Home
Polar G596 User's Manual
Contents
1. REFRIGERATION 4 Stainless Steel Counter Refrigerators Freezers Models G596 G597 G598 G599 G600 G601 G621 G622 U636 U637 U638 Table Of Contents Safety Tips Product Description Introduction Pack Contents Installation Fitting the Shelves amp Floor Guards Operation Storing Food Turn On Control Panel Lock Unlock the Control Panel Enter the Parameter Menu Manual Defrost Cleaning Care amp Maintenance Cleaning the Condenser Disposal Troubleshooting Error Messages Electrical Wiring Compliance Safety Tips e Position on a flat stable surface e A service agent qualified technician should carry out installation and any repairs if required Do not remove any components or service panels on this product e Consult Local and National Standards to comply with the following e Health and Safety at Work Legislation s BS EN Codes of Practice e Fire Precautions e IEE Wiring Regulations e Building Regulations e DO NOT use jet pressure washers to clean the appliance e DO NOT use the appliance outside e DO NOT use this appliance to store medical supplies e DO NOT use electrical appliances inside the appliance e g heaters ice cream makers etc e DO NOT stand or support yourself on the base drawers or doors e DO NOT allow oil or fat to come into contact with the plastic components or door seal Clean immediately if contact occurs e Bottles that contain a high pe
2. plug is to be connected to a suitable mains socket POLAR appliances are wired as follows e Live wire coloured brown to terminal marked L e Neutral wire coloured blue to terminal marked N e Earth wire coloured green yellow to terminal marked E All POLAR appliances must be earthed using a dedicated earthing circuit If in doubt consult a qualified electrician Electrical isolation points must be kept clear of any obstructions In the event of any emergency disconnection being required they must be readily accessible Compliance POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approved to carry the following symbol Notes POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB
3. standby mode When parameters are being set the Setpoint LED will flash on the display Operating temperature Set the operating temperature of the appliance 2 C to 10 C de Temperature The Temperature Differential is the allowed temperature difference above and below the 0 to 20 C Differential operating temperature before the compressor starts cuts off 40 C Temperature Range Set the minimum d3 and maximum d4 temperatures that the appliance can fluctuate between le 5 C Compressor Activation Time Intervals Maximum Temperature Set an alarm to sound if the temperature inside the appliance exceeds the set operating 0 C 50 C Differential Alarm temperature by a specified amount Temperature DE geld f l Differential Alarm Delay Set a delay before the temperature differential alarm is triggered 0 99 minutes Defrost Cycle Time Set the time between each defrost cycle 1 999 hours Intervals Set the maximum length of the defrost cycle Note The defrost duration can be overridden by parameter d10 below if the cut off temperature is reached before the end of the defrost duration Defrost Cut off Set the defrost cut off temperature 45 C to 50 C Temperature Additional Cut off Set an additional amount of defrost time after the defrost cut off point has been reached if Defrost Period required OS Delayed Actual Set the length of time the inner temperature of the appliance before defrost started is od minitas Temper
4. to the a more suitable location too high low condenser is being interrupted Ambient temperature is too Increase ventilation or high move appliance to a cooler position Unsuitable foodstuffs are being Remove any excessive hot foodstuffs or blockages to the fan stored in the appliance Reduce the amount of food stored in the appliance Appliance is overloaded The appliance is not properly levelled Adjust the screw feet to level the appliance if applicable The discharge outlet is blocked Clear the discharge The appliance outlet is leaking water Movement of water to the drain Clear the floor of the is obstructed appliance if applicable The water container is Call POLAR agent or damaged qualified Technician The drip tray is full Empty the drip tray if applicable Loose nut screw Check and tighten all nuts and screws The appliance has not been Check installation installed in a level or stable position and change if position necessary The appliance is unusually loud Error Messages The following table details the cause and subsequent response of the appliance to errors Error Message Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician The inner temperature exceeds Display flashes the set maximum temperature Alternating error message and current temperature Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician Shor
