Philips F-2200 User's Manual

image

Contents

1. The flow straightener is made of 304 A 351 CF8 stainless steel TABLE 1 ALL DIMENSIONS SHOWN IN INCHES HOLES 1 0625 850 1 0625 8 10 62 1 0625 NOTE DIMENSION D INDICATES I D FOR SERRATIONS 0 0 f gre 7 DOOCOO OCOOOO OGOOGO DIMD DIMA OCOO0OO OOOOO OOQ a g DIM 8 N 0497 8 06 F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 22 0 125 7 GASKET THICKNESS NOMINAL SERRATIONS SHOWN LOCATED UNDER GASKET IF PROVIDED INCORPORATED ONICON F 2000 SERIES STEAM METER NOTE 1 300 ANSI FLANGE 600 ANSI FLANGE OPTNL ECCENTRIC REDUCER NOTE 2 FLOW STRAIGHTENER NOTE 3 x E E UPSTREAM oe E OBSTRUCTION i SEE TABLE 1 0 a E E 5 E 2 DIAMETERS DIMENSION B 5 DIAMETERS MINIMUM UPSTREAM PIPE RUN MINIMUM DOWNSTREAM PIPE RUN DIMENSION A REQUIRED DIMENSIONS FOR INSTALLATIONS WITH FLOW STRAIGHTENER DIMENSION A DIMENSION B UPSTREAM TOTAL UPSTREAM DISTANCE BETWEEN OBSTRUCTION PIPE RUN FLOW METER AND STRAIGHTENER SINGLE 90 12 DIA 10 DIA 12 DIA 10 DIA RDCR EXPNDR 12 DIA 10 DIA TWO 90 S SAME PLANE 17 DIA 15 DIA BALL GATE VALVE FULLY 17 DIA 15 DIA OPEN TWO 90 S OUT OF PLANE 22 DIA 20 DIA CONTROL VALVE 27 DIA 25 DIA 27 DIA 25 DIA NOTES 1 Consult ONICON for meter size and applicable meter pipe run for each application Install according to manufacturer s recommendations 2 Provide eccentric
2. INCORPORATED F 2200 Series Vortex Flow Meter Installation and Operation Guide 12 15 08 1500 North Belcher Road Clearwater FL 33765 Tel 727 447 6140 Fax 727 442 5699 www onicon com sales onicon com SAFETY INFORMATION This meter was calibrated at the factory before shipment To ensure correct use of the meter please read this manual thoroughly Regarding This Manual This manual should be passed on to the end user Before use read this manual thoroughly to comprehend its contents The contents of this manual may be changed without prior notice All rights reserved No part of this manual may be reproduced in any form without ONICON s written permission ONICON makes no warranty of any kind with regard to this material including but not limited to implied warranties of merchantability and suitability for a particular purpose All reasonable effort has been made to ensure the accuracy of the contents of this manual However if any errors are found please inform ONICON ONICON assumes no responsibilities for this product except as stated in the warranty If the customer or any third party is harmed by the use of this product ONICON assumes no responsibility for any such harm owing to any defects in the product which were not predictable or for any indirect damages Safety Precautions The following general safety precautions must be observed during all phases of installation operation
3. Incorrect angular position of the meter Refer to Section 3 1 1 for the allowable mounting positions e Insufficient upstream downstream pipe lengths Check that the upstream downstream pipe lengths are of the correct minimum length as given in Section 3 1 3 e Error in meter factor K Factor programming Contact ONICON for assistance e Check that the flow direction and the direction arrow on the meter body agree A non zero flow indi cated when no actual flow is in the pipe CHECK INST error is displayed when no flow is in the pipe Flow rate inidcated Is 0 0 even with flow in the pipe The flow indicated responds to changes in the flow but the indicated value does not correspond to the actual flow rate Also CHECK INST Error may appear intermit tently F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 21 SECTION 5 0 FLOW STRAIGHTENER FOR VORTEX FLOW METERS DESCRIPTION The optional flow straightener accessory for ONICON F 2000 Series Vortex Flow Meters is a water style flow conditioner that is designed to be installed between two recessed flanges provided by installer that are located a specified distance upstream of the flow meter Use of a flow straightener significantly reduces the upstream straight pipe length requirement for ONICON Vortex Flow Meters The size of the straightener should always match the meter size as opposed to the original pipe size
