1. 4 Use F2 to exit alpha mode and the screen will return to normal 5 Input numbers normally 6 Well Number is next Follow the same procedure as for Well Name 7 Key in Well Number es JKL 1 MNO C ON Example 45 gt L 4 5 ENTER VO ee J Well Number F4 Quit ENTR Accept 8 Wireline Job Type is next Follow the same procedure as for Well Name F Quit ENTR Accept 9 Key in Wireline Job Type Example COMPLETION Wireline Job Type COMPLETION Fa Alpha Fus Quit ENTR Accept Model DL 04 DATA LOGGER Page 8 of 38 Rev 1 70 User Manual Reliable Scale Corporation 10 Job Operator is next Follow the same procedure as for Well Name C 11 Key in Job Operator Han o ES gt dd Ex 5 8 ENTER eae 2 ae j Quit ENTR Accept Log Interval is next Intervals from 2 Log Intervals M seconds to 99 seconds between Min 2s Max 99s records are available Quit ENTR Accept 12 Key in the Interval Example 2 The DL 04 begins reading data every LOGGING 2 seconds 25b 42m 122m m 10 23 10 4990kg Fy Quit 000085 13 Logging can be interrupted by pressing F4 gt Ke TI fas Model DL 04 DATA LOGGER Page 9 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 2 Resume Logging If a job has been interrupted for some reason it can be resumed using the Resume Logging process Only the last job in memory can be resumed If there are no jobs
2. 3 To return to the Main Menu select Exit CONFIGURATION MENU Configuration b Set Password 8 Exit Configuration Select more A Model DL 04 DATA LOGGER Page 18 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 1 Set Date The current date can be seen when the DL 04 is turned on It is important that this be set correctly in order to provide accurate log information If the date needs to be changed it is done using the Set Date process from the Configuration Menu 1 From the Configuration Menu select CONFUGIRATION MENU Date 1 Set Date estate 2 Set Time Select 2 Key in the year Use four digits SET DATE Example 1999 ase veges Fut Quit Ca vwx VWX Sey Le CF 1 9 9 ENTER MT PIE J 3 Key in the month 1 to 12 SET DATE Enter month Example 2 Fy Quit 4 Key in the day 1 to 31 SET DATE Example 12 a day Model DL 04 DATA LOGGER Page190f38 Rev 1 70 User Manual Reliable Scale Corporation The new date is displayed before SET DATE returning to the Configuration Menu Date set to 1999 02 12 5 To quit press F4 aC Gu Model DL 04 DATA LOGGER Page 20 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 2 Set Time The current time can be seen when the DL 04 is turned on It is important that this be set correctly in order to provide accurate log information If the time needs to be changed it is done using the Set Time process from
3. 1 From the Configuration Menu select Set Depth Units 2 Key in the depth units Example 1 meters 5 Key in the depth units Example 1 minutes Model DL 04 DATA LOGGER User Manual Page 31 of 38 Configuration MENU 3 Configure Ports 4 Set Depth Units Select more Vv SET UNITS Select Depth Units l meters e2 feet SET UNITS Select Depth Units Depth Units meters SET UNITS Select Time Units l minutes 2 seconds SET UNITS Select Time Units Time Units minutes Rev 1 70 Reliable Scale Corporation 5 5 Plot Delay In order to allow the printer to keep up with the data transfer a time delay is used After each line of the chart has been transferred the DL 04 waits for a specific amount of time This length of time is determined by the Plot Delay setting and is measured in milliseconds 1 From the Configuration Menu select CONFIGURATION MENU Plot Delay 5 Plot Delay b Set Password Select more A 2 The current Plot Delay setting is SET DELAY displayed and the user in prompted for gt ai E gt A 7 aa H the new setting Fut Quit 1100 3 Key in the new Port Delay setting SET DELAY Example 1500mS Current Delay 1100 di New Delay 15008 Fut Quit e ain o gt E CF 1 JUS O ENTER US J D SET DELAY Plot Delay 1500mS 4 To quit press F4 CA CF Model DL 04 DATA LOGGER Page 32 of 38 Rev 1 70 User Manual Reliable Scale
