Home
Renesas SH7201 User's Manual
Contents
1. Reset button on the RSK and press lt Enter gt or click lt OK gt Loading flash memory C Disable Enable Erasing flash memory C Disable Enable File name C workSpace tutorial_rsks Braise Ph Bus width of flash memory 16 bit bus width Flash memory erasing time D S minute Entry point 37 HEW will connect to the target system 38 Click on the Emulator System button in HEW 39 The Configuration dialog will appear select the Loading Flash memory tab Alletasing module address FFFGIOOD Writing module address HFFF81100 40 Selectthe Enable radio on both loading and erasing flash memory Access size 41 Click the lt Browse gt button and navigate to the project folder Usually located in c WorkS pace lt project_name gt and select the fmtool_e10a mot file click lt Open gt 42 Check the settings against the picture to the right 43 Click lt OK gt on the Configuration dialog 44 Right click on the lt project_name gt abs file listed in the download modules area of the Download me Workspace view and select Download 5 Se orioa 45 The Downloading program window will show the progress of the download once E i nee ia completed it will disappear Int 46 Next the Disassembly view will show a AEA e 47 Click the Go button z 48 The code will run You will see the LEDs flashing on the board After pressing any of the u
2. Everywhere you imagine E lt E NI ESAS Vx Us wh we tes amp Renesas Starter Kit for SH7201 Reset switch User LEDs Power jack E10A for Starter Kits Debug Module rahe In UK J feat RIL IS Wee ASHKSHTo01 1 Sii Serlal Number 65790 y tees ail y y sa TOS am a is tre atl aa BEDR CE Application headers Analog adjust i A a K La 10 TE User switches E10A connector 1 Installation Do not connect the E10A module until the software support has been installed 1 Insert the CD into your computer s CD ROM drive The CD should automatically run the installation program If the installer does not start browse to the CD root folder and double click on setup exe The installer will ask you which language Is to be used please choose the appropriate one and click lt OK gt On the first screen of the installer proper click lt Next gt The License Agreement will be shown read and click lt Y es gt The next screen asks you to pick the world region please select and click lt Next gt Select the RSK you wish to install and click lt Next gt to continue The destination folders are specified on the next screens It is recommended to accept the default settings Click lt Next gt to continue Click lt Next gt on all screens until the Installation process commences O ee St Ss St he CU After the installation the machine s site code will be shown this is not
3. common graphical user interface To learn more on how to use HEW open the HEW manual installed on your computer Start Menu gt All Programs gt Renesas gt High performance Embedded Workshop gt Manual Navigator 19 20 21 22 23 24 25 26 Zi 28 29 30 Launch HEW from the Start Menu Start Menu gt All Programs gt Renesas gt High performance Embedded Workshop In the Welcome dialog box Verify Create New Workspace Is selected Click lt OK gt In the New Project Workspace dialog box Verify the CPU Family is setto SuperH RISC engine Select EL0A_RSKSH7201 from the left hand pane Enter a name for the workspace The project name will be automatically completed with the Workspace name You can change this name to Tutorial if required Click lt OK gt On the E10A_ RSKSH7201 Step 1 window Select Tutorial and click lt Next gt On the E10A_RSKSH 7201 Step 2 window Click lt Finish gt On the Project Generator Information window Click lt OK gt The project that is created has two configurations The Release configuration compiles the project without any debugger support and can be used for the final release code version Select the Debug build configuration in the left hand drop down list on the tool GessionSH2A FPU_E104 bar Click on the Build icon to compile assemble and link the project Programming and Debug Sel
