Home

Perle Systems S-10G-XTSH User's Manual

image

Contents

1. Illustration of the FFA feature Media Conv SEE Converter End gt End Device gt a EE Device Fiber Port 1 Fiber Port 2 i Port 2 as Port 1 Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX 2 Media Converter A notifies the remote Media Converter that there is a fault on the Link 3 Media Converter B detects loss of fiber link on receiver RX 4 Media Converter B turns off transmitter TX EDC AutoDetect Mode Switch 4 and Switch 5 SFP Models Only Switch Position Mode Up default On Down Off On When AutoDetect Mode is turned On the S 10G media converter will establish the linear or limiting settings based on the contents of the EPROM on the module and the module type Off When AutoDetect Mode is turned OFF the S 10G media converter will select the alternative mode that was established by the determination above Perle S 10G Media Converter Installation Guide Operation Powering up the Perle Media Converter 1 Connectthe Perle supplied power adapter to the media converter 2 Turn on the power at the source 3 Check that the PWR LED light is lit Status LED The Perle 10G Media converters have three status LEDs located on the front panel of the unit PWR Power Test Green
2. Perle 10G Media Converters Installation Guide S 10G STS S 10G XTS S 10G XTX S 10G XTSH S 10G XTXH P N 5500325 10 Overview This document contains instructions necessary for the installation and operation of the Perle S 10G Standalone Media Converters The Perle S 10G Standalone Media Converters are 10 Gigabit Media Converters with two pluggable transceiver ports The S 10G supports low power transceivers whereas the S 10G XTSH and the S10G XTXH support high power power level 4 transceivers Model Port 1 Port 2 S 10G STS SFP SFP S 10G XTS XFP SFP S 10G XTSH XFP SFP S 10G XTX XFP XFP S 10G XTXH XFP XFP Note The S 10G Media Converter must be populated with two 1G fiber copper modules to operate at 1G Note2 When used with 1G modules the S 10G does not support the Loopback Auto Detect feature Visit Perle s web site for the most up to date Installation guides models and specifications http www perle com Getting to know your S 10G Media Converter Your S 10G Media Converter consists of the following items e S 10G chassis with two pluggable transceiver ports e Grounding screws for improved chassis grounding e Country specific power adapter e Power cord strain relief clip e Four rubber feet e This guide Perle S 10G Media Converter Installation Guide 2 Front and Rear Panel Components Front View Port 1 Port 2 LEDs XFPorSFP XFP or SFP Rear V
3. On Power is on and the unit is in normal operation mode Green blinking slowly the unit is in test or loopback mode Red blinking s owly while in Test mode indicates an error within the last second Red Solid During power up hardware error detected Red Blinking quickly Error detected See LK1 LK2 Error Codes Red Solid or Blinking A module has been inserted that is requesting more than the specified maximum power for that port Perle S 10G Media Converter Installation Guide 10 LK1 Port 1 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through Blinking one second on 3 seconds off the maximum specified operating temperature within the inserted module has been exceeded Off No fiber link present LK2 Port 2 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through Blinking one second on 3 seconds off the maximum specified operating temperature within the inserted module has been exceeded Off No fiber link present LK1 LK2 Error Codes LK1 LK2 Meaning Off Off Incompatible SFP or XFP or speed mismatch on SFP Off On Power Budget exceeded XFP s requesting more power than specified port rating On Off SFP or XFP communica
4. converter will need to be put into loopback mode See the documentation that came with that media converter Sequence of Events 1 The Local S 10G sends the Remote S 10G a signal to go into loopback mode 2 The Remote S 10G media converter turns on loopback mode 3 Built In Test data is sent from the Local S 10G media converter to the Remote S 10G media converter 4 The Remote S 10G media converter loops the received data back to the Local S 10G media converter 5 Anytesterrors detected are displayed with the LEDs on the front of the Local S 10G media converter 6 The Built in Link Tests continue to run until Switch 1 on the Local S 10G media converter is set to Data mode Port Selection Switch 3 Test Mode Switch Position Port Up default 1 Down 2 Fiber Fault Alert Switch 3 Data Mode Switch Position Mode Up default Enabled Down Disabled Enabled If the media converter detects a loss of fiber the media converter will immediately notify the fiber link partner that an error condition exists If the remote media converter is set up for Fiber Fault Alert FFA Enabled and the local media converter is set up with Smart Link Pass Through a loss of fiber link on either the transmit or receive line will be passed through to the other fiber connection Disabled The media converter will not monitor for fiber fault Perle S 10G Media Converter Installation Guide 8
