Home

Powerware 300 VA User's Manual

image

Contents

1. 2 Not Used Not Used 3 Normally Open On Battery Contact A normally open contact that closes 15 seconds pulls to Common after the UPS switches to battery power 4 Common The signal ground for all signal pins 5 Normally Open Low Battery Alarm Contact A normally open contact that closes pulls to Common during a Low Battery Alarm 6 Normally Closed Low Battery Alarm Contact A normally closed contact that opens releases from Common during a Low Battery Alarm This tells some shutdown software when to start a computer shutdown 7 Not Used Not Used 8 Normally Closed On Battery Contact A normally closed contact that opens 15 seconds releases from Common after the UPS switches to battery power 9 Not Used Not Used 6 Powerware 3110 User s Guide RevB www powerware com Features Battery Start Feature The Battery Start feature allows you to turn on the UPS when utility power is not available The battery start range is up to about 4096 of nominal input otherwise the UPS displays an input voltage fault and the alarm beeps RJ 11 or RJ 45 Surge Protectors The RJ 11 or RJ 45 surge protectors are located on the side panel and are labeled IN and OUT This feature accommodates an RJ 11 connector that provides protection for modems fax machines or other telecommunications equipment As with most modem equipment it is not advisable to use this jack in digital PBX Private Branch Exchange environments Low
2. CHAPTER 2 FEATURES This section covers Using the USB or DB 9 communication port Starting the UPS on battery Communication Options The UPS is equipped with a USB and a DB 9 communication port Either the USB port or the DB 9 communication port may be used to monitor the UPS however they cannot operate simultaneously USB Port The UPS can communicate with a USB compliant computer using LanSafe Power Management Software v4 15 or higher To establish communication between the UPS and a computer l Connect the USB cable to the USB port on the UPS rear panel Connect the other end of the USB cable to the USB port on your computer 2 Install the LanSafe software and USB drivers according to the instructions provided with the Powerware Software Suite CD Powerware 3110 User s Guide RevB www powerware com 5 Features DB 9 Communication Port Powerware offers an accessory interface kit that allows you to connect many types of computer systems to the UPS communication port For specific information on Powerware interface kits call your service representative Contacts consist of open collector circuits capable of switching up to 30 Vdc 6 mA resistive load Table 1 Communication Port Pin Assignment Pin Signal Type Function 1 RS 232 Level Shutdown 12 Vdc signal held for 5 seconds on this pin shuts the UPS down 120 seconds later The UPS restarts after 15 seconds when utility power returns
3. POWERWARE 3110 300 700 VA User s Guide www powerware com Class B EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help ICES 003 This Class B Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES 003 Cet appareil num rique de la classe B respecte toutes les exigences du Reglement sur le mat riel brouilleur du Canada Requesting a
4. 0 User s Guide RevB www powerware com CHAPTER 5 TROUBLESHOOTING The front panel LEDs and an audible beep indicate the UPS status see Table 6 The UPS beeps whenever the unit is on battery power or an alarm is present Table 6 Troubleshooting Alarm or Condition Possible Cause What to Do A Normal operation None The UPS is operating in Normal mode Nu Line loss due to A Se Utility power outage Wait for utility power to return A PS Loose plug connection Check the power cord connections AN e ripped circuit breaker Reset the circuit breaker 1 beep every 5 seconds Power cord failure e Contact your service representative for a new power cord Prepare for a UPS shutdown Save your work and turn off your equipment The unit automatically restarts when acceptable power returns si Low battery alarm shutdown is X SER imminent AN N 2 beeps every 5 seconds NC The battery needs charging or V a service A 7N 3 beeps every 5 seconds Turn the UPS off and plug the UPS into a power outlet for 24 hours to charge the battery Turn the UPS on to test the battery If the alarm still beeps see Replacing Batteries on page 9 to replace the battery Ni The battery is discharged and i X battery power is not available AN 3 beeps every 5 m
5. Date of failure or problem Symptoms of failure or problem Customer return address and contact information Powerware 3110 User s Guide RevB www powerware com Troubleshooting If repair is required you will be given a Returned Material Authorization Powerware 3110 User s Guide RevB www powerware com 17 Troubleshooting 18 Powerware 3110 User s Guide RevB www powerware com
6. Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives Harmonized Standards EN 50091 1 1 and EN 50091 2 e EU Directives 73 23 EEC Council Directive on equipment designed for use within certain voltage limits 93 68 EEC Amending Directive 73 23 EEC 89 336 EEC Council Directive relating to electromagnetic compatibility 92 31 EEC Amending Directive 89 336 EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark For copies of the EC Declaration of Conformity contact Powerware Corporation Koskelontie 13 FIN 02920 Espoo Finland Phone 358 9 452 661 Fax 358 9 452 665 68 Powerware is a registered trademark of Powerware Corporation Copyright 2001 2003 Powerware Corporation Raleigh NC USA All rights reserved No part of this document may be reproduced in any way without the express written approval of Powerware Corporation 1 Installation uli ee ee a Inspecting the EQUIPMENT e s os da CR Safety PEeCaUtIOFIS taa aa b os E oes np gol ans QUISO ta RR C REO sen LEE WPS Top Md Side Panels 2s ute RS Re ru xe tere ter tu ve ede a etd 2 PORES sos occi A AE 1 1 1 2 3 5 COMMUNICATION UPUONS xx eom etg Raye m Neve a eer EUR ME tp RN Re eS 5 USB ze e HP PEL mE ad e e 5 DB 9 Commu icati n POE 5 ts S RT ato idee VA een ts 6 Battery StartEBaltUfe us se s oA Lene NER TI RE EESAE PINNG
7. RASENENERSIXS 7 HJ T1 0r BJ 45 Surge Protectors o miis iras Rb btt e hem RUNE SEP dE aed 7 3 UPS Maintenance 225262 2s0 sees ru mam Rack REIR Ru 9 9 9 9 1 UPS and Battery aree or hd set ds do de ee d ad o RR SLOTING Me UPS atado dada Replacing Batteries 3 eg A ee f e e de ete tdg Recycling the Used Battery x ox Lee b V ERG ME ea de ee RI ades 1 4 Specifications nu ollie sa eee Eon AA IR ora se Ran 13 5 Troubleshooting 22 121 wats pease Shaves GER ieee Ex eaa oe 15 Servico ANG SUPON sd o otium cu RA ne sor ART qu A Ree ae Lr aot Ar Le ter 16 Powerware 3110 User s Guide RevB www powerware com i Table of Contents ii Powerware 3110 User s Guide RevB www powerware com CHAPTER 1 INSTALLATION This section explains Equipment inspection Safety precautions UPS installation UPS top and side panels Inspecting the Equipment If any equipment has been damaged during shipment keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage If you discover damage after acceptance file a claim for concealed damage To file a claim for shipping damage or concealed damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to your service representative Safety Precautions Read the following precautions before you install the UPS IMPORTANT SAFETY INSTRUCTIONS
8. SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries Please read all instructions before operating the equipment and save this manual for future reference This UPS contains its own energy source batteries The output receptacles may carry live voltage even when the UPS is not connected to an AC supply Do not remove or unplug the input cord when the UPS is turned on This removes the safety ground from the UPS and the equipment connected to the UPS Powerware 3110 User s Guide RevB www powerware com Installation Toreduce the risk of fire or electric shock install this UPS in a temperature and humidity controlled indoor environment free of conductive contaminants Ambient temperature must not exceed 40 C 104 F Do not operate near water or excessive humidity 9596 max With the exception of the user replaceable battery all servicing of this equipment must be performed by qualified service personnel Before maintenance or repair all connections must be removed Before maintenance repair or shipment the unit must be completely switched off and unplugged or disconnected CAUTION Important Notice The UPS ground earth conductor carries leakage current from the loads in addition to any leakage current generated by the UPS This UPS generates no more than 0 5 mA of current 120V model or 1 mA of curre
9. ating normal operation If the unit continues to beep or if the indicator is off even though input power is available from the wall outlet see Troubleshooting on page 15 NOTE Let the unit charge the battery for at least 3 hours You may use the unit while the battery charges but the battery backup runtime will be reduced until the battery is fully charged This will take up to 8 hours after a full discharge while the UPS is fully loaded UPS Top and Side Panels Figure 1 and Figure 2 identify features of the 120V USA models with attached input line cord Figure 3 and Figure 4 identify features of the 230V European models which have a connector for the input line cord as well as IEC output receptacles Fault ron jer Indicator l Ts Output Receptacles Battery and Surge Protection Output Receptacles Surge Protection Only Figure 1 120V Model Top Panel Powerware 3110 User s Guide RevB www powerware com Installation Communication Port RJ 11 or RJ 45 Surge Protectors pi Port e al OM A ART etd Lr Power Cord On Standby Switch Circuit Breaker Figure 2 120V Model Side Panel CONTINUOUS SURGE PROTECTION Powerware 3110 User s Guide RevB www powerware com
