1. 1 01 INSTALLATION The Spectra II dome and Spectra Lite dome shipping cartons contain three boxes Inspect each box to make sure all parts are present IN CEILING MODELS Back Box 1 Back box 1 Parts bag 1 Conduit fitting 1 Safety chain bracket 1 Lock nut 1 Compass tool 4 T rail clip clip L bracket screw lock washer and nut Dome Drive 1 Dome drive Lower Dome 1 Acrylic lower dome with trim ring BACK BOX COMPASS TOOL SAFETY BRACKET O T RAIL CLIP Pelco Installation Manual C1487M H 1 01 PENDANT MODELS Back Box 1 Back box 1 Tube of thread compound Dome Drive 1 Dome drive Lower Dome 1 Acrylic lower dome with trim ring 1 Parts bag O ring and lubricant and tube of Loctite BACK BOX DOME DRIVE THREAD LOCTITE O RING COMPOUND 222MS LUBE O RING HARD CEILING INSTALLATION IN CEILING MODELS STEP 1 PREPARE CEILING a Locate the center point of the mounting location Drill a hole in b Draw a circle on the ceiling using the compass tool and a the ceiling using a 3 32 inch drill Insert the compass tool into pencil Cut the circle out of the ceiling the hole STEP 2 INSTALL THE BACK BOX ATTACH SAFETY CHAIN HERE a Attach the conduit fitting lock nut and safety chain bracket b Turn the thumb screw and open the hinged door to the back Install a safety chain cable not supplied that will support up box Pull wiring into
2. refer to the 7 oub e i shooting section SPECTRA Il ONLY verserenee i NOTE Aux 1 Maximum 2A at low voltage lt 40V ON i Aux 2 Maximum 150 vA at 32 VDC i SWITCHES 45 voc WIRING EXAMPLE NO RELAY NC AUX 1 LOGIC GATE WIRING EXAMPLE GROUND HEATER FAN NOT USED EXTERNAL RELAY WIRING EXAMPLE 12 Pelco Installation Manual C1487M H 1 01 STEP 4 INSTALL DOME DRIVE SWI sw2 ACER i dob e CO RS 422 TERMINATION SWITCH 00368 a Set the DIP switches for SW1 and SW2 on the bottom of the last unit in the chain farthest from the controller To terminate dome drive for the appropriate receiver address Refer to the the dome drive set the RS 422 termination switch to the left labels on the dome drive or Tables C through E in the Appen dix in the back of this manual c Line up the green and red tabs with the green and red labels Push in on the tabs Insert the side with the green tab then the b Daisy Chain Operation Only When connecting more than side with red tab Continue pushing on the ends of the tabs one Spectra dome system to a single controller terminate the until both sides click into place STEP 5 INSTALL LOWER DOME MOUNTING RETAINER SCREW HOLES SCREW FRONT amp BACK a Lightly apply O ring lubricant to the O ring Install the O ring in b Attach the back box trim leash to the lo
3. Control ssi a 16 Switch Settings for SW2 D Typ6e Gonlrol eorr rri a 16 Pelco Installation Manual C1487M H 1 01 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by qualified service personnel and conform to all local codes 2 Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 3 Only use replacement parts recommended by Pelco 4 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry 5 The installation method and materials should be capable of supporting four times the weight of the enclosure pan tilt camera and lens combination The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within CAUTION this unit RISK OF ELECTRIC SHOCK This symbol indicates that there are important DO NOT OPEN operating and maintenance instructions in the literature accompanying this unit Please thoroughly familiarize yourself with the information in this manual prior to installation and operation MEASURE
4. Horizontal Angle of View Spectra Il 16X 18X 22X Spectra Lite MTBF 16X 18X 22X Spectra Lite Focus NTSC Spectra Il dome drive models DD5BC DD5BC22 and DD5BCBW PAL Spectra Il dome drive models DD5BC X DD5BC22 X and DD5BCBW X NTSC Spectra Lite dome drive model DD5TAC PAL Spectra Lite dome drive model DD5TAC X 2 1 interlace 1 4 inch interline transfer CCD 768 H 752 H 510 H 500 H x 494 x 582 x 492 x 582 V V V V gt 470 TV lines 470 TVL NTSC 460 TVL PAL F1 4 F1 4 F1 6 F1 6 4 mm to 64 mm optical 4 1 mm to 73 8 mm optical 4 mm to 88 mm optical 3 9 mm to 63 mm optical 16X optical zoom 8X electronic zoom 18X optical zoom 4X electronic zoom 22X optical zoom 8X electronic zoom 16 optical zoom Auto manual speed selection 47 at 4 mm wide zoom 3 at 64 mm telephoto zoom 48 at 4 1 mm wide zoom 2 7 at 73 8 mm telephoto zoom 47 at 4 mm wide zoom 2 at 88 mm telephoto zoom 45 at 3 9 mm wide zoom 3 at 63 mm telephoto zoom gt 2 million cycles at room temperature gt 500 000 cycles at room temperature gt 2 million cycles at room temperature gt 1 million cycles at room temperature zoom focus irs zoom focus irs zoom focus irs zoom focus irs a Automatic and manual override Pelco Installation Manual C1487M H 1 01 Sensitivity Spectra Il 16X 18X 22X Spectra Lite Sync System White B