4. mode where self diagnostic checks are performed on the pre amplifier and sensor circuits Following this configuration data is loaded from the non volatile memory and the program advances to the measurement mode IMPORTANT NOTE The meter should be installed and powered for at least 15 minutes before media is allowed to flow through the meter CAUTION N Flow velocity through the meter should be increased gradually until full flow is achieved 4 2 MEASUREMENT MODE In the measurement mode the display indicates real time flow temperature and or pressure data in the appropriate units The top line of the display indicates the current measured value The second line of the display indicates the programmed units of measurement There are two options for displaying data in the measurement mode The display may be set to automatically scroll through each menu page or it may be set to manually step through the menu pages using the up arrow key to advance each page Displays operating in the cyclic mode will advance through each page every 6 seconds IMPORTANT NOTE When measuring steam flow condensate may form on the cool surfaces of the meter and piping system when the system is started up for the first time causing faulty measurement F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 18 4 3 OPERATING THE DISPLAY Please read the entire procedure before proceeding Wir
5. service and repair of this product Failure to comply with these precautions or with specific WARNINGS given elsewhere in this manual violates safety standards of design manufacture and intended use of the product ONICON Incorporated assumes no liability for the customer s failure to comply with these requirements If this product is used in a manner not specified in this manual the protection provided by this product may be impaired The following symbols are used in this manual WARNING Messages identified as WARNING contain information regarding the personal safety of individuals involved in the istallation operation or service of theis product CAUTION Messages identified as CAUTION contain information regarding the potential damage to the product or other ancillary products IMPORTANT NOTICE Messages identified as IMPORTANT NOTICE contain information critical to the proper operation of the product F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 3 F 2200 Series Vortex Flow Meter Installation and Operation Guide Addendum December 12 2008 The drawing below illustrates the proper method for insulating the flow meter CAUTION Insulating the entire neck of the flow meter will increase heat transfer to the electronics enclosure and may in some Cases cause premature failure of the electronics F 2000 SERIES STEAM FLOW METER WITH INSULATION DETAIL INSULATION NECK PIP
6. 1 3 2 1 2 Steam or compressed gas 822110810 5 3 2 2 Flanged type connections to ANSI B16 5 Schedule 40 eee 32 3 lemperat re 0 AE RaT RO Wino TOn O ena aa 40 STARPFUP henin rani EEEa 4 ENAT EEEE SDA 42 Measurement Mod orson rinore erenn E E EE EENE EEEIEE oA NEETA ETN do Opara mne e D pia E A EAO AEE e E E EE A E E E A 4 5 Troubleshooting Hints esssssssesssssereesssssereeessserrresssscretesssseeeessseereesssseerressssereeess 50 FLOW darani ainnir ie r anieri F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 5 F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 6 SECTION 1 0 INTRODUCTION We at ONICON INCORPORATED would like to thank you for purchasing our F 2200 Series Vortex Flow Meter As our valued customer our commitment to you is to provide fast reliable service and assistance while continuing to offer you new products to meet your growing flow measurement needs 1 1 PURPOSE OF THIS GUIDE The purpose of this guide is to provide installation and commissioning procedures and basic operating and servicing instructions for ONICON F 2200 Series Vortex Flow Meters WARNING Only qualified service personnel should attempt to install or service this equipment Serious injury may result from the improper installation or use of this equipment 1 2 PRINCIPAL OF OPERATION ONICON F 2
7. 90 BENDS IN PLANE 90 BEND OR T PIECE With a flow straightener the inlet pipe length may be reduced by 50 For example with a control valve upstream the inlet length is 25D instead of 50D The minimum inlet pipe length including the flow straightener must always be at least 12D 3 1 4 Minimizing Pipe Vibration Pipe vibration caused for example by the action of pumps valves etc will distort flow measurements particularly at low flow velocities To minimize the effects of vibration support the pipeline on both sides of the meter in a direction perpendicular to both the pipeline and the shedder bar axis F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 13 Locating The Meter In A Pipline That Runs Parallel To A Wall Wherever possible the distance between the pipe centerline and the wall should be greater than 20 This will allow for access to the electronics enclosure compartment where wire terminations are made If adequate space is not available first connect all the cables to the terminals in the connection compartment power supply and outputs and then run the wires to an intermediate junction box also see Section 3 2 before installing the meter State Of Medium In all cases the meter requires a single phase flow for proper operation Liquid droplets in the gas or vapor solid particles in the gas or liquid and gas bubbles in the liquid are not permitted 3 1 6 1 Liquid App