10. ery 0 100V and 152 160V On Battery 0492V and 272 290V Nominal Frequency 50 60 Hz auto sensing 57 63 Hz 60 Hz 47 53 Hz 50 Hz Efficiency Normal mode gt 95 Noise Filtering Full time EMI RFI filtering Overcurrent Protection Resettable circuit breaker Connections IEC 320 C14 input connector Input fault current 15A maximum Attached 5 15P power cord Power Levels rated at nominal inputs PW3110 300i 300 VA 180W PW3110 550i 550 VA 330W PW3110 700i 700 VA 420W PW3110 300 300 VA 180W PW3110 550 550 VA 330W PW3110 700 700 VA 420W Total Output Current 10A maximum Load Compatibility Switch mode power supply or resistive load Output Frequency 50 60 Hz 1 Hz of nominal frequency Battery mode Connections 4 5 15 receptacles with UPS 4 IEC 320 C13 receptacles with UPS and surge protection 2 IEC 320 C13 receptacles with surge protection only and surge protection 2 5 15 receptacles with surge protection only Powerware 3110 User s Guide RevB www powerware com 13 Specifications Table 3 Battery Configuration 300 VA 1 12V 4 2 Ah or 2 6V 4 0 Ah internal battery s 550 VA 1 12V 7 0 or 7 2 Ah internal battery 700 VA 1 12V 9 Ah internal battery Voltage 12 Vdc Type Sealed maintenance free valve regulated lead acid Charging 8 hours to 9596 capacity with output fully loaded Monitoring Advanced mo
11. etal parts on top of batteries ELECTRIC ENERGY HAZARD Do not attempt to alter any battery wiring or connectors Attempting to alter wiring can cause injury Replace batteries with the same number and type of batteries as originally installed in the UPS DO NOT DISCONNECT the batteries while the UPS is in Battery mode Powerware 3110 User s Guide RevB www powerware com 9 UPS Maintenance The 230V models require replacement by qualified service personnel l Contact your service representative to order a replacement battery It must be the same type and rating as the original battery see Table 3 on page 14 Switch off and unplug the protected equipment from the UPS Turn off the UPS and disconnect the power cord Turn the UPS upside down Battery Figure 5 Removing the Battery Cover and Battery 5 Remove the battery cover Models 550 and 700 Use a screwdriver to remove the four screws securing the battery cover and lift the battery cover off Model 300 Press down on the battery cover tabs and slide the battery cover off Lift the battery up and out of the case Disconnect the red and black cables from the used battery Replace the battery See Recycling the Used Battery for proper disposal 9 Reconnect the cables to the new battery red to positive black to negative and slide the battery back into the case 10 Powerware 3110 User s Guide RevB www powerware com UPS Ma
12. intenance 10 Replace the battery cover by pushing the cover until it snaps into place securely Replace any battery cover screws that were removed to access the battery 11 Turn the UPS right side up Reconnect the UPS power cord and turn the unit on 12 Reconnect the equipment Switch on the protected equipment one piece at a time Recycling the Used Battery Contact your local recycling or hazardous waste center for information on proper disposal of the used battery e Do not dispose of the battery or batteries in a fire Batteries may explode Proper disposal of batteries is required Refer to your local codes for disposal requirements e Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic E CAUTION Do not discard the UPS or the UPS batteries in the trash This product contains sealed N lead acid batteries and must be disposed of properly For more information contact Pb your local recycling or hazardous waste center Powerware 3110 User s Guide RevB www powerware com 11 UPS Maintenance 12 Powerware 3110 User s Guide RevB www powerware com CHAPTER 4 SPECIFICATIONS Table 2 Electrical Powerware Corporation reserves the right to change specifications without prior notice Nominal Voltage 230V Model 230V 120V Model 120V Power Factor 0 6 Voltage Range Online 90 452V Online 176 272V On Batt
