Home
Pelco SARIX C2951M-C User's Manual
Contents
1. c Press and hold the back focus button for three seconds to start the auto back focus mechanism C2951M C 12 09 Operation Once the camera is installed apply power to the camera The camera will start a configuration sequence The green LED flashes five times per second for approximately two minutes and then turns solid after the boot cycle is complete and the camera is on line IP ADDRESS SETTINGS If the camera is connected to a Dynamic Host Configuration Protocol DHCP network and DHCP is set to the On position the server will automatically assign an IP address to the device DHCP On is the default setting for the camera Set DHCP to the Off position to set the camera s IP address manually NOTES If the camera is not connected to a DHCP server but DHCP is set to On the default IP address 192 168 0 20 on subnet mask 255 255 255 0 is automatically assigned to the camera After the first camera is connected and assigned the default IP address the system will automatically look for other cameras on the auto IP address system and assign IP addresses in sequential order as required For example if three cameras are connected to a network without a DHCP server the first camera is assigned address 192 168 0 20 the second camera is assigned address 192 168 0 21 and the third camera is assigned address 192 168 0 22 Contact your network administrator to avoid network conflicts before setting changing the camera s IP ad
2. by Schneider Electric QUICK START IX and IXE Series Network Camera Sarix Technology C2951M C 12 09 Product Overview FRONT COVER OPENED Figure 1 Camera Connections and Features C2951M C 12 09 1 RJ 45 Network Port Connects the camera to the network Also supplies power to the camera through the network using Power over Ethernet PoE If PoE is not available the camera is prewired for 24 VAC camera Ethernet Link LED Glows solid amber to indicate that a live Accessory Port For use with compatible Pelco accessories system 000 Ethernet Activity LED Flashes green to indicate that data is being transmitted received by the connection is established 24 VAC Power Relay and Alarm Connections Supports 24 VAC as the power source one relay that can be used to control an external circuit and one alarm for physical input into the Reset Button Reboots the camera or restores the camera s factory default settings This button is recessed Use a small tool or a paper clip to press and release the reset button once to reboot the camera Press and hold the reset button for 10 seconds to restore the camera to the factory default settings foot and to focus the camera When a service cable is connected is disabled Mini SD Card Slot Saves a snapshot image to a mini SD card based on alarm activity Service Port Outputs analog video Use this port at the installation site to
3. Series h are available on the resource disc d tested to deliver optimal image quality to the IX Series and IXE Series megapixel cameras A standard definition lens installed on a megapixel camera will limit the resolution of the camera and crea 1 Install the lens a Remove the cover from the b Screw the lens onto the lens mount Be carefu e poor image quality ens mount to prevent dust from entering the space between the lens and the imager If necessary use clean compressed air to remove any foreign matter refer to the touch the camera imager when installed c Connect the auto iris lens to the 4 pin connector located on the s Figure 4 for the pin connec ions for the auto iris lens connector instructions shipped with the lens Make sure the lens does not ide of the camera Refer to Pin DC AID Auto Iris Lens 1 Control coil negative 2 Control coil positive 3 Drive coil positive 4 Drive coil negative Figure 2 Lens Pin Connections 2 Use a standard 1 4 20 screw to mount the camera in the desired location The maximum thread depth is 0 25 inches 6 4 mm The camera can be mounted from either the top or bottom depending on the type of camera mount used in your installation NOTE When installing inside an enclosure mount the camera in an inverted position to allow easy access to the service port Use the camera software to reconfigure the ca
4. port using Extensible Authentication Protocol EAP This port based authentication method prevents unauthorized access to a Local Area Network LAN through a physical port IMAGING TAB General Includes camera orientation and digital processing settings The orientation settings allow for standard or inverted installation of the camera The digital processing settings adjust the sharpness saturation and contrast of the scene Exposure Adjusts scene detail and contrast A scene with correct exposure settings has adequate detail and contrast between white and dark values An image with too little or too much exposure eliminates detail in the scene The camera features auto and manual exposure settings Focus Includes auto back focus and manual focus settings refer to Focus in the IX Series Installation Operation manual or the IXE Series Installation Operation manual for detailed instructions Focus sets the back focus to the center focal point of the scene Auto focus automatically back focuses the camera on the subject in the center of the scene Manual focus turns off the auto focus mechanism and locks the camera at a user specified position The manual focus setting is recommended only for indoor applications that have a single unchanging primary light source Tone Map Balances the brightest and darkest sections of an image to produce a picture with more balanced lighting and more detail White Balance Defines how the camera proce
