Home
Perlick Back Bar Cabinet BSDZ User's Manual
Contents
1. INTERIOR Walls Stainless steel Includes pilasters 2 vinyl coated shelves and floor rack per door and interior lights Front back top and sides stainless steel Bottom galvanized steel See optional accessories for door amp EXTERIOR Foon an grille finishes DOOR HINGING Stainless steel hinges with standard location as illustrated For special hinging hinge locations starting left to right Field reversible DOOR HARDWARE Door handles Choice of full length stainless steel classic 6 black vinyl wrapped pull or top mounted stainless steel pull tab Lock finish chrome R 134a capillary tube type Aluminum fin and copper tube evaporator epoxy coated coil Adjustable REFRIGERATION temperature control for each temperature zone Self defrosting Pull out condensing unit for service and cleaning Condensing unit and evaporator left side only 115V 60Hz 1 phase AC Furnished with 3 prong 6 foot NEMA5 15 PC cord Contact Perlick for other ELECTRICAL voltage frequency requirements Evaporator condensate is removed automatically Optional floor drain with 3 4 NPT at right end or 1 NPS PLUMBING out bottom come plugged from factory INSULATION Foamed in place polyurethane 2 walls 11 2 top OPTIONAL Leg set Door finishes Glass door with stainless ACCESSORIES amp e Laminated top Black vinyl coated steel frame MODIFICATIONS Laminated ends Stainless steel Glass door with laminated frame Grille finishes Blac
2. What was the door top is now the door bottom Carefully lift the door onto the hinge brackets of the cabinet The two hinge bushings should meet Reinsert the bottom hinge pin to complete the door switching operation Wiring Diagram BSDZ60 2 Door Dual Zone Back Bar Cabinet 2 DOOR MULLION HEATER RED LIGHT BLACK SWITCH WHTE b WHITE WHITE BLACK q 1e SOLENOID Partition Wall EVAPORATOR FAN pn oc TIENDEN ar tion Wa NS BLACK rom T c WHITE Iw BLACK WHITE WHITE FAN MOTOR Partition Wall MAN BLACK THERMOSTAT Compartment 1 EET g d amp POWER CONNECTION CONDENSING UNIT BLACK ly JUNCTION BOX Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice oot Form No 22304 7 Rev 05 22 10 8300 West Good Hope Road Milwaukee WI 53223 e Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 e E Mail Perlick Perlick com www Perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2304 8 Rev 05 22 10
3. INSTALLATION AND OPERATION INSTRUCTIONS DUAL ZONE BACK BAR CABINET SELF CONTAINED MODEL NOS BSDZ Series Ut Compressor Warrant LLL LLL LLL LL 20009999 DA BSDZ60 IMPORTANT INFORMATION Table of Contents To register your product visit our web site at www perlick com Click on Commercial then PREPARING THE CABINET Service You will see the link to Warranty Specifications a aA aa a aa aaa a 2 Registration Form You must complete and submit Ricco 3 this form or the installation date will revert back to ilVigolo lgio eret m 3 the ship Date zen E E A A ARE a 3 Uncrating and Inspection 3 This manual has been prepared to assist you in the installation of your Cabinet and to acquaint you Installing Casters Or Legs ainean ote eo aiiai 3 with its operation and maintenance Placing the Cabinet seite edat 3 Leveling the Cabinet ssssssusse 3 We dedicate considerable time to ensure that our nstalling the Base Plate 3 products provide the highest level of customer Refrigeration and Temperature Control 4 satisfaction If service is required your dealer can Cleaning the Cabinet eseessss 4 provide you with a list of qualified service agents Cleaning the Condenser 4 For your own protection never return merchand
4. and cleaned if necessary Use a long handled stiff brush to clean the dirt from the front surface of the condenser Keeping the condenser free from dust and dirt will ensure efficient operation Failure to keep the condenser clean will cause a loss in condensing unit efficiency and may damage the compressor CAUTION Do not bend the fins while brushing the front of the condenser JOB CLEANING AGENT COMMENTS Routine Cleaning Soap ammonia detergent Apply with sponge or cloth Can be used on all finishes Fingerprints and smears Areal 20 Lac O Nu Lumin Wash O Cedar Cream Polish Provides barrier film to minimize fingerprints Can be used on all finishes Stubborn stains and Discolorations Allchem Concentrated Cleaner Samae Twinkle Zud Restoro Grade F or FFF Italian Pumice Whiting or Talc Liquid Nu Steel Copper s or Revere Stainless Steel Cleaner Lumin Cleaner Sta Clean Cameo Copper Cleaner Allen Polish Highlite Penny Brite Copper Brite Rub lightly using dry or damp cloth in the direction of polish lines on the stainless steel Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement Omission of any proprietary cleaner does not imply its inadequacy All products should be used in strict accordance with instructions on the package Reick Form No Z2304 Rev 05 22 10 NOTE Do Not Use Steel Wool o
