Home

Pelco Switch MS504AFL User's Manual

image

Contents

1. MS500 Series Switchers Looping Configuration with MS500 Series Switchers with Audio Follow MS500 Series Switchers with Balanced Audio Follow Schematic for 4 18 Position Manual Switchers see 9 Schematic for 40 Position Manual swithcers 9 M NONA LIST OF TABLES Table Page A Video Coaxial Cable Requirements iiris 5 Pelco Manual C820M D 1 01 IMPORTANT SAFEGUARDS AND WARNINGS Pelco Manual C820M D 1 01 Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by qualified service personnel and conform to all local codes 2 Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 3 Only use replacement parts recommended by Pelco 4 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry The product and or manual may bear the following marks A AN This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK This symbol indicates that there are DO NOT OPEN important operating and ma
2. RED 100 NOTES AS REQUIRED ivi FOR LOOPING DELETE RESISTORS 75 OHM FOR 110 VAC INPUT JUMPER 1 amp 332 amp 4 FOR 220 VAC INPUT JUMPER 2 amp 3 AC INPUT Figure 8 Schematic for 40 Position Manual swithcers Pelco Manual C820M D 1 01 SPECIFICATIONS VIDEO Inputs 4 8 12 or 40 as indicated by the last two digits of the model number Video Connectors BNC Audio Connectors AF Switchers 1 8 inch RCA phone jack BAF Switchers Terminal block Termination Terminated or Non looping Switchers Input 75 ohm internal termination Output 75 ohm source termination Looping Switchers Input High impedance looping Output High impedance looping ELECTRICAL Models MS500G MS500GL MS540DT and MS540LDT Input Voltage 120 VAC 50 60 Hz or 230 VAC 50 Hz Power Requirement 095 amp 11 vA Fuse 3 AG 1 16 amp slo blow Power Cord 3 wire grounded 18 AWG Models MS540DT and MS540LDT Only Output Amplifier One amplified output and one non amplified output for use with MPT9000CZ MPT9000PZ Coaxitron System Gain Unity Frequency Response Flat within 1 dB to 10 MHz Max Signal Level 2 Vp p Pelco Manual C820M D 1 01 Pelco Manual C820M D 1 01 GENERAL Switching Construction Cover Chassis Panel Environment Dimensions MS504 Series except AFL BAF and BAF models MS504AFL MS504BAF MS504BAFL and MS508 Series except AFL model MS508AFL MS512 Series MS518 Series and MS5
3. Refer to Figures 1 and 2 TERMINATE TERMINATE MONITOR COAXITRON SWITCH IN THE TRANSMITTER 75Q POSITION TERMINATE LOOPING OUTPUT AT 75 AC INPUT MSS504AF REAR VIEW Figure 2 MS500 Series Switchers Terminating Configuration with Coaxitron Transmitter Pelco Manual C820M D 1 01 LOOPING SWITCHERS IMPORTANT Looping Use coaxial cable to connect the input and looping video cables to the appropriate input switchers do not have inter connectors Connect the monitor s to the monitor output Refer to Figures 3 and 4 nal termination Inputs must be terminated at 75 ohms by other equipment in the system UN TERMINATED TERMINATE MONITOR MONITOR SWITCH IN THE SWITCH IN THE HI Z POSITION 75Q POSITION MON e AC INPUT MS504LDT REAR VIEW 098 56 Q e 9 AC INPUT MS504DT REAR VIEW TERMINATE COAXITRON TRANSMITTER UNTERMINATED TRANSMITTER MS504LDT REAR VIEW TERMINATE MONITOR COAXITRON SWITCH IN THE TRANSMITTER 752 POSITION TERMINATE LOOPING MS504DT OUTPUT AT 75Q REAR VIEW Figure 4 MS500 Series Switchers Looping Configuration with Coaxitron Transmitter 6 Pelco Manual C820M D 1 01 SWITCHERS WITH AUDIO FOLLOW NOTE Configuration does MS500 Series models with AF in the suffix have a connection
