Robertshaw RS4110 User's Manual
Contents
1. Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides The battery compartment will pull down from the 9000 j thermostat body and will detach Install two AA batteries following the polarity as shown inside the compartment Place the compartment back into the thermostat When the batteries are low the thermostat will enter a low battery mode Low battery mode has two levels e LEVEL 1 The low battery icon will be displayed The thermostat will continue to operate Replace h the batteries as soon as possible LEVEL 2 The low battery icon will flash If 24V AC y I Y is present the thermostat will continue to operate if the batteries are discharged or removed If 24V AC is not present the thermostat runs on batteries only and THE SYSTEM WILL NOT OPERATE Replace batteries immediately The clock will continue to run for 10 minutes when the batteries are removed Replace batteries if leaving thermostat unattended for more than 30 days Display Map The thermostat display will show information that is being used during operation or programming This illustration shows all of the display s possibilities with an explanation 1 2 MoRN MON TUE WED THU FRYSAT SUN DAY 7 SOA SCHEDULEJFOR EVE CHECK SET AT NTE CC ICC OW Vi CI OL
2. n la demanda de calefacci n refrigeraci n Energy Efficient Recovery Con esta funci n el termostato prev el evento siguiente y trata de alcanzar el valor deseado pr ximo en el momento exacto del evento Si el sistema tiene dos etapas el termostato usar nicamente la primera etapa durante este per odo Este sistema es m s eficiente que esperar hasta que se presente el evento siguiente y luego poner en funcionamiento la primera y segunda etapas Visor con iluminaci n trasera El termostato est equipado con una luz posterior para ver el visor con m s facilidad Pulse la tecla 4 para activar la luz La luz se apaga despu s de 10 segundos sin actividad Si el termostato est conectado para que la luz posterior est prendida siempre la luz nocturna se puede prender y apagar desde el men Modo Sobrecontrol Cuando se programa el termostato se guardan los valores y el programa El termostato cumplir el programa salvo que se ingrese el Modo Sobrecontrol El Modo Sobrecontrol tiene tres variantes Modo Sobrecontrol permanente Pulse el START STOP SCHEDULE PROGRAMA INICIO DETENCI N hasta que la palabra SCHEDULE desaparezca del visor Aparece el valor deseado de temperatura El termostato llamar el modo calefacci n o refrigeraci n para mantener el valor deseado de temperatura Pulse las teclas 4 o W para modificar el valor deseado Se debe seleccionar el modo calefacci n o refrigeraci n Modo Sobrecontrol de
3. LUG ars AUT VAC Es sy 195 Vemma Veen it BO 12 8 1 Event names used for editing schedule 2 Day is displayed on IDLE screen Also used to display day ranges when editing the schedule e g SAT SUN for weekend Used with clock to display hold duration e g FOR 2h Displayed when running a schedule Used with setpoint Used along with clock for service reminders e g CHECK HP Used for time current setpoint and some configuration data e g filter hours 8 HVAC mode and status Icons blink when active A is for Auto 2 is for second stage E is for emergency is for heating and is for cooling 9 Indicates when security is active 10 Low battery indicator 11 Displayed when in vacation hold 12 Used for ambient temperature and configuration data e g first stage differential F or C etc 13 Fan status rotates when active 14 Fan use selected by pressing FAN button NO OV mw 3 Set Time and Day To adjust the time and day settings press the SET TIME button The hour will flash If a button is not pushed within 10 seconds the thermostat returns to operation To change the settings 1 Use the and W buttons to change the flashing number 2 Press the SET TIME button to move through hour minutes and day of week 3 Make changes as needed They will be saved automatically NOTE THE THERMOSTAT WILL NOT CORRECT FOR DAYLIGHT SAVING TIME The thermostat will
4. ante cambios muy peque os de temperatura Si est programado en la escala Fahrenheit el rango de oscilaci n es de 0 5 a 3 0 grados Si est programado en la escala Celsius el rango de oscilaci n es de 0 5 a 1 5 grados El diferencial est fijado de f brica en 1 0 F 0 5 C Esto significa que el sistema se pondr en funcionamiento toda vez que la temperatura ambiente difiera en m s de 1 F 0 5 C de la temperatura deseada Si el sistema se pone en funcionamiento muy seguido aumente el valor del diferencial Tenga en cuenta que con un diferencial m s elevado la temperatura ambiente se modificar m s antes de que el sisterna se ponga en funcionamiento HH po A DIF2 DIFERENCIAL DE SEGUNDA ETAPA funciona con la primera etapa para controlar un segundo sistema de calefacci n refrigeraci n Este n mero se incorporar al diferencial de primera etapa Ver Sistemas de dos etapas Si la primera etapa se pone en funcionamiento muy seguido disminuya los valores fijados De esta forma se pondr en funcionamiento la segunda etapa para ayudar a la primera etapa Si ambas etapas se ponen en funcionamiento muy a menudo aumente este valor para demorar la segunda etapa WV Fe WJ DLY2 DEMORA DE LA SEGUNDA ETAPA este temporizador empieza a funcionar cuando se pone en funcionamiento la primera etapa Se reprograma cuando la primera etapa deja de funcionar Si se termina el plazo del temporizador se pone en funciona
5. g CHECK HP Used for time current setpoint and some configuration data e g filter hours HVAC mode and status Icons blink when active Ais for Auto 2 is for second stage E is for emergency is for heating and is for cooling 9 Indicates when security is active 10 Low battery indicator 11 Displayed when in vacation hold 12 Used for ambient temperature and configuration data e g first stage differential F or C etc 13 Fan status rotates when active 14 Fan use selected by pressing FAN button 3 NA S p Para ajustar la hora y el d a Para ajustar la hora y el d a pulse la tecla SET TIME fijar la hora La hora titilar en forma intermitente Si no se pulsa ninguna tecla en 10 segundos el termostato vuelve a ponerse en funcionamiento Para cambiar los ajustes 1 Use las teclas 42 y W para modificar los n meros que titilan 2 Pulse la tecla SET TIME fijar la hora para avanzar las horas minutos y d as de la semana 3 Realice los cambios necesarios Se guardar n autom ticamente NOTA EL TERMOSTATO NO SE AJUSTAR AUTOMATICAMENTE DURANTE EL PERIODO DE AHORRO DE LUZ DE D A Ahora el termostato funcionar correctamente con los ajustes por defecto Ajustes por defecto El termostato est preprogramado con una configuraci n recomendada por EnergyStar La configuraci n est dise ada para reducir los costos de energ a de todo el a o El ajuste de la configura
