Home

Photogenic Professional Lighting PowerLight 1250 User's Manual

image

Contents

1. Squeeze levers to mount reflector in locked position Punch out hole for Professional plug in umbrella rod flashtube With power switch OFF attach the line cord to the power input connector located on the bottom of the PowerLight and connect it to a grounded wall outlet Turn the power switch ON The READY light will light when the unit has charged to the power level set by the FLASH power control CONTROL PANEL AND BASIC OPERATION WARNING a Aa Do NOT OPERATE WITHOUT Gass LAMP COVER 1 32 1 16 1 8 Wh 1 2 FULL WAE A rl MANUAL RACK O FuLL O o O St o ON OFF 5 SLAVE PowerLight 1250 MADE IN U S A i Power Input The power required to operate the PowerLight 1250 1250DR or 2500DR is 105 to 125 volts AC 60 Hz 10 Amp The power cord has a 125V 10 Amp rating Replacement cords or extension cords rated for less amperage may overheat and should not be used with PowerLights Circuit Protection Circuit protection automatically protects this appliance from excessive damage due to circuit or component failure Operation exceeding the rated cycle of the appliance may cause the fuse to open Always replace fuse with same rating of fuse An additional thermal protector is located inside the PowerLight and may open if th
2. 16 2 panel clamp fit barndoor amp diffuser 16 4 panel barndoor and diffuser 20 Parabolic for portraits feathering flood and fill lighting 65 degree coverage 20 2 panel clamp fit barndoor amp diffuser 24 Parabolic for soft illumination and flood lighting 100 degree coverage Shallow Background reflector rotates to control light for high key amp back lighting Veil Slotted Background reflector for veil and burst lighting effects Deep Conical Background reflector Gel amp Diffuser holder for Deep background reflector Accessory mounting frame for 7 _ reflector 4 panel barndoor frame and diffuser kit for PLO6 R Diffuser available separately 3 amp 5 snoot kit with diffuser and mounting frame Snoots also available separately Fine amp coarse grids with diffuser and mounting frame Grids also available separately Counter weight for PowerLights Used with soft boxes umbrellas and large reflectors Tilting handle for PowerLights Makes an adjustment easier for light direction POWERLIGHT QUICK CHANGE ACCESSORIES UMBRELLAS EC32BC EC45BC EC60BC EC32S EC45S EC60S SOFTBOXES SB12x36 SB24x32 SB36x48 SB48x72 SB22 SB36 OB48 32 White satin flat panel inner umbrella with black blocking outer umbrella 45 White satin flat panel inner umbrella with black blocking outer umbrella 60 White satin flat panel inner umbrella with black blocking outer umbrella 32 S
3. 00 watt seconds slide the FLASH control knob all the way to the right To adjust the PowerLight 1250 to an exact flash power setting use the accessory digital display Ready Light The PowerLight 1250 is fully charged when the READY lamp is on Lowest power 16ws charge time is a maximum of 5 seconds and at full power charge 500 ws time is a maximum of 1 5 seconds The unit may be flashed before fully charged Modeling Light The modeling light has three modes of operation 1 MANUAL adjustment press the MANUAL button LED on adjusts the modeling lamp intensity with the MODEL slide control knob As with flash power minimum setting is full left and maximum setting is full right The MODEL intensity scale corresponds to the FLASH intensity scale measured in f stops 2 TRACK mode causes the modeling lamp intensity to track the FLASH control knob setting The modeling lamp may be set to full intensity at any FLASH control knob position by simply pressing the TRACK SET button a second time you will notice the TRACK SET LED light blink once with the FLASH control knob in the desired position Setting is retained when user returns from another mode 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LED off or ON LED on All mode settings are retained even after the power has been turned off PL1250 Accessories A Digital Display for the flash power setting is availab
