Home
Raypak 992B-1532B User's Manual
Contents
1. Job Engineer Contractor Prepared By Model Sealed Combustion Chamber 100 Factory Fire Tested Efficiency 85 Minimum Non condensing Inlet Temperature 105 F Thermal Shock Proof Heat Exchanger Limited Twenty year Thermal Shock Warranty Limited Five year Heat Exchanger Warranty Diagnostic Center with Fault History PolyTuf Powder Coated Cabinet No Combustible Floor Shield Required Fan assisted Non ferrous Bypass Patented Burner Security Blanket Heat Exchanger Bronze Headers ASME Inspected and Stamped 160 PSIG Working Pressure National Board Approved Cupro Nickel Finned Tubing ASME Steel Tube Sheet Silicone High Temp O Rings 125 PSIG ASME Pressure Relief Valve Temperature and Pressure Gauge Water Connections O Left Standard L Right Option A 6 Bronze Pump 1 2 HP 120V 60Hz Non ferrous Pool Bypass Controls 120V 60Hz 1 Power Supply 120 24V 60Hz Transformer 100 Shut off Lockout Hot Surface Ignition System Remote Flame Sensor High Limit Control Auto Reset On Off Power Switch Manual Shut off Front mounted Flow Switch Blocked Vent Pressure Switch Combustion Air Proving Switches Economaster Pump Time Delay Poolstat Catalog No 6000 332B Effective 8 15 08 Date Indoor Outdoor Gas Train Gas Pressure Regulators Safety Shut off Valves Firing Control Valves On Off Firing Low Gas Pressure Switch Manual Fuel LI Natural Gas LI Propane Gas Design Certified A
2. NSI Z21 56 CSA 4 7 Burner Ultra low NOx Less than 30 PPM Construction Indoor Outdoor Construction Enclosed Front Controls Venting Vent Location LI Top Standard LI Rear Option D 14 Vent Termination Cap L Outdoor Option D 11 L Indoor Horizontal Option D 15 L Indoor Vertical by others Combustion Air O In Line Filter Kit TruSeal only Option D 17 CZ Air Intake Elbow Option D 16 Replaces 3 1 07 Hi Delta Type P Commercial Pool Heaters Models 992B 1532B MBTUH Input Options O c 6 CL D 21 O F 10 O 1 5 O s 2 O x 1 O x 2 O Y 241 Ignition Module Manual Reset TruSeal Direct Vent O Left Side Standard L Right Side Optional Low Water Cut off Remote Probe High Limit Control Manual Reset High Gas Pressure Switch Manual Dual switches on Model 1532B SureRack Kit Zone IIl and IV SureRack Add on Zone IV Temperature Controller 1 4 Stages Regulatory Agency Requirements CSD 1 O G 1 Hi Delta Type P Models 992B 1532B Model OPTIONAL OUTDOOR 10 5 8 VENT CAP OPTIONAL OUTDOOR CONTROL PANEL OPTIONAL FLUE LOCATION POVE STON AIR WITH FIELD CONVERSION KIT BYPASS Nn PRV 4 1 4 REAR MTD PUMP ACCESS PANEL FRONT VIEW BACK VIEW 2 1 2 NPT WATER INLET 2 1 2 NPT WATER OUTLET T COMBUSTION AIR INLET 2NPT GAS CONNECTION 7 8 ELECTRICAL CONNECTION VIEW P
3. ORT LEFT SIDE RIGHT SIDE K FLUE OUTLET OPTIONAL PUMP COVER RATE OF FLOW AND PRESSURE DROP Max Flow Min Flow 1262B 132 15 5 16 71 4 5 30 1532B 132 16 5 20 87 7 2 30 TOP VIEW Hel 992B 132 14 0 13 56 2 5 30 T Amp Draw Shipping Input Output w Pump Weight Lbs A ane 500 Dimensions are in inches Ratings shown are for elevations up to 5 000 feet and for natural or propane gas For installation at elevations over 5 000 feet please contact manufacturer Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 800 872 9725 www raypak com Catalog No 6000 332B Effective 8 15 08 Replaces 3 1 07
Download Pdf Manuals
Related Search
Related Contents
SCP1000 DEMO KIT User Manual Sterling SSC1-5Q Marine Battery User Manual König KN-TRIPOD9 tripod Benutzerhandbuch zur Hardware des Liquivision X1 Lx \ Ls Series User Manual Louer un logement : ce qui change le 1er août 2015 (PDF UM10198 - eecosales.com Copyright © All rights reserved.
Failed to retrieve file