Home

Robic SC-800 User's Manual

image

Contents

1. F E r n 2 40 3594 CHRONO RUN excmscet EL BACKLIGHT 0v avc w mm RCL SET 148 24289 3385 168 50 LAP MEMORY _SEL MODE mp SC BOO EL Bl BACKIGE SPEED TIMER 50 LAP MEMORY Thank you for buying the Robic SC 800EL Your purchase brings you a world class timer with a wide range of professional features and functions that are applicable to numerous timing activities for sport science amp technology To ensure maximum enjoyment from your timer please take a few minutes to carefully review this operating guide Once you are familiar with its operation you will be ready to enjoy its many fine features which include the following modes of operation normal time speed chronometer chronograph and countdown timer NORMAL COUNT sme NS mem SECS ew 1 1005 NORMAL TIME Hours Minutes Seconds Day Month Date Alarm Time Alarm Chime AM PM Indicators Normal 12 Hour or Military 24 Hour time Option Mode Switching EL Backlight SPEED SPEED CHRONOMETER 25 Hour Timing with 1 100 Second Resolution Set Distance 0 1 to 999 999 mi ki Speed from 1 0 to 999 999 mph kph Fifty 50 Lap On demand Memory Average Speed of Multiple Laps Lap Count 0 to 999 Time Out Mode Switching EL Backlight CHRONOGRAPH f Twenty five 25 Hour with 1 100 J 4 g 2 4 28 g Second Resolution 23g STEB Simultaneous Display of Lap Split g 4 p and Ac
2. STOP LOAD RESTART You may stop the countdown time at any time by pressing E To restart the countdown timer from the preset time press F and the countdown time will automatically return to the preset countdown time Row 2 and will instantly begin to countdown again to zero e g from 30 minutes and 00 seconds RESETTING THE CT You may reset the Countdown timer in two ways d coe 1 When the countdown timer Is stopped Proceed as explained above or 2 When the countdown timer is running Do not stop the timer Proceed as follows Enter set by pressing A until seconds begin to flash Set seconds by pressing C Once seconds are set press B and minutes will flash Press C to set minutes Once minutes are set press B and hours will flash Press C to set hours To end the setting sequence press A The new preset countdown time will load automatically once the origina countdown time reaches zero of 0 17 95 asiaan To ROW 2 CT g J H g g PRESET COUNTDOWN ROW 3 2 09 Jb P normat time 0 00 SB countoown S T CT 0 10 00 eum 2 3 g Jb P NORMAL TIME ALARM SOUND 1 A single beep tone will sound when the countdown time reaches zero 0 provided the countdown time has been set for fess than one 1 minute 2 A four 4 second beep tone will sound when the countdown time reaches zero 0 when the countdown timer has been set for one 1 minute or more MODE SWITCHI
3. TIME IS SPEED CHRONO k 44 12 SECONDS The above example shows the display if you use memory recall by pressing A Row 1 indicates the speed of Lap 061 and Row 8 the time of Lap 06 The speed of the last lap recorded L062 appears In Row 2 By continuing to Press A recall you can retrieve the previously recorded fifty 50 laps in descending order 60 59 58 etc When using memory recall the speed of the lap always appears in Row 1 and time always in Row 3 i TAE EROR 3 3 s When finished using memory recall the speed time data disappear automaticaily after flfteen 15 seconds or instantly if you press B Row 1 will return to all zeros and Row 3 to current tap running time At the end of event timing the memory recail will work the same as when the product is In use Memory cannot be used If you have reset the display to zeros AVERAGE SPEED of multiple Japs will be displayed any time when Pressing C The average AVG Indicator appears on the upper row of the display Average speed of completed laps appears in Row 1 and average time of completed laps in Row 3 Row 2 wiil display the speed of the last recorded lap AVERAGE SPEED INDICATOR wescoumeerso F HB 19 30 92 ERARE ues ust O62 19 85 JET sees AVERAGE TIME OF 62 LAPS COMPLETED 0005263 SPEED CHRONO The speed timer will display the average speed for 1 999 completed laps YOU CANNOT obtain an average speed re
