1. 1620 Hawkins Ave Sanford NC 27330 919 774 4151 Pool Products 10951 West Los Angeles Ave Moorpark CA 93021 805 523 2400 Because reliability matters most Rev D 2 19 04 1 P N 520041 SECTIONI APPLICATION Used in conjunction with Compool CP100 and EasyTouch Control Systems Provides switching of four remote control circuits from a wireless hand held remote Itis typically used for activating the spa circulation and for operating three auxiliary pieces of equipment suchas lights jetpump air blower waterfall etc Each of the four functions on the hand held remote has an ON and an OFF button SECTIONIL KITINCLUDES l qty Hand held Remote P N 520018 l qty Receiver with 8 ft flexible conduit with 2 97 ft cables inside 4 qty Plastic Anchors for mounting Receiver toa flat surface 4 qty Mounting screws for mounting Receiver toa flat surface SECTIONIT RECEIVER The functional range of the wireless remote from Hand held Remote to Receiver is approximately 150 ft line of sight The Receiver should be mounted at a convenient location ona flat surface aminimum of 5 ft above ground level to optimize the functional range of the Hand held Remote ACAUTION The Receiver should be mounted a minimum of 8 to 10 feet away from any air blower which may be part of the equipment set The Receiver will not operate properly if it is close to a blower which is operating In order to mount the Receiv
2. will shut off in approximately 30 minutes Note Both Spa and Aux Time Out mode can be enabled at the same time Automatic Time Out settings for Spa and Aux circuits Rev D 2 19 04 5 P N 520041 SECTIONXI CUSTOMIZING THE COMMUNICATION LINK The communication link between the Receiver and Hand held Remote can be customized to prevent electrical interference To accomplish this there is a 10 position configuration switch located on the Receiver circuit board and inside the Hand held Remote Units are shipped from the factory with all switches in the ON position Ifyou wish to change this setting use the corner ofa paper clip or other blunt instrument and adjust both 10 position configuration switches to matching settings Ifthe configuration switch setting atthe Receiver does not match that of the Hand held Remote the communication link will not function Labels have been provided marked with the most commonly used functions These labels may be affixed to the side of the Hand held Remote to assist with button identification u P h a wsoojsamanaoau du FE 1 8 be Oxe XNIT 000i 20 12345678910 OL6E 8L9NSvVETL Receiver Transmitter COMMUNICATION LINK ADJUSTMENT NOTE All Prog
3. or connection to the LX Control Center Defective Receiver board Address switches are incorrectly configured Transmitter battery has failed Defective Transmitter or Receiver Circuit selection switches are incorrectly set Undue electrical noise Too many obstructions between the Transmitter and Receiver Receiver unit is too near the ground A near by home is operating a similar wireless unit Undue electrical noise is being produced by one or more pieces of equipment in close proximity to the Receiver Transmitter battery is failing Insure power is being supplied and that the LX Control Center operates correctly without the Receiver installed Verify the function of the board using known good cable set Contact Factory or Service center Verify the function of the board using known good cable set Contact factory or service center Verify that the address switches on the Transmitter and Receiver board are correct and match Replace Transmitter battery Contact Factory or Service center Verify settings of SW1 through SW4 on the Receiver board Relocate the Receiver away from operate equipment such as blower motors Relocate the Receiver in a location that provides fewer obstructions to the area the user commonly operates the Transmitter Relocate the Receiver to maximize the distance between the Receiver antenna and the ground Select a an alternate address code for the Transmitter an
4. EZ100 EASYTOUCH OWNER S MANUAL 4 Function Hand Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I SECTION II SECTION SECTION IV SECTION V POWER ISOLATION CIRCUIT BOARD SECTION VI CABLE SPLITTERS OPTIONAL SECTION VII HAND HELD REMOTE SECTION VIII USING THE HAND HELD REMOTE SECTION IX RECEIVER CIRCUIT BOARD SECTION X AUTOMATIC COUNTDOWN CYCLE OPTIONAL SECTION XI CUSTOMIZING THE COMMUNICATION LINK SECTION XH TRANSMITTER BATTERY REPLACEMENT SECTION XIII TROUBLESHOOTING AWARNING Before installing this product read and follow all warning notices and instructions which are included Failure to follow safety warnings and instructions can result in severe injury death or property damage Call 800 831 7133 for additional free copies of these instructions Important Notice Attention Installer This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment IMPORTANT The Hand held remote may be used with wet hands but should never be submersed in water as this could damage the unit If accidental submersion occurs dry unit out by removing battery cover and removing battery Position unit so that water can drain out Reassemble when completely dry Pentair Pool Products gt Pentair
