1. ssssss 8 6 Installing the MRD Board onto the EH3512 Adapter 8 7 EH2512 Series Enclosure Installation 19 8 Control Power and Camera Connections ccccccccsseccssescesseeeessseecessaeesenes 10 9 Multiple Units with Parallel Connections ssssssseeenen 10 10 Data Cable Wiring EEEE 10 LIST OF TABLES Table A Baud Rate Switch Settings isiin siniaki iaiia h inne oan bande eed B MRD DIP Switch Settings C Two Wire Control Connections Pelco Manual C1973M B 8 03 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by qualified service personnel and con form to all local codes 2 There are no user serviceable parts inside this unit Only authorized service personnel may open the unit 3 To reduce the risk of fire or electric shock do not expose this unit to rain or moisture if this unit is designed for indoor use only The product and or manual may bear the following marks This symbol indicates that dangerous volt A N age constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK This symbol indicates that there are impor DO NOT OPEN N tant operating and maintenance instructions in the literature accompanying this unit Please thoroughly familiarize yourself with the informatio
2. MRD1400HZ16 Camera Control Interface for the CC1400HZ16 Installation Operation Manual C1973M B 8 03 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com In North America and Canada Tel 800 289 9100 FAX 800 289 9150 International Customers Tel 1 559 292 1981 e FAX 1 559 348 1120 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS senem 3 DESCRIPTION em ak 4 INSTALLATION m eee ast 4 DIPSWITCH SETTINGS cierta t Rose Poe te Meise lei eer ei cd 4 BAUD RATE SELECTION 4 MBD ADDRESS SETTINGS 2 tris ti eR te iei eve cyber euge c 5 MRD1400HZ16 INSTALLATION METHODS seen eene 6 WALL MOUNTING 2 e ence 4 6 DF5 DF8 SERIES DOME INSTALLATION 6 EH3512 SERIES ENCLOSURE INSTALLATION 8 EH2512 SERIES ENCLOSURE INSTALLATION 29 CONTROL POWER AND CAMERA CONNECTIONS see 10 OPERATION m cece 11 TROUBLESHOOTING sesh C 12 WARRANTY AND RETURN INFORMATION esee eene nennen 12 LIST OF ILLUSTRATONS Figure Page 1 SW 1 Default Switch Settings sssssssssssseeeenneee nnns 4 2 Wall MOUMMUING EH EE 6 3 DF5 DF8 Installation T4 4 Removing the MRD Board aoe eal 5 Installing the EH3512 Adapter
3. are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA numbe
4. feet 3 Make required power connections Refer to Figure 8 Note nput power range 12 24 volts AC DC I T x CONNECT Table C Two Wire Control Connections From Controller MRD TX R TX R MRD1400HZ16 Made n USA 01219 Figure 8 Control Power and Camera Connections CC1400HZ16 CC1400HZ16 FROM THE CONTROLLER Figure 9 Multiple Units with Parallel Connections ONE TWIST IN CABLE PIN P 1 8 2 PA 6 I 3 b LOCKING TAB ON BOTTOM Figure 10 Data Cable Wiring 01221 10 Pelco Manual C1973M B 8 03 OPERATION CAMERA OPERATION PELCO CONTROLLER COMMAND Zoom In Tilt joystick up Zoom Out Tilt joystick down Quickly Zoom In Press the Zoom Tele button or turn the joystick clockwise Quickly Zoom Out Press the Zoom Wide button or turn the joystick counterclockwise Focus Near Press the Focus Near button Focus Far Press the Focus Far button Increase Brightness Press the Iris Open button Decrease Brightness Press the lris Close button Enter Exit the camera menu Preset 95 or AUX 8 ON Navigate through the camera menu Move the joystick up or down to move through menu selections Increase the value of the selected menu item Press the Focus Far button Decrease the value of the selected menu item Press the Focus Near button PRESETS Refer to the docum
5. rate setting 2 The camera address is not set correctly Check the MRD camera address setting 3 If the baud or address switch settings are changed press the power reset button see Figure 4 Video erratic Control lock up 3 Can not call preset The selected preset has not been defined To clear lock up a Call preset 9 b Define new preset DATA LED is not lit 1 Check connection to the camera 2 Push and hold the power reset button for 5 seconds and then release to recycle power to the camera Refer to Figure 4 SPECIFICATIONS MECHANICAL Construction Aluminum Dimensions 3 30 H x 3 70 W x 1 12 D inches 8 38 x 9 40 x 2 84 cm Electrical 12 24 VAC VDC 10 15 50 60 HZ Power Consumption 1 watt Communication RS 422 half duplex Design and product specifications subject to change without notice PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Exceptions to this warranty are as noted below 1 Model and serial number S 2 Date of shipment P O number Sales Order number or Pelco invoice number Five years on FT FR8000 Series fiber o
