Home

Pelco MPS524DT/220 User's Manual

image

Contents

1. b Strip 1 8 from each wire c Using an AMP style crimper crimp the wires and their insulation to the connector pins Refer to Detail A in Figure 1 4 Slide the connector pins into the appropriate holes in the connector body until they snap into place You can see the pin assignments in Table A Table A PIN Assignments PIN FUNCTION 1 Common AC Low 2 Right 3 Left 4 Auto NOTE Pin 5 is not used 5 120 VAC HI for PS20 scanner and camera power or with PS7 and PS30 Series 24 VAC HI for PS20 24 scanner and camera power Scanners 8 Chassis Ground 5 Push the connector clamp assembly towards the connector body and screw it onto the connector body Be careful not to disturb the wires 6 Attach the appropriate clamp with the screws provided and tighten 00103 Figure 1 Connector Assembly Pelco Manual C545M E 2 02 5 COMPLETING THE INSTALLATION 1 Attach the mating connector to the connector on the rear of the scanner control 2 Attach the other end of the cable to the scanner 3 Plug the power cord on the back of the scanner control into a 120 VAC outlet MPS5DT and MPS524DT models or a 230 VAC outlet MPS524DT 220 model OPERATION Tum the control on and test its operation using the following procedures MANUAL OPERATION Move the rocker switch to the MANUAL position When you move the other rocker switch to the LEFT position the scanner pans
2. PELCO MPS5DT MPS524DT MPS524DT 220 Scanner Controls Installation Operation Manual C545M E 2 02 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA Pelco Online www pelco com In North America and Canada Tel 800 289 9100 FAX 800 289 9150 DataFAX 800 289 9108 International Customers Tel 1 559 292 1981 FAX 1 559 348 1120 DataFAX 1 559 292 0435 PelcoEurope BV Dillenburg Center Dillenburgstraat 7C 5652 AM Eindhoven The Netherlands Tel 31 40 251 9870 FAX 31 40 251 9835 CONTENTS Section INSTALLATION 0 eeeaeee CONNECTOR ASSEMBLY COMPLETING THE INSTALLATION OPERATION rere tenens SPECIFICATIONS esse REGULATORY NOTICES WARRANTY AND RETURN INFORMATION LIST OF ILLUSTRATIONS Figure 1 Connector Assembly 2 Dimension Drawing LIST OF TABLES Table A PIN Assignments Pelco Manual C545M E 2 02 IMPORTANT SAFEGUARDS AND WARNINGS Pelco Manual C545M E 2 02 Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes 2 Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclo sure it is designed for indoor use only and it must not be installed where expose
3. in Section 4 1 C545M D 6 96 Rev D Figures 5 and 6 revised to include new wire colors and new transformer part TRF22282 30 70F 3 97 Fuse value updated in Figure 6 5 97 Manual formatted to new style Optional R300 Rack mount instructions removed Figures 4 and 5 updated per ECO 97 125 wiring colors and connections C545M E 2 02 Manual formatted to new style New scanner models added Figures 2 4 removed Copyright 2002 Pelco All rights reserved Pelco the Pelco logo Spectra Genex and Legacy are registered trademarks of Pelco TM Esprit and Camclosure are trademarks of Pelco 8 Pelco Manual C545M E 2 02
4. please include a written explana tion with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization num ber CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico Intermediate Consignee Ultimate Consignee American Overseas Air Freight Pelco 320 Beach Road 3500 Pelco Way Burlingame CA 94010 Clovis CA 93612 5699 USA USA REVISION HISTORY Manual Date Comments C545M 3 85 Original version C545M 1 90 Rev A Revised to include MPS524DT 220 C545M 9 90 Rev B Revised page 2 and Figures 2 and 6 C545M C 10 94 Rev C Revised to 2 Column Format Incorporated new wiring diagrams Figs 5 and 6 and updated fuse values per ECO 94 482 Revised Figure 2 and cable assembly instructions
5. to the left When you move it to the RIGHT position the scanner pans to the right AUTO SCAN OPERATION Move the rocker switch to the AUTO position The scanner pans to the right until it reaches its limit then pans to the left The scanner automatically continues right left panning until the MANUAL switch is set again or the scanner is turned off SPECIFICATIONS CONTROLS Left Right Rocker switch LEFT RIGHT Auto Scan Rocker switch AUTO MANUAL Power Rocker switch ON OFF Pilot Lamp Long life neon ELECTRICAL Input Voltage MPS5DT MPS24DT 120 VAC 50 60 Hz MPS524DT 220 230 VAC 50 60 Hz Output Voltage MPS5DT 120 VAC MPS24DT 24 VAC MPS524DT 220 24 VAC Maximum Power Reauirements PS7 24 PS30 24 PS30A PS20 PS20 24 MPS5DT 17 5 VA 30 VA MPS524DT 8 8 VA 13 VA 20 VA MPS524DT 220 8 8 VA 13 VA 20 VA Fuse Protection MPS5DT 1 4 ASB MPS524DT 1 2 ASB MPS524DT 220 2 10 ASB Pelco Manual C545M E 2 02 Power Cord Output Connector Cable Requirements Operating Distances GENERAL Construction Cover Chassis Panel Unit Size Unit Weight MPS5DT MPS524DT MPS524DT 220 Unit is supplied with grounded power cord either U S Standard or Continental European Standard AMP CPC type 14 pin mate supplied 4 conductors for PS7 PS30 models and 6 for PS20 PS20 24 models The following are the recommende
