Home

Pelco C538M User's Manual

image

Contents

1. o See Seam emo Kegpe N Dee nee gt COMMUNICATION CARD O amp O esie RS 422 INPUT PORT PORT FEMALE CM9760 IRC RS 422 OUTPUT Pelco Manual C544M 2 98 Figure 1 CM9760 IRC Rear View 2 1 GENERAL FEATURES The Pelco 9760 IRC is housed in a rack frame and connects to one Sercom port on the rear of the CM9760 CC1 A fully populated Pelco 9760 IRC unit consists of the following a One communication card interfaces with CM9760 CC1 b Four VCR control cards Each control card controls a Upto 32 VCRs b Up to four different VCR brands and or models Up to 128 VCRs can be controlled by one unit Up to 16 IRC units can be linked in sequence that is daisy chained giving control of up to 2 048 VCRs refer to Figure 2 The control cards accept messages from the CM9760 CC1 in the same manner as a normal GPI General Purpose Interface relay card VCR control signals are transmitted by infrared control cable IR control cable attached to the VCR lt O VCR VCR CM9760 IRC VCR 128 VCRs CM9760 CC1 CPU EET VCR VCR CM9760 IRC VCR ANOTHER 128 VCRs UP TO 16 VCR VCR VCR VCR VCR VCR CM9760 IRC UP T
2. 13 40 SPECIFICAT ONS 1 2 rdiet since des iren er ceo 14 5 0 WARRANTY AND RETURN INFORMATION 16 LIST OF ILLUSTRATIONS Figure 1 CM9760 IRC Rear View esee 2 VCR Hook up Parameters 3 Sample System Hook up 4 Communication 5 DIP SWIICIIBS icin farce din Reet acento 6 The Number of VCRs Controlled by One Control Card 8 7 Pinouts for Connecting an IRC to a CPU 9760 CC1 Host 10 8 Connecting IRCs in Sequence pp 11 9 Data Pin Connections for IRCs in Sequence 11 10 Connecting VCRs to the CM9760 MXB Video Matrix Bay 12 LIST OF TABLES Table Page A Baud Settings 2 1 eene ec e ca de E eo 8 B StartAddresses c sits Shas Ss SE 9 C Start Addresses aa sed edt eese toe est ee er a sae 9 D IR Control Cable Wiring pe 13 REVISION HISTORY Manual Date Comments C544M 2 98 Original version 2 Pelco Manual C544M 2 98 1 0 GENERAL 1 1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes 2 Only use replacement parts recommended by Pelco 3 After replacement rep
3. Matrix Bay 5 Connect the IR control cables to the VCRs 6 Each step listed above is detailed below 3 1 COMMUNICATION CARD The communication card refer to Figure 4 has a bank of eight DIP switches used to do the following Set the operating baud of the unit 1 Set the start address 2 In Figure 5 DIP switch number 2 is ON N 000 C5500 o Soo o _ 5 N zoo e wo zo mmo N amp Poo NOHO Le N e eo w i e N BODO 3 DORAO gt CM9760 IRC COMMUNICATION CARD Figure 4 Communication Card 2 3 14 1516171 8 1 q i uim o CD a i 5 S iL Pelco Manual C544M 2 98 3 1 1 NOTE The operating baud must match the baud rate set in the SCP Communications File for the CM9760 CC1 Setting the Baud Bauds of 2400 4800 9600 and 19200 are available The communication protocol uses eight data bits one stop bit and even parity The baud is set using DIP switches 1 and 2 according
4. for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair Goods returned for repair or credit should be clearly identified with the assigned CA RA number and freight should be prepaid All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Ship freight prepaid to Pelco 300 West Pontiac Way Clovis CA 93612 5699 Pelco Manual C544M 2 98