5. ature Display displayed for after a defrost cycle has finished Compressor On Off l n During Defrost Turn the Compressor On or Off during the defrost cycle On 1 or Off u r B Set the amount of time the compressor remains turned Off after a defrost cycle reducing the 2 Evaporator Drying Time amount of frost build up 0 99 minutes OFF Should there be any variance between measured and actual temperature the measured o A Temperature er temperature can be offset to compensate oe e Unit of Measurement Set whether the temperature is displayed in Centigrade or Fahrenheit Centigrade Compressor runs Remains Off until fault fixed D Runs intermittently with Enter the minimum time interval between the compressor turning off after turning on 0 999 seconds Lus dH d5 di Maximum Defrost 0 999 minutes Duration o ci did d 3 IH d or Fahrenheit Co Compressor Operanon Set whether the compressor runs or remains Off during a temperature probe failure During Probe Failure II u parameters d and 25 d d4 Se on Set the length of time the compressor runs during a temperature probe failure 1 99 minutes 05 ee Or Set the length of time the compressor remains Off during a temperature probe failure 1 99 minutes J4 I nitial Defrost After Set whether the appliance starts a defrost cycle 10 minutes after startup or after the time Begins 10 minutes after startup 7 Startup programmed in paramete
6. ds 1 per door e Shelves 1 per door POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your POLAR dealer immediately UK Installation Note If the unit has not been stored in an upright position let it stand upright for approximately 12 hours before operation If in doubt allow to stand I Remove the appliance from the packaging Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces 2 Maintain a distance of 20cm 7 inches between the unit and walls or other objects for ventilation Increase this distance if the obstacle is a heat source Note Before using the appliance for the first time clean the shelves and interior with soapy water 3 Setthe brakes on the castors to keep the appliance in position OR Level the appliance by adjusting the screw feet Fitting the Shelves amp Floor Guards I Place one set of shelf guides on either side of the cabinet at the desired height 2 Slide the shelf into place 3 Repeat for the remaining shelves 4 Place the floor guards on the floor of the cabinet ensuring the flat side is clear of the floor O Note This is vital for ensuring correct drainage of condensation Operation Storing Food To get the best results from your POLAR appliance follow these ins
7. ppliance POLAR recommend that a POLAR agent or qualified technician clean the condenser Disposal EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses metal and plastic components Consult your local waste collection authority regarding disposal of your appliance Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally Alternatively call the POLAR helpline for details of national disposal companies within the EU UK Troubleshooting If your POLAR appliance develops a fault please check the following table before making a call to the Helpline or your POLAR retailer The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician Too Too much ice on the condenser ice on the condenser Defrost the Defrost the appliance E blocked with dust dsl POLAR agent or qualified Technician Doors are not shut properly Check doors are shut and seals are not damaged The appliance is not working The appliance turns on but the Appliance is located near a heat Move the refrigerator to temperature IS source or air flow
8. r dB Defrost Cycle Time Intervals U or when programmed Jp Minimum Temperature Set the display to flash should the inner temperature of the appliance drop beyond a specified o 1 C to 50 C Alarm point from the programmed operating temperature Manual Defrost 2 The defrost cycle will start immediately and the Defrost LED illuminates l l The defrost will last a maximum of 30 minutes The appliance will automatically run a defrost cycle every six hours Note Starting a manual defrost also resets the automatic Note The cycle starts from the time the appliance is initially defrost timer powered up l 3 The next automatic defrost will start six hours after the manual defrost To manually defrost the appliance has finished Press and hold the DEFROST button for 5 seconds Cleaning Care amp Maintenance e Switch off and disconnect from the power supply before cleaning e Clean the interior of the appliance as often as possible e Do not use abrasive cleaning agents These can leave harmful residues e Clean the door seal with water only e Always wipe dry after cleaning e Do not allow water used in cleaning to run through the drain hole into the evaporation pan e Take care when cleaning the rear of the appliance Sharp edges can cut e A POLAR agent or qualified technician must carry out repairs if required Cleaning the Condenser Periodically cleaning the condenser can extend the life of the a