4. 174 Reflector Diameter None 71 2 14 16 20 24 Coverage 360 35 40 60 65 145 Full 2333 25000 17500 23333 16333 4200 Half 1167 12500 8750 11667 8167 2100 Quarter 583 6250 4375 5833 4083 1050 Eighth 292 3125 2188 2916 2042 525 Sixteenth 146 1562 1094 1458 1021 262 Thirty Second 73 781 547 729 510 131 GN ASA 100 110 365 305 350 295 150 SPECIFICATIONS PL1250 amp PL1250DR General Flash POW 68 crcske at antenana T Ereta 16 to 500 watt seconds maximum 6 f stops Flash Duration lt c c006 scsccecsecceceiescteeiescvseseats 1 1300 second at Full 1 640 second at 1 32 Recycling time ccceecesceeseeseeseeeeeteeseeeseens 0 5 to 1 5 seconds Power Control scenice nini Full to 1 32 range 6 f stops 0 1 f stop resolution Digital Display Accessory Modeling Light Power cceseseeseereeeees 250 Watt Quartz ESS Modeling Light Control cc eeceeeeseeeeeeees Full to 1 32 range 0 1 f stop resolution Line voltage regulated Tigerin trernen e aa EE ees Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated M in S pplyne nesena 105 125 VAC 60 Hz 10 amp Consumption sen nnec 0 2 amps idling 15 amps charge Voltage Stabilization s s s Plus or minus 0 05 f stop Overload Protection ccceceeeeseeteseeteees Fuse 3AG type 15 Amp SLO BLO Pack agin 9 oora cig ae ett Extruded Aluminum case Weth neess n E EN stad 5 pounds 8 ounces Dimensi
5. 2 Eighth 1375 1396 1396 Sixteenth 688 698 698 Thirty Second 344 349 349 Reflector Diameter None 71 2 14 16 20 24 Coverage 360 35 40 60 65 145 Full 4666 50000 35000 46666 32666 8400 Half 2333 25000 17500 23333 16333 4200 Quarter 1167 12500 8750 11667 8167 2100 Eighth 583 6250 4375 5833 4083 1050 Sixteenth 292 3125 2188 2916 2042 525 Thirty Second 146 1562 1094 1458 1021 262 GN ASA 100 160 515 430 495 415 210 SPECIFICATIONS PL2500DR General Flash sPOWets eare resetest ets 32 to 1000 watt seconds maximum 6 f stops Flash Duration cccceceeseeseeseeeeeteeseeeeeens 1 770 second at Full 1 345 second at 1 32 Recycling time ccceeceeseeseeseeseeeeeteeseeeseens 0 8 to 3 0 seconds Power Control cccceceseseeseeseeseeeteeseeeeeeeees Full to 1 32 range 0 1 f stop resolution Digital Display amp Control Accessory Modeling Light Power cceseseseereeeees 250 Watt Quartz ESS Modeling Light Control 0 ceceeeseereeees Full to 1 32 range 0 1 f stop resolution Line voltage regulated Triggering inini nnne ii Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply w sasiccieeniiiee ei eciinle 105 125 VAC 60 Hz 10 Amp Consumption ccceeseeseesseeseeseeeseeeeeeenseens 0 2 amps idling 15 amps charge Voltage Stabilization s s s Plus or minus 0 05 f stop Overload Protection cecesceeeeteseeteeteens Fuse 3AG
6. Photogenic rofessional lighting POWERLIGHT Operator s Manual PowerLight 1250 PowerLight 1250DR PowerLight 2500DR amp Remote Control Accessories Unit Number Assignment Page 14 PLDIR 2 and PLDIR 1 Remote Digital Display Page 15 PLIRC 1 Infrared Remote Controller Page 16 OPERATOR MANUAL FOR MONOLIGHTS PowerLight 1250 PowerLight 1250DR PowerLight 2500DR OPERATOR MANUAL FOR ACCESSORIES PLDD 1 side display for model PL1250 only PLDC 1 side display manual controller for DR models PLDIR 2 side display amp IR receiver for DR models PLIRC 1 hand held remote control for DR models Thank you for selecting the Photogenic Professional PowerLight PL2 series The PL2 series incorporates the newest electronic components providing improved lighting control power setting repeatability and expanded functions These products are built for the demanding operational needs of the professional photographer and it is our expectation that your PowerLight and PowerLight accessories will provide you with years of dependable service With this new PL2 series optional accessories include remote power displays manual and infrared remote control and computer software to control and save your power and modeling power settings INTRODUCTION The PowerLights are a self contained light unit and power supply They have a professional plug in flashtube a 250 watt adjustable quartz modeling light and bare bulb capability
7. RC 2 can control up to nine 9 PowerLights with individual settings If several PowerLights are used with identical settings the same unit number can be assigned to them This will expand the total number of lights that can be controlled with the PLIRC 2 All panel button controls are available plus STANDBY All PowerLights must have PLDIR 2 infrared receivers and have their unique unit numbers assigned PowerLights may have identical unit number numbers if they are to be operated exactly the same under all studio arrangements Select a Unit Number on one of the top ten buttons then control the PowerLight with the lower buttons observing the PowerLight digital display for the changes The All button under Unit Number transmits the changes to all active PowerLights This enables the photographer to raise or lower flash or model levels on all the units without the laborious task of changing them all individually STANDBY lets the photographer put all the PowerLights into a standby state to stop public photographers from slaving the units at a wedding or some studio units can be put in standby when not required for a shot The infrared control can easily reach to units on 12 foot stands it has been tested to 100 feet indoors PLIBM 1 Studio System Controller software for IBM compatibles must be used with PL1250DR amp PL2500DR with PLDIR 2 receivers Along with infrared transmitter hardware and an IBM compatible computer using Wi
