RobinAir 15120A User's Manual

image

Contents

1. a ce J x O c co co E E 6 e 3 g l S io igo E i 2 A 5 if e ig On 3 Sa Oe ost ot lt i OF ess tai S25 SC Da Dc ioc gos Gr fF ors 952 lt aa LES cg2 oss ogo 582 Qc Do orp Sie Q o O are GTI or O45 cose 233 2352 lt 5 O Ese ESE OFS Te Oos Oos OOF O M22 Qa22 ICZM G D Fu tems Q O O Table of Contents eeeoee2e a2eeee0800080 Warnings CoolTech high performance vacuum pumps Pump components Before using your vacuum pump 15121A Wiring Instructions To use the gas ballast feature To shut down your pump after use To maintain your high vacuum pump Vacuum pump oil Oil change procedure Cleaning your pump Motor lubrication Troubleshooting guide Failure to start Oil leakage Failure to pull a good vacuum CoolTech specifications When you need help Replacement parts Warranty coverage For use on A C R systems using CFCs HCFCs and HFCs in conjunction with mineral oil ester oil alkylbenzene oil and PAG oil as lubricants Not for use with ammonia or lithium bromide systems Not for use with flammable refrigerants A Warnings eeee eee Wear goggles when working with refrigerants Contact with refrigerants may cause injury Incorrect use or connections may cause electrical shock hazards Study and follow the instructions carefully and take precautions to avoid electrical shock hazards All associated devices are
2. BROWN 3 BROWN 6 LINE LINE To use the gas ballast feature Moisture from the A C R system carried into the pump as a vapor tends to condense into a liquid and combine with the vacuum pump oil When moisture contaminates pump oil it reduces the pump s ability to reach its ultimate deep vacuum The gas ballast valve purges a small amount of atmospheric air through the exhaust chamber This extra volume of air mixes with the vapor from the refrigerant system to prevent condensation and to help exhaust moisture in the form of vapor from the pump To use the gas ballast start the pump and open the gas ballast valve The valve is located beside the handle opposite the inlet fitting When the system has reached approximately 1000 3000 microns close the gas ballast valve to allow the pump to pull down to its ultimate vacuum level The gas ballast valve may be opened or closed at any time during pump operation It is fully open at two turns counterclockwise Note Robinair recommends the use of a thermistor vacuum gauge to most accurately measure vacuum levels To shut down the pump To help prolong pump life and promote easy starting follow these procedures for shutdown 1 Close the manifold valve between the pump and the system 2 Turn the Iso Valve to the CLOSED position 3 Remove the hose from the pump inlet 4 Turn the pump power switch to OFF then OPEN the Iso Valve for a few seconds to
3. Fu Q O O 15121A Wiring Instructions The CoolTech vacuum pump features dual voltage ranges Before operating the pump read and follow these rewiring instructions if necessary to be certain your pump is wired for the appropriate voltage CAUTION To prevent personal injury unplug the unit before beginning service work Incorrect use or connections can cause electrical shock Only qualified personnel should perform service work The CoolTech vacuum pump is factory wired for a high voltage of 220 volts To wire the switch for a low voltage range of 110 volts to 127 volts follow these steps Disconnect unit from the AC power source Loosen the screws on the plate at the rear of the motor and carefully move the plate aside to clear the opening Disconnect the leads and reconnect for low voltage according to the following chart High voltage connections are also shown in case you want to rewire at some time Verify all connections are secure and there are no short circuits Verify the grounding connector is correctly connected Reinstall the plate on the rear of motor with the screws that were loosened in Step 2 Use acontinuity tester to check for short circuits before reconnecting the unit to the AC power source EMERSON MOTOR ELECTRICAL CONNECTION TABLE 115V 220V WIRE TERMINAL No WIRE TERMINAL No WHITE 4 WHITE 3 BLACK 2 BLACK 3 RED 5 RED 5
4. bottom of the sight glass The approximate oil capacity of the pump is 488 milliliters 161 2 ounces Verify the inlet ports are capped then turn ON the pump Allow it to run for one minute then check the oil level If the oil is below the sight glass OIL LEVEL line add oil slowly with the pump running until the oil reaches the OIL LEVEL line Replace the exhaust filter nand tight making sure the inlet is capped and the drain cap is tight If the oil is badly contaminated with the sludge that forms when water is allowed to collect in the oil you may need to remove the oil reservoir cover and wipe it out Repeat this procedure as required until the contamination is removed Replace the OIL DRAIN cap and refill the reservoir to the correct level with fresh pump oil see Step 4 Cleaning the pump Clean the pump with soap and water only CAUTION Do not use commercial cleaners that contain degreasing agents that can damage polycarbonates The pump handle and base are made of Lexan one of the toughest polycarbonate plastics available However it is sensitive to degreasing agents Lexan is a registered trademark of General Electric Motor lubrication After three years of normal service or one year of heavy duty service add electric motor oil or SAE 10 oil Troubleshooting guide Your CoolTech pump has been designed for dependable use and long life If something should go wrong however the following guid