5. MC3651H 2 and MC3651H 2X camera models when returned which have a five year warranty Method of return shipment shall be the same or equal to the method by which the item was Two years on standard motorized or fixed focal length lenses received by Pelco e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series RETURNS fixed dome products In order to expedite parts returned to the factory for repair or credit please call the factory at Two years on Spectra Esprit ExSite and PS20 scanners including when used in 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned continuous motion applications for credit and RA number if returned for repair Two years on Esprit and WW5700 Series window wiper excluding wiper blades All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products Goods returned for repair or credit should be clearly identified with the assigned CA or RA ne year except video heads on video cassette recorders VCRs Video heads will be number and freight should be prepaid Ship to the appropriate address below covered for a period of six months If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Si
6. in the Appen dix in the back of this manual b Daisy Chain Operation Only When connecting more than one Spectra dome system to a single controller terminate the last unit in the chain farthest from the controller To terminate the dome drive set the RS 422 termination switch to the left STEP 4 INSTALL LOWER DOME a Snap the clip on the end of the trim ring leash into the hole on the lip of the back box b Line up the snaps on the trim ring with the mounting screws on the back box Snap the trim ring into the plastic snap washers on the mounting screws TO USE YOUR DOME REFER TO THE OPERATION AND PROGRAMMING MANUAL Pelco Installation Manual C1487M H 1 01 24 VAC POWER TRANFORMER 24 VAC ONLY CONTROLLER COAXITRON CONTROLLER VIDEO OUT 2 WIRE CONTROLLER CONTROL RS 422 INPUTS SPECTRA Il ONLY seseeeee E DOADN 7 GROUND NO RELAY NC AUX 1 SWITCHES 45 vpc WIRING EXAMPLE HEATER FAN NOT USED Line up the green and red tabs with the green and red labels Push in on the tabs Insert the side with the green tab then the side with red tab Continue pushing on the ends of the tabs until both sides click into place PENDANT MOUNT INSTALLATION PENDANT MODELS STEP 1 MOUNT AND INSTALL THE BACK BOX NOTE If installin
7. peak and auto sharpness options for Spectra Lite Added white balance hue option for Spectra Lite and removed R B and M G white balance options for Spectra Lite Revised Spectra Lite camera specifications C1487M E 9 99 Replaced the standard Spectra Il DD5AC and DD5AC X cameras with model DD5BC and DD5BC X LowLight color cam eras Added optional 176X color models Revised main menu access documentation to include the KBD4000 KBD4002 KBD4000V keyboards Added material on LowLight limit Revised material on shutter speed and zoom Added material on zone overlap and priorities Revised color camera specifications C1487M F 3 00 Separated into two manuals Installation Manual and Operation and Programming Manual C1487M G 5 00 Added information on Spectra Il Color Black and White C1487M H 1 01 Added step to dome drive installation instructions referencing the new RS 422 termination switch Revised specifications and certifications Pelco the Pelco logo Spectra Genex Legacy and Coaxitron are registered trademarks of Pelco O Copyright 2001 Pelco All rights reserved TM Spectra Il Spectra Lite Esprit and Camclosure are trademarks of Pelco U S Patent No 5 931 432 Loctite is a registered trademark of Loctite Corporation
8. that is compatible with Pelco s CM6700 MPT9500 CM8500 and Genex controllers or with American Dynamics control systems using the AD2083 Translator P type control is RS 422 that is compatible with Pelco s CM6700 CM9750 CM9760 and Genex control systems OFF Use with controllers that have more than 32 presets ON Use with American Dynamics controllers 32 presets OFF Use with all control systems except CM9502 with variable speed keyboards For CM9502 with fixed speed keyboards set switch OFF ON Use with CM9502 with variable speed keyboards for smoother joystick control Pelco Installation Manual C1487M H 01 01 Table D Switch Settings for SW2 P Type Control NOTE For Coaxitron controls SW2 is not used set all switches OFF For D type control systems refer to Table E Receiver Switch Setting Receiver Switch Setting Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 1 OFF OFF OFF OFF OFF 17 OFF OFF OFF OFF ON 2 ON OFF OFF OFF OFF 18 ON OFF OFF OFF ON 3 OFF ON OFF OFF OFF 19 OFF ON OFF OFF ON 4 ON ON OFF OFF OFF 20 ON ON OFF OFF ON 5 OFF OFF ON OFF OFF 21 OFF OFF ON OFF ON 6 ON OFF ON OFF OFF 22 ON OFF ON OFF ON 7 OFF ON ON OFF OFF 23 OFF ON ON OFF ON 8 ON ON ON OFF OFF 24 ON ON ON OFF ON 9 OFF OFF OFF ON OFF 25 OFF OFF OFF ON ON 10 ON OFF OFF ON OFF 26 ON OFF OFF ON ON 11 OFF ON OFF ON OFF 27 OFF ON OFF ON ON 12 ON ON OFF ON OFF 28 O
9. the conduit fitting lock nut and safety chain bracket b Turn the thumb screw and open the hinged door to the back Install a safety chain cable not supplied that will support up box Pull wiring into the back box through the conduit fitting to 16 pounds 7 3 kg Refer to Tables A and B in the Appendix for wiring distances T RAIL CLIP B FOR B CEILING TILE TRAILCLIP E _ L4 h c Compress the spring clips on the back box and push it through d Install the ceiling tile with the back box Attach a T rail clip on the hole until the clips spring back Tighten the screws until each side of the ceiling tile Fasten the L bracket to the clip you hear a clicking noise with the supplied screw and washers 8 Pelco Installation Manual C1487M H 1 01 e Attach the wiring to the circuit board inside the back box When finished close the door to the back box and turn on the power The red LED will light IMPORTANT If the LED does not light refer to the 7 oub e shooting section NOTE Aux 1 Maximum 2A at low voltage lt 40V Aux 2 Maximum 150 vA at 32 VDC 5 to 24 VDC LOGIC GATE o WIRING EXAMPLE EXTERNAL RELAY WIRING EXAMPLE RS 422 TERMINATION SWITCH a Set the DIP switches for SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address Refer to the labels on the dome drive or Tables C through E