4. 58 00 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Page 37 of 38 Rev 1 70 Reliable Scale Corporation 9 Limited Warranty This warranty applies to all new equipment manufactured by RELIABLE SCALE CORPORATION except when otherwise specified in the Terms of Sale Warranty is subject to the following terms and conditions e All new products are warranted for a period of twelve 12 months from the date of final sale to the end user maximum 24 months from date of manufacture e RELIABLE SCALE CORPORATION shall at its option repair or replace or refund the purchase price within a reasonable period of time after being notified of the alleged defect and after acknowledging that a defect does in fact exist e Warranty claims must be submitted in writing by mail fax or email to RELIABLE SCALE CORPORATION within the warranty period e This warranty does not extend to any consequential damage of other equipment loss of use commercial or economic loss or inconvenience prior to or during the repair period e RELIABLE SCALE CORPORATION is not responsible for any damage or defects caused by misuse negligence neglect modification improper operation improper maintenance or repairs by any unauthorized persons e This is the sole warranty applicable to RELIABLE SCALE CORPORATION S products and no RELIABLE SCALE CORPORATION employee agent or dealer has
5. DC Power Input 4 pin male military style connector P N PT02A8 4P LCD Screen displays instruction and status messages to the operator Alphanumeric Keys operator keys in information Data Control Keys for Entering and Editing data RS 232 Ports 4 pin female military style connectors P N PT02A8 4S to connect devices to the DL 04 Example Digital Scale Personal Computer Line speed indicator Arrow Keys to scroll through menus and stored information Function Keys to issue commands keys are assigned different functions as listed on the LCD screen Power Key to turn the DL 04 on and off Model DL 04 DATA LOGGER Page 4 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 Basic Operation 1 Press the ON OFF key until text appears ON q gt OFF NUE Screen shows the serial number and the RELIABLE SCALE DL O4 DATA LOGGER software version S N 9903148 Version 1 b0 The next screen shows date amp time for RELIABLE SCALE operator verification with local time DL O4 DATA LOGGER P 1999 03 29 14 09 23 zones Fl Continue 2 Press F1 to continue Screen shows the first two options MAIN MENU available from the Main Menu OG ee 2 Resume Logging Select more y 3 Use the UP and DOWN arrow keys to y DECIMAL scroll through all the options T MAIN MENU 3 Delete Data 4 View Data Select MAIN MENU 5 Plot Chart b Print Data Select more A 4 Select the option
6. the Configuration Menu 1 From the Configuration Menu select CONFUGIRATION MENU Time 1 Set Date es E 2 Set Time Select 2 Key in the hour 0 to 23 SET TIME Example 14 ES hour 24 Fus Quit 3 Key in the minute 0 to 59 SET TIME Enter minute ES Example Fut Quit F 2 B een 4 Key in the second 0 to 59 SET TIME Example 50 Enter second Fut Quit MNO ae AJOS Ps J y Model DL 04 DATA LOGGER Page210f88 Rev 1 70 User Manual Reliable Scale Corporation The new time is displayed before SET TIME returning to the Configuration Menu Time set to 14 25 50 5 To quit press F4 aC Gu Model DL 04 DATA LOGGER Page 22 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 3 Configure Ports The ports on the DL 04 can be assigned to different devices to suit individual applications It is recommended however that the default port settings be used They are e Port 1 Computer Printer e Port 2 Counter e Port 3 Weight Indicator 1 From the Configuration Menu select Configure Ports 2 Screen shows first items of the Port Config Menu Use the UP and DOWN arrow keys to scroll through all the options 3 To return to the Configuration Menu select Exit Port Config Model DL 04 DATA LOGGER Page 23 of 38 User Manual CONFIGURATION MENU 2 Set Time 3 Configure Ports Select more A PORT CONFIG MENU 1 Show Port Function 2 Set Port Function Select
