1. RRARRARINTARARBRRA O O oOo0oo0oo0o000000000000 1 Latch 100 blade XX SANbox 9000 Series Chassis Replacement Guide QLOGIC Remove Power Supply Blades WARNING The Power Supply blade faceplate and internal surfaces can become very hot Handle with care Rotate the latch to the full open position Pull the Power Supply blade by the latch to disengage the blade from the midplane connector Carefully slide the Power Supply blade out of the chassis Remove the Fan Blades Rotate the latch to the full open position Pull the Fan blade by the latch to disengage the blade from the midplane connector Carefully slide the Fan blade from the chassis Remove CPU Blades Label the CPU blades CPUO and CPU1 Rotate the latch to the full open position Pull the CPU blade by the latch to disengage the blade from the midplane as shown 1 Latch PSO blade 1 Latch FANO blade 1 Latch CPUO blade 2 CPU1 blade 59244 00 A XX QLOGIC SANbox 9000 Series Chassis Replacement Guide Remove Chassis from the Rack Using a crosshead screw driver remove the screws that secure the chassis to the rack Slide the chassis
2. 59244 00 A XX SANbox 9000 Series Chassis Replacement Guide QLOGIC Observe Heartbeat LED Observe the Heartbeat LED on the CPU blade It should blink once per second esoo E 8 If the Heartbeat LED is showing a different 9 blink pattern refer to the Installation Guide for diagnostic procedures or contact your authorized maintenance provider 1 Heartbeat LED Verify the POST Results oase 10 0 01 s Switch Login admin Open a Telnet session and enter the Password password Show Blade command to display the SANbox gt show blade diagnostic status for all blades You can Blade Blade Port Admin Oper Fault Temp Voltage also use the Switch tab and Blade Info D Type Range State State Status Status Statusi tab of the QuickTools interface Too FC4G16 0 15 Online Online None Normal Good O1 FC4G16 16 31 Online Online None Normal Good 02 Online NotInst 03 Online NotInst 04 Online NotInst 05 Online NotInst 06 Online NotInst 07 Online NotInst CPUO CPU N A Online Online None Normal Good CPU1 CPU N A Online Online None Normal Good PSO PSFB N A N A N A None N A N A PS1 PSFB N A N A N A None N A N A FANO FANFB N A N A N A None N A N A FAN FANFB N A N A N A None N A N A MP MP N A N A N A None N A N A Reinstall License Keys The old license keys are not
3. QLOGIC SANbox 9000 Series Chassis Replacement Guide 1 Chassis with shipping covers WARNING This guide describes the procedure for one person to replace a SANbox 9000 Series chas sis It involves removing blades while the switch is in the rack and then removing the empty chassis Depending on the location of the switch in the rack it may be easier to remove the populated switch from the rack first In this case to avoid injury or damage to the switch arrange for the help of an assistant when removing or installing a populated switch Tools Required E Crosshead screw driver medium mE ESD wrist strap CAUTION m Always use an ESD wrist strap when handling and blades and modules E To avoid damage to the I O blades CPU blades Power Supply blades and Fan blades do not touch the circuit boards and electrical components 59244 00 A SANbox 9000 Series Chassis Replacement Guide XX QLOGIC Backup the Switch Configuration Create a backup of the switch configuration if one does not already exist and upload it from the switch to the management workstation Open a Telnet session and enter the Config Backup command to create the file on the switch Then use FTP to upload it to the management workstation You can accomplish the same task using the Archive function of the QuickTools interface Inventory Feature Licenses Enter the Feature Log command to display the installed feature licen
4. an blade latch and slide the blade into the chassis until it contacts the midplane connector Rotate the latch right to left to lock the Fan blade in place 1 Screws 59244 00 A XX QLOGIC SANbox 9000 Series Chassis Replacement Guide Reinstall Power Supply Blades NOTE Power Supply blade installation is easier when installed after the Fan blade below it Open the Power Supply blade latch and slide the blade into the chassis until it contacts the midplane connector Rotate the latch right to left to lock the Power Supply blade in place Reinstall I O Blades Install the I O blades and panels in the new chassis matching the slot label on the blade with the chassis slot Slide the I O blade into the slot guide until it makes contact with the midplane connector Rotate the blade latch upward to lock the I O blade in place Reconnect the Fibre Channel port cables according to their labels Reconnect Ethernet and Serial Cables Reconnect the Ethernet and serial cables to the CPU blades or Maintenance Panel Reconnect HyperStack cables to the CPU blades Power Up the Switch Reconnect power cords to the Power Supply blades Fasten the restraint bails on the plugs Move the On Off switches on both Power Supply blades to the On position