4. ect the SessionSH2A FPU_E10A USB SYSTEM session in the right hand Debug drop down list on the tool bar an Click the lt Connect gt button on the debug toolbar The Select Emulator mode dialog will appear Select the device SH7201 and the E10A USB Emulator radio button and click lt OK gt Device E Hse STP Saale f Writing Flash memory Cancel If this isn t the first time you have used the E10A module with this RSK please skip to step 35 D007124 11_S01_V03 First use of the E10A module 31 The Please choose driver dialog will be shown Click lt OK gt Driver Details Driver kno driver selected gt 32 The Driver Details dialog will be shown please select Renesas E Series USB Driver as illustrated The I 1 l 1 i A Detail Renesas E Series USB Driver Interface and Channel items will be automatically populated Click lt Close gt Interface 33 The Firmware setup dialog will be shown warning you not to disconnect the USB cable until the firmware a download is complete Click lt OK gt The firmware will be downloaded to the E10A module this will take a few moments seers Please do not disconnect the E10A from the host during download doing so is likely to damage the E10A module Close Configuration 35 A box will appear Please reset the user system and press lt Enter gt key General Loading flash memory 36 Press the
5. for access to the web After restarting the machine the Icon will appear in the System Tray next to the clock To change the settings or access Autoupdate simply right click on the icon and use the menu that appears Renesas Solutions Corporation 2008 Renesas Technology Corporation 2008 Renesas Technology Europe Ltd 2008 D007124 11_S01_V03
6. important at this stage click Next gt then lt F inish gt 10 The Auto update dialog box will be launched Configure the Auto update settings dialog to allow your installation to be checked for updates D007124 11_S01_V03 11 12 13 14 15 16 17 18 Connection Connect the E10A module to the E10A connector on the RSK using the ribbon cable Plug in the LCD module to LCD connector on the RSK ensuring that the pin 1 designation corresponds to the marking on the RSK Connect the 5V power supply unit to the power jack on the RSK board and apply power The green Power LED located on the RSK will illuminate Connect the E10A module to a spare USB port on your PC The green ACT LED on the RSK will illuminate The Found New Hardware Wizard will appear Please follow the steps below to install the drivers Note that administrator privileges are required for a Windows 2000 XP machine If offered do not use the Windows Update option to locate the driver Verify the Recommended option Renesas E Series USB Driver is selected and click Next gt If using Windows XP skip to step 18 otherwise click lt Next gt Click lt Next gt to install the driver Click lt Finish gt to close the wizard Note The Windows driver signing dialog may be displayed Please accept the driver to continue 3 HEW Workspace HEW integrates various tools such as compiler assembler debugger and editor into a
7. ser switch the rate of flashing can be adjusted using the Analog Adjust control 49 Click the Stop button pni The code will stop and the source code opened at the current program counter 5 Next Step After you have completed this quick start procedure please review the tutorial code and sample code that came with the kit You can add projects to the current workspace by selecting Project gt Insert Project from the main menu The tutorials will help you understand the device and development process using Renesas Development Tools The Hardware manual supplied with this RSK is current at the time of publication Please check for any updates to the device manual from the Renesas website at www renesas com renesas starter kits D007124 11_S01_V03 6 Renesas SuperH Compiler The version of the compiler provided with this RSK is fully functional but time limited You have 60 days to evaluate the full product before the compiler will limit the code linker to 256k bytes Full licensed SH compiler versions are available from your Renesas supplier 7 Support Online technical support and information is available at www renesas com renesas Starter kits Technical Contact Details America techsupport rta renesas com Europe tools support eu renesas com J apan csc renesas com Note on Autoupdate The Autoupdater is configured to automatically add itself to the Startup folder in the Windows Start Menu and use the registry defaults
Download Pdf Manuals
Related Search
Related Contents
Finisar FTLX1442E2 network transceiver module sciences sociales - School of Social Science YKK社製商品の保証についてはこちらをご覧下さい 取扱説明書 nHB Serial to RS422/485 Converter Serial to RS422/485 Converter CP-134U Series User`s Manual Sony WM-EQ7 User's Manual DeLOCK 82710 Samsung LA32A650A1R راهنمای محصول Copyright © All rights reserved.
Failed to retrieve file