8. both vertically and horizontally The PowerLights are fitted with Photogenic s unique quick change system for holding accessories made by Photogenic Professional Before using your new PowerLight for the first time please read this manual carefully and acquaint yourself with the controls and features In this way you can quickly get the greatest benefit from your new unit and maintain an efficient and safe operation SAFETY PRECAUTIONS Despite the measures that have been taken to make electronic flash equipment safe it must be recognized that high voltages and high temperatures do exist within the power supply lighting unit Certain precautions must be observed in handling the unit Contact with internal high voltage may result in severe injury or death 1 Before installing or removing the flashtube and modeling lamp be sure this appliance is turned off cooled and unplugged from AC power source 2 Do not touch the glass tubes with bare hands as normal body oils will shorten the bulb s life Always use a clean cloth or wear gloves to protect your hand from glass breakage and heat 3 Do not defeat the purpose to the three wire line cord by disconnecting the ground Connect to properly functioning and grounded 3 pin receptacles only If you are using an extension cord be sure the cord has an equivalent or greater rating and has a ground 4 Do not insert a screwdriver or other metal objects into the flashtube socket area o
9. by itself without apparent reason Probable causes cao Tf Defective trigger cord or trigger cord incorrectly polarized Bright light falling on photoslave Poor connection in line cord Reverse connection on trigger cord connection at camera Some radio slaves will cause interference consult slave manufacturer Trigger cord will not flash unit but charge indicator shows that the system has charged Probable causes a b Defective trigger cord Defective flashtube Turn unit off Wait until cool then replace flashtube See SERVICE section of this manual Limited PowerLight Warranty Photogenic Professional Lighting warranties the standard line of new PowerLight products to be free from defects in material and workmanship of the PL2 series of PowerLights for a period of two years from date of purchase At our choice we will repair or replace any PL2 Solair or Voltage Smart series light that is deemed to be defective This warranty does not cover damages caused by shipping product abuse or use other than the intended photographic applications Any product modifications will render this warranty void Use of other manufacturer s accessories which restrict normal or intended operation especially venting airflow may cause damage and will void this warranty Flash tubes are warranted under the above conditions for one year from date of purchase Modeling lamps are covered for initial use failures only lotosemi
10. c Photogenic Professional Lighting 1268 Humbracht Circle Bartlett Illinois 60103 1631 www PhotogenicPro com Telephone 630 830 2500 Fax 630 830 2525 MANUAL PART NO 015756 00V3 05
11. d in making the observation The flash of the light should then appear as a circle the same size as the aperture If the circle is flattened on the sides or if no light appears through the lens the shutter is not synchronized If the shutter appears not to be synchronized a reputable camera repair shop should check the shutter contacts OPERATION PowerLight Model 1250 and 1250DR Flashing Rate The unit recharges quickly as indicated by the READY light on the control panel A quick series of flashes can be obtained within the limits of the recharge time Continuous rapid flashing however can overheat and damage the flashtube and internal parts The maximum recommended rate of flashing depends upon the power level being used and the amount of operation time Use the following chart to serve as a guide for the maximum rate to use in your situation Power Operating Sec Between Number of Level Time Flashes Flashes Full Continuous 15 Continuous 30 minutes 6 300 3 minutes 4 45 1 4 Continuous 6 Continuous 30 minutes 3 3 600 minutes 2 90 1 32 Continuous 1 5 Continuous Exposure Information The following charts give the BCPS output for various umbrellas and reflectors Coverage angle is given in degrees Umbrella 32 inch 45 inch 60 inch Coverage 120 degree 120 degree 120 degree Full Power 5500 5583 5583 Half 2750 2792 2792 Quarter 1375 1396 1396 Eighth 688 698 698 Sixteenth 344 349 349 Thirty Second 172 174
