1. Model ISW 621T ISW 621TS15 Hardware Specification Ports 4 x 10 100Base TX Auto negotiation Auto MDI MDI X 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 cable 100meters max Port 2 x 100Base FX Fiber 50 125um or 62 5 125um fiber 9 125um fiber Optical Multi mode Single mode 15km Dimensions WxDxH Weight 4429 12 48 VDC Redundant power with polarity reverse protection function PO Cable 135mm x 97mm x 32mm Power Requirement Power Consumption Dissipation Installation DIN rail kit and wall mount ear 11 6 Watts 40BTU Switch Specification Switch Processing Gesner Scheme Address Table Buffer Mbit O CONTO Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Switch Fabric 1 2Gbps Throughput M 4B Packet Per Second 0 89Mpps 64Bytes Standards Conformance IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex flow control Operating 40 75 Degree C P Storage 40 85 Degree C Humidity Operating Operating 5 to 90 Storage 5 to 90 Non condensing oeio FCC Part 15 Class A CE Compliance Standards Compliance g12 2 INSTALLATION This section describes the functionalities of the Industrial Fast Ethernet Switch s components and guides how to install it on the desktop Basic knowledge of networking is assumed Please read this chapter completel
2. D a 209 20 MA M A 10 100 A 10 100 Y LNK ACT ISW 5 1 1 Y LNK ACT ISW 621 Figure 2 1 ISW 511 ISW 511515 front panel Figure 2 2 ISW 621 ISW 621S15 front panel 14 JR JD P1 P2 FAULT e BNUIdO zZz a 20 ve A 10 100 A 10 100 vink acr ISW 511T vink act ISW 621T Figure 2 3 ISW 511T ISW 511TS15 front panel Figure 2 4 ISW 621T ISW 621TS15 front panel 15 2 1 2 LED Indicators P1 Lit indicate the power 1 has power P2 Lit indicate the power 2 has power FAULT Lit an the either power 1 or power 2 has no Fiber Lit indicate the Fiber port is successfully Green connecting to the network at Optical 100Mbps Lit indicate the Switch is successfully connecting to the network at 100Mbps Off indicate that the Switch is successfully connecting to the network at 10Mbps 10 100 Green Copper Fiber Lit indicate the link through that port is Optical successfully established LNK ACT Green Blink indicate that the Switch is actively copper sending or receiving data over that Copper port 2 1 3 Switch Upper Panel The upper panel of the Industrial Fast Ethernet Switch consist one terminal block connector within two DC power inputs Figure 2 5 shows the upper panel of the Industrial Fast Ethernet Switch O O O O ooo0o0e000 010 0 0 0 O O O O V1 Vi yy V2 V2 Input L L 1 DCi2 48v PWR1 Fault PWR2 Figure 2 5 Industrial Fast Ethernet S
3. 1 Package Contents s sssssssrenassnssrrrnannnannnnsssrnsrnnnnnnnnasnnnnnne 6 1 2 How to Use This Manual Luvuuqssgasmmmisememmmnimmesimiv 6 1 3 PF dde FU sonsa Aa 7 Ed nr IP Ol EEE ENE 7 Layer EE sd 7 Industrial Case Installation ccccccceueeeeeceeeeeeeeeeessueeeneeeens 8 1 4 Product Specifications rarernrrnnrnnennnrnvennnrnnennennnnnnennnnnnennnnn 9 2 AN 13 21 Product DENN s n 13 2 Switch Front PE eden 14 Deda EED ANE orre EAER 16 2 1 3 Switch Upper Panel sssssssssssssrrrrrrnnnnnssrnrrrrrrnnrnrnssrene 16 2 1 4 Wiring the Power Inputs save 17 2 1 5 Wiring the Fault Alarm Contact ssssssssssssssssssssssnsns 18 2 2 Mounting Installation avsa 19 2 2 1 Install DIN Rail Mounting Lasso 19 2 2 2 Wall Mount Plate Mounting sssssssssesssssssssssnssssnssnsns 21 3 APPLICATION ee 22 Mb Sveve 23 4 SWITCH OPERATIONS 24 Fl Address TIDE use ATEREA 24 EE EN 24 23 Forwarding amp Filtering iantuasisantxnewnyiecvaettrrrscnrectpantanesacaneets 24 4 SEOPe ANC FORWANG aoaeiaa aR 24 4 5 ATEN eee 25 5 TROUBLESHOOTING nn ne nee eee tee ere mt reer 26 APPENDIX A NETWORKING CONNECTION c ccccecceeeeeeeeeeaeeenaeenaas 27 A 1 Switch s RJ 45 Pin Assignments raunannnvnnnvrnnvennnennnennnennnnenne 27 A 2 RJ 45 cable Pin Assignments cccseccesceseseestenseeenceenaceeanteas 27 1 INTRODUCTION 1 1 Package Contents Check the contents of your package for following parts e Industrial
4. 4 Port 10 100Mbps 1 2 100FX Fiber Port Industrial Fast Ethernet Switch ISW 511 ISW 621Series User s Manual Trademarks Copyright PLANET Technology Corp 2009 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and f