7. the DL 0 s memory Records are stored permanently in memory and can only be removed by using the Delete Data option see section 4 3 on page 11 Data transfer can be done as many times as desired before deletion 1 From the Main Menu select Print Data MAIN MENU b Plot Chart 5 Print Data Select more y If there is more than one job in memory PRINT DATA the user will be prompted for the job a TO Print 3 number Bot Oit 2 Enter job number to print 3 During data transfer the number of the _ PRINT DATA entry currently being printed is Printing record 437 displayed UE Model DL 04 DATA LOGGER Page16of38 S Rev 1 70 User Manual Reliable Scale Corporation 4 To quit printing press F4 FA Model DL 04 DATA LOGGER Page 17 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 Configuration Some operating features of the DL 04 can be modified to suit the equipment being used Other parameters such as the date and time need to be set in order to make accurate logs All parameters are set from the Configuration Menu 1 From the Main Menu select _ MAIN MENU Configuration E Pint Data Configuration Select more A ee fe 2 Screen shows first two items of the CONFIGURATION MENU Configuration Menu Use the UP and Set Date e Set Time DOWN arrow keys to scroll through all Select 4 the options more A CONFIGURATION MENU 3 Configure Ports y Set Depth Units Select more A
8. you wish to use ABC Example 1 Log Data CF 1 228 Model DL 04 DATA LOGGER Page 5 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 When an process has been completed MAIN MENU the DL 04 will return to the Main Menu Log Data 2 Resume Logging Select more Y Model DL 04 DATA LOGGER Page 6 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 1 Log Data The chief function of the DL 04 is the Log Data process The screen prompts the operator through the necessary steps issuing instructions as required Once the operator initiates a job each record is saved automatically for future transfer and analysis Once logging has begun the screen is updated every log interval with the latest log information This maintains a record of e Tool Depth with units Line Speed with units Entry Time Line Load with units Entry Number max 113 825 1 From the Main Menu select Log MAIN MENU Data 1 Log Data 2 Resume Logging Operator is prompted for required information starting with Well Name 2 Key in the Well name N Example K14 If letters are used press C7 F2 F2 to enter alpha mode SS Faz Accept alpha The screen will change slightly gt Next position Model DL 04 DATA LOGGER Page 7 of 38 Rev 1 70 User Manual Reliable Scale Corporation 3 Press the number and arrow JKL IKLA keys to scroll through the c gt A 4 enter letters shown at the top of the ie keys
9. Corporation 5 6 Set Password A password is required to delete data from the DL 04 If a password other than the factory default 1234 is desired it can be changed using the Set Password process 1 From the Configuration Menu select Configuration MENU Set Password 3 Configure Ports y Set Password Select more y 2 Key in the old password CHANGE PASSWORD Old Password pal Fus Quit When the password is entered s are displayed for security 4 Key in the new password CHANGE PASSWORD New Password Quit When the password is entered s are displayed for security 5 Key in the new password again to CHANGE PASSWORD confirm it Confirm Password Fus Quit When the password is entered s are displayed for security CHANGE PASSWORD New Password Saved Fus Quit Model DL 04 DATA LOGGER Page 33 of 38 Rev 1 70 User Manual Reliable Scale Corporation 6 To quit press F4 a Gr Model DL 04 DATA LOGGER Page 34 of 38 Rev 1 70 User Manual Reliable Scale Corporation 6 Troubleshooting 1 The DL 04 won t turn on Ensure that the power connector is properly plugged in and is supplying 12VDC Pin A of the power connector is positive pin B is negative 2 When transferring data to the computer nothing happens or else the data looks like garbage Check the cable connections to the computer and make sure the terminal program is properly configured The default is 9600 baud 8 data bits no parity 1
