1.         Quantum Scalar i6000    Release Notes                   Product Scalar   i6000  Version i8 4  Firmware Version 617Q GS01001   Operating Systems Microsoft    Windows     Remote LMC Client  Solaris       Red Hat   Linux       Supported Web Browsers Firefox    Internet Explorer versions 6  7  and 8  This  release is the last release that supports IE 6        Required Java Runtime JRE version 6  Environment  JRE                 Date February 2012  Contents  Purpose of This Release    0 0    00 eee 2  New Features and Enhancements             0000 ccc cece ee eee eens 2  Compatibility and Support    sssaaa aaeeea 2  Resolved Issu s 2    ee eee ee ee ens 4  KNOWN ISSUCS  24 0424 45409 eMedia Ra Ne ad da bh b4 24844 te 5  DOCUMENTATION    wanenueenwewek beeen ec ages bec kbh Geese ee eu eee E 9  Contacting Quantum       0 0    ee 9     2012 Quantum Corporation  All rights reserved  6 66883 12 Rev A  February 2012    Quantum  the Quantum logo  DLT  DLTtape  the DLTtape logo  SuperLoader  Scalar  StorNext  and DXi are registered  trademarks of Quantum Corporation  registered in the U S  and other countries  All other trademarks are the property of their  respective companies  Specifications are subject to change without notice     Quantum Scalar i6000 Release Notes  6 66883 12 RevA  February 2012       Purpose of This Release    This release supports the replacement of end of life barcode scanner E1022 with  the new EV12 scanner  This is described in Resolved Issues on page 4 
2.        New Features and Enhancements    No new features  New code to support the new EV12 scanner        Compatibility and Support       Encryption Key                        Encryption  n ment Dr  Management Prive Option HPLTO 4   IBM LTO 4   HPLTO 5   IBM LTO 5  Support  Application Supported Supported Supported Supported  Managed  i6000 only     i6000 only   Encryption  Q EKM Not Requires Not Requires  Supported EKM License   Supported EKM License  SKM Requires Not Requires Not  EKM License   Supported EKM License   Supported  RKM Requires Not Requires Not  EKM Supported EKM License   Supported  License    N                   Purpose of This Release    Quantum Scalar i6000 Release Notes  6 66883 12 RevA  February 2012    Firmware Compatibility See the following table for information on drive and auxiliary firmware  Matrix compatibility with this release of Scalar i6000  This information is current as of       this product release  For the most up to date information on the latest qualified    firmware  please visit  http   www quantum com           Release  i8 4    Library Firmware  617Q GS01001  Library Management Console  LMC  Remote Client  5 3 3 Build 48                                                     Drive Types Firmware Version   Quantum SDLT 320  SCSI  v1002  Quantum SDLT 600  FC  v553  Quantum DLT S4 v42  IBM LTO 1  SCSI  5AU1  IBM LTO 1  FC  5AU1  IBM LTO 2  SCSI  A4NO  IBM LTO 2  FC  A4NO  IBM LTO 3  FC  2 Gb 93GM  IBM LTO 3  FC  4 Gb 93GM  IBM LTO 4  FC  4 G
3.  not have them   Expansion blades are installed in the  installed  Ethernet connections were not library  the following rules regarding  made between the MCB and the newly control management blades  CMBs   installed I O blades  apply    e Any module  including the control  module  that contains FC I O  blades or EE blades must also  contain a CMB    e A CMB must be installed in the  control module and all modules  between the control module and  the module containing the FC I O  blade or EE blade  The CMB  provides daisy chained Ethernet  communication between the  Management Control Blade  MCB   located in the control module and  the FC I O blades and EEBs    34370 Ticket reports sent directly from library via   Log in from the remote interface and  e mail contain no data  Tools  gt  Reports  gt    download the file  Tools  gt  Reports  Tickets  then select Export  gt  Email    gt  Tickets  then select Export  gt   Viewed and saved reports contain data as   Save   Then e mail the report as  expected  desired    35493 Upgraded firmware  then rolled back Manually close the erroneous RAS  firmware to previous version and received   ticket    a RAS ticket for a non existent FC I O  blade   8 Known Issues    Quantum Scalar i6000 Release Notes  6 66883 12 RevA  February 2012       Documentation    The following documents are currently available for the Scalar i6000        Document Number    Document Title       6 01244 08 RevA    Scalar 16000 Addendum       6 66879 01 RevA    Scal
4. 16    FRU id    rollup report    graph labels are  unreadable    Reduce scope of query        32818    When generating an Advanced Reporting  Tape Alert report graph  the serial number  and barcode overwrite each other in the  graphical display     Select a smaller query set  or set the  label to one item  for example   Media ID        32820    Reservations not transferred when FC I O  blade host port fails over     When the FC ports fail over the host  needs to re login  PLOGI   PRLI  to  the FCB  Re login requires that  reservations be re established        32821    When setting Host Type to HP_UX and then  performing a LUN mapping operation   HP UX host may require a reboot for it to  see and communicate with the devices  attached to the I O blade     Reboot the HP UX host        33297    The library allows you to select tapes  located in I E stations for EDLM testing   but does not actually test them  Then it  indicates the test ran  and displays the  results as    suspect        Do not select tapes located in  I E stations for EDLM testing        33400          EDLM media scans do not complete  correctly or do not post correct results if a  library inventory is performed at same time  as the EDLM scan        Take the EDLM library managed  partition offline when performing a  library inventory so that a Ul initiated  inventory does not interfere with any  EDLM media scans  If a media scan is  in process  it will be paused while the  EDLM library managed partition is  offl