5. Fast Ethernet Switch x 1 e User s Manual x 1 e DIN Rail Kit x 1 e Wall Mount Kit x 1 If any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 How to Use This Manual This Industrial Fast Ethernet Switch User Manual is structured as follows Chapter 2 Installation The chapter explains the feature functionality and the physical installation of the Industrial Fast Ethernet Switch Chapter 3 Application The chapter explains the Industrial Fast Ethernet Switch application Chapter 4 Switch operation The chapter explains the Industrial Fast Ethernet Switch transmit operation Chapter 5 Troubleshooting The chapter explains the troubleshooting of the Industrial Fast Ethernet Switch Appendix A This chapter contains cable information of the Industrial Fast Ethernet Switch 1 3 Product Features Physical Port ISW 511 Multi 2km ISW 511T mode iSW 511515 1 x 100Base FX am mode ISW 511TS15 4 x 10 100Base TX ISW 621 Multi 2km ISW 621T mode 2 x 100Base FX ISW 621S15 aaie Single iskm ISW 621TS15 mode Layer 2 Features o Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX o Supports Auto negotiation and 10 100Mbps half full duplex mode for each copper port o High performance store and forward a
6. ar Switch Specification Switch Processing ee Te Scheme Address Table 1Mbit Gore Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Switch Fabric 1Gbps Throughput Packet Per Second 0 74Mpps 64Bytes Standards Conformance IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex flow control Teenie Operating 10 60 Degree C P Storage 40 85 Degree C Humidity Operating Operating 5 to 90 Storage 5 to 90 Non condensing Regulation FCC Part 15 Class A CE Compliance Standards Compliance Model ISW 511T ISW 511TS15 Hardware Specification Ports 4 x 10 100Base TX Auto negotiation Auto MDI MDI X 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 cable 100meters max Port 1 x 100Base FX Fiber Cable 50 125um or 62 5 125um fiber 9 125um fiber Optical Mode Multi mode Single mode Distance 2km 15km Dimensions W x D x H Weight 436g Power Requirement in 4 Redundant power with polarity reverse protection function Power Consumption Mer OMSAMPR T 9 1 Watts 31BTU Dissipation Installation DIN rail kit and wall mount ear Switch Specification Switch Processing Ge Scheme Address Table 1Mbit Fini Control Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Switch Fabric 1Gbps Throughput Packet Per Second 0 74Mpps 64Bytes Standards Confo
7. ast Ethernet Switch is implemented with an address table This address table composed of many entries Each entry is used to store the address information of some node in network including MAC address port no etc This information comes from the learning process of Industrial Fast Ethernet Switch 4 2 Learning When one packet comes in from any port The Industrial Fast Ethernet Switch will record the source address port no And the other related information in address table This information will be used to decide either forwarding or filtering for future packets 4 3 Forwarding amp Filtering When one packet comes from some port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address learning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it connected If found and the destination address is located at different port from this packet comes in the Industrial Fast Ethernet Switch will forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in then this packet will be filtered Thereby increasing the network throughput and ava
8. ilability 4 4 Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Industrial Switch stores the incoming frame in an internal buffer do the complete error checking before transmission fi 24 Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Industrial Fast Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and availability However the switch is most commonly used to segment existing hubs which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Industrial Fast Ethernet Switch performs Store and Forward therefore no error
9. ke connections to it Please read the following topics and perform the procedures in the order being presented In the installation steps below this Manual use IGS 801 PLANET 8 Port Industrial Gigabit Switch as the example However the steps for PLANET Industrial Switch amp Industrial Media Converter are similar 2 2 1 Install DIN Rail Mounting The DIN Rail is screwed on the Industrial Fast Ethernet Switch when out of factory When need to replace the wall mount application with DIN Rail application on Industrial Fast Ethernet Switch please refer to following figures to screw the DIN Rail on the Industrial Fast Ethernet Switch To hang the Industrial Fast Ethernet Switch follow the below steps Step 1 screw the DIN Rail on the Industrial Fast Ethernet Switch 19 amp _ Step 3 Check the DIN Rail is tightly on the track Step 4 Please refer to following procedures to remove the Industrial Fast Ethernet Switch from the track Step 5 Lightly press the button of DIN Rail for remove it from the track 4 20 2 2 2 Wall Mount Plate Mounting To install the Industrial Fast Ethernet Switch on the wall please follows the instructions described below Step 1 Remove the DIN Rail from the Industrial Fast Ethernet Switch loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the Industrial Fast Ethernet Switch Step 3 Use the screws to screw the wall m
