Home

Rheem Tankless Mid-Efficiency 64 Direct Vent Indoor Specification Sheet

image

Contents

1. Environmentally friendly Ultra Low NOx burner meets SCAQMD rule 1146 2 requirements High Altitude Compliant High altitude capability up to 9 840 ft elevation above sea level Plus Digital remote control and 10 ft of thermostat wire included Supplied with a 120 volt power cord indoor models only Freeze protection to 30 F Required manual gas isolation valve included EZ Spec Sizing Software advanced online tool that takes the guess work out of sizing tankless applications available at www rheem com tankless Warranty 12 Year on heat exchanger residential 5 year on heat exchanger commercial 5 year on parts and 1 year on labor See Warranty Certificate for complete information PRINTED IN U S A 10 13 WP FORM NO TK 808 Rev 3 Water INTEGRATED HOME COMFORT Residential Gas RTG Tankless Water Heaters INTEGRATED HOME COMFORT INTEGRATED HOME COMFORT Rheem RTG is a series of ultra low NOx mid efficiency tankless gas water heaters designed for continuous hot water RTG DVL Indoor Direct Vent Model 11 000 199 900 Btu h Natural and LP Gas RTG XL Outdoor Model 11 000 199 900 Btu h Natural and LP Gas Commercial Applications RTG Tankless Series can be upgraded for high temperature commercial and hydronic use Temperature range is 85 F to 185 F RTG 95 Upgrade Kits RTG20236A for RTG 95DVLN RTG20236B for RTG 95DVLP RTG20236C for RTG 95XLN
2. RTG20236D for RTG 95XLP RTG 84 Upgrade Kits RTG20237A for RTG 84DVLN RTG20237B for RTG 84DVLP RTG20237C for RTG 84XLN RTG20237D for RTG 84XLP Note These upgrade kits are not compatible with previous models See the 2012 Tankless Parts Catalog for a complete listing Based on simultaneous showers using 2 5 gallons per minute Flow rates vary depending on temperature of cold water supply LEED Points 2 2 ProClub Points 2 ProClub Points myrheem com proclub PRINTED IN U S A 10 13 WP FORM NO TK 808 Rev 3 2 Rheem Water Heating 101 Bell Road Montgomery Alabama 36117 4305 www rheem com Rheem Canada Ltd Lt e 125 Edgeware Road Unit 1 Brampton Ontario L6Y 0P5 www rheem com INTEGRATED HOME COMFORT INTEGRATED HOME COMFORT Water INTEGRATED HOME COMFORT Residential Gas RTG Tankless Water Heaters In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice Specifications RTG 95DVLN 11 000 Indoor 85 to 4 3 7 4 9 5 3 4 3 4 25 5 8 13 7 8 9 7 8 3 by 5 54 82 84 199 482 199 900 Direct Vent 140 F CONCENTRIC RTG 95XLN 11 000 Outdoor 85 to 4 3 7 4 9 5 3 4 3 4 23 5 8 13 7 8 8 7 8 N A 54 82 83 199 482 199 900 140 F RTG 84DVLN 11 000 Indoor 85 to 3 9 6 7 8 4 3 4 3 4 25 5 8 13 7 8 9 7 8 3 by 5 54 82 84 199 482 180 000 Direct Vent 140 F CONCENTRIC RTG 84XLN 11 000 Outdoor 85 to 3 9 6 7 8 4 3 4 3 4 23 5
3. 8 13 7 8 8 7 8 N A 54 82 83 199 482 180 000 140 F RTG 64DVLN 11 000 Indoor 85 to 3 3 5 6 6 4 3 4 3 4 25 5 8 13 7 8 9 7 8 3 by 5 54 82 84 199 482 150 000 Direct Vent 140 F CONCENTRIC RTG 64XLN 11 000 Outdoor 85 to 3 3 0 26 0 40 0 26 0 40 0 26 0 40 0 26 0 40 0 26 0 40 0 26 0 40 5 6 6 4 3 4 3 4 23 5 8 13 7 8 8 7 8 N A 54 82 83 199 482 150 000 140 F DESCRIPTION FEATURES ROUGHING IN DIMENSIONS SHOWN IN INCHES ENERGY INFO GAS MIN FLOW GPM GPM SHIP D O E ANN MODEL INPUT TEMP ACTIVATION 77 RISE 45 RISE MAX CONNECTION VENT WEIGHT ENERGY RECOVERY OP COST NUMBER BTU H TYPE RANGE GPM MAX MAX GPM WATER GAS HEIGHT WIDTH DEPTH DIAM LBS FACTOR EFFICIENCY NAT LP RTG 95 ULTRA LOW NOx SERIES FOR 3 BATHROOM HOMES RTG 84 ULTRA LOW NOx SERIES FOR 2 3 BATHROOM HOMES RTG 64 ULTRA LOW NOx SERIES FOR 1 2 BATHROOM HOMES Indoor Direct Vent Energy Factor and Average Annual Operating Costs based on 2013 D O E Department of Energy test procedures D O E national average fuel rate natural gas 1 09 therm LP 2 41 gallon All models are available in Natural Gas and Propane LP For Propane replace the N with P when ordering SCQAMD rule 1146 2 compliant Factory set maximum temperature is 120 F See Use and Care Manual for setting Consult factory for information on sizing the application Add a C to the model number when ordering Canadian models Outdoor models are only for se