5. set up the field of view o the camera video to the IP stream Power LED Glows solid amber and then flashes green during the configuration sequence glows solid green after the sequence is complete The LED can be di sabled through the user interface If this LED glows red solid or flashing contact Pelco Product Support at 1 800 289 9100 USA and Canada or 1 559 292 1981 International for assistance Auto Iris Lens Connector Controls the auto iris lens Insert auto iris lens into this connector he 4 pin connector from the DC drive Auto Back Focus Button Sets the auto back focus mechan ism Press the button once to center the auto back focus mechanism and to fully open the iris Press and hold the button for three seconds to start the auto back focus mechanism and focus the camera 12 NTSC PAL Button Toggles the service port between NTSC and PAL formats The default setting is NTSC NOTES Pelco recommends connecting the camera to a network that Protocol DHCP server to address devices Do not use a HUB in the network setup of the camera uses a Dynamic Host Configuration e To secure access to the IP camera place the camera behind a firewall when it is connected to a network C2951M C 12 09 Installation NOTES e For detailed instructions refer to the IX Series Instal Installation Operation manual Bo e Megapixel lenses are designed an ation Operation manual or the IXE
6. the date of Pelco shipment All goods requiring warranty repair shall be sent location Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products all not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential jamages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dea to state er with specific legal rights The Dealer may also have additional rights which are subject to variation from state a warranty repair is required the provide the following information Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and Model and serial number 2 Date of shipment P O number sal 3 Details of the defect or problem es order number or Pelco invoice number If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above please include a written explanation wi
7. 32 bit pixel color resolution Web Browser Internet Explorer 7 0 or later or Mozilla Firefox 3 0 or later NOTE Internet Explorer is not supported by Mac OS X 10 4 Media Player QuickTime 7 6 5 for Windows XP Windows Vista or QuickTime 7 6 4 for Mac OS X 10 4 NOTE This product is not compatible with QuickTime version 7 6 4 for Windows XP or Windows Vista If you have this version installed on your PC you will need to upgrade to QuickTime version 7 6 5 LOGGING ON TO THE CAMERA 1 Open the Web browser 2 Type the camera s IP address in the browser address bar NOTE If you do not know the camera s IP address you can locate it using the Pelco Device Utility software 3 Click the Login button in the navigation bar a dialog box appears 4 Type your user ID and password admin is the default for both NOTE If this is the first time you are logging on to the camera as the administrator the default User ID and Password are admin all lowercase For security purposes be sure to change the password after you log on for the first time 5 Click Log In C2951M C 12 09 7 LIVE PAGE ICONS Viewable icons are based on group permissions The camera has two predefined groups Public and Admin Public This defined group can be modified or deleted The default permissions for this group are single stream view stream selection and API access Admin This is the only defined group that cannot be deleted however the admini
8. an event source The camera supports alarm system and timer event sources Handlers Defines the actions that a camera takes when an event occurs The camera supports four event handlers Send Email Write JPEG to SD Card Upload JPEG to FTP Server and Open Close Relay Analytic Configuration Only available with the IXE Models Allows you to create several custom profiles that contain different camera settings With these profiles you can set up different scenarios for a behavior which will automatically detect and trigger alarms when specific activity is detected C2951M C 12 09 10 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five Two years Fiber optic products Unshielded Twisted Pair UTP transmission products CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models Three years Pelco designed Pelco branded fixed camer EH1500 Series enclosures Spectra IV pro DX Series digita Digital Sentry Series har Endura Series distribute PMCL200 300 400 Series years DF5 DF8 Series Legacy Series integrated Spectra III Spectra Mini Esprit Ti and T12500 Series ixed network cameras and network dome cameras with Sarix technology a models CCC1390H S
9. ctric www pelco com Pelco Inc Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120
