1. Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Cable head amp gt j IC socket NQPACK144SD Unitrin manufactured by Tolerance 0 5 mm Tokyo Eletech Corporation a User system Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12 RENESAS Section 3 Installing the MCU to the User System CAUTION Check the location of pin 1 before inserting Use the screwdriver provided for tightening screws The tightening torque must be 0 054 Nem or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin before inserting the MCU into the IC socket on the user system as shown in figure 9 After inserting the MCU fasten the socket cover with the provided four screws M2 x6 mm Take special care such as manually securing the IC socket soldered area to prevent the IC socket from being damaged by overtightening the screws or twisting the
2. components RENESAS Screws M2 x 6 mm lt Socket cover MCU Pin 1 C socket NQPACK144SD manufactured by Tokyo Eleteck Corporation User system 14 Figure 9 Installing MCU to User System RENESAS Section 4 Verifying Operation 1 When using the E6000 emulator for the H8S 2338 series turn on the emulator according to the procedures described in the E6000 Series Emulator User s Manual HS2000EPI61HE 2 Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command emulator command If an error is detected recheck the soldered IC socket and the location of pin 1 3 The emulator connected to this user system interface cable supports two kinds of clock sources as the MCU clock an emulator internal clock and an external clock on the user system For details refer to the Emulator Supplementary Information HS2338EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To use the external clock on the user system Supply the external clock from the user system to the emulator Connect a crystal oscillator to the EXTAL and XTAL terminals for the system clock Select the external clock as the system clock by using the CLOCK command emulator command For details refer
3. for the user system IC socket are different from those of the MCU 3 This user system interface cable is specifically designed for the HS2338EPI61H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 11 Place components so that the cable body and cable head are parallel to the user system Emulator station Cable j Cable head is parallel to emulator station H i ll Cable head is parallel to user system User system Figure 11 User System Interface Cable Location Example 6 The P1 short connector is used for testing Do not remove the short pin that is inserted in the sides of pin I and pin 2 Figure 12 P1 Short Connector 17 RENESAS
4. H8S 2338 Series QFP 144 User System Interface Cable HS2338ECH61H for E6000 Emulator User s Manual r8atENESAS HS2338ECH61HE D Cautions Renesas neither warrants nor grants licenses of any rights of Renesas s or any third party s patent copyright trademark or other intellectual property rights for information contained in this document Renesas bears no responsibility for problems that may arise with third party s rights including intellectual property rights in connection with use of the information contained in this document Products and product specifications may be subject to change without notice Confirm that you have received the latest product standards or specifications before final design purchase or use Renesas makes every attempt to ensure that its products are of high quality and reliability However contact Renesas s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other ch
5. aracteristics Renesas bears no responsibility for failure or damage when used beyond the guaranteed ranges Even within the guaranteed ranges consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail safes so that the equipment incorporating Renesas product does not cause bodily injury fire or other consequential damage due to operation of the Renesas product This product is not designed to be radiation resistant No one is permitted to reproduce or duplicate in any form the whole or part of this document without written approval from Renesas Contact Renesas s sales office for any questions regarding this document or Renesas semiconductor products Preface Thank you for purchasing this user system interface cable HS2338ECH61H for the Renesas s original microcomputer H8S 2338 series The HS2338ECH61H is a user system interface cable that connects an H8S 2338 series E6000 emulator HS2338EPI61H hereinafter referred to as the emulator to the IC socket for a QFP 144 package package code FP 144 for the H8S 2338 series MCU on the user system RENESAS Contents NAL Ne 1 Section 2 Connection Procedures sis sirenerne rn 4 2 1 Connecting User System Interface Cable to Emulator Station serornnorrrovnrrnrrnernvrvreverere 4 2 2 Connecting User System Interface Cable to User System s snrrnannnnrnvrnnvrvrnvnvrvernernevreen 5 22 1 Instalime IC S
6. er system CAUTION Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU RENESAS 2 2 2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin on the IC socket for a FP 144 system interface cable head into the IC socket on the user system as shown in figure 4 2 2 3 Fastening Cable Head CAUTION 1 Use the screwdriver provided for tightening screws 2 The tightening torque must be 0 054 Nem or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary RENESAS Fasten the user system interface cable head to the IC socket for an FP 144 package on the user system with the four screws M2 x 10 mm provided Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or tw