10. Port 1 Function PC 4 To quit press F4 F ed ER Model DL 04 DATA LOGGER Page 25 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 3 3 Set Port Speed Using the Set Port Speed option the port baud rates can be set to accommodate the needs of the device connected to it It is important that this setting is correct for proper device interfacing 1 From the Port Config Menu select Set PORT CONFIG MENU Por 3 Set Port Speed ort Speed 4 Set Port Format Select more A 2 Key in the port to be changed SET PORT SPEED Example 1 Enter port number Fut Quit more A 3 Key in the baud rate SET PORT SPEED Example 3600 Enter port 1 speed i iz Fut Quit more A vwx PQR 0 3 0 N e NN 9 6 ENTER ES Y E O Cee J Model DL 04 DATA LOGGER Page260f8 Rev 1 70 User Manual Reliable Scale Corporation SET PORT FUNCTION Port 1 Speed 9600 baud 4 To quit press F4 a Gr Model DL 04 DATA LOGGER Page 27 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 3 4 Set Port Format Using the Set Port Format option the word length and parity parameters for a port can be set to accommodate the needs of the device connected to it It is important that these settings are correct for proper device interfacing Supported Word Lengths A A 7 1 From the Port Config Menu select PORT CONFIG MENU Show Port Function 3 Set Port Speed y Set Port Form
11. Rev 1 70 Reliable Serial Number Model DL 04 DATA LOGGER WIRELINE DATA LOGGER USER MANUAL 1996 2008 Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road NE Calgary Alberta Canada Tel 1 800 419 1189 403 272 8784 Fax 403 273 9818 E mail info reliablescale com Web http www reliablescale com Reliable Scale Corporation 1 Contents eee 2 8 nE eee rentrertrenrtererennertrenrrt AAAA 2 A actin utah lattes Aa Uitte A Ea ie tte ER 3 2 1 ESAS aia Dee ona ae tee eae a se eet 3 de PNYSiCaNLAVOUN SRE en tu tie ios 4 4 Basic OPIO ui ccc anbe ete Se den nn nn 5 A AA e tae a es EE a a sale N ing A T i 7 4 2 Resume POGGIO eremia tia 10 43 Delle Dia a 11 4 4 View Job Informations ee ida 13 EER a o NA ne RE tete toes ate ee date 14 A yack RSR RER ed A nn ataaugede 16 SE E NET Ae E O OR E re rats 18 Bel SO DS aia on dido 19 qe 0 SEL TIME o 21 5 3 Configure POTTS ect acc li ads 23 O 24 A A e 25 B33 A ts 26 5 34 SOLO FORMAL ie anio 28 5 3 9 Pod Tesista nn etl ee anata 30 Bid Set Dept UNIS a as 31 5 5 A ea detendeienae cel atenaileessag vhs stnaaseviazecela AAAA TENKE EERE onio 32 BiG Set SO sgian E a RE EE EEE R Meu eine 33 62 TROUDICSHOOUING tia 35 Za AMP Na di 36 8 BAM di a at 37 95 imted Wat thet en te heath thet EE 38 Model DL 04 DATA LOGGER Page 2 of 38 Rev 1 70 User Manual Reliable Scale Corporation 2 Capabilities The Model DL 04 DATA LOGGER is a ver
12. anual Reliable Scale Corporation If a valid password has been entered Deleting data the records are deleted and the status is displayed on the screen Data DELETED Model DL 04 DATA LOGGER Page 12 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 4 View Job Information Job information in the DL 04 memory can be viewed on screen without transferring or deleting it 1 From the Main Menu select View Job MAIN MENU Info 3 Delete Data y View Job Info Select more y If there is more than one job in memory VIEW JOBS the user will be prompted for the job oe to View 4 number e uae 2 Enter job number to view 3 The selected job information is VIEW JOBS displayed Use the UP and DOWN arrow 108 3 Job Description keys to scroll through the information r Quit MEN 4 To quit viewing press F4 Model DL 04 DATA LOGGER Page 13 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 5 Plot Chart Data saved in the DL 04 can be transferred to a printer or computer in the form of a chart Line Pull and Depth vs Time Connect the DL 04 to the printer or computer with the proper cables amp hardware Be sure the printer computer is ready to receive the data The default serial port configuration for the DL 04 is 9600 baud 8 data bits no parity 1 stop bit Plotting a job does not remove it from the DL 04 s memory Records are stored permanently in memory and can only be remove
13. any authority to add to this warranty whatsoever e Products for warranty repair must be returned to the factory freight prepaid by the customer RELIABLE SCALE CORPORATION is not liable for any cost related to removal replacement or shipping of the products or any other associated equipment Batteries supplied in or with RELIABLE SCALE CORPORATION products are NOT covered by this warranty Model DL 04 DATA LOGGER Page 38 of 38 Rev 1 70 User Manual