6. no funciona correcta mente Cambie la opci n del ventilador a gas o electricidad para adecuarlo al sistema ver secci n Para fijar el ventilador en ON AUTO o CIRC El termostato no muestra la temperatu ra ambiente correcta Verifique el ajuste de la escalaF C Fahrenheit Celsius ver secci n Para cambiar la programaci n El visor muestra HI o LO y la temper atura ambiente es normal Llame a un t cnico especializado para cambiar o reparar Si no puede resolver alg n problema con su termostato p ngase en contacto con www invensyscontrols com o Soporte T cnico 800 445 8299 Garantia Limitada de 5 a os Invensys Control garantiza al instalador contratista original o al usuario original que cada termostato Robertshaw nuevo no tendr defectos en componentes ni en construcci n con el uso y mantenimiento normal durante un per odo de cinco 5 a os desde la fecha de la compra Esta garant a y nuestra responsabilidad no se aplican a las pilas ni a los productos que hayan sido da ados por maltrato negligencia falta de cuidado en el manejo modificaciones instalaci n incorrecta o uso que no se condiga con las recomendaciones e instrucciones de Invensys Controls Invesys Controls acepta reparar o cambiar seg n su criterio todo termostato en garant a siempre y cuando sea devuelto dentro del per odo de garant a con franqueo prepago con prueba de fecha de compra El costo del retiro o rei
7. por vacaciones El visor mostrar la temperatura ambiente y el valor deseado aparecer intermitentemente con la cantidad de horas de funcionamiento que quedan en modo sobrecontrol Pulse las teclas 4 y W para modificar el valor deseado Este ser el nuevo valor deseado para futuros usos en el modo sobrecontrol por vacaciones Cancele el modo sobrecontrol pulsando la tecla START STOP SCHEDULE PROGRAMA INICIO DETENCI N ari TE Origen del valor deseado Cuando el termostato est usando un programa los valores deseados de temperatura se originan a partir de los valores fijados para el programa WORN MON a SCHEDULE 1 g q L 60 Cuando uno de los modos de sobrecontrol se activa el valor deseado se origina a partir de la temperatura del modo sobrecontrol Use el visor para determinar el origen del valor deseado de temperatura actual Modo sobrecontrol permanente No aparecen el dia la hora y el programa Ve C ry Te Modo sobrecontrol por vacaciones Aparece Vac y For El reloj muestra los d as en modo sobrecontrol El visor alterna los d as de modo sobrecontrol con el valor deseado SETAT A ro Ve iz I S g dd Modo sobrecontrol temporario Aparece el d a y For El reloj muestra las horas en modo sobrecontrol El visor alterna las horas de modo sobrecontrol con el valor deseado MON yy i We MTC E IL IC Sm Auro rye Cierre autom tico El
8. puede finar en 0 apagado o en un valor de hasta 9900 horas Cuando finaliza el tiempo aparece en el visor CHECK FLTR Pulse cualquier tecla para volver a fijar y volver CYCL el temporizador de ciclo le permite al compresor descansar entre ciclos Se puede fijar de 0 a 5 minutos en incrementos de 1 minuto ADVERTENCIA Un ciclo corto inconveniente puede da ar el equipo Este valor nicamente debe ser modificado por una persona especial izada en sistemas HVAC CAL compensaci n de calibraci n Cambia la temperatura exhibida de la temperatura real entre 3 y 3 grados en incrementos de un grado Aumentar la compensaci n en 2 significa que el termostato mostrar una temperatura que es 2 grados superior a la temperatura ambiente real Bloqueo de seguridad para proteger los valores fijados Las teclas que aparecen en la parte delantera del termostato pueden bloquearse con una contrase a Para crear una contrase a 1 Pulse las teclas Aa y simult neamente durante 5 segundos Se le pedir que ingrese una contrase a de cuatro d gitos 2 Cada d gito se fija pulsando las teclas 4M y W Pulse la tecla para pasar al d gito siguiente Pulse la tecla para volver atras 3 La contrasefia queda guardada despu s de 10 segundos 0 al pulsar s y 6 simult neamente Todas las teclas de la parte anterior ahora estan bloqueadas y permanecer n bloqueadas hasta que se ingresa la contrase a Si pulsa 10 cualquier tecla ap
9. termostato no mostrar valores de temperatura superiores a 99 F 37 C o inferiores a 32 F 0 C Si eso sucede el visor mostrar HI o LO El termostato sigue controlando la calefacci n y la refrigeraci n y mostrar la temperatura cuando los valores se encuentren entre 32 F 0 C y 99 F 37 C Para fijar el ventilador en ON AUTO o CIRC El ventilador tiene tres modos On Auto y Circ Pulse la tecla s para cambiar de modo del ventilador ON el ventilador funciona constantemente La temperatura ambiente los valores deseados y el estado del equipo de calefacci n y refrigeraci n no tienen efecto sobre el ventilador AUTO el ventilador se pone en marcha cuando se requiere el servicio de refrigeraci n o calefacci n CIRC El ventilador funciona en ciclos de 10 minutos de actividad y 20 minutos de descanso Cuando se requiere el servicio de calefacci n o refrigeraci n el ciclo se interrumpe y el ventilador responde al llamado El ciclo se circulaci n del ventilador se reinicia cuando se ha dado respuesta al llamado de calefacci n o refrigeraci n Resoluci n de problemas Problema Soluci n El termostato no pone en funcionamiento el sistema Verifique el cableado ver secci n Diagramas de cableado en el Manual de Instalaci n El sistema se pone en funcionamiento muy pronto Aumente el diferencial de temperatura ver secci n Para cambiar la progra maci n El ventilador