8. below are minimum requirements for the proper operation of this flow meter 3 1 1 Flow Direction And Meter Position The flow must always be in the direction of the arrow located on the meter body This will orient the bluff side of the vortex shedder bar so that it faces the incoming flow i e the upstream side For vertical pipe runs flow must always be in the upward direction Consult the factory in the event that a downward flowing pipe is the only available location F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 11 The diagrams shown below illustrate the correct meter orientation for vertical and horizontal pipe 3 1 2 Maximum Allowable Difference Between Inside Diameter Of Meter Body And The Connecting Pipe The table below provides the maximum allowable difference between the diameter of the flow meter body and the connecting pipe Meter Body Maximum Pipe ID Diameter in Difference in 0 016 0 016 Ensure that the bore of the locating pipes are smooth and without deposits scaling or welding beads F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 12 3 1 3 Straight Unimpeded Inlet And Outlet Runs D Meter Size Nominal diameter in inches INLET OUTLET CONTROL VALVE OR PRESSURE REDUCING VALVE PRV BALL GATE VALVE FULLY OPEN 2 90 BENDS OUT OF PLANE z 9 SAME FOR 3 X 90 BENDS 40D _5D 2
9. rate will go up by the factor which is approximately equal to the square root of the gains odd gains new gain If the minimum flow with reduced gain is above the minimum flow which is required to be measured then reducing the gain is not the permanent solution Then the installaion should be corrected and also the vibrations should be eliminated The display should normally indicate 0 0 flow rate LOW FLOW or LOW SIGNAL when there is no flow in the pipe The additional CHECK INSTALL error flow rate 0 0 or some steady or fluctuating value is an indication of e Improper inadequate earthing e Excessive pipe vibration e The vortex sensor cable is disconnected or is not properly connected e Flow sensor is faulty Contact ONICON for assistance e The meter is not properly centered on the pipeline The axis of the meter bore should be aligned with that of the pipe e Gaskets at the meter are protruding into the pipe bore The gaskets must not project into the effective cross section of the pipe e Irregularities on the surface of the pipe bore The pipe bore should be free from irregularities at the welded joints dirt deposits and excessive surface rough ness e The Vortex signal is distorted due to a bi phase medium Bi phase media are not permitted Use a moisture separator for wet steam applications to remove the moisture droplets from the steam Use suitable filters in gas applications to remove solid particles from the flowing gas
10. 000 series vortex flow meters utilize Karman s vortex street principal to detect changes in velocity in the medium flowing around the titanium shedder bar and through the meter body A volumetric flow rate is then derived by utilizing the known cross sectional area of the meter body and the average velocity of the medium When provided with optional temperature and or pressure compensation the F 2000 series flow meters are capable of calculating the required density corrections necessary to provide direct mass flow measurement of liquids steam or gases 1 3 FEATURES AND SPECIFICATIONS CONSTRUCTION Meter body Casting 316 stainless steel for diameters up to 4 304 stainless steel for 6 and 8 diameters Shedder bar Unalloyed titanium ponte ee g Shedder bar seal Ni plated Inconnel D morina amper pin o ring 0 A Viton for non steam 4 to 356 F Body Kalrez 4079 for non steam 4 to 428 F Parofluor for steam 4 to 464 F Electronics enclosure Hane Enclosure material Die cast aluminum fee Enclosure viewing window Tempered glass a P A UV blocking mM my a i CALIBRATION aN by j Each meter undergoes a 5 point velocity calibration Ta 2 from 0 250 ft sec Flow Direction Arrow PROGRAMMING Each meter is programmed at the factory based on application specific data provided by the customer Field re programmable via keypad with coded access for security F 2200 Series V