6. 1400HZ16 is 4800 baud If the system s control ler switcher uses a different communication rate change the baud rate of the MRD1400HZ16 to match the controller switcher To change the baud rate refer to Figure 1 and Table A Table A Baud Rate Switch Settings Baud Switch Setting Rate 6 7 2400 OFF OFF 4800 ON OFF 9600 OFF ON P EL DEFAULT SWITCH SETTINGS 6 amp 10 ON ALL OTHER SWITCHES OFF 01218 Figure 1 SW 1 Default Switch Settings Pelco Manual C1973M B 8 03 Pelco Manual C1973M B 8 03 MRD ADDRESS SETTINGS A camera address setting is required for the controller switcher to communicate with the MRD1400HZ16 The default setting for the MRD is Receiver Address 1 If you are using more than one MRD each unit must have a different Receiver Address To change the address setting of the MRD refer to Figure 1 and Table B Table B MRD DIP Switch Settings Receiver MRD DIP Switch Setting Address 1 2 3 4 5 1 Off Off Off Off Off 2 On Off Off Off Off 3 Off On Off Off Off 4 On On Off Off Off 5 Off Off On Off Off 6 On Off On Off Off 7 Off On On Off Off 8 On On On Off Off 9 Off Off Off On Off 10 On Off Off On Off 11 Off On Off On Off 12 On On Off On Off 13 Off Off On On Off 14 On Off On On Off 15 Off On On On Off 16 On On On On Off 17 of ot Of Off On 18 On Off
7. Off Off On 19 Off On Off Off On 20 On On Off Off On Of Of On Off On 22 On Off On Off On 23 Off On On Off On 24 On On On Off On 25 Off Off Off On On 26 On Off Off On On 27 Off On Off On On 28 On On Off On On 29 Off Off On On On 30 On Off On On On 31 Off On On On On 32 On On On On On MRD1400HZ16 INSTALLATION METHODS There are three methods of installation for the MRD1400HZ16 The unit can be mounted directly to a wall or installed inside a dome or enclosure using the supplied mount adapters Refer to the following sections and select the correct installation method for your application WALL MOUNTING To mount the MRD1400HZ16 directly to a wall refer to Figure 2 and do the following 1 2 Select the mounting location Install the unit close to the camera Use the MRD1400HZ16 as a template to mark the two fastener positions onto the mounting surface Prepare the surface and install the fasteners Do not tighten fasteners at this time Align the mounting holes of the MRD1400HZ16 with the installed wall fasteners Place the unit over the fasteners and then slide the box down into position Tighten the fasteners to secure the unit to the wall Make all required control power and camera connections Refer to Figure 8 and the Control Power and Camera Connections section of this manual 4 40 PHILLIPS BUTTON HEAD SCREW CAM e swt MRD 1400HZ16 Vates 01220 Figure 2 W
8. all Mounting DF5 DF8 SERIES DOME INSTALLATION To install the MRD1400HZ16 in a DF5 DF8 dome 1 Remove the MRD board from the MRD1400HZ16 To remove the board a Unscrew the two Phillips button head screws from the unit refer to Figure 2 and remove the cover Discard the screws b Using a small screwdriver carefully pry each corner of the board from the PEM studs Refer to Figure 4 Use the four 4 40 Phillips button head screws provided to attach the board to the DF5 DF8 EH2512 Series adapter Assemble the tilt table supplied with the dome For detailed instructions refer to the manual supplied with the DF5 DF8 Series dome Refer to Figure 3 Attach the board to the tilt table with the supplied 10 nut and washer Make all required control power and camera connections Refer to Figure 8 and the Control Power and Camera Connections section of this manual Refer to the manual supplied with the DF5 or DF8 Series dome to install the camera and complete the installation Pelco Manual C1973M B 8 03 CAMERA BRACKET MRD1400HZ16 AND MOUNT ADAPTER 01212 Figure 3 DF5 DF8 Installation POWER LED RESET BUTTON DATA LED 01216 Figure 4 Removing the MRD Board Pelco Manual C1973M B 8 03 EH3512 SERIES ENCLOSURE INSTALLATION Do the following to install the MRD1400HZ16 in an EH3512 Series enclosure 1 Remove the camera sled from the EH3512 Series enclosure If the camera is attached to th
9. e sled remove the camera Attach the camera to the 4 inch camera sled supplied with the MRD Install the cam era sled and camera into the enclosure Place the camera sled as close to the viewing window as possible Remove the PC board from the MRD1400HZ16 To remove the board a Unscrew the two Phillips button head screws from the unit refer to Figure 2 and remove the cover b Using a small screwdriver carefully pry each corner of the board from the PEM studs Refer to Figure 4 Refer to Figure 5 Install the EH3512 adapter into the enclosure Make all required control power and camera connections to the board Refer to Figure 8 and the Contro Power and Camera Connections section of this manual Refer to Figure 6 Position the board over the EH3512 adapter The DIP switches of the board should face up Lightly press on each corner of the board to attach it to the PEM studs of the adapter BACK OF EH3512 ADAPTER PLATE 01213 Figure 5 Installing the EH3512 Adapter PEM STUD MRD 1400HZ16 DIP SWITCHES 01214 Figure 6 Installing the MRD Board onto the EH3512 Adapter Pelco Manual C1973M B 8 03 Pelco Manual C1973M B 8 03 EH2512 SERIES ENCLOSURE INSTALLATION To install the MRD1400HZ16 in an EH2512 Series enclosure 1 Remove the PC board from the MRD1400HZ16 To remove the board a Unscrew the two Phillips button head screws from the unit refer to Figure 2 and remove