12. e rated duty cycle is exceeded A cooling off period of 10 to 45 minutes is required to reset the thermal fuse To replace a blown fuse power cord must be disconnected simply unscrew the fuse holder cap bottom of unit and replace the exposed fuse with a new fuse If fuses continue to blow contact your dealer or qualified service person See specification section for fuse replacements Power Switch The power switch controls the AC power to both the modeling and flash circuits You have the option to turn off the modeling circuit independently PowerLight Model PL1250 WARNING A A A A DONT OPERATE witwout GLASS LANP COVER 6 1 8 1 4 1 2 Ful pecans oi i Furt_ oj SET 0 ONOFF SLAVE I PowerLlizgh 2 41250 _ MADE IN U S A Flash Power All settings and controls of the PowerLight 1250 are extremely stable and repeatable due to the use of an internal microcomputer The 1250 and 1250DR are adjustable from 16watt seconds to 500 watt seconds je FLASH Ae 1732 1 16 1 8 1 4 1 2 FuLL MopEL v i vv v v To adjust the PowerLight 1250 to its lowest flash power setting 16 watt seconds slide the FLASH control knob all the way to the left To adjust the PowerLight 1250 to its greatest flash power setting 5
13. ected or switched off the flashtube will flash This removes most of the flash capacitor charge to prolong the life of the unit and is a much safer condition for storage transporting and replacement of flash tube or modeling lamp This is a feature over which the user has no control ADVANCED POWERLIGHT FEATURES Models PL1250DR and PL2500DR only Unit Number Assignment This feature allows the user to assign a UNIT NUMBER 1 to 9 to each DR type PowerLight in the studio The UNIT NUMBER is necessary when INFRARED remote control is used see accessories To assign a UNIT NUMBER Turn PowerLight AC power off With unit power off press and hold the 1 2 UP arrow button While holding the 1 2 UP arrow button turn the unit power on Digital display should be un where means some number to 9 Next release the 1 2 f stop UP arrow button Change the UNIT number using the 1 10 UP DOWN arrow buttons Close the assignment feature and save the UNIT number by pressing the 1 2 UP arrow button Advanced PL2 series Accessories PLDD 1 Digital display for Model 1250 only The PLDD 1 is a digital display to enhance the resolution and repeatability of the Model 1250 s Flash analog slide pot control It displays only Flash power over the full range of 16 to 500 watt seconds Resolution of the PLDD 1 is 0 1 f stop The PLDD 1 should be mounted to the umbrella bracket under the housing of the Model 1250 PowerLight on flexible rotating
14. ier at once Claim for damage should be made to the delivering carrier before destroying packing cartons To set up the unit first mount and secure it on a suitable stand The PowerLight stand adapter allows the unit to be mounted on a stand with a 3 8 to 5 8 post Be sure to use a stand that is stable and will not tip easily Unpacking and Setup continued The unit is shipped with the modeling lamp and flashtube not installed While installing the modeling lamp and flashtube with glove or clean cloth to protect the hand be sure they are properly inserted and tight to avoid arcing and failure of the socket contacts during operation Do not touch the glass tubes with bare hands as normal body oils will shorten the bulb s life Always use a clean cloth or wear gloves to protect your hand from glass breakage and heat The 7 1 2 inch reflector is attached by the quick change mechanism Three tabs on the unit grip the ring on the reflector Finger levers located on the top of the unit control two of these tabs To mount the reflector squeeze the finger levers towards each other and tilt the reflector past the stationary top tab then past the two tabs that are controlled with the levers Release the finger levers and make sure all three tabs are securing the reflector see illustration below All PowerLight accessory reflectors and soft boxes are designed for use with this quick change system or onto this 7 _ inch reflector