5. to Table A Table A Baud Settings 3 2 CONTROL CARD NOTE The VCRs connected to a single microprocessor must be in the same brand and model Brands and models required should be specified at the time of order CM9760 IRC UP TO 4 CONTROL CARDS PER IRC 4 MICROPROCESSORS PER CARD i The CM9760 IRC can have up to four control cards installed Each control card has four microprocessors Each microprocessor controls two DB9 output connections Each DB9 output controls up to four VCRs refer to Figure 6 This enables one Pelco CM9760 IRC to have infrared control of 128 VCRs that is four control cards multiplied by four microprocessors per card multiplied by two DB9 outputs per microprocessor multiplied by four VCRs per DB9 output equals 128 VCRs 2DB9 OUTPUTS PER MICROPROCESSOR J1 CM9760 CC1 4 VCRs PER DB9 OUTPUT zu VCR VCR VCR VCR VCR VCR CONTINUES UP TO 32 VCRs PER CARD VCR VCR IR LED CABLES Figure 6 The Number of VCRs Controlled by One Control Card Pelco Manual C544M 2 98 3 2 1 Setting the Start Address Each Pelco CM9760 IRC unit requires a six bit start address The start address is configured using the DIP switches on the commun
6. 3 BUSY PING BUSY PIN 7 BUSY _ PIN7 BUSY PIN 4 RX _ PIN 4 TX 8 8 5 PIN5 RX PIN9 TX PIN9 RX Figure 9 Data Pin Connections for IRC s in Sequence Pelco Manual C544M 2 98 11 3 5 CONNECTING VCRs TO THE VIDEO MATRIX BAY CM9760 MXB VCRs must be connected to the CM9760 MXB Video Matrix Bay Two standard coaxial cables are needed 1 One to run from the VIDEO OUT port on the back of the VCR to the desired IN port on the VMB 2 The other to run from the VIDEO IN port on the VCR to the desired OUT port on the Video Matrix Bay VCR REAR VIEW VIDEO IN CM9760 MXB VIDEO MATRIX BAY DU X gt s 0 GE 0 ee CO INPUT PORTS UP TO 16 CARDS 16 PORTS PER CARD OUTPUT PORTS 1 CARD 16 PORTS PER CARD Figure 10 Connecting VCRs to the CM9760 MXB Video Matrix Bay 12 Pelco Manual C544M 2 98 3 6 VCR CONTROL SIGNAL OUTPUTS An IRC has up to 32 D9 female output connections numbered J1 to J32 each able to control four VCRs refer to Figure 6 Every DB9 output supports four IR control cables Each IR control cable controls the functions of a single VCR The wiring for each DB9 output is shown bel
7. ADDENDUM Addendum No 1577 Date August 4 2004 Manuals Affected CM9760 Series Manuals 538M C539M A C540M B C541M C C542M B C543M A C544M C549M A C572M C573M D C578M C579M C1501M C1503M 1510 0 C1510M A C1520M B C1528M C C1940M C1941M C1942M and C1943M Manual Update The CM9760 CC1 has been replaced with the CM9700 CC1 and the CM9760 MGR manage ment software has been replaced with the CM9700 MGR management software Keep the following in mind when referring to the instructions contained in these manuals e The CM9700 CC1 contains the latest CC1 software version 9 01 or higher and is programmed with the new CM9700 MGR management software e Despite the difference in model numbers the CM9700 CC1 functions the same as the CM9760 CC1 and most of the information in these manuals applies to version 9 01 or higher CPU e You can add the CM9700 CC1 to an existing CM9760 system if you upgrade the existing CM9760 CC1 units with the current software version level 9 01 or higher Software version 9 01 requires a minimum of 16 MB of RAM in the CPU If required you can upgrade the RAM in older CM9760 CC1 units using the software upgrade kit appropriate for your CPU e Do not use the CM9760 MGR instructions contained in these manuals Refer to the CM9700 MGR Getting Started Software Guide on screen help or Online Help for instructions Pelco World Headquarters 3500 Pelco Way Clovis Califo
8. O TOTAL OF 2 048 VCRs Figure 2 VCR Hook up Parameters Pelco Manual C544M 2 98 5 2 2 SAMPLE SYSTEM A typical system installation involving the CM9760 IRC might include a CM9760 CC1 e Monitors b CM9760 IRC f Cameras c 9760 g 9760 d VCRs Other Pelco products can be added according to system requirements PELCO CM9760 C1 PELCO CM9760 IRC PELCO CM9760 KBD CM97604RC i ote oos VCR CONTROL SIGNAL TO IR LED ASSEMBLY 4 PER IRC DB9 TO IRC WITH NEXT START ADDRESS gt OR NOT CONNECTED IF IRC IS LAST I PELCO CM9760 MXB VIDEO MATRIX BAY agile CigPRs 288275 Caps 88s ERE lt A ANNs DEAE SP N CHAIN VIDEO SIGNAL FROM VCR OUT CONNECTOR ONE PER VIDEO A VIDEO SIGNAL FROM VCR IN CONNECTOR ONE PER VIDEO Figure 3 Sampl e System Hook up Pelco Manual C544M 2 98 INSTALLATION 3 To install the Pelco Infrared VCR Controller proceed as follows Set the baud 1 Set the start address 2 Connect the CM9760 IRC to the CM9760 CC1 host 3 Connect additional IRC units in daisy chain fashion 4 MXB CM9760 Connect VCRs to the Video