10. l track or wall please refer to the Mounting Installation section Step 4 Power on the Industrial Fast Ethernet Switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial Fast Ethernet Switch will light up Please refer to the LED Indicators section for meaning of LED lights Step 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 Cable Step 7 Insert fiber cable from the ISW 511 621 series to the fiber network TX RX must be paired at both ends The optical port LED on the Industrial Fast Ethernet Switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning Step 8 When all connections are all set and LED lights all show in normal the installation is complete 23 E _ 4 SWITCH OPERATION 4 1 Address Table The Industrial F
11. n 7 White Brown 8 Brown 8 Brown Cross Over Cable SIDE 1 SIDE 2 12345678 SIDE1 1 White Orange 1 White Green 2 Orange 2 Green 3 White Green 3 White Orange 4 Blue 4 Blue 5 White Blue 5 White Blue 12345678 SIDE2 6 Green 6 Orange 7 White Brown 7 White Brown 8 Brown 8 Brown Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 28
12. ound to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human K health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision PLANET 4 Port 10 100Mbps 1 2 100FX Fiber Port Industrial Fast Ethernet Switch User s Manual For Models ISW 511 ISW 621 Series Revision 1 0 February 2009 Part No EM ISW 511 621 v1 0 2350 AH0150 000 TABLE OF CONTENTS 1s INTRODUCTION vr 6 1
13. ount plate on the Industrial Fast Ethernet Switch Step 4 Use the hook holes at the corners of the wall mount plate to hang the Industrial Fast Ethernet Switch on the wall Step 5 To remove the wall mount plate reverse steps above 21 _ 3 APPLICATION In this paragraph we will describe how to install Industrial Fast Ethernet Switch and the installation points for the attention ISW 511S15 ISW 511S15 ICA 525 Harbor Robot LO eee ee ee 100Base TX UTP I I f 100Base FX Fiber optic I DI DO I Factory Fiber Switch Ye T ISW 621S15 og ISW 621S15 1CS 2100 i af S amp S jams V g q Serial over Ethernet device ICA 601 7 f lt 5 K ICS 2100 JE Control Center Maintenance Shop fee SSE se ce a 100Base TX UTP I I I 100Base FX Fiber optic I Subway 1 ob 22 Installation Steps Step 1 Unpack the Industrial Fast Ethernet Switch Step 2 Check the DIN Rail is screwed on the Industrial Fast Ethernet Switch Please refer to DIN Rail Mounting section for DIN Rail installation If the DIN Rail is not screwed on the Industrial Fast Ethernet Switch If you want to wall mount the Industrial Fast Ethernet Switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation Step 3 To hang the Industrial Fast Ethernet Switch on the DIN Rai
14. packets occur More reliably it reduces the re transmission rate No packet loss will occur 4 5 Auto negotiation The STP ports on the Industrial Fast Ethernet Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 25 E 5 TROUBLESHOOTING This chapter contains information to help you solve issues If the Industrial Fast Ethernet Switch is not functioning properly make sure the Industrial Fast Ethernet Switch was set up according to instructions in this manual The per port LED is not lit Solution Check the cable connection of the Industrial Fast Ethernet Switch Performance is bad Solution Check the speed duplex mode of the partner device The Industrial Fast Ethernet Switch is run at Auto negotiation mode and if the partner is set to half duplex then the performance will be poor Per port LED is lit but the traffic is irregular Solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why the Industrial Fast Ethernet S
15. rchitecture broadcast storm control runt CRC filtering eliminates erroneous packets to optimize the network bandwidth o Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex o Backplane Switching Fabric ISW 511 Series 1Gbps ISW 621 Series 1 2Gbps o Integrated address look up engine support 2K absolute MAC addresses o 1Mbit on chip frame buffer on ISW 511 ISW 621 Series o Automatic address learning and address aging 7 o CSMA CD Protocol Industrial Case Installation o IP 30 Metal case Protection o DIN Rail and Wall Mount Design o 12 to 48V DC redundant power with polarity reverse protect function and connective removable terminal block for master and slave power o 10 to 60 Degree C operation temperature on ISW 511 ISW 511515 ISW 621 ISW 621S15 o 40 to 75 Degree C operation temperature on ISW 511T ISW 511TS15 ISW 621T ISW 621TS15 1 4 Product Specifications Hardware Specification Ports 4 x 10 100Base TX Auto negotiation Auto MDI MDI X Copper 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 cable 100meters max Port 1 x 100Base FX Fiber Optical Dj ene 135mm x 97mm x 32mm Weight 436g Power Requirement ean a Redundant power with polarity reverse protection function Power Consumption E 9 1 Watts 31BTU Dissipation Installation DIN rail kit and wall mount e