4. com www robictimers com 3 While setting press and hold C for fast advance You may release to ine running time Taylor Spiit of the cuirent lap prior to fifteen 15 seconds by pressing B once END OF RACE At the end of the race press E The speed and time of the last lap will appear in the display lap and speed in row 2 and time in row 3 ACCUMULATED TIME Press F once and Row 8 will display the accumulated time of the race Press F again the timer will reset to zeros and you are ready to begin timing again IMPORTANT NOTICE When taking a tap reading and Error appears Row 2 you have exceeded the speed capability of the timer 999 989 mph kph This Occurs when you take a lap reading too soon either by accident or on Purpose le long track distance and fast lap time When this situation occurs your timer is functioning properly and is still recording data Wait until the lap is completed then Press F and the appropriate speed and time will appear on the display C SPECIAL FEATURES Your Speed timer is equipped with special features described below Review them carefully MEMORY Your timer has a fifty 60 lap memory through 999 laps The memory may be used during event timing or after the timer is stopped To use the memory recall press A anytime The recall indicator will appear ROW 1 G6 feo 39 Ag LAP 061 MPH ere G6 g H g 13 g g LAP 062 MPH eas 0 9 H y y ig LAP 061
5. the countdown timer proceed as follows Press and hold A until the seconds in row two 2 begin to flash To set seconds 00 59 press and hold A until the seconds digits in row 2 begin to flash Set seconds by pressing C until you have reached the desired number of seconds tists Bats Roe ATES etd daa elite To set minutes press B and minutes begin to flash then press C until the desired number of minutes appear 00 59 To set hours press B and hours begin to flash then press C until the desired number of hours appear 0 9 End the setting Sequence by pressing A once digits will stop flashing You may by pass setting seconds minutes or hours by pressing B You may stop the setting sequence at any time by pressing A HOW TO OPERATE THE CT Once you have set the countdown time you are ready to use the countdown timer Proceed as follows 1 You must load the preset time row 2 by pressing F The countdown time will appear in row 1 and will instantly begin to countdown as illustrated mau B 2 g 5 FIME COUNTING ROW 2 rT G 3 g IH g PRESET COUNTDOWN ROW 3 12 0 g J 6 P NORMAL TIME Once loaded the pre set countdown time will countdown to zero The CT will automatically return to 30 minutes and 00 seconds and will begin to countdown again to zero STOP RESTART To stop the CT during the countdown Process at any time press E To restart press E again
6. the module 3 If the timepiece is not marked water resistant avoid immersing or exposing it to water Steam or other forms of WHEN YOU REQUIRE SERVICE If your timepiece ever requires factory servicing you can send it directly to MBI CORP 115 HURLEY RD OXFORD CT 06478 We strongly recommend that when sending it through the mail you send the Product insured return receipt requested so that if a problem in shipping arises you can trace it through the originating post office You will be billed for all services performed deemed out of warranty and since we reserve the right to substitute with a Teplacement product of equal or greater value NEVER include a personal item such as a watchband with the repair request Robic Timers amp chrotiographs for champions at every level Please call at 203 264 2702 for a free catalog a a eee
7. NG You may enter and use other modes of operation while the CT Is being used by Pressing B You may enter the CT again by pressing B until you have reached the CT mode You cannot however use the speed timer if the chrono is running Conversely you cannot use the chrono if the speed timer is running MEMORY Your timer has the capability to recall the previous fifty 60 completed laps 60 49 48 etc at any time To use memory recall wh n the timer Is running press A and the recall indicator appears along with the individual lap and split times The memory recall data will disappear automaticaily after fifteen 15 seconds or instantly when pressing B To use memory recall after the timer is stopped and the display has not been reset to all zeros proceed as follows Press A continuously to retrieve memory data When finished the memory recall display will return to the last lap timed automatically after fifteen 15 seconds or instantly when you press B To reset the timer Press F until all zeros appear AVERAGE LAP TIME will be displayed when pressing C The average AVG Indicator appears The average lap time will be shown in the upper row of the display The average lap time data will disappear automatically after fifteen 15 seconds or instantly when pressing B Average lap data can be displayed after event timing and prior to resetting the display to zeros With the timer stopped press C to rea