5. the DIP switches varies by model so please refer to the appropriate model Note Switch changes made when the product is powered up take effect immediately and will result in a link reset on both ports Perle S 10G Media Converter Installation Guide 5 Operating Mode Switch 1 Switch Position Mode Up default Data Down Test Data In Data mode data will flow between the two fiber connections Test Test Mode is used to run diagnostics enable loopback and for running the Built In Link Tests Note The Operation Mode Switch 1 affects the function of DIP Switches 2 and 3 Link Mode Switch 2 Data Mode Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the link state on one fiber connection is directly reflected through the media converter to the other fiber connection If fiber link is lost on one of the connections then the other fiber link will be brought down by the media converter Standard Mode In this mode the links can be brought up and down independently of each other A loss of link on either fiber connection can occur without affecting the other fiber connection Perle S 10G Media Converter Installation Guide 6 Test Function Switch 2 Test Mode Switch Position Type Up default Built In Link Test Down Loopback Built In Link Test Switch 2 cau
6. A complaint Class 1 2 3 and 4 XFP modules for the S 10G XTXH and S 10G XTXSH e 1G copper modules e 1G fiber modules e SFP supports Cx1 direct attach interfaces e XFP supports CX4 modules Fiber Cabling Requirements MM 50 125 microns 62 5 125 microns SM 9 125 microns Note Please refer to the product page on the Perle website for the most up to date specifications http www perle com Perle S 10G Media Converter Installation Guide 15 Compliance Information FCC This product has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this Guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can
7. be found at the link below A Technical Support Query may be made via this web page www perle com support services support request shtml Warranty Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage Details can be found at http www perle com support_services warranty shtml Copyright 2012 Perle Systems Limited All rights reserved No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited Perle S 10G Media Converter Installation Guide 16
8. er are compatible v For fiber connections ensure the RX and TX have been reversed between the two media converters No connectivity If unable to get full connectivity with all DIP switches in the UP position this procedure is recommended for troubleshooting 1 Built In Link Test Set Switch 2 to the Up position 2 Set Switch 3 to the Up position to test port 1 or Switch 3 to the Down position to test Port 2 3 Loopback If the remote media converter is a Perle S 10G then the Local Perle S 10G media converter will signal the Remote media converter to go into loopback mode If the remote media converter is not a Perle S 10G then the remote media converter will need to be put into Loopback Mode See the User s Guide that came with that media converter 4 Test Data will be sent from the local S 10G to the Remote media converter 5 Ifthe PWR LED on the Local S 10G turns red or blinks red on a repeated basis the fiber connection may require further testing 6 If the PWR LED on the Local S 10G stays green after several seconds of testing then the link is passing the Built In Link Test Proceed to testing the other link P N 5500325 10 Module Temperature Protection Every S 10G comes equipped with an internal fan to provide cooling to the unit However if any of the modules are operating above their specified maximum operating temperature the S 10G will reduce the power to these modules The S 10G will continue to monito
9. iew ergs esi Power cord Grounding connector Lug Holes Power Cord Strain Relief Clip Hole Perle S 10G Media Converter Installation Guide Installation The default switch setting all switches in the UP position will work for most installations These are the steps required to configure the Perle S 10G standalone media converter 1 Setthe DIP switch settings optional Connect the grounding lug optional Connect the power cord strain relief clip optional Insert the fiber or copper modules Connect the fiber or copper cables on p oN Using the Perle supplied power adapter plug the power cord into the power cord connector at the rear of the chassis 7 Plug the other end of the power adapter into an appropriate power outlet Note The S 10G Chassis should always be grounded for safe and proper operation See Grounding the S10 G Chassis S 10G STS 1 Operating Mode 2 Link Mode Test Type 3 Fiber Fault Alert Test Mode Port 4 EDC Mode Port 1 5 EDC Mode Port 2 ON P N 5500325 10 S 10G XTS S 10G XTSH 1 Operating Mode 2 Link Mode Test Type 3 Fiber Fault Alert Test Mode Port 4 Not used 5 EDC Mode Port 2 S 10G XTX S 10G XTXH 1 Operating Mode 2 Link Mode Test Type 3 Fiber Fault Alert Test Mode Port 4 Not used 5 Not used DIP Switch Settings The DIP switches are accessible through the opening in the side of the enclosure The function of