13. inutes The UPS automatically recharges the battery The alarm clears when the battery is recharged NOTE If the UPS has not recharged the battery after 24 hours the alarm changes to 3 beeps every 5 seconds and the battery must be replaced See Replacing Batteries on page 9 to replace the battery Powerware 3110 User s Guide RevB www powerware com 15 Troubleshooting Alarm or Condition NP Possible Cause What to Do Power requirements exceed the Remove some of the equipment from the UPS You may A UPS capacity need to obtain a larger capacity UPS PN A IN 1 beep every half second W Output short circuit Turn off or unplug the equipment connected to the UPS TS A t Input voltage is out of range Turn off the UPS until acceptable input voltage mm A when the UPS is turned on restored UPS fault Contact your service representative Continuous beep Service and Support 16 If you have any questions or problems with the UPS call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a UPS technical representative In the United States 1 800 356 5737 or 1 608 565 2100 Europe Middle East Africa 44 17 53 608 700 Asia 852 2830 3030 Australia 61 3 9706 5022 Please have the following information ready when you call the Help Desk Model number Serial number Version number if available
14. nitoring for earlier failure detection and warning Backup Time 300 550 VA 3 minutes at full load 5 minutes typical load 700 VA 2 5 minutes at full load 5 minutes typical load Transfer Time 4 ms typical Table 4 Weights and Dimensions UPS Dimensions HxWxD 300 VA 5 9 x 39 3 x 15 0 cm 2 3 x 15 5 x 5 9 550 700 VA 7 9 x 37 6 x 17 2 cm 3 1 x 14 8 x 6 8 UPS Weight 300 VA 3 0 kg 6 6 Ib 550 VA 4 2 kg 9 2 Ib 700 VA 4 3 kg 8 4 Ib Table 5 Environmental and Safety Operating Temperature 120V Model 230V Model 0 C to 40 C 32 F to 104 F Storage Temperature 15 C to 50 C 5 F to 122 F If the UPS is stored the batteries should be recharged every 6 months If stored above 25 C 77 F battery life is reduced and should be recharged more often Ventilation Air around the unit must be free of dust chemicals or other materials that corrode or contaminate Relative Humidity 5 95 RH noncondensing Audible Noise Online Less than 40 dBA typical at one meter On Battery Less than 45 dBA typical at one meter Surge Energy Rating 450 joules Surge Suppression ANSI C62 41 Category A formerly IEEE 587 IEC 61000 4 5 Level 3 Safety Conformance UL 1778 UL 497A EN 50081 1 1 and EN 60950 CAN CSA C22 2 No 107 1 Safety Markings UL cUL NEMKO CE EMC Class B FCC Part 15 ICES 003 EN 50091 2 14 Powerware 311
15. nt 230V model e To limit the total leakage current to 3 5 mA the load leakage must be limited to 3 mA on the 120V model and 2 5 mA on the 230V model e f you do not know the load leakage current replace the UPS power cord 230V model only with a power cord that uses a locking plug with a minimum rating of 10A such as IEC 309 e f you do not have a matching receptacle consult an electrician to install the proper receptacle e The three wire receptacle that you plug the UPS into must have a good low impedance ground protective earth connection to provide a safe path for leakage current Quick Startup The Powerware 3110 provides protection against many power problems including power outages It also provides spike suppression and line noise filtering to protect your equipment 1 On 230V models plug the UPS power cord into the input connector on the UPS side panel 2 Plug the equipment to be protected into the UPS output receptacles DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating elements 2 Powerware 3110 User s Guide RevB www powerware com Installation 3 Start the UPS by pressing the switch as shown in Figure 2 or Figure 4 on page 4 The indicator illuminates indicating that power is available from the UPS output receptacles The unit beeps and the front panel LEDs illuminate several times The indicator remains on indic
16. voltage models can also accommodate a single RJ 45 10BaseT network connector NOTE DO NOT connect any network equipment to the 230V models only telephone or fax modem protection is available for 230V models l Connect the input connector of the equipment you are protecting to the jack labeled IN 2 Connect the output connector to the jack labeled OUT Powerware 3110 User s Guide RevB www powerware com 7 Features 8 Powerware 3110 User s Guide RevB www powerware com e J a ssa Jg Ps sues CHAPTER 3 UPS MAINTENANCE This section explains how to Care for the UPS and batteries Replace the batteries Recycle used batteries UPS and Battery Care For the best preventive maintenance keep the area around the UPS clean and dust free If the atmosphere is very dusty clean the outside of the system with a vacuum cleaner For full battery life keep the UPS at an ambient temperature of 25 C 77 F Storing the UPS If you store the UPS for a long period recharge the battery every 6 months by plugging the UPS into a power outlet Replacing Batteries Before replacing the battery make sure that you read the safety information below PAN Batteries can present a risk of electrical shock or burn from high short circuit current The following precautions should be observed 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Do not lay tools or m