10. 0 OFF OFF ON ON ON OFF ON ON 173 ON OFF ON ON OFF ON OFF ON 221 ON OFF ON ON ON OFF ON ON 174 OFF ON ON ON OFF ON OFF ON 222 OFF ON ON ON ON OFF ON ON 175 ON ON ON ON OFF ON OFF ON 223 ON ON ON ON ON OFF ON ON 176 OFF OFF OFF OFF ON ON OFF ON 224 OFF OFF OFF OFF OFF ON ON ON 177 ON OFF OFF OFF ON ON OFF ON 225 ON OFF OFF OFF OFF ON ON ON 178 OFF ON OFF OFF ON ON OFF ON 226 OFF ON OFF OFF OFF ON ON ON 179 ON ON OFF OFF ON ON OFF ON 227 ON ON OFF OFF OFF ON ON ON 180 OFF OFF ON OFF ON ON OFF ON 228 OFF OFF ON OFF OFF ON ON ON 181 ON OFF ON OFF ON ON OFF ON 229 ON OFF ON OFF OFF ON ON ON 182 OFF ON ON OFF ON ON OFF ON 230 OFF ON ON OFF OFF ON ON ON 183 ON ON ON OFF ON ON OFF ON 231 ON ON ON OFF OFF ON ON ON 184 OFF OF OFF ON ON ON OFF ON 232 OFF OFF OFF ON OFF ON ON ON 185 ON OFF OFF ON ON ON OFF ON 233 ON OFF OFF ON OFF ON ON ON 186 OFF ON OFF ON ON ON OFF ON 234 OFF ON OFF ON OFF ON ON ON 187 ON ON OFF ON ON ON OFF ON 235 ON ON OFF ON OFF ON ON ON 188 OFF OFF ON ON ON ON OFF ON 236 OFF OFF ON ON OFF ON ON ON 189 ON OFF ON ON ON ON OFF ON 237 ON OFF ON ON OFF ON ON ON 190 OFF ON ON ON ON ON OFF ON 238 OFF ON ON ON OFF ON ON ON 191 ON ON ON ON ON ON OFF ON 239 ON ON ON ON OFF ON ON ON 192 OFF OFF OFF OFF OFF OFF ON ON 240 OFF OFF OFF OFF ON ON ON ON 193 ON OFF OFF OFF OFF OFF ON ON 241 ON OFF OFF OFF ON ON ON ON 194 OFF ON OFF OFF OFF OFF ON ON 242 OFF ON OFF OFF ON ON ON ON 195 ON ON OFF OFF OFF OFF ON ON 243 ON ON OFF OFF ON ON ON ON 196 OFF OF ON OFF O
11. Class A The following applies to the DD5AM DD5BC and DD5TAC models FCC Class B This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help The following applies to the DD5BC22 model FCC Class A This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
12. DRIVE SWI RS 422 TERMINATION SWITCH ss a Set the DIP switches for SW1 and SW2 on the bottom of the last unit in the chain farthest from the controller To terminate dome drive for the appropriate receiver address Refer to the the dome drive set the RS 422 termination switch to the left labels on the dome drive or tables C through E in the Appendix in the back of this manual c Line up the green and red tabs with the green and red labels Push in on the tabs Insert the side with the green tab then the b Daisy Chain Operation Only When connecting more than side with red tab Continue pushing on the ends of the tabs one Spectra dome system to a single controller terminate the until both sides click into place STEP 4 INSTALL LOWER DOME j MOUNTING RETAINER SCREW HOLES SCREW FRONT amp BACK a Lightly apply O ring lubricant to the O ring Install the O ring in b Attach the back box trim leash to the lower dome Use retainer the groove on the trim ring of the lower dome screw nearest to a mounting screw inside lower dome NOTE If you are install ing an outdoor model plug the two pin heater connection in the lower dome into the mating connector in the back box c Remove the two lower dome mounting screws Apply a drop d Push the lower dome inside the back box line up the mounting of Loctite 222MS supplied to each screw screw holes and install the two mounting screws TO USE YOUR DOME R
13. EFER TO THE OPERATION AND PROGRAMMING MANUAL Pelco Installation Manual C1487M H 1 01 11 SURFACE MOUNT INSTALLATION PENDANT MODELS STEP 1 REMOVE THE TOP PORTION OF THE BACK BOX a Turn the thumbscrew and open the b Unscrew the three Phillips screws lo c Remove the top portion of the back box hinged door located inside the back box cated underneath the hinged door STEP 2 PREPARE SURFACE AND INSTALL THE BACK BOX NOTE If installing outdoors apply a sealant between the back box and the mounting surface a Determine the mounting location Use the base of the back box as a template Mark the fastener and center hole positions onto the mounting surface b Drill a hole in the center of the mounting surface Pull wiring through the opening Refer to Tables A and B in the Appendix for wiring distances Prepare the holes for the fasteners Position the back box over the mounting holes and pull wiring into the back box Secure the back box to the mounting surface using the appropriate hardware for your installation POWER 24 VAC ONLY STEP 3 WIRE CIRCUIT BOARD CONTROLLER COAXITRON CONTROLLER HT vineo our RX RX CONTROL TX RS 422 Attach the wiring to the interconnect circuit board inside the back WIRE box Close the door to the back box Turn on power to the back CONTROLLER box The red LED will light n IMPORTANT If the LED does not light
