1. Edit Switch Dimmer ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 12 10 Click Done when finished 1 1 Click the RED X box on the top Welcome to IntelliTouch ScreenLogic Configuration right side of the dialog to exit the System Information Configuration setup dialog Controller Firmware 1 100 Protocol Adapter Version 4 0 1059 0 Protocol Adapter Name Pentair XX XX XX Configurator Version 4 0 Build 1059 0 Rel Configure Configure Configure ScreenLogic Video Lighting 12 Select the Video amp Lighting Protocol Adapter in the lower dialog box as shown below 13 Click the Start ScreenLogic button to start the ScreenLogic program LoL Pentairhelps make your Dream Pool become reality System Name Pentair xx xx xx mj nm ScreenLogic Video amp Remember Login Info Options Local Systems Adapter address Configure screertoge ScreenLogic Connect 4 0 Build 1141 0 Rel 14 Click the Lighting tab to access the LIGHTING screen CTE gees el Tuesday September 4 2007 6 09 PM e Lighting TF Spa i Pool Spa ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 13 Using the Light Interface The ScreenLogic light screen displays the following light s controls Click anywhere on the light bar to set the light intensity Click to switch Click to switch light OFF
2. Panasonic video camera Models BL C1A BL C111A BB HCM311A BB HCM331A KX HCM110A BB HCM381A Note Panasonic video cameras are widely available for sale on the Internet Powerline Control Systems PulseWorx PCS models pes Note PCS light switches TON m are compatible with incondescent light bulbs only Lights with florescent light bulbs cannot be Powerline used Interface Module PIM Powerline Interface Module Wall Switch Dimmer 600W PIM Model PIM R Model WS1D6 Serial Interface Note PCS light switches are widely available on the Internet Refer to the following links htto www hometech com brains upb html PO PIMR http www hometech com modules upb html PO WS1D6W ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide ScreenLogic Video and Lighting Protocol Adapter Connection Diagram 2 woy y punoJe P eq jouueo sqinq punoj s uowMws 14Dr1 SOd jy6y juoosesoy srry IN6ga a yum s 4617 uo sqinq 4481 jueosepuooul Jaidepe e npo N YIM ejquieduioo fod ov soot ae AA euijewog a s i peuinbayJ Jeydepy SI U9JIMS YIOMION oo0jo4d BunuDr 9 euondo ue p Aib xew oepiA oiboqueeg0S fi woo SeJouJeo puonippe 104 NV 1 J9UJe2 r XX XX XX Xoug Jrejuog Je1depy 090 01d oiboqueeJoS Hunsixy 191noy SSOIOIIM g gp H zu Oo HEB Soosooooes a iei M Ist e ScreenLogic Vid
3. Area Y Note Available camera controls will vary by camera ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 10 Installing Lights for the first time Have the Powerline Interface module ready to connect to COM 1 port on the ScreenLogic Video amp Lighting Protocol adapter during the program installa tion setup Each light switch must be setup one at a time A WARNING All switches work must be installed by a licensed electrician and must conform to the National Electric Code and all national state and local codes To install the PCS Light switches Note PCS light switches are compatible with incondescent light bulbs only Lights with florescent light bulbs cannot be used 1 Click the ScreenLogic Connect icon on your desktop The following screen will be displayed 2 Be sure that the Video amp Lighting adapter is selected and is populated in the system name field i creenLogic Connec ol 3 Click the la ils a ME x Configure ScreenLogic Pentairchelps make your button Dream Pool become reality System name XX XX XX p gt system Name Pentair xx xx xx ScreenLogic system lt La password eee Remember Login Info Options lt lt Local Systems ScreenLogic Video amp gt Panlsimeccs i9216823 80 Configure IP Info Lighting Protocol Adapter address Configure ScreenLodic ScreenLogic Connect 4 0 Build
4. can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications not expressly approved by the party responsible for FCC compliance could void the user s authority to operate the equipment A IC Regulatory Notice Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device 2008 Pentair Water Pool and Spa Inc All rights reserved 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 800 553 5000 IntelliTouch ScreenLogic and Pentair Water Pool and Spa are registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or
5. light ON ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide Pentair Water Pool and Spa P N 520936 Rev A