10. to start editing the schedule Push repeatedly to move through the selections VACATION Used to set a temporary setpoint for a number of days SET TIME Sequences through the hour minute and day LIGHT BAR Turns on the display back light for 10 seconds FAN Turns fan to AUTOMATIC CIRCULATE or ON UP ARROW Used during programming to increase the flashing item DOWN ARROW Used during programming to decrease the flashing item HEAT COOL Sequences through OFF HEATING COOLING and AUTO If you are using an RS5220 and it is configured as HP emergency heat is also displayed To Make Changes in the Schedule This thermostat can operate using a single setpoint by overriding the schedules If you will be using this thermostat for single setpoint operation skip to Overriding the Schedule Use the following table to document your schedule settings before editing the schedule on the thermostat Time Cool Heat Morning Day Evening Nite Press START STOP SCHEDULE at any time to exit and save your settings Push EDIT SCHEDULE The start time of the setpoint will be flashing If a button is not pushed within 30 seconds the thermostat returns to operation Use the s or W to change the hour of the start time if desired Push EDIT SCHEDULE to move to minutes Use the s or YW to change the minutes of the start time if desired Push EDIT SCHEDULE to move to the heat or cool temperature setting
11. Cancel the override by pressing START STOP SCHEDULE o AM a Jd O mM i Origin of Setpoint When the thermostat is using a schedule the temperature setpoint originates from the schedule settings MORN MON SCHEDULE ai pe ca TIC When one of the schedule overrides is active the setpoint originates from the override temperature Use the display to determine the origin of the current temperature setpoint Permanent Override The day time and schedule are not displayed yy o ie F e E s Vacation Override Vac and For are displayed The clock shows days of override The display alternates days of override with setpoint aera yy w FOR 5 7 Auro 4 aur vac aa ES L Temporary Override The day and For are displayed The clock shows hours of override The display alternates hours of override with setpoint f MON w a w FOR 1 SETAT 1 C ic o D auto auto 4 EJ AS 1 am j Automatic Shut Down The thermostat will not display if the temperature is higher than 99 F 37 C or lower than 32 F 0 C If this happens the display will show HI or LO The thermostat continues to control heating and cooling and will display the room temperature when it is between 32 F 0 C and 99 F 37 C Setting the Fan to ON AUTO or CIRC The fan has 3 settings On Auto and Circ Press the 5 button to switch among
12. INFERIOR AL VALOR DESEADO DE REFRIGERACI N Pulse EDIT SCHEDULE EDITAR PROGRAMA y repita el proceso para los tres valores restantes de los d as de semana Todos los d as de semana usar n esta programaci n Despu s de completar la programaci n de los d as de semana el visor mostrar la programaci n para los d as de fin de semana Siga los mismos pasos para programar los cuatro valores de los d as de fin de semana Cuando termine el termostato empezar a funcionar despu s de 30 segundos Para cambiar los valores ingresados Cuando se pulsas las teclas 4 and W al mismo tiempo el visor mostrar los valores programados en ese momento Para cambiar los valores programados Cuando aparezca el valor titilando en el visor pulse las flechas AM y W para cambiar los n meros en la pantalla Para salir del modo cambio y guardar Pulse el START STOP SCHEDULE PROGRAMA INICIO DETENCI N El termostato se pondr nuevamente en funcionamiento SCAL escala en F Fahrenheit o C Celsius CLOC ajuste del reloj para que muestre la hora en formato de 12 6 24 horas 7 light ra r cz MEN mo luz del visor siempre prendida Y o apagada n Tambi n llamada funci n de iluminaci n nocturna Si el termostato ha sido conectado para habilitar esta funci n aparecer la indicaci n correspondiente y se podr modificar el valor DIFF el diferencial evita que el termostato se ponga en funcionamiento
13. OTES
14. RS4110 RS4220 RS5110 RS5220 RS6110 RS6220 352 00056 001 USERS MANUAL Thank you for purchasing a Robertshaw RS5000 Series programmable thermostat This user s manual will guide you through the setup of the RS5110 single stage and the RS5220 two stage thermostats The thermostat should already be mounted and correctly wired The default settings will enable the thermostat to operate efficiently Before making any changes to the schedule read the section on Default Settings Features e Pop Up Wizard e Automatic changeover e Circulating fan e Worry Free memory retention e Easy change battery e Large back lit display e Filter change reminder e Low battery indicator e Fahrenheit and Celsius displays e EnergyStar compliant e Dual power e Adjustable 15 stage temperature differential 0 5 F degrees to 3 0 F degrees 0 5 C degrees to 1 5 C degrees e Accuracy within 1 F degree e Universal staging on multi stage units e Automatic heating shutdown if temperature exceeds 99 F 37 C e Keypad security lockout e 4 events per day for heating and cooling e 5 2 day scheduling e User settable Hi and Lo temperature limits e Vacation setpoint override Application The Robertshaw 5000 family of thermostats is designed to control gas electric oil heat pump and millivolt heating and electric cooling systems The RS5110 is a single stage thermostat while the RS5220 is a two stage thermostat The RS5000 thermostats use 5 2 progra
