Contents
1. 13 18 8 FH sasa 14 14 UPSH O mM mai 15 15 TMU FA aaa aaa V0 Tte HUGE El aasa BN 1 INTRODUCTION The product is line interactive UPS with the newest technology and powerful function The LINE INTERACTIVE ups is with AVR function allows input voltage range from 75 to 125 including on line voltage boost up amp buck down An ideal protection equipment for critical connected loads It is based on microprocessor controls with utility power connected the charging is ongoing no need to switch ON the UPS and at back up mode UPS can be automatically turned OFF if none of the connected loads is operating to save the battery energy The indicator will be ON when battery needs replacement and a cyclic self testing function is included in order to verify both the operation of the UPS and the condition of the battery In addition This UPS provides advanced single telephone line or modem surge suppression through the modular connectors on the back panel The LINE INTERACTIVE UPS and UPSMON monitoring software optional kits makes your computer operate intelligent and provides you with the ability of perfect protection of your critical devices Note There is no guarantee that interference to radio TV will not occur in a particular installation If this UPS causes interference to radio or television reception which can be determined by turning the UPS off and on the user is encouraged to try to correct the interference by one or mor
2. Back Up pate oe Low Rapid beeping sound about 1 824Hz Overload Continue beeping sound INTERFACE RS 232 Bi directional communication port for xxxAP models only Interface CONFORMANCE cUL TUV CE meet FCC Surges Meet IEEE 587 standard ENVIRONMENT Ambient 6 000 meters max elevation 0 95 miany non condensing operation 0 48 deg C Audible noise lt 40dBA 1 meter from surface Bo T 15000 meters max elevation Bi a 1997 Powercom Co Ltd All right Reserved All trademarks are property of their respective owners Specifications subject to change without notice
3. use the UPS as a master on off switch make sure all of the loads are switched on Caution Never connect a laser printer or plotter to the UPS with other computer equipment A laser printer or plotter periodically draws significantly more power than when idle and may overload the UPS 4 6 Connect the telephone modem lines 425AP 525AP 625AP models only Connect a single line telephone or a modem line into the telephone modem surge protection sockets on the back of the UPS The RJ 45 RJ 11 modular sockets accept standard single line telephone connections This connection will require another length of telephone cable supplied Note This connection is optional li is not necessary to use this UPS Caution The telephone line current limiting feature could be rendered inoperable if improperly installed Make sure that the telephone line from the wall is plugged into the connector marked IN and the device to be protected telephone modem etc is plugged into the connector marked OUT Caution This surge protection device is for indoor use only and never install telephone wiring during a lightning storm 5 Operation 5 1 Switch on With the UPS plugged in press and hold the on off test silence button more than 1 second until LINE NORMAL LED lit to switch the ups on The UPS will perform self testing each time when it is switched on Note When switched off the UPS maintains the battery charge and will respond to
4. Uninterruptible Power System Line Interactive UPS 325 A 425A 525A 625A Line Interactive Network UPS 425AP 525AP 625AP USER S MANUAL Important safety instructions Thank you for selecting this uninterruptible power system UPS It provides you with better protection for connected equipment Please read this manual This manual provides safety installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question Please save or recycle the packaging materials The UPS s shipping materials were designing with great care to provide protection from transportation related damage These materials are invaluable if you ever have to return the UPS for service Damage sustained during transit is not covered under the warranty Table of contents 1 Introduction m a aaa 1 2 Gate ty saaan na 3 Presentation Front Panel aaa 3 Rear Panes ANA 4 4 Installation aa 5 5 Operati ON wwe mama 7 6 A Wain a aaa a 8 7 Software Options 9 8 Computer Interface Port 10 9 Battery replacement 11 10 Troubleshooting 12 TI SO Fa OO iadd naa aa 12 12 Specifications