5. ates an Indoor Remote it will be necessary to use a Cable Splitter for Socket 1 See SECTION VI CABLE SPLITTERS Optional SECTIONVI CABLESPLITTERS Optional Ifthe Control System incorporates an Indoor Remote disconnect any existing Indoor Remote cables from Socket 1 It will be necessary to use a Cable Splitter P N 6CONDDUAL to connect to the Power Center circuit board Plug the short cable attached to single connector end of each Cable Splitter into Socket 1 Plug the cable from the Indoor Remote and the silver cable from the receiver into the Cable Splitter sockets SECTION VII HAND HELD REMOTE The Hand held Remote will control four circuits SPA button activates the Spa circuit duplicates Spa Button on Optional Indoor Remote A button activates Auxiliary circuit duplicates Button 1 on Optional Indoor Remote B button activates Auxiliary 2 circuit duplicates Button 2 on Optional Indoor Remote C button activates Auxiliary 3 circuit duplicates Button 3 on Optional Indoor Remote Each of the four functions on the hand held remote has an ON and an OFF button Itis possible to incorporate a 30 minute or 90 minute countdown cycle for the Spa and or Auxiliary 1 circuit usefulif Aux is used fora jet pump or air blower In this instance whenever those circuits are turned on they will automatically shut down at the end of the countdown cycle without having to push the OFF button In o
6. d Receiver i e change the switches on both boards to an alternate but matching setting Relocate the Receiver away from equipment such as blower motors OR relocate the Receiver in a location that provides fewer obstructions to the area the user commonly operates the Transmitter Replace Transmitter battery P N 520041 SAVE THESE INSTRUCTIONS Pentair Pool Products gt Pentair 1620 Hawkins Ave Sanford NC 27330 919 774 4151 Pool Products 10951 West Los Angeles Ave Moorpark CA 93021 805 523 2400 Because reliability matters most P N 520041 Rev D 2 19 04
7. er it will be necessary to remove the two retaining screws located on the underside of the Receiver and carefully slide the Receiver case up and offofits backplate Temporarily position the backplate against its mounting surface so that the Receiver is oriented in an upright position with antenna pointing upwards and flexible conduit protruding from the bottom of the Receiver The circuit board may need to be temporarily removed Carefully disconnect the modular connectors at the bottom of the circuit board and slide the board out of the backplate Use a pencil to mark the four mounting points For mounting to stucco walls drill 3 16 in dia holes Insert the four plastic anchors provided Reposition the backplate over the mounting points and secure with the four mounting screws provided Carefully slide the circuit board back into the backplate and connect the modular connectors with the silver cable connector attached to Socket 1 SILVER and the black cable connector attached to Socket 2 Then slide the Receiver case back onto the backplate and secure using the two retaining screws P N 520041 2 Rev D 2 19 04 SECTIONIV POWERCENTER AWARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION If your Compool electrical panel includes circuit breakers almond colored steel enclosure it is also required that the main power into the home be switched off at the main circuit breaker box Before starting the installation process disconnect
8. f of Spa and or Auxl1 DEPI Nn Communication Link Adjustment Adjustable code settings between Receiver and Hand held remote Receiver Overview 12345678910 P N 520041 4 Rev D 2 19 04 SECTION X AUTOMATIC COUNTDOWN CYCLE OPTIONAL There is a4 position configuration switch designated S2 located on the Receiver circuit board This switch can be used to set a countdown cycle time out feature for the Spa and or Aux 1 circuit Once this feature has been enabled the equipment will automatically turn offafter the countdown cycle irrespective ofhow the circuit was turned on by Indoor Remote Spa side Remote or Hand held Remote Use a paper clip or other blunt instrument to slide the appropriate switch at S2 to the ON or OFF position inaccordance with the following pictorial EEE J POET 1 94v 2 y3a81e 2087 2 g F Di q 12103 ciel Factory Setting All Off No time out for Spa or Aux1 H 8Lt dxY 000LL L07 GE leow E alie TEE tE Spa will shut off in approximately 90 minutes Spa will shut off in approximately 30 minutes Aux will shut off in approximately 90 minutes Aux