15. Use the amp or YW to change the temperature setpoint Pressing will switch between cooling and heating Use and W to change the setpoint OR Push EDIT SCHEDULE to move from heat to cool or cool to heat temperature setting Use the amp or W to change the temperature setpoint NOTE THE HEATING AND COOLING SETPOINTS CANNOT BE ENTERED AS CROSSED THAT IS THE COOLING SETPOINT CANNOT BE LOWER THAN THE HEATING SETPOINT Push EDIT SCHEDULE and repeat this process for the remaining three weekday settings All of the week days will use this schedule After the weekday schedule is complete the display will show the weekend schedule Continue the same steps to program the four weekend settings When you are finished the thermostat will be in operation after 30 seconds To Make Changes to the Settings When 42 and W are pressed at the same time the thermostat will display the current settings in order To change any setting When the setting is visible and flashing press the A or W arrows to adjust the number on the screen To exit the changes and save press START STOP SCHEDULE The thermostat will return to operation SCAL Scale in F Fahrenheit or C Celsius CLOC Clock setting in 12 or 24 hour readings m Ar ELDE non light Display backlight always on Y or off n Also called the nightlight feature If the thermostat has been wired to enable this feature it will be displayed and the se
16. al default value is 2 0 F degrees or 1 0 C degree and time delay default value 20 minutes control the 2nd stage cycle The 2nd stage turns on when e The room temperature changes from the setpoint by the sum of the 1st and 2nd stage differential settings e The first stage has been on for the specified delay time but the heating cooling demand has not yet been met Energy Efficient Recovery With Energy Efficient Recovery the thermostat looks ahead to the next event and attempts to reach the next setpoint at the exact time of the event If you have two stages the thermostat will use only the first stage during this period This is more efficient than waiting until the next event and then turning on both the first and second stages Backlit Display This thermostat is equipped with a backlight to make viewing the display easy Press the button to activate the backlight The backlight will turn off after 10 seconds of inactivity If the thermostat is wired to have the backlight stay on all the time the night light can be turned on off in the settings menu Overriding the Schedule When the thermostat has been programmed the settings and the schedule are saved The thermostat will follow the schedule unless an override is entered Three methods of override are available Permanent Override Press START STOP SCHEDULE until the word SCHEDULE is not shown on the display The setpoint temperature is displayed The thermostat will call fo
17. arecer el cono a Para destrabar las teclas 1 Pulse y mantenga oprimidas las teclas s y 5 segundos hasta que el sistema le solicite la contrase a 2 Ingrese los d gitos de la contrase a pulsando las teclas Muy V Pulse la tecla OE para pasar al d gito siguiente z Pulse la tecla s3 para volver atr s Si ingresa la contrase a equivocada en el visor titilar la palabra NO durante 5 segundos y luego volver a la pantalla normal 3 Pulse las teclas 4h y cuando aparezca la contrase a correcta Las teclas se destrabar n Una vez que haya desactivado la protecci n de seguridad deber volver a crear otra contrase a para proteger los ajustes ingresados Sistemas de dos etapas La segunda etapa es un sistema secundario o adicional que proporcionar calefacci n o refrigeraci n extra Cuando est en funcionamiento la segunda etapa el visor mostrar el n mero 2 a trav s de los conos de refrigeraci n y calefacci n Un diferencial de temperatura programable el valor por defecto es 2 0 F 1 0 C y retardo valor por defecto 20 minutos controla el ciclo de segunda etapa La segunda etapa vuelve a ponerse en funcionamiento cuando e La temperatura ambiente se aleja del valor deseado en un incremento que es igual a la suma de los valores diferenciales de la primera y la segunda etapa e La primera etapa ha estado funcionando durante el tiempo de retardo especificado pero no se ha alcanzado a
18. ary This can be from heat to cool or cool to heat de HI High Heat Limit This is the highest allowed heating setpoint The user will not be allowed to set a schedule setpoint or override temperature higher than this value cr gt LO Low Cool Limit This is the lowest allowed cooling setpoint The user will not be allowed to set a schedule setpoint or override temperature lower than this value o A R A VAC HEAT Vacation Heat Setpoint This is the temperature setpoint for the heating system when a vacation override has been made active ow TJ oc ee VAC COOL Vacation Cool Setpoint This is the temperature setpoint for the cooling system when a vacation override has been made active CHECK Timer to remind the home owner to maintain the filter Default setting is off The timer runs when the system is on and can be set at 0 OFF or up to 9900 hours When the timer expires CHECK FLTR is displayed Press any button to reset and return to the normal display CYCL Cycle Timer allows a compressor to rest between cycles Can be set from 0 to 5 minutes in 1 minute increments AWARNING A wrong short cycle setting can damage your equipment This should only be changed by a trained HVAC professional CAL Calibration offset Changes the displayed temperature from the actual temperature by 3 to 3 degrees in one degree increments Increasing the offset by 2 will cause the therm
19. as teclas 44 o W Sino se pulsa ninguna tecla en 10 segundos el termostato vuelve a ponerse en funcionamiento Puede acceder a las siguientes teclas desde el panel delantero START STOP SCHEDULE PROGRAMA INICIO DETENCI N cambia entre poner en funcionamiento un programa y el modo manual sobrecontrol permanente Cancela el modo sobrecontrol temporario o por vacaciones EDIT SCHEDULE EDITAR PROGRAMA Use este bot n para empezar a editar un programa Presione repetidamente para ir pasando las opciones VACATION VACACIONES se usa para fijar un valor temporariamente por una cantidad de d as SET TIME FIJAR LA HORA secuencia la hora minutos y el d a LIGHT BAR BARRA DE ILUMINACI N ilumina el visor durante 10 segundos FAN VENTILADOR pone el ventilador en funci n AUTOM TICA CIRCULAR o PRENDIDO FLECHA ARRIBA se usa para aumentar el valor del elemento que titila durante la programaci n FLECHA ABAJO se usa para disminuir el valor del elemento que titila durante la programaci n HEAT COOL CALEFACCION REFRIGERACION secuencia entre OFF CALEFACCI N REFRIGERACI N y AUTO Si usted tiene un modelo RS5220 y est configurado como HP tambi n aparece calefacci n de emergencia Para cambiar la programaci n Este termostato puede funcionar con un nico valor deseado activando el modo sobrecontrol de programaciones Si usted usa el termostato con un solo valor deseado vaya directamente a la secci n Modo Sobre