14. at Select more A 2 Key in the port to be changed SET PORT FORMAT Example 1 Enter port number Fut Quit more A 3 Key in the word length SET PORT FORMAT Example amp Enter word length dl E Fut Quit more A Model DL 04 DATA LOGGER Page280f38 Iev 1 70 User Manual Reliable Scale Corporation 4 Choose the parity setting Select Parity es L Even e 0dd Example 5 None 3 Mark 4 Space 5 None ES GP SET PORT FORMAT Port 1 Format 8 N 1 5 To quit press F4 a ire Model DL 04 DATA LOGGER Page 29 of 38 Rev 1 70 User Manual Reliable Scale Corporation 5 3 5 Port Test Proper port operation can be tested using the Test Port Function option in the Port Config Menu This function should not be used when connected to the measurement devices as they can be damaged This can be a useful troubleshooting tool if device communications problems arise and should only by used by trained personnel A test string will be transmitted by each port using its current settings 1 From the Port Config Menu select Port CONFIG MENU Test Test 2 To quit press F4 Model DL 04 DATA LOGGER User Manual Port Config more A ES GP Testing Ports Fut Quit more A Fr Page 30 of 38 Rev 1 70 Reliable Scale Corporation 5 4 Set Depth Units As the Depth Counter does not provide unit information to the DL 04 the user must specify the depth and time units to used for logging
15. d by using the Delete Data option see section 4 3 on page 11 Data transfer can be done as many times as desired before deletion Note The DL 04 has been configured for use with an Epson FX 880 printer with an RS 232 serial interface Other compatible printers should function but proper operation is not guaranteed 1 From the Main Menu select Plot Chart MAIN MENU 5 Plot Chart b Print Data Select If there is more than one job in memory PLOT CHART the user will be prompted for the job Job to Print 3 number a 2 Enter job number to plot 3 During data transfer the number of the PLOT CHART entry currently being plotted is Plotting record displayed dude Model DL 04 DATA LOGGER Paget4of38 Rev 1 70 User Manual Reliable Scale Corporation 4 To quit printing press F4 ie Fa Model DL 04 DATA LOGGER Page 15 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 6 Print Data Data saved in the DL 04 must be transferred to a host computer for historical storage and analysis Connect the DL 04 to the computer with the proper cables amp hardware Be sure your computer is ready to receive the records The default serial port configuration for the DL 04 is 9600 baud 8 data bits no parity 1 stop bit A standard terminal program such as Procomm or HyperTerminal can be used for this procedure see your terminal program manual for details Transferring jobs to computer does not remove them from
16. in memory this process cannot be used 1 From the Main Menu select Resume MAIN MENU Logging 1 Log Data 2 Resume Logging Select more y DEF The operator is asked to confirm the LOGGING 32 resume operation O Me a Confirm Cancel 2 Press F2 to confirm resumption EH F2 3 The DL 04 Resumes logging Resuming Job 3 LOGGING 25b6 4em 122m m 10 23 10 4990kg F4 Quit 000085 4 Logging can be interrupted by pressing F4 C7 F4 So Model DL 04 DATA LOGGER Page 10 of 38 Rev 1 70 User Manual Reliable Scale Corporation 4 3 Delete Data After the records have been plotted see section 4 5 on page 14 or transferred to a computer see section 4 6 on page 16 clear the DL 04 memory using the Delete Records option Jobs should be deleted after each day to make room for new ones and to eliminate confusion 1 From the Main Menu select Delete MAIN MENU Data 2 Resume Logging 3 Delete Data Select The operator is asked to confirm the Confirm Delete data delete operation P Cancel Delete data 2 Press F2 to Delete Records A password is required The factory Enter password default password is 1234 See section 5 4 on page 31 to change password 3 Enter the FRS DEF EN password gt i 2 E MEE ER ae When the password is entered x s are Enter password xx il displayed for security Model DL 04 DATA LOGGER Page 11 of 38 Rev 1 70 User M