8. ading after the timer has been stopped and display reset to zeros The average speed data will disappear automatically after fifteen 15 seconds or Instantly by pressing B ACCUMULATED TIME of the race wil be displayea atter the last lap of the event is recorded and the speed timer is stopped To read accumulated time proceed as follows Press E to stop the timer press F to read accumulated time and F again to reset the timer to zeros DO NOT press F to reset the timer to zeros after reading the accumulated time if you wish to access the memory or average speed Retrieve all the date prior to resetting the timer to all zeros TIME OUT Your timer has a time out feature If the event being timed Is stopped for any reason simply stop the timer by pressing E DO NOT reset the timer to all zeros When the event resumes press E again and your timer will begin recording data normally The previously recorded Information will be stored in memory for access by using memory recall Press A j gi ga IV CHRONOGRAPH HOW TO OPERATE From normal time press B twice and the chronograph indicator CHRONO appears f The stopped chronograph display wili appear as follows IF NOT press F to stop and E until the display is reset to ali Zeros ROW 1 G0900 0000 LAP TIME ROW 2 08 9 g og o Q sput time ROW 3 g t p Ug g p ACCUMULATED CHRONO MODE INDICATORS The working range of the
9. amages caused by or showing evidence of 1 Improper or unauthorized service 2 Misuse tampering abuse or mistreatment of the timepiece 3 Damage to the case or visible cracking of the lens 4 Moisture damage if the product is a non water resistant timepiece B If we find that the battery is the cause of the defect MBI Corp reserves the right to charge you 6 50 for a new replacement MBI Corp is not liable for incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you YOUR RIGHTS UNDER IMPLIED WARRANTIES AND STATE LAW MBI Corp limits the duration of any warranty implied by state law including the implied warranty of merchantability to one year from the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal Tights and you may also have other rights which vary from state to state CARING FOR YOUR TIMEPIECE Proper care of your timer will provide many years of enjoyment We recommend that 1 The battery be replaced at once when it becomes depleted Please ask your local retailer to replace the battery for you using a CR2625 Lithium or equivilent 2 The lens be replaced immediately if it becomes damaged as contamination from dust moisture and other foreign substances will damage
10. chronograph Is twenty five 25 hours with a resolution of 1 100 second The chronograph measures lap and split time simultaneously The accumulated running time is presented continuously Row 3 NOTE You cannot operate the chronograph if the speed timer is running To stop the speed timer enter the speed mode Stop timing by Pressing E once Press F until the timer is reset to al zeros Once the speed timer Is stopped you may enter and use the chronograph TIMING SINGLE LAP EVENTS Start timing by pressing E Stop timing by pressing E again Reset to zeros by Pressing F until zeros appear TIMING MULTIPLE LAP EVENTS Reset time to all zeros by pressing E to stop and F to reset to all zeros TO START Press E and the timer will begin to run Run indicator appears TO TAKE LAP SPLIT READING Press F TO STOP TIMING Press E then F to reset to all zeros Visit us on the web at www stopwatches com www robictimers com V COUNTDOWN TIMER HOW TO OPERATE Your watch has an auto repeat countdown timer CT with a working range from 1 second to 9 hrs 59 mins and 59 secs The CT will not work unless a countdown time has been entered To access the CT mode press B until the display appears as follows COUNTDOWN TIME INDICATOR CT ROW 1 i 0 9 G BG countoown mme ROW 2 CT B 8 g g g heset COUNTDOWN ROW 3 12 09 36 Byron SETTING THE CT if running stop the timer by pressing E To set