4. Efficiency 82 EF with all copper heat exchanger Intelligent electronic controls designed to increase energy efficiency and safety Third party efficiency listed by AHRI Performance Industry First 0 26 GPM minimum flow rate 0 40 GPM minimum activation flow rate RTG 95 for 3 bathroom homes 9 5 gal min at 35 F rise max 8 4 gal min at 45 F rise RTG 84 for 2 3 bathroom homes 8 4 gal min at 35 F rise max 6 6 gal min at 45 F rise RTG 64 for 1 2 bathroom homes 6 4 gal min at 35 F rise max 5 6 gal min at 45 F rise Self Diagnostic System Self diagnostic system for easy installation and service Digital display shows temperature setting and maintenance codes Technology 3 5 concentric vent system with Integrated condensate collector Hot start programming helps minimize fluctuation in water temperature referred to as cold water sandwich during periods of frequent on off operation Connects to Metal Fab Inc 3 5 concentric venting without an adapter Built in electric blower Exclusive Guardian overheat film wrap OFW EZ Link cable available for higher demand applications to connect two tankless units to operate as one Manifold up to six units with an optional MIC 6 manifold control board Manifold up to 20 units with the optional MIC 185 plus the MICS 180 manifold control assembly Low Emissions
5. asonal use in Canada Please contact Rheem Canada Ltd for details Vent Termination Kits are required for Direct Vent models Contact your distributor for details Proper gas pressure must be ensured to supply tankless gas water heaters up to 199 900 Btu h for RTG 95 models up to 180 000 Btu h for RTG 84 models and up to 150 000 Btu h for RTG 64 models Consult your gas supplier 0 1 2 3 4 5 6 7 8 9 10 10 20 35 45 50 60 70 77 80 90 100 120 140 Water Heater Flow Rate Curves Delta T GPM 95 Series Max Flow 84 Series Max Flow 64 Series Max Flow temperature Rise F Model number 35 45 50 60 70 77 80 90 100 RTG 95 Water Flow GPM 9 5 7 4 6 6 5 5 4 7 4 3 4 1 3 7 3 3 RTG 84 Water Flow GPM 8 4 6 7 6 1 5 1 4 3 3 9 3 8 3 4 3 0 RTG 64 Water Flow GPM 6 4 5 6 5 1 4 2 3 6 3 3 3 2 2 8 2 5 Above estimates are for sizing purposes only 3 5 Concentric 5 1 2 25 5 8 13 7 8 9 7 8 1 1 8 4 5 3 3 4 4 5 8 5 1 4 Dimensions from Center Line Outdoor 1 1 8 5 23 5 8 13 7 8 8 7 8 2 1 2 3 3 8 5 1 4 Dimensions from Center Line 2 3 4 Parts and Accessories Venting amp terminations recess boxes pipe covers extra remote controls EZ Link manifolds and cables service valve kits service parts flush kits For more information o
6. n Tankless parts and accessories see the Parts and Accessories catalog or call 866 720 2076 number Maximum of 90 Length of Elbows straight Pipe 1 39 0 ft 12 0 m 2 37 5 ft 11 5 m 3 36 ft 11 m 4 34 5 ft 10 5 m 5 33 0 ft 10 0 m 6 31 5 ft 9 5 m Maximum Vent Length intake outlet Manufacturer approved venting required

Download Pdf Manuals

image

Related Search

Related Contents

Gainward GeForce 210 1024MB DDR2 NVIDIA GeForce 210 1GB  Bedienungsanleitung  Samsung RM25KGRS Manuel de l'utilisateur  POLÍTICA DE COOKIES En esta página web se utilizan  Dixon 966516601 Lawn Mower User Manual  正常ヒト皮膚3次元モデル関連製品購入ガイド  Pack Gestion du Temps  LPC501 MANUAL  BJ-1700/1800 型 取扱説明書  Hama Basic 3050  