20. ci n por defecto es Hora Refrigeraci n Calefacci n F Ma ana 6 00 am 18 70 Dia 8 00 am 85 62 Anochecer 6 00 pm 78 70 Noche 10 00 pm 82 62 Ajustes programables del usuario Por defecto Durante cualquier cambio en la programaci n el visor vuelve al modo operaci n si no se presiona ninguna tecla durante 10 segundos La escala de temperaturas est en grados Fahrenheit La luz de noche est apagada El diferencial de primera etapa es 1 El diferencial de segunda etapa RS5220 es 2 F El margen de oscilaci n para conmutaci n autom tica es 3 F El recordatorio de duraci n del filtro est apagado La compensaci n de temperaturas es cero grado El l mite superior de calefacci n HI es 90 F 32 C El limite inferior de refrigeraci n es 45 F 7 C Los valores de temperatura para per odo de vacaciones se fijan en calefacci n 62 F refrigeraci n 85 F El modo de operaci n ser uno de los siguientes El ajuste del ventilador es Auto El teclado no tiene una contrase a de protecci n Consulte en la secci n del Asistente Desplegable Pop Up Wizard del Manual de Instalaci n la lista completa de ajustes por defecto de f brica y del contratista Calefacci n de emergencia Su sistema puede incluir la funci n calefacci n de emergencia Los termostatos RS5220 tienen calefacci n de emergencia para los sistemas de bomba de calor con etapas m ltiples Para saber si su sistema tiene esta funci n c
21. control Use el siguiente cuadro para registrar los valores programados antes de editar el programa en el termostato Hora Refrigeraci n Calefacci n Ma ana D a Anochecer Noche Pulse el START STOP SCHEDULE PROGRAMA INICIO DETENCI N en cualquier momento para salir y guardar los valores ingresados Pulse EDIT SCHEDULE EDITAR PROGRAMA Estar titilando el horario de inicio y el valor deseado Si no se pulsa ninguna tecla en 30 segundos el termostato vuelve a ponerse en funcionamiento Use lasteclas 4 y W para modificar la hora de la hora de inicio si lo desea Pulse EDIT SCHEDULE EDITAR PROGRAMA para avanzar los minutos Use las teclas 4 y W para modificar los minutos de la hora de inicio si lo desea Pulse EDIT SCHEDULE EDITAR PROGRAMA para pasar a fijar la temperatura de calefacci n o refrigeraci n Use las teclas s o W para cambiar el valor deseado de la temperatura Al pulsar pasar de calefacci n a refrigeraci n o viceversa Use las teclas 4 y W para cambiar los valores deseados gt Pulse EDIT SCHEDULE EDITAR PROGRAMA para cambiar los valores de temperatura de calefacci n a refrigeraci n y de refrigeraci n a calefacci n Use las teclas 4 o W para cambiar el valor deseado de la temperatura NOTA NO PUEDEN INGRESARSE VALORES DESEADOS DE CALEFACCI N Y REFRIGERACI N QUE SE ENTRECRUCEN ES DECIR EL VALOR DESEADO DE REFRIGERACI N NO PUEDE SER
22. ica perjudicar el termostato y causar la nulidad de la garant a No conecte a tierra ninguno de los terminales de esta unidad Este termostato est configurado con protecci n autom tica del compresor para prevenir da os por ciclos de corta duraci n o cortes prolongados de suministro de energ a La protecci n de ciclos de corta duraci n proporciona un retardo en los ciclos del compresor en las bombas de calor Las instrucciones detalladas de montaje y conexi n se incluyen en el Manual de Instalaci n Consulte la secci n Asistente Desplegable Pop Up Wizard del Manual de Instalaci n la lista completa de valores por defecto de f brica y programados por el contratista Para llevar energ a al termostato Consulte el diagrama de cableado en el Manual de Instalaci n Estos termostatos funcionan con dos pilas AA o con corriente de 24V CA Los termostatos que funcionan con pilas y reciben energ a de 24V CA seguir n funcionando si hay un corte de la corriente 24V CA Para instalar o cambiar las pilas Para retirar el compartimiento de las pilas apriete suavemente los bordes estriados de ambos lados El compartimiento de pilas de desprender del cuerpo 2006 del termostato Coloque dos pilas AA seg n la indicaci n de polaridad que figura en el interior del compartimiento Vuelva a colocar en el termostato Cuando las pilas est n bajas el termostato empieza a funcionar en modo baja energ a El modo pila baja
23. materials and workmanship under normal use and service for a period of five 5 years from date of purchase This warranty and our liability does not apply to batteries or merchandise that has been damaged by misuse neglect mishandling alterations improper installation or use in a way other than in accordance with Invensys Controls recommendations and instructions Invensys Controls agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period postage prepaid with proof of the date of purchase Cost of thermostat removal or reinstallation is not the responsibility of Invensys Controls Repair or replacement as provided under this warranty is the exclusive remedy of the consumer Invensys Controls shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product or under any other theory of liability Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For warranty re
24. miento la segunda etapa Ver Sistemas de dos etapas JM e Lic J DEDB margen de oscilaci n para conmutaci n autom tica cantidad de grados que la temperatura ambiente puede alejarse del valor deseado hasta que empiece a funcionar el modo calefacci n o refrigeraci n Cuanto m s amplio sea el margen de oscilaci n m s variar la temperatura ambiente Esto funciona de calefacci n a refrigeraci n y viceversa setae HI limite superior de temperatura es el valor mas elevado de ajuste de calefacci n El usuario no podr fijar un valor deseado programado ni temperatura del Modo Sobrecontrol por encima de este valor lt m LO l mite inferior de temperatura es el valor inferior de ajuste de refrigeraci n El usuario no podr fijar un valor deseado programado ni temperatura del Modo Sobrecontrol por debajo de este valor VAC HEAT valor deseado de calefacci n en vacaciones es el valor deseado de temperatura para el sistema de calefacci n cuando se activa el Modo Sobrecontrol por vacaciones C7 Eder VAC COOL valor deseado de refrigeraci n en vacaciones es el valor deseado de temperatura para el sistema de refrigeraci n cuando se activa el Modo Sobrecontrol por vacaciones a ay nm OC cog E sra CHECK recordatorio para realizar el mantenimiento del filtro Por defecto este control est desactivado El temporizador funciona cuando el sistema se enciende y se
