Home
Pelco Switch FR8304 User's Manual
Contents
1. FT8304 FR8304 TRANSMITTER RECEIVER Figure 4 Rear Panel of FT8304 Transmitter and FR8304 Receiver RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STAND ALONE POWER CONNECTOR 2 pin connector for power connection of stand alone module removable mating connector with screw terminals not shown FIBER OPTIC CONNECTOR ST or FC dependent on FT8304 FR8304 model VIDEO IN CONNECTORS 1 4 75 ohm BNC analog video input transmitter only VIDEO OUT CONNECTORS 1 4 75 ohm BNC analog video output receiver only ooo For additional information about rear panel connections refer to the nstallation section C1644M B 6 06 11 Installation PACKAGE CONTENTS The following items are supplied 1 FT8304 transmitter or FR8304 receiver 1 Regulated switching power supply with four plug adapters North American Australian U K and European configurations 100 240 VAC 50 60 Hz input 12 VDC output 1 Wall clip with two 4 40 x 0 250 inch Phillips pan head screws with lock washers for attachment of single module to wall 1 FT8304 FR8304 Fiber Transmitter and Receiver Installation manual this manual MOUNTING The FT8304 transmitter FR8304 receiver can be mounted into a rack or can be used as a stand alone module As a stand alone module the unit can be placed on a desktop or can be mounted to a wall MOUNTING THE TRANSMITTER RECEIVER INTO A R
2. Incoming video signal is not present on the channel Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Check BNC connections Coaxial cable is defective Replace cable Continued on next page C1644M B 6 06 Table A Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Video P resent LED Continued Red on receiver Incoming video signal is not present on the channel Optical signal is not being received from the trans mitter Optic Fault LED is also red Refer to the Optic Fault LED Receiver section in this table Video source is no powered on Check power connection to the video source Video source is no connected to the transmitter Coaxial cable connected to Optic Fault LED Transmitter the transmitter is defective Check BNC connections Replace cable Green Laser is operating 0 action required properly Flashing red Laser has shut down Transmitter is operating in Ensure that transmitter oper extreme environmental conditions for example operating temperature is below or above recom mended range as stated in the Specifications section ates according to operating conditions stated in the Specifications section and then cycle the power If problem persists contact
3. Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Use only installation methods and materials capable of supporting four times the maximum specified load A CCC approved power cord must be used to power this equipment when used in China CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so C1644M B 6 06 The product and or manual may bear the following marks A This symbol indicates that dangerous voltage
4. constituting a risk of electric shock is present CAUTION oa RISK OF ELECTRIC SHOCK A This symbol indicates that there are important DO NOT OPEN operating and maintenance instructions in the literature accompanying this unit C1644M B 6 06 5 Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital a
5. 4 Rear Panel of FT8304 Transmitter and FR8304 Receiver 11 5 Mounting the FT8304 Transmitter FR8304 Receiver Using the Wall Clip 14 6 FT8304 Transmitter FR8304 Receiver Connections 15 List of Tables A Troubleshooting with Front Panel Indicators 16 C1644M B 6 06 3 Important Safety Instructions So m iB cce Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions 0 not install near any heat sources such as radiators heat registers stoves or other pparatus including amplifiers that produce heat CJ Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the 0 P bsolete outlet otect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer
6. Product Support Laser has reached end of life Cycle the power If problem persists contact Product Support C1644M B 6 06 Continued on next page Table A Troubleshooting with Front Panel Indicators Continued Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED Receiver Green The optical signal is No action required being received from the transmitter Red The optical signal is Transmitter is not powered Check power connections not being received Replace power supply if from the transmitter necessary Fiber optic cable is not Check fiber optic connected connections Fiber optic cable connectors Clean polish or replace fiber are dirty or are damaged optic cable connectors as necessary Fiber optic cable is Replace cable defective Optical dB losses in the Check for problems with iber optic installation the fiber optic installation exceed the optical power for example excessive dB budget specification stated losses in connectors splices in the Specifications patch panels cables section and so on Optical dB losses in the Contact Product Support iber optic installation meet he optical power budget specification stated in the Specifications section however the receiver may be defective 18 C1644M B 6 06 Specifications VIDEO Number of Channels Modulation Type Video Input F