5. properly grounded before energizing circuits The normal operating temperature will cause certain external portions of the pump to be hot to the touch Do not touch the pump housing or motor during operation CoolTech High Performance Vacuum Pumps eeeeeeeeoee8080 0 Congratulations on purchasing one of Robinair s top quality CoolTech vacuum pumps Your pump has been engineered specifically for air conditioning and refrigeration service and is built with Robinair s proven offset rotary vane for fast thorough evacuation You ll appreciate these key features Iso Valve Allows the pump to be shut off while still connected to the A C R system which is handy for checking rate of rise With the valve handle in the OPEN position the pump is open to the system being evacuated In the CLOSE position the pump is isolated from the system High vacuum rating The two stage offset rotary vane design provides powerful quiet high vacuum capability and ensures moisture removal while the high pumping capacity reduces evacuation time Lifetime filtration The intake filter prevents foreign matter from entering the pumping chamber and an exhaust filter separates oil vapor from the exhaust flow Gas ballast A precise amount of atmospheric air is introduced into the pump preventing condensation of moisture vapor and helping maintain the purity of the pump oil By using the gas ballast the pump
6. relieve any vacuum inside the pump Cap the inlet port to prevent any contamination or loose particles from entering the port To maintain your high vacuum pump For maximum performance Robinair recommends changing vacuum pump oil after each use Vacuum pump oil The condition and type of oil used in any high vacuum pump are extremely important in determining the ultimate attainable vacuum Robinair recommends the use of our Premium High Vacuum Pump Oil This oil has been specifically blended to maintain maximum viscosity at normal running temperatures and to improve cold weather starts Robinair Premium High Vacuum Pump Oil is available in convenient pint quart or gallon containers Order by part number 13201 Pint shipped 12 pints per case 13203 Quart shipped 12 quarts per case 13204 Gallon shipped 4 gallons per case Oil change procedure 1 Run the pump until warm 2 Remove the OIL DRAIN cap Drain contaminated oil into a suitable container and dispose according to local regulations Oil can be forced from the pump by opening the inlet and partially blocking the exhaust with a cloth while the pump is running Do not operate the pump for more than 20 seconds using this method When the flow of oil has stopped tilt the pump forward to drain residual oil Replace the OIL DRAIN cap Remove the exhaust filter and fill the reservoir with new vacuum pump oil until the oil just shows at the
7. 2010 SPX
8. 7V 220V Intake Fitting includes Nos 8 9 555124 Factory Micron Rating 15 microns take Caps 1 4 9a 1 2 SAE MFL 9 555133 Approximate Oil Capacity 488 ml 16 2 oz Handle Bolt includes o ring 11 15146 oe Handle Power Cord Switch Assy 12 15366 27 3 cm 10 15120A Motor and Handle Assy 13 15136 44 5 cm 171 2 ee Motor and Handle Assy 13 557127 44 S a and 1 2 SAE MFL Coupling i 28105 Min Starting Temp at 90 Voltage 0 C 32 F Iso Valve Assembly l 15966 Motor Size 0 37 kw 2 HP Capacitor Start Base and Foot Assembly 16 15369 Operating Temp aaa 74 C 165 F Pump Assembly Nos 1 9 14 19 15144 Seal Replacement Kit not shown 15367 Note Motors are internally protected automatic reset Operating temperatures are typical for normal operating conditions Because of ongoing product improvements we reserve the right to change design specifications or materials without notice D C Fu Q O O INST0189 Warranty coverage eeeoea2ene02e02e02020800080808080 Robinair CoolTech vacuum pumps are warranted against defects in material and workmanship for one year of normal use from the date of purchase See your distributor for warranty details Out of warranty A pump that is no longer covered by the one year warranty period and which fails to operate correctly should be returned to the distributor with a full written explanatio
9. discard the plastic plug from the top of the oil reservoir Before starting the pump fill with oil until the oil just shows in the bottom of the sight glass The approximate oil capacity of the pump is 488 milliliters 161 2 ounces 3 Thread in the exhaust filter nand tight and remove the cap from one of the inlet ports Turn the Iso Valve to OPEN Turn the motor switch ON When the pump runs smoothly turn the Iso Valve to CLOSED and replace the cap on the inlet port This may take from two to 30 seconds depending on ambient temperature After the pump runs for approximately one minute check the sight glass oil should be even with the sight glass OIL LEVEL line Add oil if necessary When the pump is running the oil level should be even with the OIL LEVEL line Underfilling will result in poor vacuum performance Overfilling can result in oil blowing from the exhaust The vacuum pump is now ready to evacuate air conditioning and refrigeration systems Follow normal service procedures and the A C R manufacturer s instructions for connections to the system CAUTION Before connecting the vacuum pump to an A C R system remove refrigerant from the system in an accepted manner Damage to the pump may occur if evacuation is started while the system is under high pressure Robinair recommends use of our Refrigerant Recovery and Recycling equipment Rev C May 10 2010 jenueyy Bunei do G D C