6. registered trademarks of those parties or others P N 520936 Rev A 03 03 2008 ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide ScreenLogic Video and Lighting Protocol Adapter Connection Diagram 2 Connecting the ScreenLogic Video amp Lighting Protocol Adapter Installing the ScreenLogic Video amp Lighting protocol adapter Configuring the System Configuring the Video Camera s for the first time Using the Video Camera Interface Installing the Lights for the first time Using the Lights Interface ScreenLogic Video amp Lighting Protocol Adapter Using the SceenLogic Video amp Lighting Protocol adapter with your existing ScreenLogic system you can control up to four color video cameras to monitor your pool spa and home areas via your ScreenLogic interface device or PC at home or remotely over the Internet Also using a Lighting Powerline Interface Module you can control any number of outside and inside lights Features e Remotely monitor your property via video cameras e Control outside lights pathway front door entry hallway stairwells garage entryway etc e Control lights inside the home e Log on anywhere via your laptop or PC for full control e Compatible with all IntelliTouch systems Supported Video Cameras and Light Switches The following video camera models and Powerline Control systems are supported for use with the ScreenLogic Video amp Lighting Protocol adapter
7. the Video amp Lighting protocol adapter to port 1 2 3 or 4 on your wireless router 2 Run setup exe on the installation CD 3 Follow the prompts to update or install ScreenLogic Connect Installing the system for the first time Have the camera s cable s ready to connect to the ScreenLogic Video amp Lighting Protocol adapter during the program installation setup Each camera must be setup one at a time To setup the ScreenLogic Video amp Lighting Protocol adapter for the first time 1 Click the ScreenLogic Connect icon on your desktop The screen shown below will be displayed Note The default IP address for the Video amp Lighting Protocol adapter is 192 168 2 3 If necessary you can view and configure the Video amp Lighting Protocol Adapter IP settings by clicking the Configure IP Info button 2 Clickthe Configure ScreenLogic button ScreenLogic Connect fel x Pentalr helpsmakeyour Dream Pool become reality System Mame Pentair XX XX XX d ScreenLogic system Password se password Start Scresntoge Remember Login Info Options lt lt Local Systems Screen Log ic Video amp Pentair xx xx xx 192 168 2 3 80 Configure IP Info L g hti i g j rotoco Configure ScreenLogic Adapter IP address _ Configure Scere ScreenLogic Connect 4 0 Build 1141 0 Rel ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 3 The software wil
8. 1141 0 Rel Pentair XX XX XX ScreenLogic Configurator m o Welcome to IntelliTouch ScreenLogic Configuration System Information Controller Firmware 1 100 Protocol Adapter Version 4 0 1059 0 Protocol Adapter Name Pentair xx xx XXx Configurator Version 4 0 Build 1059 0 Rel 4 Click the Configure Lighting button to configure the lights Configure Configure Configure ScreenLogic Video Lighting i ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 5 11 Click the Add New button Configure Lighting Installed Switches Dimmers Add New Edit Switch Dimmer Press the light switch five 5 times in the ON position The green LED on the light switch will start blinking rapidly which indicates that the light is ready to be configured See page 2 for connection diagram Click the OK button on the message dialog box HLCONFIG Put the new device in setup mode and press OK to continue Tap device 5 times quickly to enter setup mode Rename the light in the Name box Use a name that describes where the light is located Click the OK button The light setup procedure will take about one minute for each light fixture Add New Lighting Device Name Kitchen Light To setup additional lights click the Add New button and repeat steps 6 9 Configure Lighting Installed Switches Dimmers Kitchen Light Add New
9. 4 Intelli ch pool spa control system ScreenLogic Video amp Lighting Protocol Adapter Pool Spa Lighting User s and Installation Guide Pentair Water Pool and Spa i ScreenLogic Video amp Lighting Protocol Adapter kit contents The following items are included in the kit Kit contents e ScreenLogic Video amp Lighting Protocol Adapter P N 5208542 e AC DC power adapter e RJ45 cable e DB9M to RJ45 adapter e Users and Installation Guide this manual Technical Support Sanford North Carolina 8 A M to 5 P M ET Moorpark California 8 A M to 5 P M PT Phone 800 831 7133 Fax 800 284 4151 Related manuals Download the IntelliTouch ScreenLogic User s Guide P N 520493 at http www pentairpool com siteimages ScreenLogic Users Guide pdf A FCC Regulatory Safety Notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which