5. densate from the cooling coil is automatically evaporated through a condensate pan located in the side condensing unit compartment For your convenience a factory installed floor drain is located in the back right corner of the cabinet This can be plumbed to an external floor drain The floor drain can be plumbed from the cabinet right side using a 34 NPT connection or out the bottom using a 1 NPS connection Both ports of the drain come capped from the factory Electrical The cabinet must be connected to a separately fused power source see electrical specification plate and grounded in accordance with National and Local Electrical Codes Caution Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate Uncrating and Inspection Remove all crating material before operating Carefully inspect cabinet for hidden damage If damage is discovered file your claim immediately with the transportation company Perlick is not responsible for damage in transit Installing Casters or Legs Optional Attach four casters or legs to the cabinet bottom mount rigid casters at the rear and swivel casters on the front Use the supplied 1 4 20 x 3 4 hex head self tapping machine screws Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Installing Base Plate Optional Attach brac
6. ise GleahininStalnless Steelos ie ce e ee mr A for credit without our approval g Stainless Steel Replacement Parts eeeeeeusessss 5 We thank you for selecting a Perlick product and Reversing Door Hinge vcre nite etna c nan 6 assure you of our continuing interest in your Wiring Diagram ccccccccssscsescscsetscsesetetsescseseenees 7 satisfaction WARNING When lifting the full weight of the cabinet must be supported Lift from the cabinet base and not from the top Improper lifting can result in severe damage to the cabinet 8300 West Good Hope Road Milwaukee WI 53223 e Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 e E Mail Perlick Perlick com www Perlick com Form No Z2304 Rev 05 22 10 Installation and Operating Instructions Sizes and Specifications Dual Zone Back Bar Cabinets Self Contained Wear Ms amp BSDZ60 MODEL NOS NUMBER OF DOORS 2 Length Inches mm 60 1524 CABINET DIMENSIONS Depth Inches mm 243 4 629 Height Inches mm 341 2 876 CASE CAPACITY based on 12 oz Long Neck bottle 15 shelves CASE CAPACITY based on use of full extension wine 48 bottles per door CONDENSING UNIT H P 1 4 RUNNING LOAD AMPS 5 5 SHIP WT Lbs kg 390 177 Door sill High strength polyethylene Door pan and ceiling High strength polystyrene Floor pan and
7. k vinyl coated Stainless steel Customer choice of laminate Painted in color of choice Customer choice of laminate Painted in color of choice Prepared for field lamination Glass door with black vinyl coated frame Full extension wine shelves Brass hardware classic amp full length only Caster sets Base plates NOTE C CONDENSING UNIT NOTE This equipment is intend 60 1524 2 DOOR oat s 4 ed for the storage and display 31 1 4 629 of non potentially hazardous 794 4 1 4 bottled or canned products only Bos 44 1118 2 DOOR DOOR 108 73 6 NOTEB HEIGHT 182 6 5 16 4 1 4 E T 161 m 107 AR Tol oes T UTD ERSII hold 27 7 16 697 16 3 8 BACK LINER doc i 376 TO INSIDE OF OPENING t DOOR SILL 1 1 8 E ES de 19 7 8 X GERM au NOTE C mum 05 zi 43 16 F 106 F j DOOR yj B GUENING yere NOTE A N R23 1 2 NOTE A 3 4 NPT DRAIN EXIT 578 ES d NOTE B 1 NPS DRAIN EXIT FRdick Form No Z2304 Rev 05 22 10 AVAILABLE LEFT ONLY Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Preparing the Cabinet for Use Suggested Tools 2 Phillips Screwdriver 10 Crescent Wrench 9746 Allen Wrench 5 16 and 3 8 Hex Socket Power Drill or Driver Plumbing No plumbing required Con
8. kets to cabinet bottom in holes pro vided Attach base plate to brackets See separate instructions provided with kit When returning cabinet to upright position be careful not to bend brackets WARNING To avoid compressor damage after returning cabinet to an upright position let unit stand for 24 hours before plugging it in Placing the Cabinet Push the cabinet into place using rollers when necessary Important Proper air flow around the condensing unit is necessary for efficient operation Never obstruct the air flow in and out of the condensing unit For sanitation purposes it may be necessary to seal the base of the cabinet to the floor This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor as shown by the figure at below CABINET BEAD SILICON SEALER RTV FLOOR Leveling the Cabinet When the cabinet is in place check installation with carpenter s level When level front to back and left to right accumulated water will drain out of cabinet evaporator drain Form No Z2304 Rev 05 22 10 General Information Refrigeration and Temperature Control Each zone has been factory set to maintain the desired temperature specified when ordered The factory set storage temperatures are as follows Refrigerator 34 to 38 F White wine 50 to 55 F Red wine 60 to 65 F Adjusting the Temperature The te