10. e will help you get the pump back into service as quickly as possible If disassembly of the pump is required please check your warranty The warranty may be voided by misuse or customer tampering which results in the pump being inoperable Failure to start Check the line voltage Robinair pumps are designed to start at 10 line voltage at 0 C 32 F At extremes however switching between the start and run windings may occur Oil leakage 1 Confirm the oil is not a residual accumulation from spillage etc The module cover gasket or shaft seal may need replacing Follow instructions in Seal Replacement Kit No 15367 If leakage exists in the area of the oil drain plug reseal the plug using a commercial pipe thread sealer Failure to pull a good vacuum 1 Confirm the Iso Valve is OPEN 2 Are the vacuum gauge and all connections in good conditon and leak free Confirm leakage by monitoring vacuum with a thermistor gauge while applying vacuum pump oil at connections or suspected leak points Vacuum will improve briefly while the oil is sealing the leak Is the pump oil clean A badly contaminated pump may require several oil flushes See Oil Change Procedure Note Use only high vacuum pump oil such as Robinair s Premium High Vacuum Pump Oil Other oils will prevent pull down to a deep vacuum Confirm the gas ballast knob is tightly closed Is the oil is at the correct level For maximum pump operat
11. ion the oil must be even with the OIL LEVEL line on the sight glass when the pump is running Do not overfill To check oil level start the pump with the inlet capped Add oil if necessary When you need help eeeeeaevene0e2e0020808080800 If these procedures do not correct the problem contact your nearest Robinair distributor The distributor may recommend an additional replacement part this manual contains a parts list or suggest you send your pump to the nearest authorized service center CoolTech specifications eeoeeevne0ee0e2e2ee0ee02e008080800880 Model 15120A Frequency Range Voltage Range Free Air Displacement Motor Speed Factory Micron Rating Approximate Oil Capacity 1725 rpm 15 microns 488 ml 161 2 oz 17 24 kg 38 Ibs 14 29 cm 5 s 27 3 cm 103 4 41 9 cm 161 2 1 4 3 8 and 1 2 SAE MFL Min Starting Temp at 90 Voltage 0 C 32 F Motor Size 1 2 HP Capacitor Start Operating Temp eseeceeeceeeeseeee 74 C 165 F enuen Bunei do CoolTech specifications Replacement parts e eeeeeeeeeneea0eae0e02eee00080 eeeeeaeeaeeaeedene02edeeee 80 Model 15121A Part Figure Part No Frequency Range 50 60 Hz Oil Drain Cap 6 1 40572 Free Air Displacement 283 l m 10 cfm Oil Drain Kit includes Nos 1 2 48116 236 lim 50Hz Module Cover Kit Nos 1 2 3 5 18 15139 Exhaust Filter 4 15147 Motor Speed 1450 1725rPM_ Gas Ballast Knob and Seal 7 15371 Voltage Range 110V 12
12. n of the problem Before returning an out of warranty pump review all maintenance procedures to avoid an unnecessary return Replacement parts are available for doing your own repair service vey Call our International Customer Service Line at 1 507 455 7223 or email our Technical Support at Robinairtechsupport servicesolutions spx com To help us serve you better be prepared to provide the model number serial number and date of purchase of your unit To validate your warranty complete the warranty card included with the unit and return it within ten days from the date of purchase If your unit needs replacement parts contact your local distributor If your unit needs repairs you may locate the nearest service center at www robinair com or by calling International Customer Service Due to ongoing product improvements we reserve the right to change design specifications and materials without notice The unit s weight scale provides a means for metering the amount of refrigerant needed for optimum air conditioning system performance as recommended by OEM manufacturers Do not use the unit to sell refrigerant by weight because this may not be permitted by certain local jurisdictions 655 EISENHOWER DRIVE OBINAR OWATONNA MN 55060 0995 USA TECHNICAL SERVICES 1 800 822 5561 AN SPX BRAND FAX 1 412 690 2001 CUSTOMER SERVICE 1 800 533 6127 FAX 1 800 283 8665 WEB SITE WWW ROBINAIR COM 122939 Rev C May 10
13. operates more efficiently and pump life is extended Sure grip handle The one piece molded handle makes it easy to carry the pump to and from job sites and the handle stays cool to the touch during operation Compact design The pump measures approximately 42 cm 161 2 in long while aluminum housing and offset rotary vanes keep the pump weight low making it easy to carry NOTICE Airborne Noise Emissions This equipment has been tested for airborne noise emission per the Council Directive for Machinery 89 392 EEC Section 1 7 4 Instructions Essential Health and Safety Requirements Sound levels do not exceed 80dB A actual value Pump components i Intake Fitting Gas Ballast Valve located beside handle Exhaust Filter Oil Fill Port Sight Glass Die Cast Aluminum Housing Oil Drain Molded Polycarbonate Base Iso Valve isolates the pump from the system High Torque Motor Power Switch Sure Grip Handle 2 3 4 5 6 7 8 9 Before using the vacuum pump Motors are designed for operating voltages plus or minus 10 of the normal rating see Specifications Single voltage motors are supplied fully connected and ready to operate 1 Verify the voltage and frequency at the outlet match specifications on the pump motor decal Place the ON OFF switch in the OFF position Verify the gas ballast valve is closed The pump is shipped without oil in the reservoir Remove and