1. Front to back wall Maximum Clearance Requirements Regency Liberty L900 Gas Fireplace IMPORTANT NOTE Combustible material can only be installed to the bottom lip of the replace as shown below The nished oor must not come in contact with the front face of the replace Non combustible material must act as a barrier between the front face and nished oor Vertical Terminations Finished Floor The maximum height that combustible oor can be brought above the base of the unit is 3 Drywall Mantel Clearances 2 0 12 6 4 8 10 Top of Fireplace Opening 13 330mm 3 89mm A Standoff B C Header On Edge 0 10 15 20 25 14 Non combustible Facing To Floor D 1 25mm Combustible Mantels Because of the extreme heat this replace emits the mantel clearances are critical Combustible mantel clearances from top of the louvers are shown in the diagram below Mantel may be installed anywhere in the shaded area or higher Mantel Clearances From Top of Fireplace Opening A 35 1 16 B 27 1 2 C 18 1 2 D 17 1 2 Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non com bustible board Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Mantel Leg Clearances Combustible mantel
2. 2 673mm M Minimum Height to Combustibles 60 1524mm N Corner Wall Length 63 15 16 1624mm O Corner Facing Wall Width 90 7 16 2286mm P Vent Centerline Height 53 1346mm Q Non combustible facing height 17 7 16 443mm R Gas Connection Opening Height 2 51mm S Gas Connection Height 11 1 4 286mm T Gas Connection Inset 6 152mm U Gas Connection Opening Width 5 127mm Important Framing height requires consideration of the hearth depth Dimension K K the thickness of installed hearth WARNING Failure to maintain required clearances is a major cause of chimney related res Installation of this replace must comply with these clearances Please note Due to ongoing product development product appearance and speci cations are subject to change without notice This manual is intended to be a Sales Reference Guide only Do NOT use for actual framing and installation of any unit Some speci cations may change without notice You must use the actual manual for exact installation speci cations L900 1 Gas Fireplace Clearance Dimension Measured From A Mantel Height 17 1 2 445mm Minimum B Sidewall 15 3 4 400mm Side of replace opening C Ceiling 49 1245mm Top of replace opening D Mantel Depth 13 330mm Maximum E Alcove Width 84 2134mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm
3. leg clearances as per diagram Clearances are from the nished edge of the replace opening Horizontal Terminations
4. Model L900 NG1 L900 LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W C 1 25 kPa 12 W C 3 00 kPa Manifold Pressure High 3 5 W C 0 87 kPa 10 W C 2 49 kPa Manifold Pressure Low 1 6 W C 0 40 kPa 6 4 W C 1 59 kPa Ori ce Size 30 DMS 49 DMS Minimum Input Altitude 0 4500 ft 0 1372m 28 000 BTU h 8 20 kW 31 000 BTU h 9 08 kW Maximum Input Altitude 0 4500 ft 0 1372m 41 500 BTU h 12 16 kW 38 500 BTU h 11 28 kW Vent Sizing 5 Inner 8 Outer 5 Inner 8 Outer Unit Dimensions Description L900 1 A Firebox Width w Standoff 51 1 2 1308mm B Rear Firebox Width 40 5 8 1032mm C Firebox Height 41 3 8 1051mm D Height w Standoff 50 3 8 1270mm E Unit Depth 27 686mm F Height to Vent 44 1 2 1130mm G Fireplace Opening Height 32 1 16 814mm H Fireplace Opening Width 33 5 8 853mm I Height to Fireplace Opening 3 76mm L900 1 Gas Fireplace Approved Venting Systems Flex Vent Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Direct Vent Pro Selkirk Direct Temp Metal Fab Sure Seal Regency Liberty L900 Gas Fireplace Unit Dimensions Framing Dimensions Non Combustible Requirements Framing Dimensions Description L900 1 J Framing Width 52 1321mm K Framing Height 50 3 4 1289mm Hearth L Framing Depth 26 1

Download Pdf Manuals

image

Related Search

Related Contents

AEG X66453BV0 cooker hood  Snapper HD4686 User's Manual  Sony VAIO VPCEA3MGX/BJ notebook  0059157 - 4535 Smaragd DE_EN_FR  情 熱 を 燃 や し 、挑 戦 を 続 け る 。    Indesit KM B21S(X)/EX cooker  lanKocast 262  User Manual - CCTVDISCOVER  EVBUM2328 - NCV7681AGEVB Evaluation Board User`s Manual  

Copyright © All rights reserved.
Failed to retrieve file