15. ilver satin flat panel inner umbrella with black blocking outer umbrella 45 Silver satin flat panel inner umbrella with black blocking outer umbrella 60 Silver satin flat panel inner umbrella with black blocking outer umbrella 12 x36 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 24 x 32 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 36 x 48 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 48 x 72 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 22 x22 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 36 x36 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket 48 Octagon 48 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket SERVICE The photographer should not attempt to make repairs Consult a dealer for an authorized Photogenic Professional Lighting service agent This will provide you safety insure proper operational functions and provide continuation of your warranty For replacing the flashtube or modeling lamp follow the directions and specifications given earlier in this manual in the setup section Before removing the old tubes or installing ne
16. le as well as the large assortment of PowerLight reflectors umbrellas softboxes snoots barndoors and cases See the listing later in this manual HHEH FLASH POWER LEVEL PLDD I PL1250DR and PL2500DR Accessories A Remote Digital display flash control a Remote Digital Display amp Infrared Receiver and a hand held Infrared Controller are available as well as the large assortment of PowerLight reflectors umbrellas soft boxes snoots barndoors and cases See the listing later in this manual UNIT NUMBER PLDIR I MADE IN U S A PLIRC I PowerLight Models 1250DR and 2500DR tm i Ll Poewernign 2500DR_ O NUSA fay aX f pes f _ S Flash Power Use the Adjust button to turn on the Flash ws red LED Adjust the PowerLight 1250DR or 2500DR Flash power setting using the 1 2 or 1 10 f stops UP DOWN arrow buttons Ready Light The PowerLight 2500DR is fully charged when the READY lamp is on Lowest power 32ws charge time is a maximum of 8 seconds and at full power charge 1000 ws time is a maximum of 3 seconds The unit may be flashed before fully charged The PowerLight 1250DR is fully charged when the READY lamp is on Lowest power 16ws charge time is a maximum of 5 seconds and at full power charge 500 ws time is a maximum of 1 5 seconds The unit may be flashed before fully charged Modeling Ligh
17. mount or on an extension cable for better viewing PLDRC 1 Remote digital display and flash adjustment for models 1250DR and 2500DR The PLDRC 1 is a digital display to enhance the visibility of and to change the Flash power setting It displays and controls only Flash power over the full range of watt seconds Resolution is 0 1 f stop using the 1 2 f stop and 0 1 f stop UP DOWN buttons The PLDRC 1 should be mounted to the umbrella bracket under the housing of the PowerLight on rotating mount or on an extension cable for better viewing and easier control accessibility PLDIR 2 Remote digital display and Infrared receiver for models 1250DR and 2500DR must be used with PLIRC 1 controller The PLDIR 2 is a digital display to enhance the visibility of and to receive infrared signals to control all functions of the 1250DR and 2500DR PowerLights It displays both Flash power and Modeling lamp power and unit number It has a green READY indicator and a Bl color indicator for Flash or Model Behind a small window is an infrared receiver Resolution is 0 1 f stop The PLDIR 2 should be mounted to the umbrella bracket under the housing of the PowerLight on rotating mount or on an extension cable for better viewing and infrared control Advanced PL2 series Accessories PLIRC 1 Infrared remote controller for models 1250DR and 2500DR must be used with PLDIR 1 receivers Similar to TV VCR DTV universal remote controllers the PLI
18. ndows 95 or 98 the software is used by the photographer to specify the PowerLight settings for up to nine units with independent settings and save a studio settings or as a pose file An unlimited number of pose files may be saved All PowerLights must have PLDIR 2 infrared receivers PLMAC 1 Studio System Controller software for MAC must be used with PL1250DR amp PL2500DR with PLDIR 2 receivers Along with infrared transmitter hardware and a MAC computer using Windows 95 or 98 the software is used by the photographer to specify the PowerLight settings for up to nine units with independent settings and save a studio settings as a pose file An unlimited number of pose files