9. RS 422 port on the IRC The data pin connections are shown below in Figure 7 PIN 1 TX PIN 2 TX PIN 7 RX PIN 8 RX4 CONNECT VIA CABLE PIN 5 RX PIN 9 RX PIN 8 TX PIN 4 TX4 CM9760 IRC RS 422 DB9 PORT MALE IN Figure 7 Pinouts for Connecting an IRC to a CPU 9760 CC1 Host 10 Pelco Manual C544M 2 98 3 3 1 Connecting the CM9760 IRC to a CM9760 CC1 Host via Serial A CM9760 IRC can be daisy chained from a serial GPI already connected to a SerCom port of CM9760 CC1 CPU The wiring is the same as for Section 3 3 Connect the RS 422 OUT port of the serial GPI to the RS 422 IN port of the IRC refer to Figure 8 CM9760 CC1 SERCOM PORTS FEMALE 9760 IRC 9760 IRC 9760 IRC 9760 IRC IN IN IN n e id ecce S Como eve A o Figure 8 Connecting IRCs in Sequence 3 4 CONNECTING ADDITIONAL IRCs IN SEQUENCE NOTE Sixteen is the maximum Up to 16 IRC units can be daisy chained from one port of the CM9760 CC1 host number of racks that can be daisy chained from one port of the host The RS 422 OUT port of the first IRC must be connected to the RS 422 IN port of CPU the next IRC in the chain refer to Figure 8 The data pin connections are shown below in Figure 9 CM9760 IRC CM9760 IRC RS 422 DB9 PORT CONNECT RS 422 DB9 PORT FEMALE VIA CABLE MALE OUT IN PIN
10. air of this unit s electrical components conduct a resis tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit maintenance instructions in the literature accompanying this unit 1 This symbol indicates that there are important operating and CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Please thoroughly familiarize yourself with the information in this manual prior to installation and operation Pelco Manual C544M 2 98 3 stop fast forward rewind and pause Eject control depends on the VCR model equipped with an infrared receiver for controlling standard functions play record This reduces the need for modifications to VCRs The Pelco 9760 IRC VCR Controller provides remote control of most VCRs DESCRIPTION 2 See lee 5eCRe Joce FOE eue e N Sene rene CONTROL CARDS x rece e N TODA gt gt rece N o TOLEDO gt gt i DB9 OUTPUT CONNECTIONS FEMALE
11. ication card see Figure 5 DIP switches Each control card occupies one address space An IRC unit occupies four address spaces if there are only two control cards in the unit it still occupies four address spaces The start address of an IRC unit is set with the DIP switches on the communication card per Table B Table B Start Addresses DIP DIP DIP DIP DIP DIP Start Address Start Address Switch 8 Switch 7 Switch 6 Switch 5 Switch 4 Switch 3 Binary Decimal NOTE It is necessary only to set the Unlike an IRC unit a serial occupies one address space In the sample system start address of the IRC as a whole outlined in Figure 3 the start addresses would set up according to Table C The start address of each control card in the unit is set by internal de fault Table C Start Addresses Serial GPI 000000 Set via serial GPI communication card DIP switches Control card 2 Control card 3 Control card 4 000010 Automatic internal default 000011 Automatic internal default 000100 Automatic internal default IRC unit 1 control card 1 1 000001 Set via IRC unit 1 communication card DIP switches Pelco Manual C544M 2 98 9 CM9760 CC1 SERCOM FEMALE ON OARWN 3 3 CONNECTING THE CM9760 IRC TO THE CM9760 CC1 HOST Each CM9760 IRC has two RS 422 ports one labeled IN male and the other OUT female To connect a CM9760 IRC to the CM9760 CC1 host connect a SerCom port on the host to the IN