5. ar 16000 User   s Guide       6 66882 01 RevA    Scalar i6000 Planning Guide       6 01847 02 RevA    Quantum Encryption Key Manager User   s Guide       6 01884 02 Rev A    Quantum Encryption Key Manager Release Notes       6 66532 04 RevA    Scalar Key Manager Quick Start Guide       6 66531 04 RevA    Scalar Key Manager User   s Guide       6 66572 02 RevA    Scalar Key Manager Safety Information by IBM       6 66535 03 RevA       Scalar Key Manager Open Source License  Agreement          Contacting Quantum    Documentation    More information about this product is available on the Service and Support       website at www quantum com support  The Service and Support Website  contains a collection of information  including answers to frequently asked  questions  FAQs   You can also access software  firmware  and drivers through    this site     For further assistance  or if training is desired  contact Quantum        Quantum Technical Assistance  1 800 284 5101    Center in the USA        For additional contact information    Www guantum com support             To open a Service Request  www quantum com osr          For the most updated information on Quantum Global Services  please visit     www quantum com support       
6. b BBH4  IBM LTO 5  FC  8 Gb BBN2  HP LTO 3  FC  2 Gb L67Z  HP LTO 3  FC  4 Gb M69Z  HP LTO 4  FC  4 Gb H63Z  HP LTO 5  FC  8 Gb 157Z          1  For information about installing the LMC remote client  contact Quantum Support   2  Check with Quantum Support for the latest firmware   3  Logical serial number addressing  drive spoofing  is not supported        Backup Software To view a list backup software packages that have been tested for  Compatibility interoperability with the Scalar i6000  refer to the Quantum Software       Compatibility Guide at http   nww quantum com swcompguide aspXx        Compatibility and Support    Quantum Scalar i6000 Release Notes  6 66883 12 RevA    February 2012       Resolved Issues    This release of Scalar i6000 firmware resolved the following issues        Change  Request  Number    Service  Request  Number    Description    Solution       32967    1269266    Excessive use of cleaning station in SDLT  libraries slows picker down  wears down  picker fingers     Fixed        35493    1334904    Severity 1 ticket was generated for a non   existent FC I O blade after firmware  rollback     Fixed        35924    1360008    No RAS ticket received for RCU that  rebooted and failed to reconfigure one of  the drives to LME mode     Fixed        35970    1362124    Enhancement to the ADI recovery  algorithm     Fixed        36033    Add shutdown screens introduced on i10   19 1 to i8 4     Fixed        36163    Add unique EDLM scan selections per  pol
7. e  been stopped  use SMIT  gt  Devices  gt   Tivoli Storage Manager Devices  gt   Fibre Channel SAN Attached Devices   gt  Discover Devices Supported by  TSM to discover the change in  control path  Within TSM  update the  path to the library device  e g    dev   Ib1   The drives and their paths need  to be deleted and recreated  the  working drive  before backups can  resume   31173 Brocade switch puts data path failover in Use Brocade switch firmware code  failover loop  version 6 2 2e or higher   31487 Switching drive topology from loop to Use Brocade switch firmware code          fabric results in lost changer device when  using Brocade switches        version 6 2 2e or higher     Known Issues    Quantum Scalar i6000 Release Notes  6 66883 12 RevA  February 2012       Change  Request  Number    Service  Request  Number    Description    Workaround       32392    1215534  1297050    The device map shows that there was a  communication error between the MCB  and two FC I O blades  so the FC I O blade  control LUNs were removed from the  device list  When the MCB tried to connect  to the drive to write the firmware  it  skipped the removed FC I O blades in the  report LUNs scan and could not create a  path to the drive     In the past  the FC I O blades were added  and removed every time communication  was required  Since i8  the connections are  created and there is no recovery if a  connection is lost outside of rebooting the  FC I O blade     Reboot the library        328