10. r the operating temperature of the unit until the temperature is below the maximum operating temperature and then the S 10G will return the modules to normal operating Loopback Auto Detect Perle S 10G media converters have the ability to automatically put remote Perle S 10G media converters in loopback mode This allows the remote S 10G media converter to be located in distant or inaccessible locations The remote S 10G will remain in loopback mode as long as the tests are in progress Note Depending on the manufacturer some copper cabling may not support our Loopback Auto Detect feature however Loopback Mode can always be obtained by setting switch 2 to the down position on your Perle Media converter Perle S 10G Media Converter Installation Guide 14 Technical Specifications The following applies to all Perle Standalone S 10G Media converters Power Input Consumption 9 30VDC STS 1 0A Max 600mA at 12VDC XTS 1 2A Max 800mA at 12VDC XTX 1 5A Max 1 0A at 12VDC XTSH 1 5A Max 1 0A at 12VDC XTXH 2 0A Max 1 4A at 12VDC Operating Temperature OC 50 32F 122F Storage Temperature 250 70 13F 158F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Weight 0 38 kg 0 3 Ibs SFP and XFP Support e MSA Compliant SFP e MSA complaint Class 1 2 and 3 XFP modules for the S 10G XTX and S 10G XTS e MS
11. ses the S 10G to initiate the Built In Link Tests on the specified port Switch 3 determines the specified port for the Built In Link Tests If Switch 3 is Up the tests will be run on Port 1 If the Switch is Down the tests will be run on Port 2 The other port will be disabled during these tests These tests consist of the media converter module generating test patterns to be sent out the selected port to the remote media converter If the remote media converter is an S 10G it will automatically be put into loopback mode Loopback If Switch 2 is down the specified port will be put into loopback mode In this mode the port will be ready to receive the test patterns generated by the S 10G running the Built in Link Test Switch 3 determines which port will be put into loopback mode The other port will be disabled during the tests If the remote device is also an S 10G media converter this unit does not need to be put into test mode and there is no need to set the loopback switch This will be taken care of by the Auto Loopback feature Illustration of the Built In Link Test Loopback ge Local Remote S 10G S 10G _ gt Built In Link Test Loopback Mode Local S 10G Configuration Test Mode Switch 1 Down Test Fuction Switch 2 Up Remote S 10G Configuration All switches in the Up position Perle S 10G Media Converter Installation Guide 7 Note f the remote media converter is not a Perle S 10G then the remote media
12. tion error S 10G unable to communicate with module On On Internal Error Grounding the S10 G Chassis If your installation requires additional grounding follow this procedure Grounding the chassis requires the following items e One grounding lug not provided e One 18 12 AWG wire not provided Perle S 10G Media Converter Installation Guide 11 e Cross head screwdriver not provided Note For your safety when installing this equipment always ensure that the chassis ground connection is installed first and disconnected last Attaching the Grounding Lug F 1 Attach the grounding lug to one end of an 18 12 AWG wire 2 Attach the grounding lug to the chassis and secure with the grounding screw s Attaching the Power Cord Strain Relief Clip 1 Feed the power cord through the opening in the power cord relief clip 2 Attach the power cord relief clip to the chassis and secure with the provided screw 3 Plug the power cord into the AC power connector at the rear of the chassis 4 Plug the other end of the power cord into an appropriate power outlet Perle S 10G Media Converter Installation Guide 12 Troubleshooting General v Ensure power is supplied to the media converter use of the Perle supplied power adapter is highly recommended v Ensure that the SFP or XFP modules are of the same speed and are operating properly v Ensure both devices on either end of each fib