may be saved All PowerLights must have PLDIR 2 infrared receivers PLX 5 Five foot extension cable with adapter for PLDD 1 PLDRC 1 and PLDIR 2 displays PLX 10 Ten foot extension cable with adapter for PLDD 1 PLDRC 1 and PLDIR 2 displays PLX 15 Fifteen foot extension cable with adapter for PLDD 1 PLDRC 1 and PLDIR 2 displays POWERLIGHT QUICK CHANGE ACCESSORIES REFLECTORS PL7R PL14R PLI6R PLI6BD PLI6BDK PL20R PL20BD PL24R PL3R PL3RV PL5R PLSAK PL7MF PL7BDK PL7SNK PL7GK PLCW PLH 7 1 2 Standard high grain reflector 35 degree coverage 14 Parabolic for portraits feathering flood and fill lighting 60 degree coverage 16 Parabolic for portraits feathering flood and fill lighting 60 degree coverage
19. ons housing only eseseeeeeees 4 5 x 4 5 x 6 75 Flashtubes and Modeling Lamps Flas tubene Plug in style use only Photogenic s Standard C4 15 or C4 15C or C4 15F Modeling Lamp ccceeceeseeceeseeteeeeeteeees 250 Watt Quartz Halogen ESS 150 Watt Quartz Halogen ESP 100 Watt Quartz Halogen ESR USC snesen o ee i ATENTE 3AG type 15 Amp SLO BLO OPERATION PowerLight Model 2500DR Flashing Rate The unit recharges quickly as indicated by the READY light on the control panel A quick series of flashes can be obtained within the limits of the recharge time Continuous rapid flashing however can overheat and damage the flashtube and internal parts The maximum recommended rate of flashing depends on the power level being used and the amount of operation time Use the following chart to serve as a guide for the maximum rate to use in your situation Power Operating Sec Between Number of Level Time Flashes Flashes Full Continuous 15 Continuous 30 minutes 10 180 3 minutes 6 30 1 4 Continuous 6 Continuous 30 minutes 3 3 600 minutes 3 60 1 32 Continuous 3 Continuous Exposure Information The following charts give the BCPS output for various umbrellas and reflectors Coverage angle is given in degrees Umbrella 32 inch 45 inch 60 inch Coverage 120 degree 120 degree 120 degree Full Power 11000 11166 11166 Half 5500 5583 5583 Quarter 2750 2792 279
20. r vents Contact with high voltage may result 5 Do not operate this appliance with a frayed or damaged line cord When replacing or using the unit with an extension cable be sure the cable has an equivalent or greater rating and is a properly connected 3 wire grounded cable 6 Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 7 Do not operate the unit with a damaged or broken flashtube or modeling lamp Do not use flashtubes with broken cracked or missing glass envelopes To prevent damage always use Photogenic specified replacements for the flashtubes and modeling lamps 8 Perform no internal service work on this unit Refer all such service to a qualified service person or return to the factory This will provide you safety and continuation of your warranty 9 Do not operate when water is present and from extreme temperature shifts If the unit is stored in hot or below freezing temperatures allow at least one hour at room temperatures before using PREPARATION AND BASICS Unpacking and Setup Unpack all units carefully to remove all parts from the carton s Do not discard or destroy the packing material until the equipment has been inspected assembled and all parts accounted for After unpacking all parts should be examined for any damage which may have been caused by rough handling during shipment If any damage is detected contact the delivering carr
21. t The modeling light has three modes of operation 1 MANUAL press the ADJUST button to turn the MODEL yellow LED on adjusts the modeling lamp intensity using the 1 2 or 1 10 f stops UP DOWN arrow buttons Pressing the MANUAL button a second time will change the mode to flash adjustment and is indicated by the illuminated red LED 2 TRACK mode causes the modeling lamp intensity to track the FLASH setting The modeling lamp may be set to full intensity at any FLASH value by simply pressing the TRACK SET button a second time with the FLASH already set to desired watt seconds Setting is retained when user returns from another mode 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LED off or ON LED on All mode settings are retained even after the power has been turned off PowerLight Models 1250 1250DR and 2500DR Test Function The TEST button is pressed to fire the flashtube for test purposes Flash Indication The PowerLight indicates the flash has fired properly The flash indication feature will dim the modeling light to its lowest setting then intensify slowly to full brightness or to its original state This will occur after each flash even though the modeling light may be off This feature is turned ON LED on or OFF LED off with the FLASH INDICATION button Automatic Flash Dump This feature is set at OFF from the factory but can be turned on by the user See ad