8. icy selection     Fixed        36282    99  tape usage write pass threshold is too  low     too many tapes marked as bad     Fixed        36310    EDLM bug  if copy selection is    Copy if  tape is bad or suspect    and tape is marked  untested it will be copied     Fixed        36328    EDLM bug fixes and enhancements that  were fixed in i10 were brought over to  i8 4    e 34565     EDLM tries to scan  incompatible Media when importing or  bulk loading media and EDLM Policy   e 34997     If media changed slot  locations it is not scanned  Don   t base  scan on location coordinates  Scan if  tape is anywhere in the partition    e 35278     Starting EDLM with all drive s   offline does not produce a RAS or error  message     Fixed        36571       1372748       Standalone LMC doesn   t install on Solaris        Fixed        Resolved Issues    Quantum Scalar i6000 Release Notes  6 66883 12 RevA  February 2012       Known Issues    This release of Scalar i6000 firmware has the following known issues  This list  contains cumulative information for all previously released Scalar i2000 i6000    library versions                             Change Service   Request Request   Number Number   Description Workaround   16990 Installing Q EKM with IBM Java disables Upgrade Q EKM software to version  functioning Sun Java plug in and i2000 251Q GC00400 or later    Remote Management Interface  RMI  does  not function after Q EKM install    18432 After library software upgrade  an error Ign
9. ine  and will continue once the  partition is brought online again        Known Issues    Quantum Scalar i6000 Release Notes  6 66883 12 RevA                                     February 2012   Change Service   Request Request   Number Number   Description Workaround   33403 Once you configure the primary and The library remembers which server  secondary SKM servers on the library is primary and which is secondary   remote web client and encryption keys are   Once configured on the library  do  generated  if you switch the key servers not switch the primary SKM server to   i e   you try to make the primary server the   the secondary  or vice versa   secondary server  or vice versa   SKM will  not function    33507 After restoring a saved library Working as designed  To keep this  configuration that has the    Perform scans   from happening  deselect the  immediately when media is imported into      Perform scans immediately when  the library    policy enabled  the library media is imported into the library     performs a scan on all tapes in the policy before saving the library  partitions with this policy enabled because   configuration   the tapes appear as newly imported    33661 The library allows you to install 4096 bit Make sure the TLS CA  root    TLS CA  root  certificate for encryption key   certificate is 2048 bits   management but will not work with it    34027 When adding FC I O blades or EE blades to   When FC I O blades or Ethernet  a library that previously did
10. is an  incompatible setting  Choose a  higher setting or do not connect  8 Gb sec drives to an FC I O blade   recommended      Quantum Scalar i6000 Release Notes  6 66883 12 RevA                         February 2012  Change Service  Request Request  Number Number   Description Workaround  29161 On Scalar i6000 libraries  the SCSI port on No workaround   the MCB does not work   This is true  whether you upgrade from Scalar i2000 or  purchase a new Scalar i6000    29947 Host loses connection to IBM LTO 5 drives   IBM drives must be configured for  after drive topology is changed to Point to    Loop when configured behind an FC  Point  1 0 blade or if directly connected to  an FC HBA  If the drive is direct  connected to a FC switch then the  IBM drive can be configured to Point   to Point  Loop Preferred  or Loop  only   30302 A Scalar i6000 library with IBM LTO 5 FC Set the drives to either Loop  drives cannot be configured when drives Preferred or point to point in the  are not FC I O blade connected and are Scalar i6000 GUI  Do not set as  directly connected to a Fibre Channel autonegotiate   switch within a CA_Arcserve 12 5 1  environment   30394 Control path failover function is not It is recommend that you do not use  supported with Tivoli Storage Manager on   Control Path Failover with Tivoli  an AIX configuration  Storage Manager on AIX since doing  so will require manual intervention  when it fails over and when you fail  it back   Alternatively  once all TSM jobs hav
11. ore the error message  Connect  message states cannot connect to server  again and confirm software was   upgraded    18471 The library SCSI port does not properly Do not terminate a string of SCSI  terminate when the library is connected via   drives at the MCB    a string of drives    18643 When interrupting a move from the Manually remove the tape from the  cleaning tape back to the cleaning slot  the   picker   library does not place media in cleaning  slot    18702 Cannot connect to a library with SSL No workaround  Using SSL causes  enabled at an HTTPS address  extreme performance degradation   and is not recommended    21663 When initially enabling Host Port Failover For Host Port Failover on a FC I O  on a FC I O blade  the user is presented blade  port 2 cannot be enabled as  with 2 possible ports to set a the primary the primary port without first  port  port 1 and port 2  If the user selects enabling port 1 as the primary port   port 1and sets the new parameter Set port 1 as primary  save the  everything works as expected  If the user configuration  and then set port 2 as  selects port 2 during initial enable  and primary   sets the new parameter  the value is  rejected and the user gets an error  message stating that the    Primary port  must be online       27400 User can set 7404 FC blade initiator port to   1 Gb sec is not an acceptable setting    Known Issues          1 Gb sec when attached to a drive that  supports 8 Gb sec        for higher speed drives  it 
    