7. ing sure the direction of the cable body connector is correct firmly insert the cable body connector into the emulator station socket figure 2 RENESAS Emulator station Figure 2 Connecting User System Interface Cable to Emulator Station 2 2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below RENESAS 2 2 1 Installing IC Socket 1 Confirming the location of IC socket CAUTION After confirming the location of pin 1 on the IC socket apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket and fasten it to the user system Use the guide pins provided to determine where to install the IC socket as shown in figure 3 Pin 1 tyje Guide pins 4 projections to apply epoxy resin adhesive to lt lt IC socket NQPACK144SD manufactured by Tokyo Eletech Corporation Bottom view of IC socket User system Figure 3 Location Setting of IC Socket 2 Solder the IC socket for a FP 144 package to the us
8. isting the components Screws M2 x 10 mm Cable head IC socket a NQPACK144SD 4 manufactured by Tokyo Eletech Coporation Pin 1 f User system Figure4 Connecting User System Interface Cable to User System RENESAS 2 2 4 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body User system Figure5 Fastening Cable Body RENESAS 2 3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad footprint for the user system with an IC socket for an FP 144 package NQPACK144SD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad ag 23 00 0 15 lg 11 50 gt ll ll tf a C o 0 1o EE SE E E S Q B o mol ug 2 00 0 10 il ll Y i a 0 50 0 25 max l Unit mm Tolerance 0 10 unless otherwise specified Figure 6 Recommended Dimensions for Mount Pad RENESAS 2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 48 6 63 5 Unit mm Tolerance 0 5 mm Figure 7 Dimensions for User System Interface Cable Head RENESAS 11 25 Resulting Dimensions after Connecting User System
9. ocketesity a i Het diate ES 6 2 2 2 Inserting Cable Head o sccascssskeascsenchastssaseaassensvensjonsnoiacsvscssesnbacveuecaneensseastarvenvacaonss 7 2 2 3 Fastering Cable Head ices nwshes iiescessessacvddvventvonts in aeo EEr OKOK A uasdenvces bek 7 2 2 4 Connecting Cable Body to Cable Head 00 0 ceeeeeeeeeeeeeeeeseeeeeeseeeeenaes 9 2 3 Recommended Dimensions for User System Mount Pad esornrrvonnorvrnnvrrrernernrrnennervrenerere 10 2 4 Dimensions for User System Interface Cable Head sornrnnennornrrvnnnevvrnnnrrvernernrenennervrenerere 11 2 5 Resulting Dimensions after Connecting User System Interface Cable onrnnorornrrnneren 12 Section 3 Installing the MCU to the User System ssrnrnvrnrvvrnrnvnrnnvnvvrnrvnrrenene 13 Section 4 Verifying O PSratiOMs aicsssizsnevaciensdahdavansaanavensactavaeveseaunaiuacasensesncoencaaanen 15 BOCHUM Notice seisnes rese eneret 17 ii RENESAS Section I Configuration CAUTION Use an NQPACK144SD socket manufactured by Tokyo Eletech Coporation for the FP 144 package IC socket on the user system Figure shows the configuration of the HS2338ECH61H user system interface cable for the FP 144 package RENESAS w emulator station IC socket Screws M2 x 10 mm SS for fastening cable head fo knr Cable head User system Figure1 HS2338ECH61H User System Interface Cable RENESAS Table 1 lists the HS2338ECH61H components Please make sure yo
10. to section 18 Clock Pulse Generator in the H8S 2338 Series H8S 2328 series Hardware Manual Figure 10 shows the oscillator circuit on the user system interface cable R1 1 MQ HCU04 To E6000 emulator EXTAL XTAL Figure 10 Oscillator Circuit RENESAS 4 In the H8S 2338 series MCU the interrupt signal pins can be selected by the register setting To trace the interrupt signals in the E6000 emulator select the interrupt signal pins by setting switch PS on the user system interface cable as shown in table 2 Table 2 Switch P5 Setting IRPAS Bit Value Interrupt Signal Pin Pin No P5 Setting IRQ4 40 0 IRQ5 34 Close between 2 and 3 Initial value IRQ6 33 setting at shipment IRQ7 32 IRQ4 105 1 IRQ5 106 Close between 1 and 2 IRQ6 107 IRQ7 108 5 In the H8S 2338 series MCU the WAIT signal pins can be selected by the register setting To trace the WAIT signals in the E6000 emulator select the WAIT signal pins by setting switch P4 on the user system interface cable as shown in table 3 Table 3 Switch P4 Setting WAITPS Bit Value Pin No P4 Setting 0 4 Close between 3 and 4 Initial value setting at shipment 1 108 Close between 1 and 2 16 RENESAS Section 5 Notice 1 Make sure that pin on the user system IC socket is correctly aligned with pin on the cable head before inserting the cable head into the user system IC socket 2 The dimensions of the recommended mount pad
11. u have all of these components when unpacking Table 1 HS2338ECH61H Components No Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP 144 package 4 Socket cover 1 For installing an FP 144 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For installing an FP 144 packaged MCU 7 Guide pins 1 mm 3 For determining the IC socket location 8 Screwdriver 1 For tightening screws 9 Documentation 1 User s manual for HS2338ECH61H this manual RENESAS Section 2 Connection Procedures 2 1 Connecting User System Interface Cable to Emulator Station A WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection or removal while making sure not to bend or twist the cable or connectors Otherwise the connectors will be damaged 2 After mak
Download Pdf Manuals
Related Search
Related Contents
E82*取扱説明書 American Standard 2096.016 Indoor Furnishings User Manual GE JGB920 User's Manual MDW-19QD VC-5DVD - ご利用の条件|取扱説明書|ケンウッド Samsung MJC-900A User Manual Sommario Sicurezza e manutenzione..................................................1 離ー〝ー===~離離 サーパフレックス MLA300 Manual de instalação e operação Manuel d`utilisation Copyright © All rights reserved.