11. 1 Flow rate if OK 2 Check for excessive pipe vibration and upstream flow disturbances 3 Contact ONICON LOW SIGNAL Vortex signal amplitude too Check 1 Flow rate if OK 2 Contact ONI low CON HIGH SIGNAL Vortex sensor signal This occurs in cases of high density medium amplitude too high Check 1 Flow rate if OK 2 Contact ONI CON LOW TEMP PHY Operating temperature is Take corrective action depending on the pro lower than the physical limit cess Operating temperature is Take corrective action immediately This will HIGH TEMP PHY higher than the physical limit cause damage to the shedder bar as well as to the electronics Temperature sensor wires Indicates a fault in the temperature sensor short circuit Contact ONICON Temperature sensor open circuit T SENS SHORT T SENS OPEN F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 20 4 5 TROUBLESHOOTING HINTS REPORTED POSSIBLE PROBLEM SOLUTIONS e Mains interference due to improper Earth ground connection The protective Earth PE terminal should be properly grounded see page 17 e Excessive mechanical vibration in the pipe If so support the pipeline near the meter perpendicular to both the axis of the pipe and the axis of the shedder bar e This problem may also be solved by reducing the factory set gain Contact ONICON for assistance NOTE By reducing the gain the minimum measurable flow
12. E F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 4 TABLE OF CONTENTS TO INTRODUCTION piene ten sencraas ance EE AE EE E NEEE EE E ol TUS 4 2 mee Operai esiin onn Ee e rrr eer ee cere tr eet er eer 1 3 Features and Specifications esssessessssserreesssseerressssrreesssereeesssserrresssseereessserressssees 1 4 Additional Required Materials vaccrecaatoutentecutescaneetecuaracnideaseiestcresosesusutesereeeanecaceases 15 Working Env ionmieii serais a ee E E ETE Da 100 Serna NEDO soais S E E E E A EAE EEE EE E E E A E 20 UNEA CGE ING E E E E E E E E er E 2 1 Checking That You Have Received Everything essssessssssssessssserrresssserrsesssrrressssees 3 0 INSTALLATION E E E A EEEE T 3 1 1 Flow direction and meter position sssssessssssreeesssssrreessssrrressssereressserreress 3 1 2 Maximum allowable difference between inside of meter body and the connecting ell oon atte Terre tent rere tect eer rere ne 3 1 3 Straight unimpeded inlet and outlet PUNS ee eeeeecccceeeeeeeeeeeenaeneees 3 1 4 Minimizing pipe 3 1 5 Locating the meter in a pipeline that runs parallel to a 11 SLO TO a EEEE E E E E EE NS oe ir ct CIUC 3 1 6 2 Steam or compressed gas applications ceeeeecceeetseeeeeeeeeees ante ee erent en ener rte ert eee er ae eee 3 2 1 Orient the display for convenient VIEWING 32 1
13. appear in the top left corner of the display indicating an error has been detected If the error reporting function is enabled error messages will be displayed as separate menu pages The first line of the error menu page indicates the total number of errors and the second line displays the error message Measurement mode error messages are listed below Error Message Type Description Corrective Action display second line Required NO SIGNAL No signal from the vortex No flow Also check for any other errors dur sensor ing power on diagnostics If there is a sensor problem contact ONICON LOW FREQ Vortex frequency is too low Check for flow rate lower than specified mini mum Contact ONICON HIGH FREQ Vortex frequency is too high Check for flow rate higher than specified maxi mum Contact ONICON LOW FLOW Flow rate lower than speci Converter will continue to display actual flow fied range rate However accuracy of measurement may suffer HIGH FLOW Actual flow rate higher than Corrective action depends on application pro specified range cess If the flow rate exceeds the maximum value it may damage the sensor physically INV CONFIG Configuration data in non Contact ONICON volatile memory is not valid ISO FAIL Checked Sensor isolation has failed Contact ONICON AMP FAIL during Pre amplifier section has Contact ONICON power failed PIEZO FAIL nony Contact ONICON CHECK INST Flow signal quality is bad Check
14. ing diagrams are located in the Appendix A worksheet for checking off the following steps and recording measured values is located on the next page on key Hall Effect Switch f J M Series ONICON Incorporated key Hall Effect Switch key Hall Effect Switch Display page scroll measurement mode IMPORTANT NOTE Do not attempt to enter the program mode without first contacting ONICON service There are 3 user interface switches located immediately below the display Each switch performs a separate function The table below describes the function of each switch There are also 3 corresponding Hall Effect switches that perform the same functions The Hall Effect switches may be activated without removing the display cover using the magnet provided with the meter Place the magnet against the cover in proximity to the Hall Effect switch to activate ie Scrl though maa maces Sordin rement MHN paH PROGHA M 5 CAUTION e Do not remove enclosure covers in any wet environment e Keep dirt and debris out of electronics enclosure e Keep threads lubricated silicone based lubricant e Do not over tighten covers Use special tool for removal only F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 19 4 4 ERROR HANDLING The meter can detect errors in either the test or the measurement modes When in the measurement mode a blinking vertical bar will