14. F OFF ON OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 38 OFF ON ON OFF OFF ON OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 39 ON ON ON OFF OFF ON OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 40 OF OFF OFF ON OFF ON OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 46 OF ON ON ON OFF ON OFF OFF 23 ON ON ON OFF ON OFF OFF OFF 47 ON ON ON ON OFF ON OFF OFF 24 OFF OFF OFF ON ON OFF OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF Continued on next page 16 Pelco Installation Manual C1487M H 01 01 Table E Switch Settings for SW2 D Type Control continued Receiver Switch Setting Receiver Switch Setting Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 49 ON OFF OFF OFF ON ON OFF OFF 105 ON OFF OFF ON OFF ON ON OFF 50 OFF ON OFF OFF ON ON OFF OFF 106 OFF ON OFF ON OFF ON ON OFF 51 ON ON OFF OFF ON ON OFF OFF 107 ON ON OFF ON OFF ON ON OFF 52 OFF OFF ON OFF ON ON OFF OFF 108 OF OFF ON ON OFF ON ON OFF 53 ON OFF O
15. FF OFF ON ON 244 OFF OFF ON OFF ON ON ON ON 197 ON OFF ON OFF OFF OFF ON ON 245 ON OFF ON OFF ON ON ON ON 198 OFF ON ON OFF OFF OFF ON ON 246 OFF ON ON OFF ON ON ON ON 199 ON ON ON OFF OFF OFF ON ON 247 ON ON ON OFF ON ON ON ON 200 OFF OFF OFF ON OFF OFF ON ON 248 OFF OFF OFF ON ON ON ON ON 201 ON OFF OFF ON OFF OFF ON ON 249 ON OFF OFF ON ON ON ON ON 202 OFF ON OFF ON OFF OFF ON ON 250 OFF ON OFF ON ON ON ON ON 203 ON ON OFF ON OFF OFF ON ON 251 ON ON OFF ON ON ON ON ON 204 OFF OFF ON ON OFF OFF ON ON 252 OFF OFF ON ON ON ON ON ON 205 ON OFF ON ON OFF OFF ON ON 253 ON OFF ON ON ON ON ON ON 206 OFF ON ON ON OFF OFF ON ON 254 OFF ON ON ON ON ON ON ON 207 ON ON ON ON OFF OFF ON ON 208 OFF OF OFF OFF ON OFF ON ON 18 Pelco Installation Manual C1487M H 1 01 SPECIFICATIONS MECHANICAL Construction Back box Dome drive Lower dome Cable Entry In Ceiling Pendant Pan Movement Vertical Tilt Manual Pan Tilt Speeds Pan Spectra Il Spectra Lite Tilt Spectra Il Spectra Lite Preset Speeds Pan Tilt Aluminum Aluminum ABS plastic Acrylic 75 inch 1 91 cm conduit fitting Through 1 5 inch 3 81 cm NPT pendant mount 360 continuous pan rotation Unobstructed 2 to 92 0 1 80 sec manual operation 150 sec turbo 0 5 80 sec manual operation 150 sec turbo 0 1 40 sec 0 5 40 sec 250 sec 200 sec For variable speed operation an appropriate controller is required Wi
16. N OFF ON ON OFF OFF 109 ON OFF ON ON OFF ON ON OFF 54 OFF ON ON OFF ON ON OFF OFF 110 OFF ON ON ON OFF ON ON OFF 55 ON ON ON OFF ON ON OFF OFF 111 ON ON ON ON OFF ON ON OFF 56 OFF OF OFF ON ON ON OFF OFF 112 OFF OFF OFF OFF ON ON ON OFF 57 ON OFF OFF ON ON ON OFF OFF 113 ON OFF OFF OFF ON ON ON OFF 58 OFF ON OFF ON ON ON OFF OFF 114 OF ON OFF OFF ON ON ON OFF 59 ON ON OFF ON ON ON OFF OFF 115 ON ON OFF OFF ON ON ON OFF 60 OFF OF ON ON ON ON OFF OFF 116 OFF OFF ON OFF ON ON ON OFF 61 ON OFF ON ON ON ON OFF OFF 117 ON OFF ON OFF ON ON ON OFF 62 OFF ON ON ON ON ON OFF OFF 118 OFF ON ON OFF ON ON ON OFF 63 ON ON ON ON ON ON OFF OFF 119 ON ON ON OFF ON ON ON OFF 64 OFF OF OFF OFF OF OFF ON OFF 120 OF OFF OFF ON ON ON ON OFF 65 ON OFF OFF OFF OFF OFF ON OFF 121 ON OFF OFF ON ON ON ON OFF 66 OFF ON OFF OFF OFF OFF ON OFF 122 OFF ON OFF ON ON ON ON OFF 67 ON ON OFF OFF OFF OFF ON OFF 123 ON ON OFF ON ON ON ON OFF 68 OFF OFF ON OFF OFF OFF ON OFF 124 OF OFF ON ON ON ON ON OFF 69 ON OFF ON OFF OFF OFF ON OFF 125 ON OFF ON ON ON ON ON OFF 70 OFF ON ON OFF OFF OFF ON OFF 126 OFF ON ON ON ON ON ON OFF 71 ON ON ON OFF OFF OFF ON OFF 127 ON ON ON ON ON ON ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 128 OFF OFF OFF OFF OFF OFF OFF ON 73 ON OFF OFF ON OFF OFF ON OFF 129 ON OFF OFF OFF OFF OFF OFF ON 74 OFF ON OFF ON OFF OFF ON OFF 130 OF ON OFF OFF OFF OFF OFF ON 75 ON ON OFF ON OFF OFF ON OFF 131 ON ON OFF OFF OFF OFF OFF ON 76 OFF OF ON ON OFF OFF ON OFF 132 OFF OFF ON
17. N ON OFF ON ON 13 OFF OFF ON ON OFF 29 OFF OFF ON ON ON 14 ON OFF ON ON OFF 30 ON OFF ON ON ON 15 OFF ON ON ON OFF 31 OFF ON ON ON ON 16 ON ON ON ON OFF 32 ON ON ON ON ON Baud Rate Switch Setting SW2 6 SW2 7 SW2 8 2400 OFF OFF OFF 4800 ON OFF OFF 9600 OFF ON OFF Table E Switch Settings for SW2 D Type Control NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table D Receiver Switch Setting Receiver Switch Setting Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 1 ON OFF OFF OFF OFF OFF OFF OFF 25 ON OFF OFF ON ON OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 26 OFF ON OFF ON ON OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 28 OF OFF ON ON ON OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 8 OFF OF OFF ON OFF OFF OFF OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 34 OF ON OFF OFF OFF ON OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 37 ON OFF ON OF