9. power by switching off all circuit breakers to all associated pool and spa equipment Failure to do so may lead to severe electrical shock which can result in death or severe personal injury Loosen the LOCK SCREW on handle ofhinged faceplate in left side of Power Center and swing open to expose the low voltage wiring compartment Ifthe Power Center incorporates a circuit breaker subpanel it will be necessary to temporarily remove the breaker panel in order to access the low voltage wiring compartment Insert the flexible conduit attached to Receiver into the low voltage compartment by threading through the plastic bushing on the underside of the Power Center enclosure SECTION V POWERISOLATION CIRCUIT BOARD Locate the two cables one silver and one black protruding from the flexible conduit Each cable has amodular connector attached Ifthe Control System incorporates an Indoor Remote disconnect any cables going to Socket 2 of the Power Center circuit board Plug the short cable BLACK from the Power Isolation circuit board into Socket 2 Plug the black cable from the RF receiver into the socket marked EZ WIRELESS of the Power Isolation circuit board The Power Isolation PCB has an additional socket to accommodate the Indoor Remote cable from Socket 2 marked CP 100 Ifthere is no Indoor Remote the silver cable for the receiver may be plugged directly into Socket 1 of the Power Center circuit board Ifthe Control System incorpor
10. ram Switches are Factory set to ON Matching Code Example Remote switches 2 4 6 ON Receiver switched 2 4 6 ON SECTION XII TRANSMITTER BATTERY REPLACEMENT Withnormal use the battery should last for several years In the event the battery must be replaced slide the cover from the bottom of the Hand held Remote Slide the battery from the retainer clip and discard in accordance with local and or state ordinances Replace with 3V lithium battery number CR2032 or equivalent Slide battery cover onto remote and snap in place P N 520041 6 Rev D 2 19 04 SECTION XII TROUBLESHOOTING POWER LED does not light COM LINK LED does not light or blink In normal operation LED will blink at least every 2 seconds COMMAND LED does not light when Transmitter button s is pressed unit fails to operate Unit functions but some circuits do not work or operate the incorrect circuit Unit fails to operate or fails to dependably at range Unit seems to turn on or off circuits without the user Transmitter Unit dependably turns equipment ON but once equipment is running it does not dependably turn equipment OFF or range is greatly reduced when equipment is running Unit operates but has greatly reduced range compared to prior function Rev D 2 19 04 LX Control Center does not have power Defective cable or connection to the LX Control Center Defective Receiver board Defective cable
11. rder to incorporate the countdown feature itis necessary to make adjustments to the circuit board located inside the Receiverunit SECTION VIII USING THE HAND HELD REMOTE To activate a circuit press and hold the appropriate ON button for at least a full second To deactivate press and hold the OFF button in the same manner Rev D 2 19 04 3 P N 520041 SECTIONIX RECEIVER CIRCUIT BOARD Toaccess the circuit board inside the Receiver remove the two retaining screws located on the underside of the Receiver and slide the Receiver case up and off of its backplate On the circuit board you will discover the following 1 A4 position configuration switch designated S2 which can be used to configure an automatic countdown cycle for the Spa and or Aux circuit 2 A 10 position configuration switch designated S1 which can be used to customize the communication link between the Receiver and Hand held Remote 3 2 qty status lights designated POWER and COMMAND which are used for trouble shooting POWER Indicates that the Control System is supplying power to the Receiver unit COMMAND Flashes whenever a button is pushed on the Hand held Remote Power Indicator Lamp Indicates control system is supplying power to Receiver HJ 8Lv AXY EEUWEN EEM IEE 000LL 107 t Command Indicator Lamp Flashes whenever a signal is received from Hand held Remote 30 90 Minute Shut Off s2 Time out adjustment for auto shut of

Download Pdf Manuals

image

Related Search

Related Contents

Metro 130XT-2 RCH Metro 130XT  Bedienungsanleitung  Furuno 1945 Marine RADAR User Manual    Philips AE1506/00 User's Manual  Bedienungsanleitung  User Manual User Manual User Manual User Manual User Manual  Home Decorators Collection 1672600910 Instructions / Assembly  fongicide Switch vs oïdium ds concombre de serre  LG Electronics 660T Flat Panel Television User Manual  