Home

Quantum Scalar 1000 Release Notes

image

Contents

1. IC and Scalar are registered trademarks of Advanced Digital Information Corporation All 6 00017 26 Rev A other product company or service names mentioned herein are the property of their respec tive owners Compatibility Matrix Refer to Table 1 for information on drive and auxiliary firmware compatibility with Scalar 1000 641 firmware Table 1 Drive and Auxiliary Firmware Compatibility Matrix Component Firmware Version RMU 161A 00005 186A 00007 and 210A 00002 SNCs SNC 3000 3 43 18 SNC 5100 4 45 10 4 45 15 and 4 45 16 Scalar DLC 2 6 Drive Types LTO 1 53J1 36UC and 4561 LTO 2 53Y2 42D1 and 4APO AIT 1 04E5 AIT 2 0200_CY10 AIT 3 0209 0001 3590 B1A DOIA_572 3590 E1A DOIF_26E DLT 4000 V151 DLT 7000 V107 DLT 8000 V80 SDLT 220 V82 SDLT 320 V82 December 2006 ADIC Resolved Issues Problems resolved in this release of Scalar 1000 641 Firmware are as follows Change Request Description Number 25122 SAC 93 errors sometimes occurred on drives while reinitializing the library To help eliminate these errors there is now a 5 second waiting period for IBM LTO drives If an ACK is not returned for the drive there are two retries resulting in a 15 second total time out In the event of a failure during higher level functions the drive communications error is reported without additional waiting 30224 Corrects a condition in whi
2. Product Scalar 1000 641A 00003 Date December 2006 Contents Page Topic 1 Purpose of this Release 1 New Enhancement 2 Compatibility Matrix 3 Resolved Issues 4 Known Issues 4 Documentation Purpose of this Release This Scalar 1000 641 firmware release adds one new enhancement that extend the capabilities of the Scalar 1000 Library This document describes the new enhancement as well as corrections made to issues encountered in previous releases of the library Visit www adic com for additional information about Scalar 1000 641 Firmware and previous releases New Enhancement The following enhancement is in this release of the Scalar 1000 e Improved label scanning during teaching Previously teach values could vary as much as 2mm between teaches which could generate SAC 7C errors To improve scanning accuracy and reduce variance errors labels are now scanned at least twice If the X or Y value exceeds 0 5mm either X Y or both are scanned again After scanning the largest X value and smallest Y value are passed to the teach function to calculate cell positions Also to help eliminate SAC 7B errors that occurred during teach mastering the reach motor extends 1mm farther while extending to the teach master bracket Finally to alert users when a scanner might need replacing during the teach a warning message appears on the operator panel when the scan beam is not level or is jittery December 2006 ADIC AD
3. ch the operator panel and Log_Sense reported the drive s firmware level incorrectly because a string variable was not initialized correctly 30986 Corrects a condition that occurred when printing the log information in the 630 logs in which the retract retries was incorrect for previous versions 33963 Media settings are now preserved during a firmware upgrade When upgrading from 630 to 640 firmware if the media mode was set to extended it was reset to default mode after the upgrade 36097 Corrects a condition in autocleaning immediate mode in which an expired AIT cleaning tape resulted in move failure The library now recognizes an expired AIT cleaning cartridge and marks it expired in the database Additional functionality has been added to force a cleaning event on AIT 3 drives when necessary 37030 Corrects a condition that caused a SAC 7A Reach Homing Error 38272 Current scan velocity and cleaning cartridge information is now included in the library log 38796 Corrects a condition that prevented toggling element addressing between old and new styles for ADSM 39285 The library log no longer fills with meaningless errors when the library has no RMU installed Only one message is generated when no RMU is installed 39948 Corrects a condition for AIT and SDLT drives that caused SAC 7C errors due to drive recovery functionality implemented in the 640 code 40727 Total wait tim
4. e for AIT drives is increased to 15 seconds to reduce the occurrence of SAC 93 errors Initial wait time is now 5 seconds If there is no response the entire command sequence is retried two more times providing 15 seconds total time before reporting a drive communication failure 42786 Systems with LTO drives now have a longer wait time to ensure that the power on self test POST completes This longer wait time eliminates SAC 96 errors that occurred on some libraries when auto inventory was turned off which resulted in shorter wait times that prevented the POST from completing 42795 Corrects a condition in which the SDLT get profile was incorrect which caused SAC 7C errors December 2006 ADIC Known Issues Due to a safety mechanism in the system if you revert to a previous firmware version for example from 641 to 630 the library resets the entire database to use the default values This safety feature protects the library against incompatibilities that might be caused by using database values from a higher firmware version when reverting to a lower firmware version Documentation The following documents are currently available for the Scalar 1000 Document Number Document Title 6 01150 01 Scalar 1000 Planning Guide 6 00054 03 Scalar 1000 Operator Guide 6 00055 02 Scalar 1000 SCSI Reference Manual December 2006 ADIC

Download Pdf Manuals

image

Related Search

Related Contents

安 全 デ ー タ シ ー ト  Samsung FQV113T001 Instrukcja obsługi  USER`S MANUAL MANUEL D`UTILISATEUR  Gefen Home Theater Scaler Pro  CÁMARA DOMO DE ALTA VELOCIDAD  見積書 例  Garmin Forerunner 610 Quick Start Manual  SIRENA INTELIGENTE (IS2100 G)  手足などを挟む事故等に係る施設管理者への注意喚起の徹底について  DriveIT Low Voltage AC Drives User`s Manual, ACS550  

Copyright © All rights reserved.
Failed to retrieve file