18. OFF OFF OFF OFF ON 77 ON OFF ON ON OFF OFF ON OFF 133 ON OFF ON OFF OFF OFF OFF ON 78 OFF ON ON ON OFF OFF ON OFF 134 OFF ON ON OFF OFF OFF OFF ON 79 ON ON ON ON OFF OFF ON OFF 135 ON ON ON OFF OFF OFF OFF ON 80 OFF OFF OFF OFF ON OFF ON OFF 136 OF OFF OFF ON OFF OFF OFF ON 81 ON OFF OFF OFF ON OFF ON OFF 137 ON OFF OFF ON OFF OFF OFF ON 82 OFF ON OFF OFF ON OFF ON OFF 138 OFF ON OFF ON OFF OFF OFF ON 83 ON ON OFF OFF ON OFF ON OFF 139 ON ON OFF ON OFF OFF OFF ON 84 OFF OFF ON OFF ON OFF ON OFF 140 OFF OFF ON ON OFF OFF OFF ON 85 ON OFF ON OFF ON OFF ON OFF 141 ON OFF ON ON OFF OFF OFF ON 86 OFF ON ON OFF ON OFF ON OFF 142 OF ON ON ON OFF OFF OFF ON 87 ON ON ON OFF ON OFF ON OFF 143 ON ON ON ON OFF OFF OFF ON 88 OFF OF OFF ON ON OFF ON OFF 144 OFF OFF OFF OFF ON OFF OFF ON 89 ON OFF OFF ON ON OFF ON OFF 145 ON OFF OFF OFF ON OFF OFF ON 90 OFF ON OFF ON ON OFF ON OFF 146 OFF ON OFF OFF ON OFF OFF ON 91 ON ON OFF ON ON OFF ON OFF 147 ON ON OFF OFF ON OFF OFF ON 92 OFF OFF ON ON ON OFF ON OFF 148 OF OFF ON OFF ON OFF OFF ON 93 ON OFF ON ON ON OFF ON OFF 149 ON OFF ON OFF ON OFF OFF ON 94 OFF ON ON ON ON OFF ON OFF 150 OFF ON ON OFF ON OFF OFF ON 95 ON ON ON ON ON OFF ON OFF 151 ON ON ON OFF ON OFF OFF ON 96 OFF OFF OFF OFF OFF ON ON OFF 152 OFF OFF OFF ON ON OFF OFF ON 97 ON OFF OFF OFF OFF ON ON OFF 153 ON OFF OFF ON ON OFF OFF ON 98 OFF ON OFF OFF OFF ON ON OFF 154 OF ON OFF ON ON OFF OFF ON 99 ON ON OFF OFF OFF ON ON OFF 155 ON ON OFF ON ON OFF OFF
19. ON 100 OFF OFF ON OFF OFF ON ON OFF 156 OFF OFF ON ON ON OFF OFF ON 101 ON OFF ON OFF OFF ON ON OFF 157 ON OFF ON ON ON OFF OFF ON 102 OFF ON ON OFF OFF ON ON OFF 158 OFF ON ON ON ON OFF OFF ON 103 ON ON ON OFF OFF ON ON OFF 159 ON ON ON ON ON OFF OFF ON 104 OFF OFF OFF ON OFF ON ON OFF 160 OF OFF OFF OFF OFF ON OFF ON Continued on next page Pelco Installation Manual C1487M H 01 01 17 Table E Switch Settings for SW2 D Type Control continued Receiver Switch Setting Receiver Switch Setting Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 Address SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 161 ON OFF OFF OFF OFF ON OFF ON 209 ON OFF OFF OFF ON OFF ON ON 162 OFF ON OFF OFF OFF ON OFF ON 210 OFF ON OFF OFF ON OFF ON ON 163 ON ON OFF OFF OFF ON OFF ON 211 ON ON OFF OFF ON OFF ON ON 164 OFF OFF ON OFF OFF ON OFF ON 212 OFF OFF ON OFF ON OFF ON ON 165 ON OFF ON OFF OFF ON OFF ON 213 ON OFF ON OFF ON OFF ON ON 166 OFF ON ON OFF OFF ON OFF ON 214 OFF ON ON OFF ON OFF ON ON 167 ON ON ON OFF OFF ON OFF ON 215 ON ON ON OFF ON OFF ON ON 168 OFF OFF OFF ON OFF ON OFF ON 216 OFF OFF OFF ON ON OFF ON ON 169 ON OFF OFF ON OFF ON OFF ON 217 ON OFF OFF ON ON OFF ON ON 170 OFF ON OFF ON OFF ON OFF ON 218 OFF ON OFF ON ON OFF ON ON 171 ON ON OFF ON OFF ON OFF ON 219 ON ON OFF ON ON OFF ON ON 172 OFF OF ON ON OFF ON OFF ON 22
20. PELLO m Ill ll a Nu SD5 Series Spectra II and Spectra Lite Dome Systems Installation Manual C1487M H 1 01 Pelco e 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com In North America and Canada Tel 800 289 9100 FAX 800 289 9150 International Customers Tel 1 559 292 1981 e FAX 1 559 348 1120 Pelco Installation Manual C1487M H 1 01 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNING S crisi abile sleale ae 4 INSTALLATION Stai HERES HARD CEILING INSTALLATION i a Br SUSPENDED CEILING INSTALLATION PENDANT MOUNT INSTALLATION n daa ir si n SURFAGE MOUNT INSTALLATION iio cavesncteuee den eaa DAR EE Ee daina NEEE Ee TROUBLESHOOTING iio aaa 14 ARPEND CRE lei idas 15 SPECIFICATIONS ESF 19 CERTIFICATIONS AND REGULATORY NOTICES anni rir ttp erdt ta ta rca End ra vers ce Rates 23 WARRANTY AND RETURN INFORMATION 24 LIST OF ILLUSTRATIONS Figure 1 LIST OF TABLES Table Muou gt Page SD5 Series Dimension DrawiG r 22 catch dpi epe E rait co e te cc p pe Dated i d c d der ated 20 Page Video Coaxial CableWiring Distances uu rece tir desc os 15 24 VAC Wiring Distances ssi ies sa 15 Switch Settings for SW1 15 Switch Settings for SW2 P Type
21. S DE SECURITE IMPORTANTES Avant d installer ou d utiliser ce produit les mesures de s curit suivantes sont prendre 1 Toute installation et r paration devraient tre entreprises par un technicien qualifi et conformes au codes locaux 2 A moins que cet equipement indique avoir un boiti agr e NEMA de type 3 3R 3S 4 4X 6 ou 6P il est uniquement con u pour utilisation int rieure et ne peut donc pas tre en contact de pluie ou d humidit 3 Utiliser seulement les pi ces de rechanges recommand es par Pelco 4 Apr s toute installation ou r paration de la partie lectrique de ce produit une r sistance entre le courant et la partie expos e devrait tre install e afin de v rifier que la partie lectrique n aie pas t en contact d un court circuit 5 L installation entreprise et le mat riel utilis devraient supporter quatre fois le poids du boiti de la tourelle de la cam ra et de la lentille Ce produit et ou le manuel pourrait inclurent les symbols suivants Ce symbol indique qu un voltage dangereux pouvant provoquer un chock lectrique est pr sant dans cette unit CAUTION RISQUE DE CHOQUE LECTRIQUE Ce symbol indique qu il y a des mesures NE PAS OUVRIR d installation et d entretient importantes inclus dans le manuel de cet quipement Nous vous prions de bien vous familiarisez avec la manuel avant d entreprendre toute installation 4 Pelco Installation Manual C1487M H