9. mperature control in the left compartment is located on the left side of the evaporator fan panel The temperature control in the right compartment is located on the top rear partition wall You will need a flat head screwdriver to turn the adjusting screw on the control Make small adjustments until the desired temperature is achieved B Colder Temperatures Turn the adjusting screw clockwise to the right Warmer Temperatures Turn the adjusting screw counterclockwise to the left B Temperature Control OFF Turn the adjusting screw completely counter clockwise to the O position until a click is noted The condenser fan motor turns off and on with the compressor The evaporator fan motor runs continuously The partition wall fan cycles with the damper assembly Recommended Cleaning Agents NOTE Cabinet Temperatures lower than 34 will not allow for proper defrosting of the evaporator coil If defrosting is necessary remove product from the cabinet and turn the control adjusting screw to the OFF position until coil is defrosted Cleaning the Cabinet Use a mild detergent and water to clean the inside and outside of the cabinet Dry thoroughly Never use a scouring pad or abrasive cleanser NOTE An industrial strength commercial cleaner can be used to clean the outside of painted cabinets Cleaning the Condenser The condenser located behind the front grille cover should be inspected every 30 days
10. o vacant right hinge holes Form No Z2304 Rev 05 22 10 Top Hinge Bracket Bottom Hinge Bracket Hinge Bushing Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice STEP 8 Re assemble hinge brackets to unit Bottom right brack et is assembled as the top left bracket Top right bracket is assembled as the bottom left bracket STEP 9 Re insert top hinge pin STEP 10 Re assemble lock rail from STEP 3 Bottom Hinge Bracket Top Hinge Bracket Operations to Perform on Door Step 14 STEP 11 Remove bottom door hinge bracket from door assem bly and remove door hinge bushing from bracket Re assemble door hinge bracket to previous position without bushing STEP 12 Remove top door hinge bracket from door assembly and assemble door hinge bushing from STEP 11 to bracket Re assemble door hinge bracket to previous position with bushing attached STEP 13 Door with full length SS handle There is no need to remove door handle It will be positioned correctly when door is reversed Step 12 Step 11 Step 13 Door with SS pull tab or handle with wrap around bracket Remove the two screws mounting the handle and reposition to appropriate location on the opposite side of the door STEP 14 Remove lock retainer and install on opposite end of door STEP 15
11. r Scouring Pads to clean stainless steel Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Replacement Parts Dual Zone Back Bar Cabinets MODEL NOS Complete condensing unit Gasket door Hinge group right Hinge group left Hinge pin Shelf wire Shelf wine rack Clip shel Replacement top Replacement door Contact Perlick Milwaukee for complete door and top replacement Cabinet serial no required Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2304 5 Rev 05 22 10 Reversing Door Hinge Tools Required m 3 Phillips Screwdriver m 1 16 Allen Wrench m Flathead Screwdriver Right Hinged Door as shipped from factory Handle Styles C31409 1 6930551 Not Reversible 65189 Operations to Perform on Cabinet STEP 1 Remove bottom hinge pin from assembly STEP 2 Carefully lift and tilt out door assembly from the unit and set aside STEP 3 Remove lock rail from cabinet requires removal of four screws STEP 4 Remove top hinge pin Remove top and bottom hinge brackets from the unit STEP 5 Remove hinge bushing from bottom hinge bracket and assemble to top hinge bracket STEP 6 Taking care not to scratch the surface remove hole plugs from the left hinge holes STEP 7 Insert hole plugs int
Download Pdf Manuals
Related Search
Related Contents
2 - 取扱説明書ダウンロード Philips Sports armband SJM3200 STIHL HSA 65 gestão de ativos de rede com auxilio de um sistema cmdb SOLICITUD USER MANUAL LL FLOOD WASH Contador Baxi EcoBlue Advance Heat Quick Start Manual Solving the Mystery of the HP LaserJet 2400 and Copyright © All rights reserved.
Failed to retrieve file