10. eo amp Lighting Protocol Adapter User s and Installation Guide Connecting the ScreenLogic Video amp Lighting Protocol Adapter The following describes how to connect the Video amp Lighting Protocol adapter to an existing ScreenLogic system 1 Connect the provided RJ45 CAT5 cable to an available port 1 2 3 or 4 on the ScreenLogic wireless router Connect the other end of the cable to the LAN port on the Video amp Lighting Protocol adapter see diagram on page 2 2 Lights cable connection Connect an RJ45 CAT5 cable to the COM 1 port on the adapter Connect the other end of the cable to the DB9M RJ45 adapter Connect the DB9M RJ45 adapter to the RS 232 connector that is connected to the UPB Powerline Interface Module PIM See diagram on page 2 3 Camera cable connection Connect AC power plug to the video camera s Connect the RJ45 camera cable to port 1 2 3 or 4 on the ScreenLogic wireless router see diagram on page 2 If additional cameras are being installed a Network Switch can be used to provide available ports ScreenLogic supports a maximum of four cameras see diagram on page 2 ScreenLogic Video amp Lighting Protocol Adapter Name The Video amp Lighting Protocol adapter system name is identified on the Screen as Pentair xx Xx xx where xx xx xx are the last six 6 digits of the unit s serial number which can be found on a sticker on the adapter The name is displayed on the ScreenLogic Con
11. fore proceeding Configure Configure Configure ScreenLogic Video Lighting TT 2 Click the Configure Video button to Configure Video x configure the camera eile tame 3 Click the Add New Camera button AddNew Camera ai 4 Click the OK button on the message aE dialog box Ensure that the camera was E plugged in within the last 20 minutes pO HLCONFIG Camera detection and address changing can only be performed A within 20 minutes of camera power up ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 9 Select the camera manufacture and model and click the OK button Add New Video Camera Note Only configure Detected Video Cameras one camera at a time Panasonic BL C104 K HCM10 230 250 270 BB Nw For example connect Panasonic BL C14 BB MWC111 the first camera then Panasonic BL C30 amp BB NwE111 configure it Plug in the second camera and repeat Select the installed video camera model to rename the camera and set its IP address The cameras IP address must be in the same subnet range as your ScreenLogic Video amp Lighting Protocol Adapter The default IP address for the ScreenLogic Video amp Lighting Protocol Adapter is 192 168 2 3 It is recommended that you select a higher IP address to avoid conflict on your network For example use 192 168 2 80 for camera No 1 192 168 2 81 for camera No 2 etc Configure Video In
12. l configure the smaller ScreenLogic Protocol Adapter for use with Semar ooo sentes Coifiguaar I E em the Video amp Lighting Protocol Adapter A Welcome to nteliTouch ScreenLogic Configuration System Configuration Complete i sl ll message box will be displayed Click OK Sen P to continue with the installation Please be patient while the Video amp Lighting Protocol adapter synchronizes the settings from the IntelliTouch system for the first time This can take anywhere from 3 to 15 minutes depending upon the complexity of your IntelliTouch system HLCONFIG P System Configuration Complete Configure Synchronize Configure Configure ScreenLogic House Address Video Lighting Note When synchronizing is complete the TT current system information is displayed in the dialog box see dialog on right Configuring the Video Camera s for the First Time To configure the video camera s for the first time TRETTEREEUEEUZJE Welcome to IntelliTouch ScreenLogic Configuration System Information Item Information Controller Firmware 1 100 Protocol Adapter Version 4 0 1059 0 Protocol Adapter Name Pentair XX XX XX Configurator Version 4 0 Build 1059 0 Rel 1 Connect the RJ45 camera cable to the ScreenLogic Wireless Router port 1 2 3 or 4 and plug in the camera See page 2 for connection diagram Please allow the video camera 45 seconds to power up be