22. alance Shutter Speed Models DD5BC DD5BC22 and DD5AM DD5BC X DD5BC22 X and DD5AM X DD5BCRW DD5BCBW X DD5TAC DD5TAC X Iris Control Spectra Il Spectra Lite Gain Control Video Output NTSC PAL Signal to Noise Ratio 05 lux at 1 2 second shutter speed 2 lux at 1 4 second shutter speed color 013 lux at 1 4 second shutter speed black amp white 07 lux at 1 1 5 second shutter speed 1 lux at f1 6 at signal level of 40 IRE gain high AGC on AC line lock phase adjustable via remote control Automatic with manual override 1 2 1 30 000 1 1 5 to 1 30 000 1 4 to 1 10 000 1 3 to 1 10 000 1 60 to 1 10 000 1 50 to 1 10 000 Automatic with manual override Automatic with manual override Automatic with manual override 714V 07V 100 IRE 10 IRE IN x 07V gt 46 dB MONOCHROME Spectra Only Signal Format Scanning System Image Sensor Horizontal Resolution Effective Pixels EIA CCIR Lens Minimum f stop Focal Length Zoom Ratio Horizontal Angle of View MTBF Focus Sensitivity EIA CCIR Signal Process Sync System 22 EIA model DD5AM CCIR model DD5AM X 2 1 interlace 1 4 inch interline transfer CCD gt 500 TV lines 768 H x 494 V 752 H x 582 V F1 4 4 mm to 64 mm optical 16X optical zoom 8X electronic zoom 47 at 4 mm wide zoom 3 at 64 mm telephoto zoom gt 2 million cycles at room temperatu
23. co c o Expeditors he above warranty provides the Dealer with specific legal rights The Dealer may also have Par duri CA 94080 USA additional rights which are subject to variation from state to state Phone 650 737 1 700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C1487M 7 98 Original version C1487M A 11 98 Revised the manual to incorporate Spectra Lite material Added material on CCIR and EIA monochrome cameras and PAL color camera Revised material in Section 5 11 21 2 Programming Limit Stops Revised Section 6 0 Troubleshooting Changed the fixed speed controller rate in Section 8 0 Specifications C1487M B 2 99 Changed Spectra Lite model numbers and added comments that the line sync feature is not functional for the DD5T C model of Spectra Lite Changed power specifications for indoor models from 25 vA to 30 vA and for outdoor models from 90 vA to 75 vA Revised maximum temperature operating ranges Revised color camera specifications 3 99 Changed auto iris material to include Spectra Lite as well as Spectra Il C1487M C 7 99 Added a note relating to running patterns when an alarm activates Changed the preset tilt speed from 100 to 200 degrees second Added model number and specifications for Spectra Lite PAL camera Revised manual to new format C1487M D 7 99 Changed Spectra Lite camera zoom from 12X to 16X Changed line sync and auto focus material to include Spectra Lite as well as Spectra II Removed auto iris
24. elco Installation Manual C1487M H 01 01 APPENDIX Table A Video Coaxial Cable Wiring Distances Cable Type Maximum Distance RG59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Minimum cable requirements 75 ohms impedance All copper center conductor 95 braided copper shield Table B 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Wire Gauge 20 18 16 14 12 10 30 vA 94 ft 150 ft 238 ft 380 ft 603 ft 960 ft 28 m 45 m 115 m 72 m 183 m 292 m 75 VA 37 ft 60 ft 95 ft 152 ft 241 ft 384 ft 11 m 18 m 29 m 46 m 73 m 117 m NOTE Input power for the dome is 24 VAC only Power consumption is 30 vA per dome for indoor models and 75 vA for outdoor models Use a 24 VAC transformer with the following minimum vA For indoor models without heater For outdoor models with heater 40 vA per dome 100 vA per dome Table C Switch Settings for SW1 Control Type Switch Setting SW1 1 SW1 2 Sw1 3 SW1 4 SW1 5 SW1 6 SW1 7 Sw1 8 Coaxitron OFF OFF OFF OFF OFF OFF OFF OFF P Type Control ON OFF OFF OFF OFF OFF OFF OFF D Type Control OFF ON OFF OFF OFF OFF OFF OFF NOTES Switches SW 1 3 through SW 1 6 MUST be OFF D type control is RS 422
25. g outdoors make sure the installation is properly sealed to keep moisture out a Install the mount for the pendant dome Refer to the instruc tions supplied with the mount Bring the wiring for the dome through the mount Refer to Tables A and B in the Appendix for wiring distances c Pull wiring from the mount into the back box STEP 2 WIRE CIRCUIT BOARD Attach the wiring to the interconnect circuit board inside the back box Close the door to the back box Turn on power to the back box The red LED will light IMPORTANT If the LED does not light refer to the Trouble shooting section NOTE Aux 1 Maximum 2A at low voltage lt 40V Aux 2 Maximum 150 vA at 32 VDC 10 b Turn the thumbscrew and open the hinged door located inside the back box d Screw the back box into the mount If outdoors apply thread compound provided to the threads on the back box 24 VAC TRANFORMER POWER 24 VAC ONLY CONTROLLER COAXITRON CONTROLLER VIDEO OUT 2 WIRE CONTROLLER CONTROL RS 422 INPUTS ROUND NO RELAY NC AUX 1 SWITCHES 45 voc WIRING EXAMPLE E D Zo DQ mo xo 2 2 Dm 3 m i44 IT GROUND Q Aux2 E H HEATER FAN NOT USED EXTERNAL RELAY WIRING EXAMPLE Pelco Installation Manual C1487M H 1 01 STEP 3 INSTALL DOME
26. in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Pelco Installation Manual C1487M H 1 01 23 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or workmanship for a period of one year after the date of shipment 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Exceptions to this warranty are as noted below 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number e Five years on FT FR8000 Series fiber optic products 3 Details of the defect or problem Three years on Genex Series products multiplexers server and keyboard If there is a dispute regarding the warranty of a product which does not fall under the Three years on Camclosure and fixed camera models except the CC3701H 2 warranty conditions stated above please include a written explanation with the product CC3701H 2X CC3751H 2 CC3651H 2X