10. d always be the most resource intensive of the streams Audio Configuration The Audio Configuration page allows you to setup the external audio device The default setting for Audio is disabled which means that no audio is transmitted from the camera When enabled audio is transmitted from the camera to the PC Based on your system configuration images and audio may not be synchronized NOTE Improper use of audio visual recording equipment may subject you to civil and criminal penalties Applicable laws regarding the use of such capabilities vary between jurisdictions and may require among other things express written consent from the recorded subjects You are solely responsible for insuring strict compliance with such laws and for strict adherence to any all rights of privacy and personalty USERS AND GROUPS TAB Users Defines the permissions assigned to individuals logged on to the camera Use this feature to create modify or delete user accounts Groups Defines the permissions assigned to users within a group Use this setting to create modify and delete groups and permissions Multiple permissions can be assigned to each group General Settings Changes the way the camera manages the users and groups settings These settings can be managed on a camera to camera basis or by using a centralized server to apply changes to multiple cameras EVENTS TAB Sources Defines the camera functions that are automatically triggered by
11. dress If you do not know the camera s IP address install the Pelco Device Utility software available on the resource disc shipped with the product The utility will locate the assigned name IP address and MAC address for devices connected to the same virtual local area network VLAN as your computer The Device Utility software is also available at www pelco com software downloads C2951M C 12 09 6 MINIMUM SYSTEM REQUIREMENTS IX SERIES Processor Intel Pentium 4 microprocessor 1 6 GHz Operating System Microsoft Windows XP Windows Vista or Mac OS X 10 4 or later Memory 512 MB RAM Network Interface Card 100 megabits or greater Monitor Minimum of 1024 x 768 resolution 16 or 32 bit pixel color resolution Web Browser Internet Explorer 7 0 or later or Mozilla Firefox 3 0 or later NOTE Internet Explorer is not supported by Mac OS X 10 4 Media Player QuickTime 7 6 5 for Windows XP Windows Vista or QuickTime 7 6 4 for Mac OS X 10 4 NOTE This product is not compatible with QuickTime version 7 6 4 for Windows XP or Windows Vista If you have this version installed on your PC you will need to upgrade to QuickTime version 7 6 5 IXE SERIES Processor Intel Core 2 Duo microprocessor 2 6 GHz Operating System Windows XP Windows Vista or Mac OS X 10 4 or later Memory 2 GB RAM Network Interface Card 100 megabits or greater Monitor Minimum of 1024 x 768 resolution 16 or
12. eries C1ODN Series C10CH Series and IP3701H Series ucts including Spectra IV IP Camclosure Series IS ICS IP integrated camera systems video recorders except DX9000 Series which is covered for a period of one year DVR5100 Series digital video recorders ware products DVX Series digital video recorders and NVR300 Series network video recorders network based video products Genex Series products multiplexers server and keyboard LCD monitors Standard varifocal fixed focal and motorized zoom lenses ixed dome products jositioning systems Spectra Mini IP Esprit ExSite and PS20 scanners including when used in continuous motion applications thermal imaging products Esprit and WW5700 Series window wiper excluding wiper blades CM6700 CM6800 CM9700 Series matrix Digital Light Processing DLP displays except lamp and color wheel The lamp and color wheel will be covered for a period of 90 days he air filter is not covered under warranty Intelli M elDC controllers PMCL542F PMCL547F ani year Video cassette recorders VCI Six months All pan and tilts scanners or preset Pelco will warrant all replacement parts an reight prepaid to a Pelco designate this warranty PMCL552F FHD monitors One Rs except video heads Video heads will be covered for a period of six months lenses used in continuous motion applications preset scan tour and auto scan modes repairs for 90 days from
13. ing on user permissions the Settings page allows you to manage camera system settings set up users and groups and control the camera To access the camera settings 1 Log on to the camera 2 Click the Settings link in the navigation bar located in the upper right corner of the page a list of menu tabs appear 3 Place the mouse pointer over a tab to display a list of submenus C2951M C 12 09 SYSTEM TAB General Settings Includes programmable fields for the device name time server and text overlay settings You can also use the General Settings page to turn the camera s power LED on or off and to configure the Simple Mail Transfer Protocol SMTP server to send an email notification when an event handler is activated System Information Includes read only fields for the firmware version hardware version model number and serial number of the system This information is typically required by Pelco Product Support for troubleshooting purposes NETWORK TAB General Displays the hardware address hostname DHCP settings and IP address settings SSL Secure Socket Layers encrypts communications making it difficult for unauthorized users to intercept and view user names and passwords SSH Secure Shell allows Pelco Product Support to log on to and service the camera for advanced troubleshooting purposes 802 1x Authenticates devices that want to establish a point to point access through a wired or wireless