15. l flow rectifier may be required in cases where the available space is not sufficient to allow for proper upstream straight pipe run 1 5 WORKING ENVIRONMENT ONICON F 2000 series vortex flow meters are designed for use in industrial environments that are free of corrosive liquids fumes and excessive vibration Do not expose the flow meter electronics enclosure to direct sunlight Install a sunshade if necessary Do not expose the flow meter to intense vibration If necessary provide additional support to the pipeline at the meter location to minimize vibration The rotating design of the electronics enclosure makes it easier to connect the power and signal cables to the terminals in the rear of the enclosure Rotate the enclosures as necessary before installing the meter The ambient operating temperature range is 0 to 132 F 1 6 SERIAL NUMBER The serial number for your F 2000 series vortex flow meter is located on the metal identification plate mounted on the side of the electronics enclosure Please have this number available whenever you contact ONICON for assistance F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 9 SECTION 2 0 UNPACKING F 2000 series vortex flow meters are shipped in one package Additional items if ordered will be shipped in separate packaging All shipments are insured for damage in transit Carefully inspect each package and notify the freight carrier and ONICON immediatel
16. lications When operating with liquids the meter requires a minimum downstream pressure to prevent cavitation The formula used to determine the minimum downstream pressure is as follows Pds bar_g gt 2 9 DP 1 3 Ps 1 013 Where DP pressure drop of the meter in Bar as determined by the ONICON sizing program and Ps saturation pressure in Bar at the operating temperature For any fluid a filter or strainer may be used to remove the solid particles This is especially important for meter sizes below 1 where a filter or a strainer is required 3 1 6 2 Steam Or Compressed Gas Applications In case of steam or compressed gas a moisture separator should be used 50D upstream of the meter if the dryness fraction is less than 95 IMPORTANT NOTE Steam quality will affect the accuracy of the measurement It is strongly recommended that a moisture separator be installed upstream of the inlet straight pipe run for anything less than 95 dry steam 3 1 5 3 1 6 F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 14 3 2 MECHANICAL INSTALLATION 3 2 1 Orient The Display For Convenient Viewing Both the electronics enclosure and the display itself can be rotated to four different orientations to change the viewing angle for the display If necessary this should be done before the meter is installed 3 2 1 1 Rotating the electronics enclosure The electronics enclosure is attached to the meter b
17. ody with 4 5mm Allen head screws To rotate the enclosure you must first remove the screws and then carefully rotate the enclosure as needed The interconnecting stem assembly is a conduit for wires that connect the sensors to the circuitry contained in the enclosure Care must be taken to prevent these wires from being damaged when rotating the enclosure Sensor Wires CAUTION Make certain the sensor wires are not damaged when re attaching the enclosure F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 15 3 2 1 2 Rotating the display To rotate the display first unscrew the cover using the special tool provided for this purpose Once the cover is removed the 4 Philips head screws that secure the display are exposed To rotate the display remove these screws and carefully move it to the desired position making certain that the interconnecting cable is not damaged in the process CAUTION Do not remove enclosure covers in any wet environment Keep dirt and debris out of electronics enclosure Keep threads lubricated silicone based lubricant Do not over tighten covers Use special tool for removal only Philips screws Interconnecting cable 3 2 2 Flanged Type Connection To Ansi B16 5 Schedule 40 Meter sizes Ba 1 2 oa 1 1 1 2 a 3 4 6 g Pipe flanges To ANSI 300 standard 600 optional Gaskets are supplied with flanged units Center the flow me