10. entation supplied with the controller for instructions on how to set and call a preset Save camera action as preset 1 8 1 8 Set Move to preset position 1 8 1 8 Call Clear control lockup if undefined preset is called Preset 9 Call Enter Exit menu Preset 95 Call AUX Refer to the documentation supplied with the controller for instructions on auxiliary commands Turn camera power on Aux 1 on Turn camera power off Aux 1 off Enable Disable the three digit MRD address display Aux 2 on Turn digital zoom on Aux 3 on Turn digital zoom off Aux 3 off Reset the Camera Aux 4 on Display mirror image on screen left right flip Aux 6 on digital zoom must be enabled Display normal image on screen Aux 6 off digital zoom must be enabled Display current software version for 3 seconds Aux 7 on Enter Exit menu Aux 8 on Subsequent operation must be performed before repeating command Pelco Manual C1973M B 8 03 11 TROUBLESHOOTING Problem Possible Cause and Solutions Unit does not operate No power 1 Check to see if the power LED is lit If the LED is not lit a Verify input power is good b Check power connections to make sure the wires are making contact c Verify the input power source is in range 12 24 volts AC DC Camera does not respond or 1 Check the baud rate of the MRD and the controller switcher Both should have the responds improperly to commands same baud
11. n in this manual prior to installation and operation Pelco Manual C1973M B 8 03 3 DESCRIPTION The MRD1400HZ16 is a camera interface control for Pelco s CC1400HZ16 Series digital color camera The unit can be mounted directly to a wall or installed in a DF5 Series dome DF8A Series dome EH2512 Series enclosure or EH3512 Series enclosure The MRD1400HZ16 can be used with the following Pelco controllers and matrix switchers Controllers direct mode only MPT9500 CM9760 KBD Series KBD200A and KBD300A Matrix Switchers CM6700 Series CM6800 Series CM9740 configured for D or P protocols only Series and CM9760 Series INSTALLATION The following items are supplied Item MRD1400HZ16 DF5 DF8 EH2512 Series adapter EH3500 Series adapter 4 pin connector Data cable 12 inches 4 40 Phillips button head screws 10 nut and washer Camera sled for EH3500 Series enclosure icu iut ui usa M E DIP SWITCH SETTINGS NOTE Saud Adaress Settings f switch settings are changed while the power to the MHD unit is ON push and hold the reset button for five seconds and then release to recycle power and accept the new baud address setting Refer to Figure 4 for the location of the reset button NOTE Dip switches 8 9 and 10 are factory set Do not change switch positions BAUD RATE SELECTION The baud rate must be set for the MRD1400HZ16 to automatically sense D or P protocol The default communication rate for the MRD
12. ptic products 3 Details of the defect or problem Three years on Genex Series products multiplexers server and keyboard 7 If there is a dispute regarding the warranty of a product which does not fall under the Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident
13. r and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date C1973M 10 01 C1973M A 8 02 Revised instructions C1973M B 8 03 Revised supplied parts list and installation instructions for DF5 DF8 and EH2512 enclosures Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Comments Original version Copyright 2003 Pelco All rights reserved 12 Pelco Manual C1973M B 8 03
14. the cover Discard the screws b Using a small screwdriver carefully pry each corner of the board from the PEM studs Refer to Figure 4 2 Use the four 4 40 Phillips button head screws provided to attach the board to the DF5 DF8 EH2512 Series adapter 3 Remove the camera sled from the housing Refer to the manual supplied with the EH2512 Series enclosure 4 Make all required control power and camera connections Refer to Figure 8 and the Control Power and Camera Connections section of this manual 5 Refer to Figure 7 Attach the board to the camera sled of the enclosure with the sup plied 410 nut and washer 6 Refer to the manual supplied with the EH2512 Series enclosure to install the camera and complete the installation MRD BOARD DATA IN CONNECTION Ere N 10 WASHER E 10 NUT 000 01217 Figure 7 EH2512 Series Enclosure Installation CONTROL POWER AND CAMERA CONNECTIONS 1 Refer to Figure 8 and Table C Connect the control wires from the controller to the MRD DATA IN connector Use the supplied four pin connector To connect multiple units with parallel connections refer to Figure 9 2 Connect one end of the 12 inch data cable into the CAM input of the MRD refer to Figure 8 Connect the other end of the cable to the camera connector labeled CON TROL OUT If the installation requires a longer data cable refer to Figure 10 Maximum cable length is 25