1. Quantum Scalar i6000 i Release Notes Product Scalar i6000 Firmware Version i12 2 2 Firmware Version Operating Systems Standalone LMC Client 710Q GS11200 Microsoft Windows Ubuntu x86 ia64 Red Hat Linux x86 ia64 Supported Web Browsers Firefox Java GUI Internet Explorer versions 7 and higher Supported Web Browsers Firefox WebGUI Chrome Required Java Runtime Environment JRE JRE version 6 and higher Date June 2015 Contents Purpose of This Release 2 0 00 2 New Features and Enhancements 0000 cece eee tees 2 General Information 0 000 e KARANAA 2 Security Scanners 2 0 0 tae 3 Compatibility and Support 0 aaaea a 3 Resolved Issues 0 0 ae 5 KNOWN ISSUES gt piec ee eee ete ese eae dee Lea ee Cea eben new e OS 5 Documentation 0 0 0 0 00 ae 8 Contacting Quantum 0 6 ee 9 6 66883 41 Rev A June 2015 Quantum the Quantum logo DLT DLTtape the DLTtape logo SuperLoader Scalar StorNext and DXi are registered trademarks of Quantum Corporation registered in the U S and other countries All other trademarks are the property of their respective companies Specifications are subject to change without notice 2015 Quantum Corporation All rights reserved Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Purpose of This Release The Scalar i6K i12 2 2 release details bug fixes described in the R
2. can hang if you wait too timely manner If you do wait too long to respond to dialog prompts long reboot the library 55202 When upgrading from i11 x to i12 x all Before the upgrade note which ticket suppression filters will not be filters you have set and then reset restored Restoring a configuration back to them after the upgrade is complete i11 3 will also not restore the filters 55216 In libraries larger than 8 frames Reboot the library a geo addressing issue may cause diagnostic tickets related to CMBs and HDCs to be generated in error 55492 When upgrading from i11 3 toi12 2 1 the 1 Go to Setup gt SNW Wizard partition is not mapped or listed in the 2 Click Next Bicces gt Group Configuratio 3 Select Host Access radio button 4 Click Next 5 Select Host Access Configuration 6 Click Next 7 Select Group 8 Expand Tree Known Issues Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Change Service Request Request Description Workaround Number Number 52434 3382082 If a open door is detected the library may Check to ensure that all doors are 3399088 report the wrong door as open closed properly e Check the lance small metal piece in door lock to see if it is damaged Repair if possible and close door 54884 3522766 During a library snapshot the HDC may go Reboot the library offline 52884 The following Nessus scan result may be An i6000 librar
3. 00 Drive Types Firmware Version IBM LTO 1 SCSI 5AU1 IBM LTO 1 FC 5AU1 IBM LTO 2 SCSI A4NO IBM LTO 2 FC A4NO IBM LTO 3 FC 2 Gb 93GM IBM LTO 3 FC 4 Gb 93GM IBM LTO 4 FC 4 Gb C7QH IBM LTO 5 FC 8 Gb E6Q6 IBM LTO 6 FC 8 Gb E6R6 HP LTO 3 FC 2 Gb L67Z HP LTO 3 FC 4 Gb M69Z HP LTO 4 FC 4 Gb H64Z HP LTO 5 FC 8 Gb I6GZ HP LTO 6 FC 8 Gb J55Z 1 For information about installing the LMC remote client contact Quantum Support 2 Check with Quantum Support for the latest firmware 3 Logical serial number addressing drive spoofing is not supported Backup Software To view a list of backup software packages that have been tested for Compatibility interoperability with the Scalar i6000 refer to the Quantum Software Compatibility Guide at http www quantum com swcompguide aspx D Compatibility and Support Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Resolved Issues This release of Scalar i6000 firmware resolved the following issues Change Service Request Request Number Number Description Resolution 56096 3534826 An external application passing a value of Fixed O will cause internal library communications between the RCU and MGB to fail 56104 After enabling IPv6 and DHCPIPv6 on the Fixed library a reboot would fail to get a DHCP IP address 56007 Using the stateless auto configuration IPv6 Fixed may not allow a connection to the library
4. esolved Issues section Visit http Awww guantum com for additional information about the Scalar i6000 and prior releases New Features and Enhancements This release contains no new features or enhancements General Information e The standalone LMC client is not provided by default Contact Quantum Service for details e JRE is not required with the standalone LMC client e If media is encrypted on an IBM drive using Library Managed Encryption LME the library will initially report the media as being unencrypted when it is actually encrypted The encryption status of the media will be properly reported once the media is re mounted in the drive e To help maintain system integrity and for marketing purposes Quantum regularly collects system information through automatic emails These emails contain configuration and status information only and do not contain any customer data stored on the system To disable this function 1 Log on to your library 2 Go to Setup gt System Setting gt Physical Library 3 In the Send Usage Statistics area select the Disable radio button 4 Click OK e The Web client places a cookie on the user s computer to provide the last user s credentials upon login The cookie only collects the user s credentials to facilitate login and does not collect any other user data N Purpose of This Release Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Security Scanne
5. leshoot 50514 1647282 MICA should only inform of multi initiator If multi initiator operation without 50591 1647440 conflicts not just multi initiator operation reservations is being reported you without reservations can filter the diagnostic tickets From the GUI configure the library to enable diagnostic ticket filtering Setup gt Notifications gt Tickets Filter 53329 EEB attached IBM LTO 5 and LTO 6 drives Reboot each drive individually If that upgraded to latest drive firmware may doesn t fix the issue reboot the come up in the library in passive mode library 51994 When a drive sled is added to a partition it Make sure that the robot s is may not appear in RES data enabled and initialized before physically adding the drive to the library 54091 During a backup if the drive loses both FC To get the media to return to home connections failover will occur but the slot from Net back Up NBU media will not be moved to home slot Select Devices gt Robot Right click Select Change Browse to select robot device Click OK Click OK Click OK Media is then put in it s home slot 51702 During IVT data pertaining to the drive Make sure that the calibration targets side magazines in the right parking are located in the correct column and module is not included in the report row If calibration targets cannot be in their proper position because of drive location you can move the drives to diffe