13. nect dialog as shown below Pentair helpsmake yours Dream Pool become reality Check this box to save the if _ current login information UP Pentair Brick 192 168 2 2 80 is the existing ScreenLogic Protocol Adapter IP address oo EmEEENN Do not configure this adapter Remember Login Info Options lt lt Local Systems f Pentair Brick xx xx xx 192 168 2 2 80 Configure IP Info ScreenLogic Video amp Lighting Pentair xx xx xx 192 168 2 3 80 Protocol Adapter name Sea ScreenLogic Connect 4 0 Build 1141 0 Rel ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 4 Installing the ScreenLogic Video amp Lighting protocol adapter Before installing the ScreenLogic software make sure that you are running the latest version The latest software version for ScreenLogic can be obtained from the Pentair website at http www pentairpool com techinfo instructions htm Note If an existing ScreenLogic system is not present please install the standard ScreenLogic system first as described in the User s Guide provided with ScreenLogic Once installed please follow the directions below Follow the two step process to install the ScreenLogic Video amp Lighting protocol adapter Step 1 Updating the small protocol adapter Note This step is not required for a brand new ScreenLogic system Please proceed to STEP 2 below 1 A
14. o Options lt lt ScreenLogic Video amp Local Systems I i Pentair xx xx xx 192 168 2 3 80 EN Lighting Protocol Mss ore Adapter address Configure ScreenLogic ScreenLogic Connect 4 0 Build 1141 0 Rel Tuesday September 4 2007 6 09 PM Note Please note it may take a few minutes for the video camera to complete its EE configuration for the first time before the video appears A Pool Spa Patchy Fog Patchy Fog Partly Cloudy Partly Cloudy Partly Cloudy Partly Cloudy ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide Using the Video Camera Interface The ScreenLogic Video amp Lighting Protocol Adapter supports up to four video cameras Each camera can be accessed by clicking the camera s name tab at the bottom of the Video screen Each camera has its own set of controls Camera controls include Full Screen Monitor in full screen mode e Low Med High Set the camera resolution e 1 2 3 4 5 6 7 8 Preset camera positions This feature is not supported on the BL C1A camera e Camera zoom out and in out e Click inside the image to center the camera to that point e Navigation Controls Move camera up down left and right Installed camera s Click on the tab along the bottom of the screen to access the camera s Note This feature is not supported on all cameras Pool Spa Lighting d GERE EP GS E05 ES Front Gate Pool
15. stalled Video Cameras Add New Camera Delete Camera Edit Camera Information Name Pool Camera IP Address f 32 158 272 Apply M For additional cameras click the Add New Camera button and repeat steps 1 6 Click Done when finished The Configuration setup dialog box will be displayed ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide 8 9 Click the RED X box on the top right side of the dialog to exit the Configuration setup dialog J Pentair xx xx xx ScreenLogic Configurator NJ m X Welcome to IntelliTouch ScreenLogic Configuration System Information Controller Firmware 1 100 Protocol Adapter Version 4 0 1059 0 Protocol Adapter Name Pentair XX XX XX Configurator Version 4 0 Build 1059 0 Rel Configure Configure Configure ScreenLogic Video Lighting ES E 10 Click on the Video amp Lighting Protocol adapter in the Local System box then click START Note If the Video amp Lighting adapter does not show up under the Local Systems you can manually type in the adapter s IP address in the System Name field The adapter s default IP address is 192 168 2 3 ScreenLogic Connect Woe Pentairhelss make yours 11 Click the Dream Podl become reality Start ScreenLogic button to start the ScreenLogic program System Name Pentair XX XX XX Password Start ScreenLogic i Remember Login Inf
16. ttach your protocol adapter to the wireless router port 1 2 3 or 4 2 Make sure that the Video amp Lighting protocol adapter is NOT plugged in during this process 4 Run pentairupdate exe on the installation CD 5 The following program dialog will appear with the small protocol adapter listed 4 ScreenLogic Update Local Systems Click on the Pentair Brick 192 168 2 2 80 Pentair Brick 192 168 2 2 80 Select ScreenLogic system above and click start If no systems appear in the list check network settings and try again NOTE This PC must be on the same network subnet to perform this upgrade Start 5 Click on the Pentair Brick 192 168 2 2 80 and click Start The update program will convert your small protocol adapter for use with the new Video amp Lighting protocol adapter Updating System a Formatting Flash File System Please Wait OK Connection LIDP Downloader FOUND POOL 4 0 Build 1258 0 Rel Sent RAM Loader Run command to target Looking For RAM loader Sent ping to 192 168 2 2 RAM Loader found Total Progress XemProgess BBBEBREEEEEE MEE MENN ScreenLogic Video amp Lighting Protocol Adapter User s and Installation Guide Step 2 Updating or installing ScreenLogic Connect software on your PC ScreenLogic Connect is the program that will allow you to configure and operate your IntelliTouch pool spa control system 1 Connect