27. ower Dome See Figure 1 NEMA Type 1 In ceiling back boxes all dome drives NEMA Type 4X Pendant back boxes IP 66 Pendant back boxes Unit Shipping 2 6 lb 1 18 kg 4 lb 1 81 kg 2 65 Ib 1 20 kg 5 lb 2 27 kg 19 Ib 09 kg 1 lb 45 kg 2 85 Ib 1 28 kg 5 lb 2 27 kg Add 1 25 lbs 57 kg for heater and sun shield 2 65 Ib 1 20 kg 5 Ib 2 27 kg 1 30 Ib 59 kg 2 20 Ib 1 0 kg Add 25 lbs 11 kg for heater TOP PORTION OF BACK BOX IS REMOVABLE FOR SURFACE TO CEILING BY MOUNT APPLICATIONS 8 52 7 25 18 13 e 6 60 16 76 I DOME IS SECURED MOUNTING BRACKET 20 L 5 90 14 99 8 25 20 96 gt NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 1 SD5 Series Dimension Drawing 21 64 I AAA A I 6 75 17 15 10 90 27 69 5 83 14 80 x Y Y Y 5 90 14 99 Pelco Installation Manual C1487M H 1 01 CAMERAS COLOR Spectra Il and Spectra Lite Signal Format Scanning System Image Sensor Effective Pixels NTSC Spectra Il PAL Spectra Il NTSC Spectra Lite PAL Spectra Lite Horizontal Resolution Spectra Il Spectra Lite Lens Minimum f stop Spectra Il 16X 18X 22X Spectra Lite Focal Length Spectra Il 16X 18X 22X Spectra Lite Zoom Ratio Spectra Il 16X 18X 22X Spectra Lite Digital Slow Shutter
28. rcuit board Make sure that all connections are fully seated and the board is wired correctly b Check the DIP switch settings on the dome drive refer to Tables C D and E If the unit still does not operate turn off power and replace the dome drive with a good unit if you have a spare Check the switch settings on the substi tute dome drive before installing it If you do not have a spare return the dome drive and back box to the factory If you substituted a dome drive and the unit operates the original dome drive is bad return the dome drive to the factory If the unit still does not operate then the circuit board is bad return the back box to the factory Fan does not operate Fan connections are not fully seated Make sure the connector for the fan is fully seated If the fan still does not operate return the back box and dome drive to the factory for repair Vertical roll on monitor when switching between cameras Cameras are out of phase If you are wiring more than one dome to the same transformer it is important to wire the power con nector in each dome the same way That is the wiring from one side of the transformer must be connected to the same connector on each dome DOME 1 WARNING Make ui sure you wire power to the outer connec tors of the terminal block and ground to DOME 2 the middle connec POWER tor Otherwise you could damage the dome DOME 3 POWER 14 P
29. re zoom focus iris Automatic with manual override 1 lux at f1 4 AGC gain 26 5 dB signal level 40 IRE without IR cut filter 1 lux at f1 4 AGC gain 29 5 dB signal level 300 mV without IR cut filter DSP 3R AC line lock phase adjustable via remote control Pelco Installation Manual C1487M H 1 01 Shutter Speed Automatic electronic iris manual ElA 1 60 1 30 000 CCIR 1 50 1 30 000 Iris Control Automatic with manual override Gain Control Automatic with manual override Video Output ElA 714V 07V 100 IRE 10 IRE CCIR IN x 07V Signal to Noise Ratio gt 46 dB Manual control of camera setup functions can be done with CM6700 CM8500 CM9500 CM9760 and MPT9500 controllers but not with CM7500 MPT9000 or KBD9000 controllers Design and product specifications subject to change without notice CERTIFICATIONS AND REGULATORY NOTICES CE Class A models DD5BC X and DD5BC22 X CE Class B models BB5A F BB5A PB BB5A PG BB5A PG E BB5T F BB5T PB BB5T PG BB5T PG E DD5TAC X DD5AM X and DD5BCBW X Model BB5A PSG E Pending UL CUL models BB5A F BB5A PB BB5A PG BB5A PG E DD5AM BB5T F BB5T PB BB5T PG BB5T PG E DD5TAC DD5BC DD5BC22 and DD5BCBW Model BB5A PSG E Pending FCC Class A model DD5BC22 FCC Class B models DD5AM DD5BC DD5TAC and DD5BCBW Suitable for use in environmental air handling spaces BB5A F and BB5T F FCC Class B meets more stringent requirements than FCC
30. th fixed speed controllers Spectra Il and Spectra Lite pan tilt speed is 24 sec The CM6700 controller with the KBD200 keyboard has programmable fixed speeds ELECTRICAL Input Voltage Input Power In ceiling Indoor pendant Outdoor pendant Fuse 1 6A Relay Contacts Type Voltage Current GENERAL Environment In Ceiling Pendant Operating Range In Ceiling Pendant Without Heater With Heater 18 30 VAC 24 VAC nominal 30 vA 30 vA 75 VA AUX 1 AUX 2 Output Form C Open collector transistor output Low voltage lt 40 V 32 VDC maximum 2 A maximum 150 mA maximum Indoor only Indoor outdoor 32 to 140 F 0 to 60 C intermittent operation 32 to 122 F 0 to 50 C continuous operation 32 to 140 F 0 to 60 C absolute maximum operating temperature 32 to 122 F 0 to 50 C sustained maximum operating temperature Assumes no wind chill factor for detailed test conditions contact Pelco Maximum operating temperature 140 F 60 C absolute maximum 122 F 50 C sustained maximum Minimum operating temperature 60 F 51 11 C absolute minimum minimal icing at 50 F 45 56 C sustained minimum prevents icing at 40 F 40 C sustained minimum de ices 1 inch 2 5 mm within 3 hours after power up Pelco Installation Manual C1487M H 1 01 19 Dimensions Ratings Weight In Ceiling Back Box Dome Drive Lower Dome Pendant Back Box Dome Drive L
