Regency P121/P131-LP2 User's Manual

image

Contents

1. P121 P131 Gas Fireplace Rigid Pipe Venting Horizontal or Vertical Terminations Vertical Terminal O 2 Storm Collar Part 953 Vinyl Siding Standoff Optional Flashing Part 950 943 or 943S w Ceiling 963 lt gt Part 963 Horizontal Termination Cap Part 946 523 P me Thimble Part 942 Required in Pipe Length lt Sin Pipe Length Canada 90 Elbow Pipe Length L 45 Elbow Rigid Pipe Adapter Part 510 994 Alternate Horizontal Termination Caps Alternate Snorkel Termination Cap Part 982 14 Part 981 36 Alternate Horizontal Riser Vent Terminal Part 640 530 P Venting Arrangements Vertical Terminations Rigid Pipe System Propane amp Natural Gas The P121 131 is approved for a maximum 35 ft straight vertical with Rigid Pipe vent systems for Propane and Natural Gas Vent must be supported at offsets Horizontal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between elbows Note Must use optional flue adapter when using Rigid Pipe Part 510 994 Maximum 35 10 7m Minimum 6 6 2 0m b J Rigid Pipe Adapter Part 510 994 b 72 Vertical Venting with One 1 90 Elbow Two 45 elbows One 90 elbow Maxi
2. REGENCY P121 P131 Gas Fireplace Framing and Finishing 1 Determine the total thickness of facing material e g drywall plus ceramic tiles to allow the finished surface to be flush with the front of the unit Total facing thickness can vary from 1 2 13mm to 1 74 32mm thick 2 Frame in the enclosure for the unit with framing material 3 For exterior walls insulate the enclosure to the same degree as the rest of the house apply vapor barrier and drywall as per local installation codes Do not insulate the fireplace itself 4 The top of the unit must not be closer than 36 990mm to the ceiling 5 Combustible material may be brought up to the top and sides of the unit and be covered with ceramic tiles bricks rock or other suitable combustible finishing materials Note The unit does not have to be completely enclosed in a chase The clearance on top of the unit is 0 to the standoffs so combustible building materials can be laid directly on top of the standoffs You must maintain proper clearances from the vent to combustible materials See Below 6 Use metal studs for framing where the minimum clearance from the vent to combustible material cannot be maintained Clearance Requirements Clearance Dimension _ Measured From A Mantel Height 3 76mm Minimum Additional on this page B Sidewall 0 Omm 3 76mm Side of installed front On P121 2 See Thru 3 clearance opposite vent
3. C Ceiling D Mantel Depth E Alcove Width F Alcove Depth 36 914mm 12 305mm Top of installed unit Maximum Additional on this page See Parallel Wall Clearances 36 914mm Front to back wall Maximum Top of Hearth must not be higher than the base of the firebox 70 Gas Fireplaces Parallel Wall Clearances Unless otherwise stated the clearances listed below are Minimum distances to combustible materials Unit pictured is a P131 Parallel Wall Clearances P121 LC RC 131 Min distance from glass to a parallel wall 36 914mm 1 1 Vent Clearances Clearance Dimension Horizontal Top 2 1 2 64mm 1 1 2 38mm 1 1 2 38mm 1 1 4 32mm WARNING Failure to maintain required clearances is a major cause of Horizontal Side Horizontal Bottom Vertical chimney related fires Installation of this fireplace must comply with these clearances Combustible Mantels Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of the louvers are shown in the diagram below Mantel may be installed anywhere in the shaded area or higher Mantel Clearances 12 10 8 6 4 2 0 E ere Drywall A 4 Header Note Ifthefireplaceisinstalled Sie without the 3 Extension Trim 4 B 3 89mm the facing material must be 2 non co