5. both RS 232 and relay signal to support NOVELL UNIX DOS WINDOWS and other operating systems 3 6 OUTPUT POWER RECEPTACLES 3 7 AC INPUT POWER RECEPTACLE 3 8 TEL MODEM SURGE PROTECTION 425AP 525AP 625AP models only Surge protection for telephone and modem line to have the complete safety connection for INTERNET service 4 Installation 4 0 Inspection Inspect the UPS upon receipt The packaging is recyclable save it for reuse or dispose of it properly 4 1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust Do not operate the UPS where the temperature and humidity is outside the specified limits 4 2 Connect Computer Interface 425AP 525AP 625AP models only UPSMON or other power management software and an interface kits can be used with this UPS Use only kits supplied or approved by the manufacturer If used connect the interface cable to the 9 pin computer interface port on the back panel of the UPS Note Computer interface connection is optional The UPS works properly without a computer interface connection 4 3 Connect to Utility Connect the AC input power connector to utility power to power up the UPS 4 4 Charge the battery The UPS charges its battery whenever it is connected to utility power For best results charge the battery for 4 hours in the initial use 4 5 Connect the loads Plug the loads into the output connectors on the rear of the UPS To
6. commands received through the computer interface port 5 2 Switch off By pressing and hold the on off test silence button more than 3 seconds until the LINE NORMAL or BACK UP LED off 5 3 SELF TEST Use the self test to verify both the operation of the UPS and the condition of the battery In normal utility power push the on off test silence button less than 1 second and UPS performs a self test function During the self test the UPS operates a back up mode Note During the self test the UPS briefly operates the loads on battery the on battery LED comes on If the UPS passes the self test it returns to on line operation The on battery LED does off and the on line LED goes on steady If the UPS fails the self test it immediately returns to on line operation and lights the replace battery LED The loads are not affected Recharge the battery overnight and perform the self test again If the replace battery LED is still on ask our nearest dealer to replace battery 5 4 SILENCE In BACK UP mode push on off test silence less than 1 second to silence the audible alarm The function is void when under condition of LOW BATTERY or OVERLOAD Note At back up mode UPS can be automatically turned off if none of the connected loads is operating 6 Alarm 6 1 BACK UP slow alarm When in BACK UP mode the YELLOW LED illuminates and the UPS sounds an audible alarm The alarm stops when the UPS returns to LINE NORMAL operat
7. e of following measures connect the equipment to an outlet on a circuit different from that to which the receiver is connected increase the separation between the equipment and the receiver reorient the receiving antenna 2 Safety CAUTION To reduce the risk of electric shock disconnect the UPS from the mains supply before installing a computer interface signal cable Reconnect the power cord only after signaling interconnections have been made eThe internal energy source the battery cannot be de energized by the user The output may be energized when the unit is not connected to a mains supply eThe right way to de energize the UPS properly in an emergency is to move the I O switch to the OFF position and disconnect the power cord from the mains supply The socket outlet shall be installed near the equipment and easily accessible itiention hazardous through electric shock Also with disconnection of this unit the main hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole when maintenance of service work inside the UPS is considered e Do not dispose of batteries in a fire the battery may explore e Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when wo
8. ion Press the on off test silence button during on battery alarms to stop the beeping 6 2 LOW BATTERY rapid alarm In BACK UP mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE NORMAL operation 6 3 OVERLOAD continuous alarm When the UPS is overloaded the connected loads exceed the maximum rated capacity the UPS emits continuous alarm to warn a overload condition Disconnect nonessential load equipment from UPS to eliminate the overload 7 Software options 7 4 UPSMON Software The UPSMON software is applied standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a computer in the event of power failure Moreover UPSMON displays all the diagnostic symptoms on monitor such as Voltage Frequency Battery level and so on The software is available for DOS Windows 3 1x Windows 95 amp Windows NT V3 5 or later 7 2 Interface Kits A series of interface kits is available for operation systems that provide UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize The interface cable at UPS side must be connected to REMOTE PORT at computer side can be either COM 1 or COM 2 The other installation instructions and powerful features please refer to READ ME file Caution Use only factor