17. more A PORT CONFIG MENU 3 Set Port Speed y Set Port Format Select more A CONFIGURATION MENU 5 Port Test b Exit Port Config Select more A gt 6 ES Rev 1 70 Reliable Scale Corporation 5 3 1 Show Port Function The current port assignments can be seen by using the Show Port Function option in the Port Config Menu This can be a useful troubleshooting tool if device communications problems arise 1 From the Port Config Menu select Show Port Function 2 Screen shows first Port Functions Use the UP and DOWN arrow keys to scroll through the list 3 To quit press F4 Model DL 04 DATA LOGGER Page 24 of 38 User Manual PORT CONFIG MENU 1 Show Port Function 2 Set Port Function Select more A PORT FUNCTIONS PC Port 1 Counter Port 2 F Quit more A PORT FUNCTIONS Weight Port 3 Printer Port 1 Fut Quit more A Rev 1 70 Reliable Scale Corporation 5 3 2 Set Port Function The current port assignments can be changed using the Set Port Function option in the Port Config Menu It is recommended that the default port assignments be used 1 From the Port Config Menu select Set PORT CONFIG MENU Port Function l Show Port Function 2 Set Port Function Select more A 2 Key in the port to be changed SET PORT FUNCTION Enter port number id Example Fy Quit 3 Select the function Select Function 2 Printer 1 PC Example 4 Counter SET PORT FUNCTION
18. satile tool designed to record line load line speed and tool depth on Wireline trucks This new technology offers secure data recovery and reduces chances of operator error and improves record keeping The result is an improved profit picture The DL 04 stores data accurately without interfering with the operator s normal activities The DL 04 monitors the truck s digital weight indicator depth meter and line speed meter as often as every 2 seconds and stores the information securely in memory This allows the manager to review very closely the details of each job 2 1 Features Lists job description operator ID job date Each record includes record number line load line speed depth and time of day Stores up to 113 825 records over 63 hours of continuous recording at 2 second log intervals Reads data at 2 second to 99 second intervals Support for 115 200 bps serial transfers XON XOFF flow control for serial transfers Model DL 04 DATA LOGGER Page 3 of 38 Rev 1 70 User Manual Reliable Scale Corporation 3 Physical Layout LCD Screen Backlit Alpha Numeric Data Control 4 Lines by 20 Columns Keys Keys O O O 12 Volt DC z RS 232 Power Input Su DATA LOGGER Ports Record 1 Driver ID 5 JKL PQR Pen Number b 4 6 cor Finish more Y STU TE 66000 SCALE 6 gogoo 000G MODEL DL 04 MADE IN CANADA Power Key Function Keys Arrow Keys 12 Volt
19. stop bit Model DL 04 DATA LOGGER Page 35 of 38 Rev 1 70 User Manual Reliable Scale Corporation 7 Sample Chart The following is a sample chart produced by the DL 04 Reliable Scale Corporation DL 04 Wireline Data Logger Log Reoprt Report Date 1999 10 22 Job 4 Start Entry 50 Well Name TEST WELL Well Number 452 Wireline Job Type TEST Job Operator JOHN SMITTH Job Date 1999 10 22 Start Time 08 23 35 End Time 08 25 33 Log Interval 2s entries plotted Model DL 04 DATA LOGGER Page 36 of 38 Rev 1 70 User Manual Reliable Scale Corporation 8 Sample Log The following is a sample log gathered by the DL 04 Each column has a fixed number of characters and is separated by a comma The columns are organized as follows DER Log entry Memory location Log time Line Load Line depth Line speed Job 1 Job Date 1999 02 25 2s Log Interval Start Entry Job Description Job Operator D D 1 2 3 4 5 6 gt 8 9 10 11 12 13 14 15 16 17 18 19 L J010H4s N RO 0 J0dD4 NR NNN NH sos N Ww NN U eA O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 O1 ow ooo W BILL 28 228 28 228 28 28 28 29 20 LOS n29 29 29 20 208 20 29 129 2 08 20 SHE LO 20 2 0 220 20e PACE s29 28 records printed Model DL 04 DATA LOGGER User Manual ELLO1 46 48 50 SAR 54 56