31. the back box through the conduit fitting to 16 pounds 7 3 kg Refer to Tables A and B in the Appendix for wiring distances CEILING TILE c Compress the spring clips on the back box and push it through the hole until the clips spring back Tighten the screws until you hear a clicking noise 6 Pelco Installation Manual C1487M H 1 01 d Attach the wiring to the circuit board inside the back box When finished close the door to the back box and turn on the power The red LED will light IMPORTANT If the LED does not light refer to the 7 oub e shooting section NOTE Aux 1 Maximum 2A at low voltage lt 40V Aux 2 Maximum 150 vA at 32 VDC ae STEP 3 INSTALL DOME DRIVE SWI SW2 SEE FECE 3 S ero a LABEL sw2 SADT ls co RS 422 TERMINATION SWITCH SETA a Set the DIP switches for SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address Refer to the labels on the dome drive or Tables C through E in the Appen dix in the back of this manual b Daisy Chain Operation Only When connecting more than one Spectra dome system to a single controller terminate the last unit in the chain farthest from the controller To terminate the dome drive set the RS 422 termination switch to the left STEP 4 INSTALL LOWER DOME a Snap the clip on the end of the trim ring leash into the hole on the lip of the back box b Line up
32. the snaps on the trim ring with the mounting screws on the back box Snap the trim ring into the plastic snap washers on the mounting screws TO USE YOUR DOME REFER TO THE OPERATION AND PROGRAMMING MANUAL Pelco Installation Manual C1487M H 1 01 EXTERNAL RELAY bd WIRING EXAMPLE 24 VAC POWER TRANFORMER 24 VAC ONLY CONTROLLER COAXITRON CONTROLLER VIDEO OUT RX RX CONTROL TX RS 422 2 WIRE CONTROLLER INPUTS ROUND NO RELAY NC AUX 1 GROUND Q aux2 i WITCHES G EXAMPLE HEATER FAN NOT USED Line up the green and red tabs with the green and red labels Push in on the tabs Insert the side with the green tab then the side with red tab Continue pushing on the ends of the tabs until both sides click into place SUSPENDED CEILING INSTALLATION IN CEILING MODELS STEP 1 PREPARE CEILING TILE NOTE The ceiling tile cannot be thinner than 0 50 inch 1 27 cm or thicker than 1 75 inches 4 45 cm a Remove the ceiling tile from the ceiling Insert the compass tool supplied into the center of the tile If necessary use a 3 32 inch bit to drill a hole b Draw a circle on the tile using the compass tool and a pencil Cut the circle out of the ceiling tile STEP 2 INSTALL THE BACK BOX ATTACH SAFETY CHAIN HERE a Attach
33. wer dome Use the the groove on the trim ring of the lower dome retainer screw nearest to a mounting screw inside lower dome NOTE If you are install ing an outdoor model plug the two pin heater connection in the lower dome into the mating connector in the back box c Remove the two lower dome mounting screws Apply a drop d Push the lower dome inside the back box line up the mounting of Loctite supplied to each screw Screw holes and install the two mounting screws TO USE YOUR DOME REFER TO THE OPERATION AND PROGRAMMING MANUAL Pelco Installation Manual C1487M H 1 01 13 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate The controller is not communicating with the Spectra unit Check to see if the red LED on the circuit board in the back box is lit 1 The red LED is not lit a Fuse is bad b 24 VAC power source is not con nected or back box is bad 2 The red LED is lit a Wiring is incorrect or is not fully seated b DIP switch settings are incorrect a Check fuse on the circuit board Replace fuse if itis bad To order a fuse from Pelco specify the part number FUS1 6 5X20FAST This is a 1 6 ampere fuse 5 x 20 mm fast blow b Use a voltmeter to check if 24 VAC is getting to the power connector on the circuit board If NO check your power supply If YES return the back box to the factory for repair a Check all connections to the ci
34. x months on all pan and tilts scanners or preset lenses used in continuous motion Service Department applications that is preset scan tour and auto scan modes Pelco 3500 Pelco Way Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco Clovis CA 93612 5699 shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are are not covered under this warranty instructed to return goods to the USA you may do one of the following Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from If the goods are to be sent by a COURIER SERVICE send the goods to the specific use or application made of the Products Pelco s liability for any claim whether Pelco based on breach of contract negligence infringement of any rights of any party or product 3500 Pelco Way iability relating to the Products shall not exceed the price paid by the Dealer to Pelco for Clovis CA 93612 5699 USA such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused If the goods are to be sent by a FREIGHT FORWARDER send the goods to whether by the negligence of Pelco or otherwise Pel