22. type 15 Amp SLO BLO Packaging 6028 ra n i a Extruded Aluminum case Weight eeina E AAR ain 7 pounds Dimensions housing only eccseeeeeees 4 5 x 4 5 x 8 75 Flashtubes and Modeling Lamps Blashtube 3 2h ics inte nae ees Plug in style use only Photogenic s Standard C4 19 or C4 19C Modeling Lamp cececeseeeeseeeseeeeteeees 250 Watt Quartz Halogen ESS 150 Watt Quartz Halogen ESP 100 Watt Quartz Halogen ESR FUSE si epi Raa chan outs 3AG type 15 Amp SLO BLO ADVANCED POWERLIGHT FEATURES Models PL1250 PL1250DR and PL2500DR Automatic Dump Flash This feature will automatically flash the unit when the FLASH setting is lowered otherwise the internally stored power is discharged through a resistor before the unit is READY Flash Dump is faster This feature can be turned on or off by the user Turn FLASH DUMP on Turn PowerLight AC power off With unit power off press and hold the FULL ON OFF button While holding the FULL ON OFF button turn the unit power on and wait until the FULL ON OFF LED blinks Next release the FULL ON OFF button and the FULL ON OFF LED will go off Turn FLASH DUMP off Turn PowerLight AC power off With unit power off press and hold the MANUAL button While holding the MANUAL button turn the unit power on and wait until the MANUAL LED blinks Next release the MANUAL button and the MANUAL LED will go off Also each time the AC line power is disconn
23. vanced features section This feature will automatically flash the unit when the FLASH setting is lowered otherwise the internally stored power is discharged through a resistor before the unit is READY Flash Dump is faster The units recharge quickly and reducing your power setting slowly may result in additional flash discharges Synchronization and Triggering Triggering is accomplished by using a built in photoslave or a trigger cable from the power supply to the camera shutter contacts of X or zero delay Other units in the system are then triggered by photoslave operation It is best to connect the fill light directly to the camera since it will be positioned furthest back in the studio and will usually provide sufficient illumination to trigger the other units It is suggested that all walls and ceiling be painted either in white or light neutral colors for most reliable photoslave operation After the trigger cord is properly connected check the synchronization with the camera Adjust the lighting unit to same height as the camera lens and face the lights into the lens The lens aperture should be open to its fullest extent and set on X or zero delay Remove the camera back It is best to perform this test with the modeling lamps turned off While looking at the lens through the back of the camera operate the shutter A few sheets of white paper in front of the lens will cut down the brilliance of the flash and ai
24. w tubes always unplug your PowerLight and discharge the stored energy by pressing the test button Wait approximately two hours for the main capacitors to deplete any residual stored wattage Never place your fingers or any metal objects into the flash or modeling sockets Contact with high voltage may result General Trouble Shooting COMMON PROBLEMS AND CAUSES Unit does not charge Probable causes a b c Fuse blown Unplug and discharge the unit Replace fuse No line power to unit Check line cord and outlet Unit is on but will not charge Safety thermal detector activated by heavy use beyond specified Flashing Rates on page 9 Unit completely off but is connected to power and is turned on Safety thermal switch activated by internal discharge Decreasing flash power setting repeatedly with the down arrow key or placing the unit into STANDBY with the remote control repeatedly causes the flash power to discharge through an internal power resistor If the resistor over heats a thermal switch will open and cut off line power to the unit After a 3 minute cool off period the power will return This is a unit protecting feature and can be caused by user actions or circuit failure Modeling light does not turn on Probable causes a b Lamp turned off Press FULL ON OFF button until LED lights Lamp burned out Inspect and replace when cool See SERVICE section of this manual Light flashes