5. er FAM033100024 SymbolicName SANbox ActiveSWVersion V6 2 X X XX XX ActiveTimestamp day month date time year DiagnosticsStatus Passed 1 Heartbeat LED 59244 00 A XX QLOGIC Disconnect Ethernet and Serial Cables Disconnect Ethernet cables from CPU blades and the Maintenance Panel Disconnect HyperStacking cables from the CPU blades Disconnect Fibre Channel Port Cables Label I O blades by slot number I O blade slots are numbered O0 I07 Label Fibre Channel port cables by slot number and port number E 4 Gbps I O blade ports are numbered 0 15 from top to bottom left to right m 10 Gbps I O blade ports are numbered 0 4 top to bottom left to right Disconnect Fibre Channel port cables Remove I O Blades Connect an ESD wrist strap to a ground point on the rack Rotate the I O blade latch to the full open position Pull the I O blade by the latch to disengage the I O blade from the midplane Carefully slide the I O blade out of the chassis Remove I O blade panels in the same way 59244 00 A SANbox 9000 Series Chassis Replacement Guide memi Foon oOo0oo00000000000000 oOo0oo0oo0000000000000 oOo0oo0o0000000000000 oo0oo00000000000000 oo0oo0o0000000000000
6. out of the rack Slide the chassis out of the cabinet until the rail latches drop down to stop the chassis Lift up on the latches on both sides and finish removing the empty chassis If you have installed license keys make note of the chassis serial number You will need this number to obtain new license keys later Remove Brackets and Rails Make a note of the location and orientation of the brackets and the rails Remove the brackets and rails from the chassis and set them aside along with the screws You will install them on the new chassis 1 Bracket 2 Rail Prepare the New Chassis Remove the shipping covers from the ends of the new chassis Each cover is secured with six screws three on each side Install the brackets and the rails on the new chassis as they were installed on the old chassis 1 Covers 59244 00 A 5 SANbox 9000 Series Chassis Replacement Guide XX QLOGIC Install New Chassis in the Rack Slide the new chassis into the cabinet rails Fasten the switch rails to the cabinet rails with two screws Reinstall CPU Blades Install the CPU blades in slots CPUO and CPU1 of the new chassis according to the labels on the CPU blades Open the CPU blade latch and slide the CPU blade into the chassis until it makes contact with the midplane connector Rotate the latch to lock the CPU blade in place Reinstall Fan Blades Open the F
7. ses Make note of the license keys so that the feature licenses can be installed in the new chassis If you have installed license keys enter the Show Version command and make note of the chassis serial number You will need this number to request new license keys later Power Down the Switch Isolate the switch from the fabric Confirm that the primary CPU Heartbeat LED is showing the normal 1 blink per second This allows the switch to correctly report power supply status Move the On Off switch to the Off position on both Power Supply blades Unfasten the restraint bails from the plugs and unplug the power cords from both Power Supply blades Switch login admin Telnet Password password Sanbox gt admin start Sanbox admin gt config backup SANbox admin gt exit ftp lt ip_address gt FTP User images Password images ftp gt binary ftp gt get configdata ftp gt bye SANbox gt feature log Mfg Feature Log 1 day mon date hh mm ss year Switch Licensed for HyperStack tm capability 200000 LCRXIET7KXSXO SANbox gt show version kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk k k k Command Line Interface SHell CLISH k k k kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk SystemDescription SANbox 9000 FC Switch EthNetworkAddress 10 20 11 192 use set setup system EthMACAddress 00 c0 dd 00 71 ee WorldWideName 10 00 00 c0 dd 00 71 ed ChassisSerialNumb
8. valid with the new chassis serial number Visit www QLogic com Support Product Feature Activation License Key Activation Center Replace License Keys to obtain new license keys to replace those installed on the original chassis You will need the following information Original chassis serial number New chassis serial number Show Version commana m Your email address With the new license keys enter the Feature Add command to install license keys that were installed on the original chassis SANbox gt admin start SANbox y n Log Msg admin n y gt feature add XXXXXXXXXXXXX License upgradefor HyperStack tm capability This feature upgrade does NOT require a switch reset Do you want to continue with license upgrade procedure day mon date hh mm ss sss CST year C 8400 006B Switch Upgrading License for HyperStack tm capability Log Msg day mon date hh mm ss sss CST year C 8400 0047 Switch New licenses are being instal led Copyright 2007 QLogic Corporation SANbox is a trademark of QLogic Corporation 59244 00 A
Download Pdf Manuals
Related Search
Related Contents
User Manual - Stud Indicator Stream 93i Issue 1 Europe_Italian.indd LEDテーブルライト専用充電器 取扱説明書 mR10000/mR20000 SD Memory Card (/EM1 Option) User`s Manual document 2013年11月 Ditec DAB105 Portas batentes Quick Start Guide & Installation manual Guide de d`emarrage et PAR200 Installation Manual 形 V680S-HMD6D-ETN Copyright © All rights reserved.