9. rcentage of alcohol must be sealed and placed vertically in the refrigerator e Always carry store and handle the appliance in a vertical position and move by holding the base of the appliance e Always switch off and disconnect the power supply to the unit before cleaning e Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities e If the power cord is damaged it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard Product Description G596 POLAR 282 litre 2 Door Counter Refrigerator G597 POLAR 417 litre 3 Door Counter Refrigerator G598 POLAR 563 litre 4 Door Counter Refrigerator G599 POLAR 282 litre 2 Door Counter Freezer G600 POLAR 417 litre 3 Door Counter Freezer G601 POLAR 563 litre 4 Door Counter Freezer G621 POLAR 417 litre 3 Glass Door Counter Refrigerator G622 POLAR 368 litre 3 Door Counter Refrigerator U636 POLAR 240 litre 2 Door Counter Refrigerator U637 POLAR 240 litre 1 Door 2 Drawer Counter Refrigerator U638 POLAR 240 litre 4 Drawer Counter Refrigerator Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product Pack Contents The following is included e POLAR Refrigerator or Freezer e Instruction manual e Shelf guides 2 per door e Floor guar
10. t circuit or interruption of Compressor ps as specified by Display flashes B the thermostat probe input line parameter lali Display flashes Defrost as specified by parameters dH and d9 the evaporator probe input line HLA alla temperature greater tian dol Call POLAR agent or qualified Technician 90 C Alternating error message and current temperature LLA nner PI Ea ADO MESES Call POLAR agent or qualified Technician 45 C Alternating error message and current temperature The alarm message will end when the alarm trigger is no longer present except PF1 and PF2 that require the appliance to be turned Off then On again Technical Specifications Temperature Capacity Dimensions 230V 50Hz 50Hz NOS 1 ASA 2 2 C to 10 C to 10 C R134a 1342 240g 850x 1360 x 700 x 1360 x 700 CEE ear avs aar ik rome ar maer taser ar CEE om A ze wen MEL mm ETE t E E mm ceo 2907506 or aaa t am O mm The inner temperature exceeds Display flashes the set minimum temperature Alternating error message and current temperature eenn awsome 00w EE mm 155 CM EN EA a ez ome Mw mn Zn mj ene 107 CN wm mm E mj mm a m U637 230V 50Hz 250W A 2 C to 10 C 240 R134a 165g 850 x 900 x 700 U638 230V 50Hz 250W 2 C to 10 C R134a 165g 850 x 900 x 700 Electrical Wiring POLAR appliances are supplied with a 3 pin moulded BS1363 plug and lead with a 13 amp fuse as standard The
11. tructions e Only store foodstuffs in the appliance when it has reached the correct operating temperature e Do not place uncovered hot food or liquid inside the appliance e Wrap or cover food where possible e Do not obstruct the fans inside the appliance e Avoid opening the doors for prolonged periods of time Turn On I Close the doors drawers of the appliance 2 Ensure the power switch is set to O and turn on at the socket 3 Switch on the Power I The current temperature within the appliance is displayed Control Panel DEFROST LED SETPOINT LED illuminates when defrost is activated flashes when parameters are being UP button E DEFROST button Por e rek31e ektron DOWN button SET button Display Panel Lock Unlock the Control Panel To lock the control panel I Press and hold the UP 4 and DOWN E buttons simultaneously for 10 seconds 2 PoF flashes on the display and the keyboard is locked UO To unlock the control panel Enter the Parameter Menu I Press and hold the UP 2 and DOWN 6 buttons simultaneously for 10 1 Unlock the control panel if locked seconds 2 Press and hold the SET GEN button until d l flashes on the display 2 Pon flashes on the display and the keyboard is unlocked 3 Press the SET GEN button repeatedly to scroll to the desired parameter Note see below If a button is not pressed for 10 seconds while using the control panel it times out and reverts to