4. for an audio signal source not permit two way commu Using appropriate cable with compatible connectors connect audio signal sources to RCA nication Microphones or jack refer to Figure 5 speakers etc can be in stalled at the camera site TERMINATE MONITOR SWITCH IN THE AUDIO IN OUT 75Q POSITION 4 3 1 DE 0900 MS504AF REAR VIEW Figure 5 MS500 Series Switchers with Audio Follow SWITCHERS WITH BALANCED AUDIO FOLLOW NOTE Configuration does MS500 Series models with BAF in the suffix have terminal block connections for a two not permit two way commu conductor cable This cable can be used for balanced audio follow or similar signals Refer nication Microphones or to Figure 6 Speakers etc can be in stalled at the camera site TERMINATE MONITOR SWITCH IN THE 75Q POSITION MS504BAF REAR VIEW Figure 6 MS500 Series Switchers with Balanced Audio Follow Pelco Manual C820M D 1 01 7 SWITCHERS WITH AMPLIFIED OUTPUT The MS540DT and MS540LDT switchers provide both an amplified output Monitor 1 and a non amplified output Monitor 2 Most installations require the use of Monitor 2 output for proper operations NOTE Use Monitor 2 non amplitied output only when interfacing with the MPT92000CZ MPT9000FZ or KBD9000 KBD9000 X Coaxitron controls OPERATION To operate the MS500 Series Switcher plug in the power cord and press a camera button
5. 220 Same as MS504GLDT except 230 VAC MS508GLDT Same as MS504GLDT 8 inputs UL MS512GLDT Same as MS504GLDT 12 inputs UL MS512GLDT 220 Same as MS512GLDT except 230 VAC MS518GLDT Same as MS504GLDT 18 inputs UL Looping With Audio Follow MS504AFL 4 inputs UL MS508AFL 8 inputs UL MS512AFL 12 inputs UL MS518AFL 18 inputs UL Looping With Balanced Audio Follow MS504BAFL 4 inputs UL MS508BAFL 8 inputs UL MS512BAFL 12 input UL INSTALLATION Pelco Manual C820M D 1 01 INSTALLATION NOTE For the maximum recommended cable dis tances refer to the installa tion manuals supplied with equipment camera lens and monitor to be used with the switcher 1 Place the unit on a flat surface or install it in an equipment rack using the appropriate rack mount kit 2 Refer to Figures 1 6 and select the desired configuration for your installation Make all equipment connections as illustrated in the drawings Refer to Table A for the type of coaxial cable to use 3 Plug in the power cord The switcher will begin operating Table A Video Coaxial Cable Requirements RG59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Minimum cable requirements 75 ohms impedance All copper center conductor All copper braided shield with 95 braid coverage TERMINATING SWITCHERS When using non looping switchers the monitor should be terminated unless the looping output if available on the monitor is used
6. 40DT except MS518AFL and MS540LDT MS518AFL and MS540LDT Interlocked manual pushbuttons Steel black polyester powder coat Steel zinc plated Aluminum black polyester powder coat 32 to 120 F 0 to 48 89 C 1 75 H x 5 3 W x 9 3 L inches 4 45 cm x 13 46 cm x 23 62 cm 1 75 H x 14 3 W x 9 3 L inches 4 45 cm x 36 32 cm x 23 62 cm 1 75 H x 17 12 W x 9 3 L inches 4 45 cm x 43 48 cm x 23 62 cm 3 50 H x 17 12 W x 9 3 L inches 8 89 cm x 43 48 cm x 23 62 cm Design and product specifications subject to change without notice 11 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applicati
7. MS500 Series Manual Switchers Installation Operation Manual C820M D 1 01 Pelco 3500 Pelco Way Clovis e CA 93612 5699 USA lt www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ee e 3 DESGRIPTION s2scc3 tecti eere ioc fee eene wed peste duane ede Nevin eee olen 4 MODELS e 4 INSTALLATION TERMINATING SWITCHERS LOOPING SWITCHERS x erstes ussestee to ioi etc Mie Pese Pe iP a Erde e eese Goaxitrori TEADSIIHOT oot irai tad ee Fecit sace ete a terae sa dieran tt loda cea das a 6 SWITCHERS WITH AUDIO FOLLOW ui SWITCHERS WITH BALANCED AUDIO FOLLOW id SWITCHERS WITH AMPLIFIED OUTPUT 8 OPERATION eerie icit an Sensis bes ettari iecit ied wast aa 8 MAINTENANCE ca ee 8 SPECIFICATIONS eire ates redes thse sect ender eet Hee ete rte eeten eet deen tte nates bel andes 10 WARRANTY AND RETURN INFORMA ION ss assnssiessnnsieinerenrinrrnnrinrinninninnrrninrinrsnnrenne 12 LIST OF ILLUSTRATIONS Figure Page MS500 Series Switchers Terminating Configuration sese ee eee eee eee eee 5 MS500 Series Switchers Terminating Configuration with Coaxitron t MS500 Series Switchers Looping Configuration