9. ools with insulated handles 8 Place your new battery in the same position direction and reconnect the wires red wire position and black wire negative 9 Please follow steps 5 4 and 3 in that order to reconnect the entire unit 10 Please follow manual instructions in order to properly reconnect your equipment 10 Troubleshooting PROBLEM POSSIBLE CAUSE ACTION TO TAKE On off test silence Press the on off test silence button not pushed or button more than 1 second push too short Battery voltage less than Recharge the ups at least 4 hours 10V PCB failure Replace the PCB call for service Load less than 20W at Normal condition battery mode Replug the power cord AC FUSE burn out Replace the AC fuse low or black out Back up time PCB failure Replace PCB call for service Remove the noncritical loads RED LED light Battery failure Replace battery call for service 11 Storage 10 1 Storage conditions Store the UPS covered and upright in a cool dry location with its battery fully charged Before storing charger the UPS for at least 4 hours Remove any accessories in the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary draining the battery 10 2 Extended storage During extended storage in environments where the ambient temperature is 15 to 30 C 5 to 86 F charge the UPS s battery every 6 months During extended storage in environments
10. rking on batteries Remove watches rings or other metal objects Use tools with insulated handles Caution Risk of electric shock hazardous live parts inside this unit are energized from the battery supply even when the input AC power is connected Caution Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Warning To reduce the risk of fire replace only with the same type and rating of fuse Warning To reduce the risk of fire or electric shock install in temperature and humidity controlled indoor area of conductive contaminants 3 Presentation FRONT PANEL 3 1 REPLACE BATTERY indicator RED LED The LED illuminates when the UPS s battery is no longer useful and must be replaced Note When replace battery disconnect the utility power then open the case and take notice of the battery s polarity while install the new battery to avoid short 3 2 BACK UP indicator YELLOW LED The LED illuminates when the UPS is supplying battery power to the loads 3 3 LINE NORMAL indicator GREEN LED The LED illuminates when the line input voltage is normal 3 4 ON OFF TEST SILENCE button Press the button more than 3 seconds to turn the UPS on or off press the button less than 1 second to activate the UPS s self testing or silence the back up alarm REAR PANEL 3 5 COMPUTER INTERFACE 425AP 525AP 625AP models only Provide
11. where the ambient temperature is 30 to 45 C 86 to 113 F charge the UPS s battery every 3 months 12 Specifications INPUT 50 or 60Hz 5 auto sensing OUTPUT Voltage Simulated sine wave at Line Input 5 on battery Frequency 50 or 60Hz 0 5 on battery Voltage AVR automatically increase output voltage 15 above input Regulation voltage if 9 to 25 of nominal AVR decrease output voltage AVR 13 below input voltage if 9 to 25 of nominal 2 4 milliseconds including detection time PROTECTION Spike Protection 320 joules 2ms and FILTERING EMI RFI filter 10dB at15MHz 50dB at 30MHz for xxxAP models only Overload UPS automatic shutdown if overload exceeds 110 of nominal at Protection 60 second and 130 at 3 seconds Unit Input Fuse for overload amp short circuit protection 10Baase T Network UTP RJ 45 compatible jacks Cable Port for xxxAp models onl Short Circuit UPS output cut off immediately or input fuse protection BATTERY Type Sealed maintenance free lead acid 4 hours to 90 of full capacity Recharge Time Automatic self test amp discharge protection replace battery indicator Back up Time 10 30 minutes depending on computer load PHYSICAL Na Weight 4 7 10 4 5 8 12 8 6 2 13 7 6 5 14 3 q lbs Shipping Weight 5 0 11 0 6 1 13 4 6 5 14 3 6 9 15 2 a mm 97x260x135 97x320x135 Te Input Inlet IEC 320 power inlet ALARM Battery Slow beeping sound about 0 47Hz
12. y supplied or authorized UPS monitoring cable 8 Computer Interface Port The computer interface port has the following characteristics D SUB 9 Pin Female Connector Cantacts Low Battery Normally 9 Q Mains Failure Open T a UPS Shut Down or SL 232 TD Pin 3 AS232 RD Pin 2 RS232 RTS Pin 7 AS 232 DTR Pin 4 B No Connection Pin Number 9 Battery Replacement Your battery should run any where from 3 5 years before eve needing to be replaced Please follow the instructions below for easy battery replacement 1 Unplug unit from AC power source and disconnect all connected equipment 2 Disconnect AC power cord from unit 3 Turn unit upside down and using a phillips screw driver unscrew the 4 screws holding the top of the unit to the bottom Put screws in a safe place for reconnection 4 Holding the top together firmly with the bottom turn the entire unit right side up 5 Carefully lift top cover off and place to the side The connecting wires and electronics will be exposed Be careful not to touch any inner components when changing the battery 6 Remove the 2 connecting wires from the battery 7 You can now easily remove the battery from the unit Caution Do not dispose of battery in fire Caution Do not attempt to open the battery Caution The following precautions should be taken when replacing the battery e remove watches rings etc euse t