16. rmance IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex flow control Operating 40 75 Degree C P Storage 40 85 Degree C Humidity Operating Operating 5 to 90 Storage 5 to 90 Non condensing Regulation FCC Part 15 Class A CE Compliance C sia Cable 135mm x 97mm x 32mm Standards Compliance 110 Hardware Specification 4 x 10 100Base TX Auto negotiation Auto MDI MDI X Copper Cane 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 cable 100meters max 2 x 100Base FX Fiber Optical Mode Single mode Dimensions WxDxH 135mm x 97mm x 32mm Weight 442g Power Requirement Ge d Redundant power with polarity reverse protection function P E 11 6 Watts 40BTU Dissipation Installation DIN rail kit and wall mount ear Switch Specification Switch Processing Ge Scheme Address Table Mbit Back pressure for half duplex ed IEEE 802 3x Pause Frame for full duplex Switch Fabric 1 2Gbps Throughput Packet Per Second 0 89Mpps 64Bytes Standards Conformance IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex flow control eee Operating 10 60 Degree C P Storage 40 85 Degree C Humidity Operating Operating 5 to 90 Storage 5 to 90 Non condensing Regulation FCC Part 15 Class A CE Compliance 11E Standards Compliance
17. witch doesn t connect to the network Solution Check per port LED on the Industrial Fast Ethernet Switch Try another port on the Industrial Fast Ethernet Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on power again Why the Industrial Fast Ethernet Switch doesn t connect to the network Solution Check per port LED on the Industrial Fast Ethernet Switch Try another port on the Industrial Fast Ethernet Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on power again i 26 APPENDIX A NETWORKING CONNECTION A 1 Switch s RJ 45 Pin Assignments 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment MDI MDI X Contact Media Dependant Interface Cross G o e Media Dependant Interface teens EK roe Not used ee re Ti wens Not used A 2 RJ 45 cable Pin Assignments The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection 27 tc SIDE 1 SIDE 2 12345678 SIDE1 1 White Orange 1 White Orange 2 Orange 2 Orange 3 White Green 3 White Green 4 Blue 4 Blue 5 White Blue 5 White Blue 12345678 SIDE 2 6 Green 6 Green 7 White Brow
18. witch upper Panel 2 1 4 Wiring the Power Inputs The 6 contact terminal block connector on the top panel of Industrial Fast Ethernet Switch is used for two DC redundant powers input Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 V1 Vi y V2 V2 Input O O L DC12 48V PWR1 Fault PWR2 V1 V1 V2 V2 2 Tighten the wire clamp screws for preventing the wires from loosing 3 The wire gauge for the terminal block should be in the range between 12 24 AWG 17 E 2 1 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the Industrial Fast Ethernet Switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 2 3 4 5 6 The wire gauge for the terminal block should be in the range between 12 24 AWG Alarm relay circuit accepts up to 30V max 3A currents Industrial Switch The closed circuit will open whenthe failure occurs Ar GS Fault Alarm Contacts 3 amp 4 2 2 Mounting Installation This section describes how to install the Industrial Fast Ethernet Switch and ma
19. y before continuing In the following section the term Industrial Fast Ethernet Switch means the ISW 511 ISW 621 series 2 1 Product Description The PLANET ISW 511 ISW 621 series is 4 Port 10 100Mbps 1 2 100FX Fiber Port Industrial Fast Ethernet Switch with non blocking wire speed performance and new slim type with IP 30 metal shape for easily deployment in Heavy Industrial demanding environments With a 1 1 2Gbps internal switching fabric the Industrial Fast Ethernet Switch can handle extremely large amounts of data in a secure topology linking to a backbone or high capacity servers The Industrial Fast Ethernet Switch has 2K MAC address table and offers wire speed packets transfer performance without risk of packet loss The stable throughput of the device makes it ideal for most Ethernet environments All RJ 45 copper interfaces support 10 100Mbps Auto negotiation for optimal speed detection through RJ 45 Category 5 4 or 3 cables Support standard for Auto MDI MDI X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables The flow control function allows Industrial Fast Ethernet Switch supported routers and servers to directly connect to this device for fast reliable data transfer 13 2 1 1 Switch Front Panel Figure 2 1 amp 2 2 amp 2 3 amp 2 4 shows a front panel of Industrial Fast Ethernet Switch eo 00 P1 P2 FAULT PEN GID