18. ortex Flow Meter Installation and Operation Guide Revised 12 08 7 ACCURACY Volumetric flow 1 of reading accuracy 2 for 34 8 smaller sizes Mass flow 1 5 of reading accuracy 2 5 for 34 amp smaller sizes OPERATING TEMPERATURE RANGE Media temperature 25 to 464 F Ambient temperature 0 to 132 F DISPLAY USER INTERFACE 16x64 dot matrix LCD with 3 button keypad and magnetic pin programming OUTPUT SIGNALS Rate 4 20mA loop powered Supply voltage range 14 36 VDC Minimum load resistance 100 ohms Maximum load resistance is calculated as follows Max load Vs 12V Where Vs supply voltage 0 020A Total Scaled output pulse programmable Optically isolated open collector 0 5 hz maximum Rating 5 36 VDC 100mA maximum SUPPLY VOLTAGE 14 36 VDC PROCESS CONNECTIONS Standard ANSI 300 flanges Optional ANSI 600 flanges APPROVALS Safety Conforms to CE mark as per LVD PED and EMC Directive Enclosure Conforms to IP 65 and IP 67 F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 8 1 4 ADDITIONAL REQUIRED MATERIALS Installer is responsible for providing suitable flanges and fasteners to connect the meter to the process piping In addition most installations will also require one reducer one expander pipe supports and a sufficient length of straight pipe pipe diameter meter size to meet the installation requirements outlined in this manual Use of an optiona
19. reducer and expander when required 3 Provide flow straightener when required to meet recommended minimum upstream pipe run requirements 4 Flanges provided by contractor Recessed flanges are required for wafer flow straightener installation F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 23
20. ter by sight Check the flange connections for leak tightness after the flow meter installation F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 16 3 3 2 Temperature Measurements ONICON F 2000 series vortex meters are supplied with an internal PT 1000 type RTD temperature sensor located within the shedder bar This sensor provides an accurate temperature measurement at the point where the flow rate is being measured Flow meters supplied with this option will display the medium temperature and deliver an output signal that is temperature compensated for mass and or normalized flow 3 3 WIRING TERMINATIONS The standard F 2000 series vortex meter is a 2 wire loop powered device Wiring connections are shown below CAUTION Do not remove enclosure covers in any wet environment Keep dirt and debris out of electronics enclosure Keep threads lubricated silicone based lubricant Do not over tighten covers Use special tool for removal only Connection Diagram 100 ohms minimum a pou 5 TO 36 VDC 14 TO 36 VDC 5 TO 30 VDC EEx 14 TO 30 VDC EEx 100 mA MAX Earth Connection F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 17 SECTION 4 0 START UP AND TROUBLESHOOTING 4 1 START UP When the power is applied to the F 2000 series vortex meter alphanumeric characters will appear on the display Initially the meter will operate in a TEST
21. y if any items arrive damaged 2 1 ENSURING THAT YOU HAVE RECEIVED EVERYTHING Standard Documentation Each ONICON flow meter is serialized and supplied with a comprehensive documentation package specifically prepared for this meter It includes the following items Please notify ONICON immediately if any discrepancies are found Flow Meter The F 2000 Vortex Flow Meter Installation and Operation Guide The Flow Meter Calibration Data Sheet Magnetic programming pin Calibration Data Sheet Magnetic programming pin r e 0 1 j Flow Meter Product Brochure F 2200 Series Vortex Flow Meter Installation and Operation Guide Revised 12 08 10 SECTION 3 0 INSTALLATION INFORMATION The F 2000 series vortex flow meter must be installed by a technician qualified to work with pressurized liquid steam and or gas flow and must conform to all federal state and local building codes ONICON will be happy to assist with technical recommendations and to provide guidance via telephone or mail On site engineering installation and service are also available at additional cost 3 1 SITE SELECTION Careful attention in locating the point in the piping system where the flow meter will be installed will ensure accurate and reliable operation When selecting an installation site consider the criteria contained in Section 1 5 WORKING ENVIRONMENT as well as the following CAUTION The installation guidelines presented

Download Pdf Manuals

image

Related Search

Related Contents

Samsung GT-E1080 Priručnik za korisnike  Instruction and Service Manual  Minka Lavery 2255-613 Instructions / Assembly  DGR n. X/1105 del 20/12/2013 - Azienda Sanitaria Locale di Bergamo  Intel TE430VX User's Manual  Cal Flame Fireplaces & Firepits 2006 User's Manual  Manual Servico Aspirador AIRMAX-R00a.p65  New Title  GEAppliances.com    