7. Three years on PMCL200 300 400 Series LCD monitors Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use
8. 3U Blank filler panel single width RK5002B 3U Blank filler panel double width RK5001 1UEXP Adapter kit that allows a 3 RU single width fiber module to be used in RK5000PS 5U rack mount chassis 8 C1644M B 6 06 FRONT PANEL The front panel of the FT8304 transmitter and the FR8304 receiver provides LED indicators that allow you to monitor signal status laser status transmitter only and operating power The following sections provide a view of the front panel of the FT8304 transmitter and the FR8304 receiver FRONT PANEL FT8304 TRANSMITTER Figure 2 illustrates the front panel of the FT8304 transmitter FT8304 TRANSMITTER Figure 2 Front Panel of FT8304 Transmitter VIDEO PRESENT LEDs 1 4 OPTIC FAULT LED laser status indicator POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section C1644M B 6 06 9 FRONT PANEL FR8304 RECEIVER Figure 3 illustrates the front panel of the FR8304 receiver FR8304 RECEIVER Figure 3 Front Panel of FR8304 Receiver VIDEO PRESENT LEDs 1 4 OPTIC FAULT LED optical signal status indicator 3 POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section 10 C1644M B 6 06 REAR PANEL All connections to the FT8304 transmitter and the FR8304 receiver are made to the rear panel of the modules refer to Figure 4
9. 6 Pelco DLP is a registered trademark of Texas Instruments Inc All rights reserved PELLI Worldwide Headquarters 3500 Pelco Way Clovis California 933612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
10. ACK The FT8304 transmitter FR8304 receiver can be installed into an RK5000 Series rack mount chassis which can be mounted into an industry standard 19 inch 48 26 cm equipment rack The RK5000 Series rack mount chassis includes the following models e RK5000PS 3U and RK5000 3U Designed to accommodate fiber optic modules as follows The RK500 power supp RK500 yisn OPS 3U rack y ot included mount chassis provides 12 single width module slots and a 0 3U rack mount chassis provides 14 single width module slots a power Power to the modules can be supplied using the optional external power supply EPS5000 120 For additional in Installation e RK5000PS 5U optic modu required fo chassis For informa les w Installation ormation re manual Designed to ith the use o tion about the RK5 manual er to the RK5000PS 3U RK5000 3U Fiber Rack Mount Chassis accommodate Endura modules but can also accommodate fiber the appropriate adapter kit The RK5001 1UEXP adapter kit is installation of the FT8304 transmitter FR8304 receiver into the 5000 5 50 000PS 5U chassis refer to the RKS5000PS 5U Rack Mount Chassis C1644M B 6 06 MOUNTING THE TRANSMITTER RECEIVER TO A WALL The FT8304 transmitter FR8304 receiver can be mounted to a wall in the following ways e Using the supplied wall clip for attachment of a single module to a wall For installa
11. INSTALLATION FT8304 FR8304 Fiber Transmitter and Receiver Four Channel Digitally Encoded Video C1644M B 6 06 Contents Important Safety 581 4 Regulatory 01 85 er ck REI EIE RR v3 eR caus CR ETENEE 6 Product OVENI We cepto PRI PELA Peg Risk esee ERE RI Ed Yeu i 7 Description 2 2 II e 7 Jp PEE 8 Optional Accessories 8 Front Panel i c rero PPP PES SRM IP yee 9 Front Panel FT8304 Transmitter 9 Front Panel FR8304 10 Rear Panels Im RERO S peed enantio 11 JriStall ENON a ee erent taste na t 12 Package Contents X rhe 12 sd ein aes TR 12 Mounting the Transmitter Receiver into 12 Mounting the Transmitter Receiver to a Wall 13 En ui En 15 Troubleshooting m ee 16 SPSCIIGATIONS ic oem RR Rd Med 19 List of Illustrations 1 Four Channel Video FT8304 Transmitter and FR8304 Receiver 7 2 Front Panel of FT8304 9 3 Front Panel of FR8304 Receiver 10