14. mera orientation for normal operation C2951M C 12 09 3 Connect the network cable to the RJ 45 network port located at the back of the camera refer to Figure 3 NOTE If the network has no Power over Ethernet PoE connect a 24 VAC Class 2 power supply to the 24 VAC power connector refer to Figure 4 se RE Figure 3 Pin Descriptions Pin Function TX TX RX PoE 1 2 PoE 1 2 RX PoE 3 4 oN OD Aa BI w r PoE 3 4 4 For Class B installations attach the supplied ferrite to the network cable The ferrite should be installed on the cable approximately one inch from the camera s RJ 45 networl port J WARNING The ferrite must be installed for the camera to meet FCC Class B compliance standards Failure to correctly install the ferrite might cause harmful interference to radio communications 5 Connect the necessary wiring for alarms and relays refer to Figure 4 Only use the 24 VAC wires if PoE is not available Figure 4 Alarm and Relay Wiring 6 Apply power to the camera 7 View the camera image using the service port or a Web browser 8 Focus the lens a Press the auto back focus button once to center the focus mechanism The button is located on the side of the camera b Manually adjust the zoom and focus of the lens to the desired field of view refer to the instructions shipped with the lens
15. sses video images to render true colors in a scene White balance is especially effective in scenes with changing lighting conditions or in scenes with more than one type of light source Window Blanking Conceals user defined privacy areas A blanked area appears on the screen as a solid gray window The camera can handle up to four blanked windows as long as the total blanked area does not exceed 50 percent of the field of view C2951M C 12 09 9 A V STREAMS TAB Use the A V Streams tab to configure the video and audio streams for the camera The A V Streams tab includes a Video Presets page a Video Configuration page and an Audio Configuration page Video Presets The Video Preset page includes three fully configured video presets which include primary and secondary video stream settings for easy setup These presets may also be used as a starting point for a custom video configuration These preset configurations vary depending on camera model Video Configuration The Video Configuration page allows you to customize the compression resolution image rate and bit rate of the video streams The default names for the streams are Primary Stream and Secondary Stream Although each stream can be configured independently the settings of one stream can limit the options available to the other stream depending on the processing power used NOTE Always configure the primary stream before the secondary stream The primary stream shoul
16. strator password can be changed For security purposes it is important that you change your password after you log on to the device for the first time This group has access to all permissions oO iM oe Bo Lo Ls ol Show Device List Displays a list of viewable cameras connected to the same virtual local area network VLAN as the camera to which you are logged on Disable Viewer Closes the live view window 1x 1 Mode Displays a single video pane 2 x 2 Mode Displays 4 video panes in rows of two 3 x 3 Mode Displays 9 video panes in rows of three 4x 4 Mode Displays 16 video panes in rows of four Select Stream Selects the viewable video stream primary or secondary and selects unicast or multicast settings Maximize Viewing Area Scales the image to the full size of the browser Show Toolbar Returns the window to normal view This icon is only available after the window has been set to maximize viewing area Open Stream in New Window Opens the video in a scalable independent window Opening the video in a separate window allows you to view the video while other applications are running This window can be minimized maximized or closed using the title bar buttons of the active window The window can also be resized to your specifications by dragging the lower right corner of the window Take a Snapshot Captures the image displayed in the video pane and saves it as a JPEG file SETTINGS PAGE Depend
17. th the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS To expedite parts returned for repair or credit please call Pelco at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair and designated return location All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid eo REVISION HISTORY Manual Date Comments C2951M 1 09 Original version C2951M A 2 09 Revised installation instructions 2951M B 9 09 Revised manual to reflect Sarix 1 3 software additions changes 2951M C 12 09 Revised manual to reflect Sarix 1 4 software additions changes Pelco the Pelco logo Camclosure Digital Sentry Endura Esprit ExSite Genex Intelli M Legacy and Spectra are registered trademarks of Pelco Inc Spectra Ill and Sarix are trademarks of Pelco Inc All product names and services identified throughout this document are trademarks or registered trademarks of their respective companies The absence of a trademark or registered trademark from this document does not constitute a waiver of intellectual property rights Copyright 2009 Pelco Inc All rights reserved PELLO by Schneider Ele