25. mming This means the 5 weekdays will operate on one schedule and the 2 weekend days will operate on a second schedule AL IMPORTANT SAFETY INFORMATION WARNING e Always turn off power at main fuse or circuit breaker panel before installing removing cleaning or servicing thermostat e Read all the information in this manual before installing this thermostat e This is a 24V AC low voltage thermostat Do not install on voltages higher than 30V AC e All wiring must conform to local and national building and electrical codes and ordinances Do not short jumper across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty e Do not connect ground to any terminal in this unit e This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages Short cycle protection provides a delay between heating and cooling cycles on heat pumps Detailed mounting and wiring instructions are explained in the Installation Manual Refer to the Pop Up Wizard section in the Installation Manual for a complete list of factory defaults and contractor settings Providing Power to the Thermostat For wiring diagrams refer to the Installation Manual The thermostats will operate using 24V AC or two AA batteries When the two AA batteries are installed the thermostat will continue to run if the 24V AC fails
26. ng emergency heat contact your contractor Use the 4 2 button to enter the EMER mode An E will be displayed with the Heat symbol This mode is used to bypass the heat pump when it needs servicing or when it cannot keep up with the heat demand Auto Changeover Auto changeover is the ability of the thermostat to switch automatically between heating settings and cooling settings This is useful in spring and fall when the days are warm and the nights are cool In heat mode if the room continues to warm beyond a set threshold the thermostat switches to the cool mode and the associated cooling settings The reverse is also true As the room temperature changes the thermostat will call for heating or cooling as needed To prevent the heating and cooling systems from overriding each other an automatic changeover deadband is used The deadband is the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for The larger the deadband the more the room temperature will vary Making Changes to the Programmed Settings Any setting can be changed when itis flashing by pushing 42 or Y If a button is not pushed within 10 seconds the thermostat returns to operation The following buttons can be accessed from the front panel START STOP SCHEDULE Switches between running a schedule and manual permanent override Cancels a temporary or vacation override EDIT SCHEDULE Use this button
27. now function properly using the default schedule Default Settings This thermostat is preprogrammed with a schedule that is recommended by EnergyStar The schedule is designed to lower energy costs year round The default schedule settings are Time Cooling F Heating F Morn 6 00 am 78 70 Day 8 00 am 85 62 Eve 6 00 pm 78 70 Nite 10 00 pm 82 62 User Programmable Settings Default During any program changes the display returns back to the operating display if a button has not been pushed within 10 seconds The temperature scale is set to Fahrenheit The night light is off The first stage differential is 1F degree The second stage differential RS5220 is 2F degrees The auto changeover deadband is 3F degrees The filter reminder length is off The temperature offset is 0 degrees The HI heat limit is 90 F 32 C The LO cool limit is 45 F 7 C The vacation temperature settings are set at heating 62 F cooling 85 F The operation mode will be one of the following The fan setting is Auto Off Heat Cool E Emergency Heat E Automatic Changeover A The keypad has no password protection Refer to the Pop Up Wizard section in the Installation Manual for a complete list of factory defaults and contractor settings Emergency Heat Your system may include Emergency Heat The RS5220 thermostats have an emergency heat capability for multi stage heat pump systems To determine if your system is capable of usi
28. nstalaci n del termostato no es responsabilidad de Invensys Controls La reparaci n o el reemplazo previstos en la garant a constituyen el nico recurso del consumidor Invensys Controls no ser responsable de los da os incidentales o emergentes por la violaci n de cualquier garant a expresa o impl cita de este producto o de cualquier otra teor a de responsabilidad Salvo en la medida en que lo proh ba la legislaci n correspondiente toda garant a impl cita sobre la comerciabilidad o aptitud de este producto para un fin espec fico se limita a la duraci n de esta garant a Algunos estados no permiten la exclusi n ni la limitaci n de da os incidentales o emergentes ni permiten limitaciones sobre la duraci n de las garant as impl citas por lo que es posible que la limitaci n o exclusi n anterior no corresponda a su caso Esta garant a le otorga derechos legales espec ficos y quiz s usted tambi n tenga otros derechos legales que var en de un estado a otro Para devoluciones en garant a env e el termostato con gastos de env o prepagos a Invensys Controls Warranty Claims Department 515 S Promenade Corona CA 91719 En Canad Invensys Controls 3505 Laird Road Unit 14 Mississauga Ontario L5L 5Y7 Canada Attn Warranty Department invensys Controls 515 South Promenade Avenue Corona CA 92879 1736 United States of America www invensyscontrols com 2007 Invensys Controls 8 07 352 00056 001 N