8. e Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state REVISION HISTORY Manual C820M C820M A C820M B C820M C C820M D Date 3 88 9 90 6 92 10 97 1 01 Comments Original version Added to Warning Section for UL compliance Revised Figures 1 and 2 Put into new format If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be
9. intenance instructions in the literature accompanying this unit Please thoroughly familiarize yourself with the information in this manual prior to installation and operation DESCRIPTION The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel The MS500 Series Switchers are designed for either looping or terminating operation depending on the model MODELS Terminating MS504DT 4 inputs UL MS508DT 8 inputs UL MS512DT 12 inputs UL MS518DT 18 inputs UL MS540DT 40 inputs UL MS504GDT 4 inputs illuminated buttons 120 VAC UL MS508GDT Same as MS504GDT 8 inputs UL MS512GDT Same as MS504GDT 12 inputs UL MS512GDT 220 Same as MS512GDT except 230 VAC MS518GDT Same as MS504GDT 18 inputs UL Terminating With Audio Follow MS504AF 4 inputs UL MS508AF 8 inputs UL MS512AF 12 inputs UL MS518AF 18 inputs UL Terminating With Balanced Audio Follow MS504BAF 4 inputs UL MS508BAF 8 inputs UL MS512BAF 12 inputs UL Looping MS504LDT 4 inputs UL MS508LDT 8 inputs UL MS512LDT 12 inputs UL MS518LDT 18 inputs UL MS540LDT 40 inputs 2 monitor outputs 120 VAC UL MS540LDT 220 Same as MS540LDT except 230 VAC MS504GLDT 4 inputs illuminated buttons 120 VAC input UL MS504GLDT
10. ons Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides th
11. prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Revised to cover all MS500 Series models Added DT200 to Options section Added illustrations for terminated and looping configurations with a Coaxitron transmitter Updated manual to new format Pelco the Pelco logo Spectra Genex Legacy Coaxitron and PelcoVision are registered trademarks of Pelco Esprit and Camclosure are trademarks of Pelco Copyright 2001 Pelco All rights reserved 12 Pelco Manual C820M D 1 01
12. to view video from the corresponding camera MAINTENANCE Regularly scheduled maintenance is not required However maintenance may be required in the following situations 1 For switcher contacts that are not conducting properly clean with a non conducting electrical contact spray cleaner especially made for that purpose Remove cover for access to the contacts and spray cleaner carefully into contacts from the rear 2 To replace burned out bulbs in illuminated models remove the switch cover from the front of the unit and push the bulb upwards then lift out Replace with Pelco LAP327 IMPORTANT Units plugged into electrical outlets should be unplugged before spraying contacts Pelco Manual C820M D 1 01 CON 3505 f NES AUDIO JAX o INPUTS l U U l AUDIO OUTPUT l U Ti 7 R RED BLK YEL GILT wel whe osama dle oboe C BLK GRN YEL j 1 TYPICAL 1 CONNECTION FOR LOOPING 1 1 FOR 220 VAC INPUT ADD JUMPER TO 2 amp 3 REMOVE JUMPER FROM 1 amp 3 2 amp 4 I I y GRY i zu BLK RED BRN I I I I I VIDEO OUTPUT VIDEO INPUTS DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING TYPICAL CONNECTION FOR LOOPING MON 2 VIDEO OUTPUT Ti L O YEL 562W IN4005 O GRN YEI GRN BLK IN 4740 RED BLU BLK YEL GRY BLK GRN IN 4005 BRN MONI AMPLIFIED VIDEO OUPUT BLK

Download Pdf Manuals

image

Related Search

Related Contents

  ECメーター  MANUEL D`INSTRUCTIONS MANUEL D`INSTALLATION  TANDBERG MSE 8321 User's Manual  Samsung Galaxy Tab 4 (10.1", 4G) Bruksanvisning(LL)  Leica TCRA1103 Settings SURV-GEN  IPMATE1500RD取扱説明書  