reproduction et communication interdites sans autorisation crite de SAGEM SA 1 INSTALLATION ET MISE EN SERVICE Interface
133. ure 2 2 Synchronization from the 2 MHz port A2 10 Figure 2 3 Remote loopback function registering alarms on central site A2 11 Tables 2 1 to 2 6 Configuration parameters A2 2 to A2 7 Tables 2 7 to 2 8 Commands A2 8 to A2 9 Tables 2 9 to 2 10 Alarms and severity A2 13 to A2 14 A3 1 to A3 2 A or elle Hen Lm A4 1 to A4 2 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN AA 1 to AA 6 A 1 Preamble AA 1 A 2 Addressing IP AA 2 A 3 Adressing plan AA 3 AA Use of static tables AA 3 A 5 Use of RIP routing demon AA 5 SECTION B Guide d installation et d utilisation BO 1 BA 6 Installation and User Guide N56717020101 Page A0 4 Reproduction and communication in any form prohibited without the written permission of E 1 1 1 INSTALLATION AND COMMISSIONING 1 INSTALLATION AND COMMISSIONING General The ADR 155C is an optical STM 1 add drop multiplexer used to build STM 1 point to point links STM 1 rings or mesh networks with conduct SNC or line MSP protection so performing the conveyance of links at 2 Mbit s Ethernet STM 1 The ADR 155C can be used as STM 1 terminal multiplexer with maximum capacity of 63 VC12 and capability of 1 1 protection STM 1 repeater capability of regenerating 2 VC4 STM1 multiplexer with insertion extraction with maximum capacity of 4 STM 1 and insertion extraction of 21 VC12 LAN interconnection point in exclusive function up to
134. uts 1 or 2 4 inputs 3 rt 4 4 ADR 155C 2 Local Local user inputs user inputs Local user outputs WEST Acivation of local user inputs 1 or 2 S1 state of local user ed folowing activation inputs 1 and 2 1 of local user outputs A or B equipment 3 alarms or local user 4 inputs 3 rt 4 ADR 155C 3 Local user inputs Figure 2 3 Remote loopback function registering alarms on central site NOTE Status of incoming loops Local user inputs 1 to 4 far incoming loops Far user inputs 1 to 2 and outgoing loops Local user outputs A and B may be displayed on HTTP navigator Installation and User Guide N56717020101 No reproduction or communication without the written consent of SAGEM SA Page A2 11 2 OPERATION 2 5 Alarms processing LEDs and pushbuttons The following tables give the meanings of the lit LEDs and the actions initiated by using the pushbuttons gt LEDs Monitored Designation Colour item Motherboard ON Green In service card Flashing Self test default Not powered equipment or not run software ALA M Red On Major alarm ALA m Yellow On Minor alarm management port Off No traffic or ADRLAN card Link Yellow On Correct Link __ Traffic cards STATUS See table below gt STATUS LEDs ADR IC 1 x ADR LAN and ADR 21E120 cards Green LED Red LED On Off __ Cardin service and configured On On Cardin service and in alarm
135. y and since the majority of RIP routing demon implementations do not support this feature The SUBNET field is defined by a mask which is written in the form 255 255 255 0 255 255 0 0 255 0 0 0 etc the number of zero bits from the left of the mask defines the length of the HOST field e g for the address 40 2 2 2 associated with mask 255 255 255 0 the NET field takes the value 40 the SUBNET field the value 2 2 and the HOST field the value 2 Installation and User Guide N56717020101 Page AA 2 No reproduction or communication without the written consent of SAGEM SA A 3 A 4 ANNEX A CONSTRUCTING AN IP NETWORK ADDRESSING PLAN Addressing plan A global IP network may be sub divided into N networks each with a NET number Within each network each physical link point to point or point multipoint has its own SUBNET number Each equipment connected to this link 2 for point to point link N for an Ethernet segment has its own HOST number Depending on the number of equipment pieces and links address classes A B or C are used with SUBNETS coded over one or two bytes To conclude an IP address and its SUBNET mask must be associated with each interface of a network node Use of static tables Concerning the use of static tables each network node must have its routing table completed in order for it to be able to route correctly the received packets All IP routes of a given equipment routin
136. yants 9 10 15 Break B Make B Common A Gnd R MON 4 N R MON 3 N R MON 2 N R MON 1 N Common B Break A Make A Sch ma de principe d une boucle s che au repos Voyant vert ON Allum carte en service d faut autotest quipement non aliment ou logiciel non d marr ALA Voyant rouge M allum Voyant jaune m allum alarme majeure alarme mineure Bouton poussoir ACK acquittement des alarmes ETH Contact 1 Contact 8 1 TX ETH TIP 5 NC 2 TX ETH RING 6 ETH RING 3 RX ETH TIP 7 NC 4 NC 8 NC Voyant jaune tat de la liaison liaison correcte Allum Voyant vert Allum Figure 1 3 Raccordement des acc s sur la carte m re Guide d Installation et d Utilisation N56717020101 Page B1 6 Reproduction et communication interdites sans autorisation crite de SAGEM SA tat du trafic r ception en cours NC R serv 1 INSTALLATION ET MISE EN SERVICE 1 3 2 Raccordements sur la carte m re 1 3 2 1 Acc s de t l signalisation de t l commande et d alarmes station LOOPS Interface LOOPS Acc s 4 entr es de t l signalisation Local user inputs pour contacts flottants polaris es au 48 V en interne actives l tat ferm et isolation galvanique courant de boucle compris entre 1 et 10 mA 2 sorties de boucle s che commun repos et travail Local user outputs utilis es
Download Pdf Manuals
Related Search
Related Contents
Télécharger la documentation PDF Release notes for Version 3.6 - Civil & Environmental Engineering x - Teacmexico.net MPM Kasia 116 Samsung FX2490HD Uživatelská přiručka POLIVERT AU JOJOBA Testo 340 portable flue gas analyzer user manual 日永浄化センター第2系統№2濃縮槽汚泥掻寄機設備工事 GE jes1290 User's Manual Copyright © All rights reserved.
Failed to retrieve file