11. cumulated Times pal Lap Count to 999 gt Fifty 50 Lap On Demand Memory J On Demand Average Lap Time Mode Switching EL Backlight COUNT ee MINS nm SECS mmm COUNTDOWN TIMER Normal Time Display Countdown Auto Repeat Timer Working Range Ten 10 Hours Timer Reset During Countdown Operation Mode Switching EL Backlight jr ise 136 29 TT amp 1530F 120936 P iF EL BACKLIGHT OPERATION Pressing D at any time during any operation will activate the Electro Luminescent EL Backlight function for viewing at night and in low light or no light situations Once pressed the EL Backlight will illuminate the display for three 3 second with a light blue back lighting IMPORTANT Please use the EL backlight as required but note it will reduce the product s battery life il NORMAL TIME OPERATING INSTRUCTIONS The starting point for operating your watch is normal time If normal time is not dispiayed press B until it appears To set the alarm normal time and calendar press B mode select until the display appears as follows MONTH 1 12 A ALARM TIME mwtAL ANJO ATERN vav T H H g e Gate 1 31 A wen ALARM SYMBOL HOURS 2 9 g J b P A FOR AM 7 J P FOR PM CHIME SYMBOL MINUTES SECONDS To begin the setting process press and hold A until alarm hours begin to flash in the upper row of the display ALARM HOURS Pr
12. d the average lap time then F to reset the timer to zero NOTE When the chronograph Is stopped you cannot retrieve memory or average time data if the display has been reset to all zeros ALWAYS retrieve memory recall and or average time data prior to resetting the chronograph TIME OUT Your chronograph has a time out feature if the event being timed is stopped for any reason press E to stop timing restart by pressing E All previously recorded data will be stored In memory up to fifty 50 Japs LIMITED WARRANTY OUR BASIC POLICY Marshail Browning International Corporation MBI Corp warrants to the original owner this quartz digital liquid display timepiece excluding battery lens band or strap for the period of one year from the original purchase date This limited warranty is given by MBI Corp and not by the dealer from whom the timepiece was purchased THE WARRANTY PROCESS WHAT IS COVERED BY THE WARRANTY If the timepiece develops a manufacturing defect within the one year limited warranty period it will be either repaired or replaced at MBI Corp s option with a timepiece of equal value providing the original owner submits the following 1 Proof of purchase ie a validated store receipt showing date of purchase 2 A check or money order no cash please in the amount of 6 50 to cover the cost of shipping and handling WHAT IS NOT COVERED BY THE WARRANTY A MBI Corp will not repair defects or d
13. e set will appear and no digits will be flashing wie ROW 1 IH G So og T3 Cata J atn eae DISTANCE SET AT 2 1 2 MILES 2 500 rw 25 gt 90 00000 SPEED CHRONO stor Lj FLAGS SHOW SPEED TIMER STOPPED Co rsca cp ee c NOTES 4 Should you need to set any particular digit on the distance scale press A until mile or km appears flashing Then press B until the correct digit appears flashing Change the digit s by pressing C To end the setting procedure press A 2 The maximum setting distance Is 999 999 mites or kilometers 3 The speed timer will not work unless a distance has been entered C OPERATING THE SPEED CHRONOMETER After entering the track distance you are now ready to operate the speed chronometer For this section assume a track distance of 2 500 2 1 2 miles A ONE LAP EVENT START STOP ACCUMULATED TIME RESET START Press E to start the timer Run indicator appears STOP Press E again to stop the timer The Stop indicator appears and 0 00 44 12 seconds has elapsed The dispiay appears as LAP COUNT IS 001 MAE i MILE INDICATOR ew 09800 0608 rows EOD 120 39 89 seen ows BGO YY MESo ACCUMULATED TIME Press F and the accumulated time wili appear in row 3 of the display RESET ali zeros To return the timer to the start position all zeros press F again The display appears as follows m SET DISTANCE sg
14. ess C to advance alarm hours The A AM or P PM indicator adjusts automatically ALARM MINUTES Press B and alarm tens of minutes appear flashing Press C to advance NORMAL TIIME SECONDS Press B and normal time seconds appear flashing Press to reset to all zeros NORMAL TIME HOURS Press B and normal time hours appear flashing Press C to advance NORMAL TIME TENS OF MINUTES Press B and normal time tens of minutes appear flashing Press C to advance MONTH SETTING Press B and the month 1 12 digits appear flashing Press C to advance DATE SETTING Press B and date 1 31 appears flashing Press C to advance DAY SETTING Press B and the day appears flashing Press C to advance the day of the week MO Monday TU Tuesday WE Wednesday TH Thursday FA Friday SA Saturday and SU Sunday 12 24 HOUR OPTION The time may be set to operate normally hours 1 12 or on a 24 hour basis hours 1 24 To set the 12 or 24 hours Press B after setting the Day and either 12 or 24 will appear on the display To select 12 or 24 simply press C until the 12 or 24 time indicator appears After setting press A to exit the setting mode All digits except seconds will appear frozen NOTES 1 You may complete the setting process at any point by pressing A 2 If you wish to set any particular function alarm time calendar press and hold A for three 3 seconds The