4. Part 946 578 P 6 7 8 173mm Ka dia Flue pS spring spacer Alternate Horizontal Termination Caps Alternate Snorkel Termination Cap Part 982 14 Part 981 36 Alternate Horizontal Riser Vent Terminal Part 640 530 P June 2007 Regency Product Specifications Book P121 P131 Gas Fireplace Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise on the exterior of the building 14 inch and 36 inch tall Snorkel Terminations and the Riser Vent are available Follow the same installation procedures as used for standard Horizontal Termination NEVER install the snorkel upside down Riser Vent Termination I ll i L Dura Vent jo jj E Snorkel Min 12 305mm Below Grade Snorkel Installation Dura Vent Only If the Snorkel Termination must be installed below grade i e basement application proper drainage must be provided to prevent water from entering the Snorkel Termination Refer to Rigid Pipe Installation instructions for details Do not attempt to enclose the Snorkel within the wall or any other type of enclosure 7 i Dura Vent Snorkel Min 12 305mm ae Adequate 5 drainage 71 Q 9 7 T o oc D 0 r o n Q S S 2 Q i n Oo REGENCY Gas Fireplaces
5. 4 3 4 121mm 3 76mm If the provided 3 extension trim is not installed the P121 LC RC P131 must be installed with non combustible facing up to 8 above the fireplace Otherwise combustible facing may be used above the extension tri m Please refer to Page 11 Exterior Vent Terminations for additional guidelines on vent locations June 2007 Regency Product Specifications Book E E E nN OE S ED E TEE Lo SSE N E EN EEP EE HE E EHE O SSse Ne tl t ee aIOS W111 1114 Framing Width t Framing Heigh h Framing Dept Vent Centerline Height Framed Chase Ceiling Electrical Inlet Height Electrical Inlet Inset Gas Connection Height Gas Connection Inset lt 4 Top of Non Combustibl s on Combustible Unit Material Cor ae istible aterial 46 3 4 1187mm cee e 42 112 42 1 2 42 4 2 1080mm 1080mm 1080mm 26 13 16 681mm 25 635mm 25 635mm 42 13 16 1072mm 48 1 4 1226mm 2 51mm 2 51mm 2 51mm 11 3 8 13 5 16 11 3 8 289mm 338mm 289mm 1 11 16 43mm 1 11 16 snarl 1 5 8 41mm 11 1 2 11 1 2 11 1 2 292mm 292mm 292mm Refer to the manual for variations effected by finishing material thickness 69 N O O c Q O i m oO
6. with Two 2 90 Horizontal Venting with Three 3 90 Elbows Initial vertical section Elbows Initial vertical section Two 45 elbows One 90 elbow Two 45 elbows One 90 elbow Maximum total pipe length of Maximum total pipe length all sections must not exceed ee of all sections must not 37 feet i i exceed 37 feet Total horizontal sections must Min i l Total horizontal sections not exceed 15 feet ey must not exceed 12 feet Minimum of 1 foot between Minimum of 1 foot between 90 elbows is required Min 90 elbows is required Q D o T 0 5 D 0 f N Horizontal Venting with Three 3 90 Elbows Initial horizontal section Two 45 elbows One 90 elbow V H H1 H2 Maximum total pipe length of Option H v H H1 Maximum total pipe length of enter all sections must not exceed aaa all sections must not exceed 37 feet 37 feet Total horizontal sections must not exceed 12 feet F T Minimum of 1 foot between adaa laa Horizontal Venting with Two 2 90 Elbows Initial horizontal section Two 45 elbows One 90 elbow June 2007 Regency Product Specifications Book 75
7. Gas Fireplaces REGENCY P121 P131 Gas Fireplace P121 P121LC RC P131 Zero Clearance Direct Vent Jas Fireplace Moder _Pizvpistne2 Pizia 40 000 BTU h 11 72 kW 39 000 BTU h 11 43 kW 4 Inner 6 5 8 Outer 4 Inner 6 5 8 Outer Approved Venting Systems Flex Vent Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Dura Vent Direct Vent GS American Metal Products Ameri Vent Security Secure Vent Selkirk Direct Temp Q 9 7 T o oc 9 0 r o Maximum Input Vent Sizing r i P121 See Thru P131 Pier T mM Th l i m m Greyed out framing will not apply to all units 4 I eo Please refer to the manual Electrical BACK Gas Line L J c Li Inlet Inlet P121RC Right Corner P121LC Left Corner Sigs B J ai I SS KI ru SS H 43 1 2 Front Face Width 1105mm 46 1 4 Total Firebox Width 1175mm Front Face Height 36 914mm Height w Standoff Unit Depth 25 635mm 21 1 8 Top Offset Depth 537mm 4 3 4 Inset to Standoff 121mm 42 1067mm 41 1 2 41 1 2 1054mm 1054mm 44 112 44 112 1130mm 1130mm 36 914mm 36 914mm 42 1067mm 42 1067mm 26 13 16 681mm 25 635mm 21 1 8 21 1 8 537mm 537mm