29. omun quese con el contratista Use las teclas para ingresar en el modo EMER Aparecer una E con el s mbolo de calefacci n Este modo se usa para hacer un bypass a la bomba de calor cuando sta necesita reparaci n o cuando no puede dar abasto con la demanda de calefacci n Conmutaci n autom tica La conmutaci n autom tica es la posibilidad que tiene el termostato de cambiar autom ticamente del modo calefacci n al modo refrigeraci n y viceversa Esta funci n es til en primavera y oto o cuando los d as son c lidos y las noches son frescas En el modo calefacci n si la habitaci n se sigue calefaccionando por encima del umbral fijado el termostato cambia autom ticamente al modo refrigeraci n y los valores programados correspondientes Tambi n funciona en sentido inverso A medida que cambia la temperatura el termostato pedir calefacci n o refrigeraci n seg n necesite Para evitar que los sistemas de calefacci n y refrigeraci n se anulen entre s se establece un margen de oscilaci n para la conmutaci n autom tica El margen de oscilaci n es el rango en cantidad de grados que la temperatura ambiente puede alejarse del valor deseado hasta que empiece a funcionar el modo calefacci n o refrigeraci n Cuanto m s amplio sea el margen de oscilaci n m s variar la temperatura ambiente Para cambiar los valores programados E Cuando los valores programados titilan se pueden modificar presionando l
30. ostat to display a temperature that is 2 degrees higher than the actual room temperature Security Lockout to Protect the Settings The buttons on the front of the thermostat can be locked with a password To create a password 1 Press the and dE buttons at the same time and hold them in for 5 seconds You will be asked for a 4 digit password 2 Each digit is set using the amp and W buttons Press the to move to the next digit Press s3 to move back 3 The password is saved after 10 seconds or by pressing lt and atthe same time All of the front buttons are now locked out until the password is entered Pressing any button will cause A to flash To unlock the buttons 1 Push and hold the and buttons for 5 seconds until the request for password is displayed 2 Enter the digits for the password by pressing the 4 and V buttons Press the to move to the next digit Press to move back If the wrong password is entered the display will flash NO for 5 seconds then return to normal 3 Press 4h and when the correct password is displayed The buttons will be unlocked Once the security has been disabled a password needs to be recreated to protect the settings Two Stage Systems A 2nd stage is a second or additional system that will provide extra heating or cooling When a 2nd stage is operating the display will show the number 2 by the heating and cooling icons A programmable temperature differenti
31. programas Cuando el termostato est funcionando conforme a un programa el modo sobrecontrol le permite al termostato funcionar con un nico valor deseado durante un cierto tiempo Se ingresa el Modo Sobrecontrol temporario como un nuevo valor deseado durante una cierta cantidad de horas Se ingresa el Modo Sobrecontrol por vacaciones como un valor deseado durante una cierta cantidad de d as Modo Sobrecontrol temporario 1 Pulse las teclas s o W para mostrar los valores deseados y la cantidad de horas 2 Pulse las teclas 4 y W para modificar el valor deseado 3 Pulse SET TIME para pasar a las horas 4 Use las teclas 4 y W para fijar la duraci n de la cancelaci n Despu s de 5 segundos el termostato empezar a funcionar en el modo sobrecontrol El visor mostrar la temperatura ambiente y el valor deseado aparecer intermitentemente con la cantidad de horas que quedan en el modo sobrecontrol Cuando termine el tiempo programado en el modo sobrecontrol se reanudar el programa Se debe elegir el modo calefacci n o refrigeraci n Cancele el modo sobrecontrol pulsando START STOP SCHEDULE PROGRAMA INICIO DETENCI N aa 7 al e FOR WI s Modo Sobrecontrol por vacaciones Este modo se programa pulsando VACATION Comenzar a destellar la cantidad de d as Pulse las teclas 4 y W para modificar la cantidad de d as Despu s de 5 segundos el termostato empezar a funcionar en el modo 12 sobrecontrol
32. r heat or cool to maintain the setpoint temperature Press Aa or W to change the setpoint The heat or cool mode should be selected Schedule Overrides When the thermostat is following a schedule an override allows the thermostat to function with a single setpoint for a time period A temporary override is entered as a setpoint for a number of hours A vacation override is entered as a setpoint that is held for a number of days Temporary Override 1 Press 4 or W to display the flashing setpoint and the number of hours 2 Use 4 and W to change the setpoint 3 Press SET TIME to move to the hours 4 Use 4 and W to setthe length of the override After 5 seconds the thermostat will start operation of the override The display will show room temperature and the setpoint will alternate with the number of hours remaining in the override The schedule will resume after the programmed override time expires Heat or cool must be selected Cancel the override by pressing START STOP SCHEDULE Vacation Override This override is programmed by pressing VACATION The number of days will flash Use 4 and W to change the number of days After 5 seconds the thermostat will begin operation of the vacation override The display will show room temperature and the setpoint will alternate with the number of days remaining in the override Use 4 and W to change the setpoint This will become the new setpoint for future vacation overrides