15. n press B until that digit s appears flashing Press C to advance that function then press A to complete the setting process USING THE ALARM AND OR HOURLY CHIME The alarm can be armed set to go off to sound once per day The alarm symbol will appear when the alarm is armed The hourly chime In your watch can be armed set to go off to sound one 1 beep every hour on the hour The chime indicator fay will appear when the hourly chime is armed ARMED AND DISARMING THE ALARM AND HOURLY CHIME The alarm will automatically be armed set to go off after you set the alarm time The symbol will be visible above the P indicator on the lower row of the display or With your watch in normai time no digits appear flashing to sound hourly 1 Press C and the chime symbol appears armed and the alarm symbol 2 Press C again and the chime symbol disappears appears armed to sound at the time set i e 7 30 A 3 Press C again and the chime symbol and alarm symbol are visible and armed to sound chime hourly alarm at its set time 4 Press C again and both the chime and alarm symbols disappear Both are disarmed Ill SPEED CHRONOMETER HOW TO OPERATE To enter the speed mode from normai time press B once If the speed timer is running stop timing by pressing E once Reset the display to all zeros by pressing F once or twice The display appears as follows
16. rr SET DISTANCE IN MILES ROW 1 ROW 2 TRACK DISTANCE IS SET At 1 4 MILE 0 250 ROW 3 FLAGS SHOW SPEED MODE 1S STOPPED _ e T sigh BSS 1 How to Determine and Enter the Track Distance The first step Is to enter the track distance correctly The speed timer will not work unless a distance is entered Distance is entered as the decimal equivalent of a mite or kilometer from 000 001 to 999 999 For example enter 2 1 4 miles kitometers as 002 250 1 3 as 000 333 1 8 as 000 125 etc You may convert feet to the decimal equivalent of a mile t e 187 feet is entered as 000 035 187 divided by 5280 0 035 Convert meters to kilometers as follows 230 meters is entered as 000 230 230 divided by 1000 0 230 2 Enter Track Distance To enter the track distance when the timer is stopped and reset to zeros proceed as follows A Press and hoid A unti mile or km appears flashing in the upper right hand corner of the dispiay Press C until the desired unit of measurement Mile or KM appears B Press B and the first digit of the distance scale Row 2 000 000 appears flashing Advance the digit 0 9 by pressing C until the desired digit appears Once set move to the second digit by pressing B once Change the second digit by pressing C Continue to set each digit on the distance scale until you have entered the correct distance Press A to end the distance setting process The distanc
17. ug IN MILES ew 90000 0800 row GGG D e 504 SRA nnenannn rows 10 00 00 88 FLAGS SHOW SPEED MODE IS STOPPED B MULTI LAP EVENT TIMING When timing multi lap events the operating sequence is START LAP STOP ACCUMULATED TIME RESET START Press E to start Run indicator appears and the time counter Row 3 is counting LAP To take a lap reading press F the instance the lap is completed The lap number and speed appear in Row 2 the time in Row 3 After 15 seconds the time will revert to current lap running time You may select current lap running time instantly by pressing B Continue to press F for each lap reading oo ILLUSTRATION A wit gt MILE INDICATOR row 000000000 ROW 2 g H i g H 39 B G soo MPH rows OOD YY 12 ait stos ILLUSTRATION B b g d g g g 0 0 g g ROW 2 og i co 19 H 9 ereen Lar coon ROW 3 06 9 fe Ye Lar 002 RUNNING Illustration a above indicates the dispiay after you have taken a lap reading It notes the speed and time of LAP 001 The time will revert to current lap running time after 45 seconds or instantly when you press B lilustration B above shows the lap speed of Lap 001 Row 2 and the running time of Lap 002 Row 3 Running time disappears automatically after fifteen 15 seconds The speed and time of Lap 002 will appear only after you press F the instant Lap 002 is completed ena Visit us on the web at www stopwatches

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi  User Manual  Istruzioni d`uso - VEGABAR 65 - Profibus PA  une liste de critères objectifs  Découverte et mise en œuvre  

Copyright © All rights reserved.
Failed to retrieve file