6. m com support Contacting Quantum 9 Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 10 Contacting Quantum
7. rent positions in the drive sled Known Issues Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Change Service Request Request Description Workaround Number Number 54202 If you disconnect the cable from a control 1 Update path to robot path drive that is connect to a host HBA 2 run library audit the library will lose connectivity to the checklabel barcode robot 3 Media will now return to its home slot 4 Users are now able to run simultaneous backups to both drives without repairing FC connection on Host HBA 54220 If the control path drive fails over during 1 Run checkin libvolume search yes an import any media in the picker will not to pickup missing media be discovered 2 Then rerun the checkin libvolume search bulk to import remaining media in I E 54580 A Series 3 control module may show the There is no negative effect to library presence of two CMBs even though there functionality The second CMB listed is only one is actually the MCB 54630 3948014 If the email addresses in the Contact tab Check of the Notifications dialog and the Email setup gt Notifications gt System Notifications dialog are the same an Setup Email Address field and email will bounce ie undeliverable and i i fail to be delivered Setup gt Email Configuration l Sender Address field 54852 During a change to the internal IP of the Respond to the dialog prompts in a library the GUI
8. rs Quantum runs the following Security scanners against the library e BeyondTrust Retina Network Security Scanner version 5 18 3 2656 e No critical issues were reported Compatibility and Support Encryption Key Management Drive Support HP IBM HP IBM HP IBM Encryption Option LTO 4 LTO 4 LTO 5 LTO 5 LTO 6 LTO 6 Application Managed Supported Supported Supported Supported Supported Supported Encryption Q EKM Not Requires Not Requires Not Requires Supported EKM Supported EKM Supported EKM License License License SKM Requires Not Requires Requires Requires Requires EKM Supported EKM EKM EKM EKM License License License License License KMIP Key Manager Requires Not Requires Requires Requires Requires EKM Supported EKM EKM EKM EKM License License License License License 1 Only SafeNet and Thales encryption key servers are supported KMIP configurations Security Scanners 3 Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Firmware Compatibility The following table shows information on drive and auxiliary firmware Matrix compatibility with this release of Scalar i6000 This information is current as of this product release For the most up to date information on the latest qualified firmware please visit http Awww guantum com Release i12 2 2 Library Firmware 710Q GS11200 Library Management Console LMC Remote Client 710G GH106
9. s LMC even with IPv6 enabled Known Issues This release of i6000 i12 2 2 firmware has the following known issues Change Service Request Request Description Workaround Number Number 42325 If a SafeNet key server s in a cluster is not Users need to sync the key server reachable during normal key requests cluster manually encryption keys issued by other key servers in the cluster will not automatically replicate to the unreachable server s afterwards 43012 When the library has an issue importing Verify that communication to the key encryption keys an error message server is operational perform Path erroneously informs users that there was a Diagnostics communication issue with the key server If communication with the key server is not impacted the issue is that the keys cannot be imported due to being wrapped with a certificate public key that does not match the server s private key Resolved Issues 5 Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Change Service Request Request Description Workaround Number Number 43149 In some instances during a drive firmware The drive should come back online update and associated drive reboot a after the firmware update is diagnostic ticket reporting the drive has complete and the diagnostic ticket been removed may be generated will auto close If not follow the directions on the diagnostic ticket to troub
10. y does not use generated Apache This is a false positive Nessus was unable to crash the web server so this might be a false positive Documentation The following documents are currently available for the Scalar i6000 Document Number Document Title 6 66879 xx Scalar i6000 User s Guide 6 66882 xx Scalar i6000 Planning Guide 6 01847 xx Quantum Encryption Key Manager User s Guide 6 01884 xx Quantum Encryption Key Manager Release Notes 6 66532 xx Scalar Key Manager Quick Start Guide 6 66531 xx Scalar Key Manager User s Guide 6 66572 xx Scalar Key Manager Safety Information by IBM 6 66535 xx Scalar Key Manager Open Source License Agreement 8 Documentation Quantum Scalar i6000 Release Notes 6 66883 41 RevA June 2015 Contacting Quantum More information about this product is available on the Service and Support website at www quantum com support The Service and Support Website contains a collection of information including answers to frequently asked questions FAQs You can also access software firmware and drivers through this site For further assistance or if training is desired contact Quantum Quantum Technical Assistance 1 800 284 5101 Center in the USA For additional contact information Www guantum com support To open a Service Request www quantum com osr For the most updated information on Quantum Global Services please visit www quantu

Download Pdf Manuals

image

Related Search

Related Contents

User Manual – UCG Solar 5KVA Inverter  TSM la gamme metrolo..  roscoe medical mini compressor nebulizer  CDI 2120 (41902179)  IR104 Relay / Optoisolator PC/104 Board User Manual  SpongeBob Redemption Version  sezione 1 − precauzioni di sicurezza − leggere prima dell`uso  第6号 - 横浜市  Audiovox 09XR1PR Satellite Radio User Manual    