1. CERTANCE       Release Notes for Certance CP3100  Supplement to the User   s Guide dated November 2003    The CP3100   s internal management software  DPWare  contains a  duty cycle  that runs  every few seconds  checking for any outstanding requests and executing them  These  requests may originate from the Device Status and or any Virtual Tape Cartridge Properties  menu commands that are entered  When entering a request on these menus  the CP3100  may not process the request immediately  When making changes in the Device Status  menu  it is recommended to allow the system about 15 seconds to process the new change     The default behavior of the CP3100 is to report a virtual tape cartridge size of 54GB when  you view the it through the RemoteAdmin web browser interface  With some backup  software  the size will be shown differently  For example  where a DAT 72 tape drive is  attached to the CP3100  the virtual tape cartridge will report a size of 36GB  uncompressed  capacity   When a DDS 4 tape drive is attached to the CP3100  the virtual tape cartridge will  report a size of 20GB to the backup software     If a virtual tape cartridge is set to a specific size via the RemoteAdmin web browser interface   the CP3100 may still report the maximum physical cartridge size to the backup software   However  the amount of data that can be backed up to the virtual tape cartridge will be limited  to the value that was set via RemoteAdmin     If your backup software is set up to reserv
2. IALLY MIGRATED  and or PARTIALLY ARCHIVED   In this case  either the archive process to the  physical tape cartridge or migration process off the virtual tape cartridge was not  completed  The data is not recoverable because the system will not be able resume  a backup on a partially archived physical tape cartridge  To recover  the system  needs to halt all data archive commands prior to making any changes  Click on the  virtual tape cartridge folder Properties  Click on Advanced Operations and select    Do  Not Archive     Return to the main device status screen  Wait 15 seconds  then return  to the virtual tape cartridge Properties  The virtual tape cartridge can now be  removed as follows  Click on the virtual tape cartridge    Properties     Click on  Advanced Operations and select    Remove Virtual Cartridge     Create a new virtual  tape cartridge  if necessary  by following the User Guide procedure     
3. When choosing Shutdown or Restart from the RemoteAdmin System Tools menu  there will  be no indication of when the CP3100 is shut down or when a restart occurs  To cycle power  off after choosing Shutdown for the CP3100  be sure to allow two full minutes between   choosing Shutdown and turning off power  In order to know when the unit has restarted  you    will need to logout of the Remote Admin and then log back in  If the login is successful  the  Restart has completed     When archiving a virtual tape cartridge for the first time  it is necessary to insert a completely  blank or erased physical tape cartridge into the tape drive  If a non blank physical tape  cartridge is used  it will be ejected  to avoid accidentally overwriting valuable data that may  be on that tape cartridge   You can use the RemoteAdmin tool to perform an erase of the  physical tape cartridge as follows    o Eject the physical tape cartridge from the tape drive    o Click on the erase icon in the Physical Drive section of the Device Status page  You   will see a confirmation message for the erase    o Insert the physical tape cartridge to erase into the tape drive when requested    o After the erase is complete  the physical tape cartridge will be ejected    o Insert the tape again  and the archive will complete     When archiving a virtual tape cartridge when it has already been successfully archived  you  must insert the same physical tape cartridge you used for the previous archives of that  parti
4. cular virtual tape cartridge  If that tape no longer exists  it is still possible to perform the  archive operation    o Ifyou do not have a blank physical tape cartridge  first perform an erase as outlined  above    o Go to the RemoteAdmin web interface and click on the Device Status icon    o Go to the Virtual Loader section and click on the Configure button next to the slot  number you wish to archive    o When the Configuration page opens  go to Advanced Operations and choose  Use  New Physical Cartridge     o Click Submit  Now insert the blank physical tape cartridge and the archive should  continue as normal  The archive will only write the current data for the virtual tape  cartridge to the physical tape  Any data that was previously archived  even if not  migrated off the virtual loader  will not be written to the physical tape cartridge     The CP3100i RemoteAdmin includes an automatic refresh option on the Device Status page   When set to OFF  to see updates of the CP3100 device status page it is necessary to  manually refresh the page using your browser   s Refresh or Reload button  The drop down  controller can be found in the upper left portion of the main status display screen  This drop   down option allows the user to select the timing interval for subsequent screen refreshing  To  change or deactivate this option  click on the drop down arrow and choose either an interval  refresh rate  in seconds  or the ON OFF options     Troubleshooting when a Physical Tap
5. e Cartridge is lost  destroyed or rejected     o Physical Tape is rejected for unknown reason  could be that it contained trace  data  or a previous archive attempt was aborted   Simply click on the virtual tape  cartridge folder Properties  Click on Advanced Operations and select    Use New  Physical Cartridge     Resume physical tape cartridge archive by inserting a blank  tape in the DAT drive     o Physical Tape is lost or not recoverable  data NOT MIGRATED   The virtual tape  cartridge is ready to archive to a physical tape cartridge  The new physical tape  cartridge is rejected because the system is looking for the original tape  Click on the  virtual tape cartridge folder Properties  Click on Advanced Operations and select     Use New Physical Cartridge     Resume the physical tape cartridge archive by  inserting the tape into the DAT drive     o Physical Tape is lost or not recoverable  data WAS MIGRATED   The data was  archived to a physical tape cartridge and then migrated off the virtual tape cartridge   This means that the archived data is only recoverable from the original physical tape    March 2004    cartridge  To resume host backup operations  the virtual tape cartridge must be  removed  Click on the virtual tape cartridge    Properties     Click on Advanced  Operations and select    Remove Virtual Cartridge     Create a new virtual tape  cartridge  if necessary  by following the User Guide procedure     Physical Tape is lost or not recoverable  data was PART
6. e an autoloader slot for a cleaning cartridge  it will  be necessary to remove that reservation  The CP3100 does not require cleaning and will not  recognize a  cleaning  tape     On the Device Status page of the RemoteAdmin Web browser interface  there is a Configure  button under Virtual Loader that can be used to create a tape name of your choice  The limit  on the number of characters for the tape name is 31     Some backup software programs allow you to view the serial number of attached devices   The CP3100 passes the serial number of the attached physical tape drive to the host if the  host should query  Currently  the CP3100 may insert a spurious character in front of the serial  number  e g   SHV00029 instead of HV00029  This does not affect the compatibility of the  CP3100 to the backup software in any way     You can view the status of an Archive operation on the physical tape drive by viewing the  Device Status page in the RemoteAdmin web browser interface  When you see a green tape  icon next to a slot number  no unreported errors exist on that slot  You also may see an  Archive icon on the right hand side of the Virtual Loader section of the web page for that slot   This icon may be ignored     Currently  the CP3100 may not pass through to RemoteAdmin a  need to use cleaning tape   message from the physical tape drive  The Administrator should check the LEDs on the  physical tape drive to determine if there is a need to use a cleaning tape in the tape drive     
    