6. ance up to 13 000 feet using 16 AWG MODELS MPS5DT MPS524DT MPS524DT 220 OPTIONS R300 RB115 RB24 Desktop control for 120 VAC scanners PS20 PS30A UL Desktop control for 24 VAC scanners PS7 24 PS20 24 PS30 24 UL Same as MPS524DT except with 230 VAC input Desktop control for 24 VAC scanners PS7 24 PS20 24 PS30 24 CE Rack mount kit Up to three units can be racked horizontally in a single rack kit Low voltage relay box for use with 24 VAC control and 120 VAC scan ners Extends operating distance control to relay box up to 13 000 feet using 16 AWG Low voltage relay box for use with 24 VAC control and 24 VAC scan ners Extends operating distance control to relay box up to 13 000 feet using 16 AWG Pelco Manual C545M E 2 02 INSTALLATION The following items are supplied MPS5DT MPS524DT or MPS524DT 220 6 pin mating connector with pins 2 screws CONNECTOR ASSEMBLY The first thing you must do is assemble the mating connector The following steps apply to all AMP style connectors regardless of pin size or pin number Refer to Figure 1 during as sembly 1 Slide the connector clamp assembly over the conductor cable 2 Determine the size of wire to use Refer to the Specifications section 3 Prepare the wires from the conductor cable as follows a Strip at least 1 from the cable jacket to expose the wires You may need to strip more from the cable jacket if you have more wires
7. d cable distances between the control and the listed scanners The PS20 and PS20 24 are pow ered locally and do not use power from the controller 20 AWG 18 AWG 16 AWG 0 5mm 1 0mm 1 5 mm pera a WM reson ge psaoza oi ba 80 mj PS20 m T mn 1 am PS20 24 em En icon NOTE A relay box can be used to extend the maximum operating distance control to relay box to 13 000 feet using 16 AWG Steel black polyester powder coat Steel zinc plated Aluminum black polyester powder coat with white silkscreen 5 50 W x 1 75 H x 8 90 D inches 13 97 x 4 45 x 22 61 cm Refer to Figure 2 3 Ib 1 36 kg 4 Ib 1 80 kg 4 Ib 1 80 kg Design and specifications are subject to change without notice ho 22 61 gt j 5 50 13 97 F Pelco Manual C545M E 2 02 Y REAR VIEW NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 2 Dimension Drawing REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class A digital de vice pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may caus
8. d to rain or moisture 3 Only use replacement parts recommended by Pelco 4 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts and have not been connected to line circuitry The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit maintenance instructions in the literature accompanying this This symbol indicates that there are important operating and unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Please thoroughly familiarize yourself with the information in this manual prior to installation and operation DESCRIPTION The MPS5DT and MPS524DT Scanner Controls provide precise and reliable control of Pelco PS20 and PS20 24 Series Scanners The controls can still be used with older scan ner models such as Pelco PS7 PS7 24 PS30A and PS30 24 An additional line is available to power the PS20 scanner and camera enclosure eliminating the need for power at the scanner location The front panel switches operate left and right control and automatic scan control These controls can be used as desktop models or up to three units can be rack mounted in a R300 Rack Kit Use the RB24 Relay Box to extend the control s operating dist
9. e date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringe ment of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages includ ing loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above
10. e harmful in terference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the in terference at his own expense WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 and MC3500 MC3600 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard Two years on cameras and all standard motorized or fixed focal length lenses Two years on Legacy Camclosure Camera Systems CM6700 CM6800 CM8500 CM9500 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from th