12. T8304 Video Output FR8304 Bandwidth Gain Crosstalk Differential Gain Differential Phase Tilt Signal to Noise Ratio GENERAL Operating Temperature Input Power Requirements LED Indicators Dimensions Unit Weight MECHANICAL Connectors Video Rack Power Alarm Stand Alone Power Fiber Optic C1644M B 6 06 4 Pulse code modulation 8 bit resolution 1 0 Vp p 75 ohms NTSC PAL and SECAM 6 5 MHz Unity 50 dB typical at 3 58 MHz 196 12 196 60 dB CCIR weighted 40 to 167 F 40 to 75 C 12 VDC or 24 VAC 280 mA Video Present per channel Optic Fault Power 8 75 Dx 1 08 W x 481 H 22 23 x 2 74 x 12 22 cm 1 46 Ib 0 66 kg BNC per channel 4 pin connector 2 pin connector screw terminal ST for multimode fiber ST or FC for single mode fiber OPTICAL POWER BUDGET TRANSMISSION DISTANCE AND LASER CLASS 1 LIMIT Model No Optical Maximum Laser Compatible Power Transmission Class1 Transmitter Receiver Wavelength Budget Distance Limit Multimode 62 5 125 um FT8304MSTR FR8304MSTR 1310 nm 20 dB 2 km 1 2 15 6 mW Single Mode 9 125 pm FT8304SSTR FR8304SSTR 1310 nm 20 dB 30 km 18 6 15 6 mW FT8304SFCR FR8304SFCR 1310 nm 20 dB 30 km 18 6 15 6 mW The FT8304 transmitter and the FR8304 receiver are classified by the FDA as Class 1 laser products When using 50 125 um multimode fiber subtract 3 dB fr
13. number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C1644M 9 04 Original version C1644M A 11 04 Updated Specifications section and Figure 5 C1644M B 6 06 Added conformal coating and Optic Fault LED laser status information 06 13948 Updated optional accessories mounting instructions power supply recommendations and specifications Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Copyright 200
14. of FT8304 transmitter FR8304 receiver connections POWER ALARM CONNECTION FOR RACK MOUNTED MODULE POWER CONNECTION FOR STAND ALONE MODULE FIBER OPTIC CABLE COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE Figure 6 FT8304 Transmitter FR8304 Receiver Connections C1644M B 6 06 Troubleshooting LED indicators on the front panel of the FT8304 transmitter FR8304 receiver refer to Figure 2 and to Figure 3 respectively allow you to monitor signal status laser status transmitter only and operating power Table A provides information about the front panel indicators and associated troubleshooting guidelines Table A Troubleshooting with Front Panel Indicators Indicator Color Possible Cause Corrective Action Blue Pelco logo lights Power LED Pelco badge Power is being applied to the module No action required Blue Pelco logo does not light Power is not being applied to the module Power connection is faulty Check power connection If module is rack mounted reseat module or power supply as necessary Power supply has failed Replace power supply Loss of power occurs due to tripped circuit breakers blown fuses or faulty electrical service Video Present LED Check circuit breakers fuses or electrical service as necessary Green Incoming video signal is present on the channel No action required Red on transmitter
15. om the optical power budget Maximum transmission distance is limited by fiber bandwidth Maximum transmission distance is based on attenuation of 0 5 dB km plus a 5 dB buffer for connector and splice losses NOTES e For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT8304MSTR for example is CT8304MSTR e For models with higher optical power budgets contact the factory 20 C1644M B 6 06 comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling K This equipment contains electrical or electronic components that must be recycled properly to mmmmm this equipment C1644M B 6 06 21 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FR FT FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty
16. or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization
17. or monitoring of signal status laser status and operating power The FT8304 transmitter FR8304 receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825 1 Edition 1 2 2001 08 C1644M B 6 06 MODELS The FT8304 FR8304 fiber transmitter and receiver consist of the following series of models Multimode Models FT8304MSTR Four channel fiber optic video transmitter multimode ST connector FR8304MSTR Four channel fiber optic video receiver multimode ST connector Single Mode Models FT8304SSTR Four channel fiber optic video transmitter single mode ST connector FR8304SSTR Four channel fiber optic video receiver single mode ST connector FT8304SFCR Four channel fiber optic video transmitter single mode FC connector FR8304SFCR Four channel fiber optic video receiver single mode FC connector For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT8304MSTR for example is CT8304MSTR OPTIONAL ACCESSORIES The following optional accessories are available WM 5001 3U Wall mount base kit for single width module WM5001 3UEXP Wall mount expansion kit for single width module RK5000 3U 19 inch rack mount chassis for 14 slots no power 3 RUs RK5000PS 3U 19 inch rack mount chassis for 12 slots with power 3 RUs EPS5000 120 External rack power supply 1 RU dual 120 W power outputs RK5001B
18. pparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada C1644M B 6 06 Product Overview DESCRIPTION The FT8304 FR8304 fiber transmitter and receiver provide the ability to transmit up to four composite video channels over one optical fiber refer to Figure 1 FOUR FOUR VIDEO VIDEO INPUTS OUTPUTS 8304 FR8304 P TRANSMITTER ONE RECEIVER FIBER Figure 1 Four Channel Video FT8304 Transmitter and FR8304 Receiver Features of the FT8304 FR8304 fiber optic transmission system include the following 8 bit digitally encoded video for high quality multichannel video transmission over a single fiber Multimode fiber support for distances up to 2 km 1 2 mi Single mode fiber support for distances up to 30 km 18 6 mi Exceeds all requirements for the RS 250C Medium Haul Transmission specification 12 VDC or 24 VAC power supply Compatible with NTSC PAL and SECAM video standards Meets NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature mechanical shock and vibration humidity with condensation high line low line voltage conditions and transient voltage protection NOTE Conformal coating is required for operation in environments with relative humidity above 95 condensing No performance adjustments required Stand alone and rack mountable modular design LED indicators f
19. sing two screws not provided 2 Slide the module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip 3 Attach the module to the clip using the two Phillips pan head screws provided for the clip C1644M B 6 06 13 lt FLANGE Qa veRTICAL MOUNTING HOLE 2 S HORIZONTAL MOUNTING HOLE 2 TRANSMITTER RECEIVER LOWER SCREW PHILLIPS WALL CLIP FLANGE PAN HEAD WITH LOCK WASHER 2 Figure 5 Mounting the FT8304 Transmitter FR8304 Receiver Using the Wall Clip C1644M B 6 06 CONNECTIONS Connections to the FT8304 transmitter and the FR8304 receiver are made on the rear panel of the modules and consist of the following e Power connection NOTES A12 VDC or 24 VAC power supply can be used to power the transmitter receiver when used as a stand alon supply is used the p Class 2 and rated as In extreme tempera power supply such a e Fiber connection e Video input connections e X Video output connections Figure 6 provides an illustration ure condi e module A 12 VDC power supply is provided If a 24 VAC power ower supply must be a Listed Direct Plug In Power Unit marked as 24 VAC 300 mA minimum output ions it is recommended that an industrial rated outdoor s the Pelco WCS1 4 power supply be used ansmitte only receiver only
20. tion instructions refer to the Mounting the Transmitter Receiver Using the Wall Clip section e Using the optional WM5001 wall mount kits which are designed for mounting of single width fiber optic modules The WM5001 3U base kit allows mounting of a single module to a wall The WM5001 3UEXP expansion kit allows mounting of an additional module It is recommended that a maximum of three expansion kits be used with the base kit allowing a maximum of four single width modules to be attached to a wall NOTE The WM5001 wall mount kits can be used with the WM5002 wall mount kits which are designed for mounting of double width fiber optic modules If mounting a mix of single width and double width modules is desired it is recommended that a maximum of two single width modules and one double width module be mounted in combination with one another For mounting instructions using the wall mount kits refer to the WM5000 Series Wall Mount Kit Installation manual Mounting the Transmitter Receiver Using the Wall Clip NOTE Before mounting the FT8304 transmitter FR8304 receiver to a wall ensure that there is adequate space at both ends for viewing the front panel LEDs and for making the various rear panel cable connections To attach the FT8304 transmitter FR8304 receiver to a wall using the supplied wall clip refer to Figure 5 and do the following 1 Using the two vertical or horizontal wall mounting holes attach the wall clip to a wall u
Download Pdf Manuals
Related Search
Related Contents
Equip Cat.6 Unshielded Keystone Jack Toolfree 取扱説明書 - Plexmotion(プレクスモーション) TCI KRF EMC Power Filters User`s Manual フェイス機能とは? 取扱説明書 / Instruction Manual Movotrak T90 and T130 Info SEP-OCT - CGSP-Défense Le site francophone du plus grand Printemps 2008 - Banque du Canada 取扱説明書 - 三菱電機 Copyright © All rights reserved.