33. s e Cierre autom tico de calefacci n si la temperatura supera los 99 F 37 C e Bloqueo del teclado e 4 eventos por dia para calefacci n y refrigeraci n e Programable para 5 2 d as e L mites superior e inferior de temperatura a elecci n del usuario e Modo sobrecontrol por vacaciones Aplicaci n La familia de termostatos Robertshaw 5000 est dise ada para controlar sistemas de refrigeraci n el ctrica y de calefacci n de gas electricidad petr leo bombas de calor y minivolt El modelo RS5110 es un termostato de una sola etapa y el RS5220 es un termostato de dos etapas Los termostatos RS5000 usan programaci n 5 2 Es decir que durante los 5 d as de semana funcionan con un programa y durante los 2 d as del fin de semana funcionan con un segundo programa AA ADVERTENCIAS IMPORTANTES SOBRE SEGURIDAD e Interrumpa siempre el suministro de electricidad desde la llave principal o desde el panel del disyuntor antes de instalar retirar limpiar o reparar el termostato e Lea toda la informaci n que aparece en este manual antes de instalar el termostato Este es un termostato de bajo voltaje 24V CA No instale con voltaje superior a 30V CA e Todas las conexiones de cableado deben cumplir con las normas y disposiciones locales y nacionales que rigen en materia de construcci n y electricidad No deben puentearse los terminales de la v lvula de gas ni el control del sistema para probar la instalaci n Esa pr ct
34. the three ON The fan is on constantly The room temperture set points and status of the heating and cooling equipment has no effect on the fan AUTO When there is a call for heating or cooling the fan will turn on CIRC The fan operates in a cycle of on for 10 minutes and off for 20 minutes When there is a call for heating or cooling the cycle stops and the fan responds to the call The fan circulation cycle resumes when the call for heating or cooling is satisfied Troubleshooting Problem Action Thermostat does not turn on system Check wiring see Wiring Diagrams section in the Installation Manual System turns on too often Increase temperature differential see To Make Changes to the Settings section System fan does not operate Move fan option switch to either properly gas or electric to match system see Setting the Fan to ON AUTO or CIRC section Thermostat does not display Check F C Fahrenheit Celsius setting proper room temperature see To Make Changes to the Settings section Display shows HI or LO and room Call a licensed service person to temperature is normal replace repair If problems with thermostat cannot be resolved contact www invensyscontrols com or Technical Support 800 445 8299 Five Year Limited Warranty Invensys Controls warrants to the original contractor installer or to the original consumer user each new Robertshaw thermostat to be free from defects in
35. tiene dos niveles e NIVEL 1 Aparece en el visor el cono de pila baja El termostato sigue funcionando Cambie las pilas lo h 7 antes posible e NIVEL 2 Titila intermitentemente el cono de pila s I e baja Si llega corriente de la red el ctrica de 24V CA h 7 el sistema seguir funcionando aunque las pilas Y 1 est n descargadas o se saquen Si el sistema no recibe corriente el ctrica y el termostato s lo funciona con pilas EL SISTEMA NO FUNCIONARA Cambie las pilas inmediatamente El reloj seguir funcionado durante 10 minutos sin pilas Cambie las pilas si el termostato quedar sin atenci n durante m s de 30 d as Mapa del visor El visor del termostato muestra la informaci n que se usa durante el funcionamiento o la programaci n El dibujo muestra las posibilidades del visor y la explicaci n 1 2 4 MORN MON TUE WED THU FRYSAT SUN DAY Oa QEEVACISCHEDULEJFOR EVE ICHECK SET AT NITE oT Cn 1 Re T N Dm Ltrs AUTI VAC Eq x alo MAA A 7m Pros o Event names used for editing schedule Day is displayed on IDLE screen Also used to display day ranges when editing the schedule e g SAT SUN for weekend Used with clock to display hold duration e g FOR 2h Displayed when running a schedule Used with setpoint Used along with clock for service reminders e
36. tting can be changed DIFF The differential keeps the thermostat from turning on for small changes in temperature When in Fahrenheit the range is 0 5 to 3 0 degrees In Celsius the range is 0 5 to 1 5 degrees The differential is factory set to 1 0 F degree 0 5 C degree This means that whenever the room temperature is more than 1 F degree 0 5 C degree different from the set temperature the system will turn on If the system is turning on too often increase the differential setting Note that a larger differential will mean the room temperature changes more before the system turns on moos oT ia TE DIF2 SECOND STAGE DIFFERENTIAL Operates with the first stage to control a second heating cooling system This number will be added to the first stage differential See Two Stage Systems If the first stage is running too often lower the settings This will turn the second stage on to help the first stage If both stages are turning on too often increase this setting to delay the second stage HED Fe Ls DLY2 SECOND STAGE DELAY This timer starts when the first stage turns on It resets when the first stage turns off If this timer expires the second stage will turn on See Two Stage Systems DEDB Deadband for auto changeover the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for The larger the deadband the more the room temperature will v
37. turns send thermostat shipping prepaid to Invensys Controls Warranty Claims Department 515 S Promenade Corona CA 91719 In Canada Invensys Controls 3505 Laird Road Unit 14 Mississauga Ontario L5L5Y7 Canada Attn Warranty Department Invensys Controls 515 South Promenade Avenue Corona CA 92879 1736 United States of America www invensyscontrols com 2007 Invensys Controls 8 07 352 00056 001 NOTES RS4110 RS4220 RS5110 RS5220 RS6110 RS6220 352 00056 001 MANUAL DEL USUARIO Gracias por comprar un termostato programable Robertshaw Serie RS5000 El manual le ayudar a programar el modelo RS5110 de una sola etapa y el modelo RS5220 de dos etapas El termostato debe estar instalado y conectado adecuadamente a la red de electricidad Los ajustes por defecto permiten el funcionamiento eficiente del termostato Antes de realizar cambios en la programaci n lea la secci n Ajuste por defecto Caracter sticas e Asistente desplegable e Conmutaci n autom tica e Ventilador de circulaci n e Retenedor de memoria Worry Free e F cil cambio de pilas e Visor grande con iluminaci n posterior e Recordatorio de cambio de filtro e Indicador de pilas bajas e Visor en grados Fahrenheit y Celsius Cumple con las normas EnergyStar e Sistema dual de energ a e Diferenciales ajustables de temperatura 0 5 F a 3 0 F 0 5 C a 1 5 C e Precisi n de 1 F e Unidades con etapa universal o etapas m ltiple