8. ctions must not ae exceed 12 feet Minimum of 1 foot between 90 D elbows is required Vertical Venting with Three 3 90 Elbows Initial horizontal section Two 45 elbows One 90 elbow all sections must not exceed Total horizontal sections must ani Minimum of 1 foot between 90 73 Q D o T 5 D 0 f N N O O c Q O i n oO REGENCY P121 P131 Gas Fireplace Venting Arrangements Horizontal Terminations This diagram shows allowable venting configurations using one 45 Note Must use optional flue adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Avent guard should be used whenever the termination is lower than the specified minimum or as per local codes Note FPI Direct Vent System Flex is only approved for horizontal terminations 74 Gas Fireplaces Horizontal Venting with One 1 90 Elbow Two 45 elbows One 90 elbow Maximum total pipe length of all sections must not exceed Total horizontal sections must not exceed 17 feet Minimum of 1 foot between 90 elbows is required June 2007 Regency Product Specifications Book Gas Fireplaces REGENCY P121 P131 Gas Fireplace Horizontal Venting
9. mbustible up to 8 _ I E extension Th above the unit 4 Cr 0 y A 3 A Unt to i a am Side View Mantel Clearances A BL otm rorem een Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour June 2007 Regency Product Specifications Book Gas Fireplaces REGENCY Regency Direct Vent System Flex Horizontal Terminations Only These venting systems in combination with the P121 P131 Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram FPI Direct Vent Flex System Termination Kits include all the parts needed to install the P42 using a flexible vent 946 513 2 Feet 6 5 8 flexible liner Kit length 4 flexible liner Kit length spring spacers 3 946 515 946 516 10 Feet thimble 2 Notes AstroCap termination cap 1 1 Liner sections should be continuous without any joints or seams screws 12 tube of Mill Pac 1 2 Only Flex pipe purchased from Regency may be used for Flex installations plated screws 8 3 Horizontal sections must be supported every 3 feet S S screws 8 x 1 1 2 drill point 4 Wall Thimble required in Canada only l ze OP N ae Termination Cap
10. mum total pipe length of all sections must not exceed 37 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required IMPORTANT When installing this unit vertically the 45 elbow when installed in conjunction with the Rigid Pipe Adapter will protrude past the unit 1 72 38mm when measured from the rear standoffs Note A 1 32mm clearance from the elbow must also be maintained 45 Elbow Rigid Pipe Adapter June 2007 Regency Product Specifications Book Gas Fireplaces Vertical Venting with Two 2 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Maximum total pipe length of all sections must not exceed 37 feet Total horizontal sections must not exceed 17 feet Minimum of 1 foot between 90 elbows is required Vertical Venting with Two 2 90 Elbows Initial horizontal section Two 45 elbows One 90 elbow Maximum total pipe length of all sections must not exceed Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required June 2007 Regency Product Specifications Book REGENCY P121 P131 Gas Fireplace Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option vevi H H1 Maximum total pipe length of oad all sections must not exceed 37 feet Total horizontal se

Download Pdf Manuals

image

Related Search

Related Contents

Rocketfish QS2-T User's Manual  SELFSAT OUTDOOR J05TK 取扱説明書  その他の情報 - macincash.net  Description du module EE4.4_Bâtiment intelligent  Manuel d`utilisation et de sécurité de la presse de jonction  Sony MDS-JA333ES User's Manual  Philips Dock for iPod/iPhone DCK3060    Fujitsu LIFEBOOK T730  Eglo SOLAR  