12. oss result ing from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Ship freight prepaid to Pelco 300 West Pontiac Way Clovis CA 93612 5699 Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory
13. ow in Table D Table D IR Control Cable Wiring s ome vor er s omes vene ene Bare a fF WN o 3 6 1 Transmitting VCR Commands NOTE Once installation has been Connect an IR control cable to one of the DB9 infrared output connections on the completed the appropriate program IRC Run the cable to the target VCR ming must be made in the 9760 Con For best results in transmitting the VCR commands play record stop fast for figuration files ie SCP GPI CAM iy play ward rewind pause the IR LED at the end of the IR control cable must be placed directly over the receiving port on the front of the VCR Pelco Manual C544M 2 98 13 4 0 SPECIFICATIONS 14 Electrical Specifications Operating Voltages 120 or 230 VAC 50 60 Hz 10 selectable Power Consumption 15 vA per control card and communication card Operating Temperature Range 32 to 122 F 0 to 50 C Communications Serial Communication Ports One input port balanced RS 422 One output port balanced RS 422 Serial Communication Setup Baud rate 2400 4800 9600 or 19200 Data bits 8 Stop bits 1 Parity bit Even Mechanical Connectors One 9 pin DB9 input connector male One 9 pin DB9 output connector female Thirty two 9 pin DB9 output control connectors female Unit Weight 6 61 Ibs 3 kg Dimensions 5 24 H x 19 02 W x 9 45 D 13 3 cm x 48 3 cm x 24 0 cm Ty
14. pe of Mounting 19 48 26 cm rack mount 3 RUs Design and product specifications subject to change without notice Pelco Manual C544M 2 98 NOTES Pelco Manual C544M 2 98 5 0 WARRANTY AND RETURN INFORMATION GPelco and the Pelco logo are registered trademarks of Pelco Copyright 1998 Pelco All rights reserved 16 WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one 1 year after the date of shipment Exceptions to this warranty are as noted below Two 2 years on all standard motorized and fixed focal length lenses e Two 2 years on Legacy Intercept PV1000 Series CM6700 CM8500 CM9500 CM9750 CM9760 Matrix Spectra M DF5 Series and DF8 Fixed Dome products Two 2 years on WW5700 series window wiper excluding wiper blades Two 2 years on cameras Six 6 months on all pan and tilts scanners or preset lenses used in continu ous motion applications e g preset scan tour and auto scan modes Pelco will warranty all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or l
15. rnia 93612 5699 USA www pelco com PELLO USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 CM9760 IRC Infrared VCR Controller Installation Operation Manual C544M 2 98 Pelco 300 W Pontiac Way Clovis CA 93612 5699 USA Pelco Online http www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 DataFAX 800 289 9108 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 DataFAX 1 559 292 0435 CONTENTS Section Page 1 0 GENERAL 3 1 1 IMPORTANT SAFEGUARDS AND WARNINGS 3 2 0 rnt nter 2 1 GENERAL FEATURES js e 2 2 SAMPLE SYSTEM ertet e E Reda cnl 3 0 INSTALLATION ire nere Er atte Hie vie E eret 3 1 COMMUNICATION CARD 3 1 1 Setting the Baud hip an e Aa 3 2 CONTROL GARD 3 2 1 Setting the Start Address 9 3 8 CONNECTING THE CM9760 IRC TO THE CM9760 CC1 HOST 10 3 3 1 Connecting the CM9760 IRC to a CM9760 CC1 Host via Serial GPI 11 3 4 CONNECTING ADDITIONAL IRCs IN SEQUENCE 11 3 5 CONNECTING VCRs TO THE VIDEO MATRIX BAY CM9760 MXB nnns enn neni 12 3 6 VCR CONTROL SIGNAL OUTPUTS