Home
Pelco Blower BK3512-2 User's Manual
Contents
1. connected to the line circuitry posed to dripping or splashing and that no objects filled with liquids k of fire or electric shock do not expose this apparatus to rain or 4 Installation should be done only by qualified personnel and conform to all local codes 5 Use only installation methods and materials capable of supporting four times the maximum specified load 6 CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than contained in the operating instructions unless you are qualified to do so 7 Only use replacement parts recommended by Pelco 8 After replacement repair of this unit s electrical components conduct a resistance e and exposed parts to verify the exposed parts have not been The product and or manual may bear the following marks A AN This symbol indicates th constituting a risk of electric shock is present within this unit at dangerous voltage CAUTION This symbol indicates th at there are important RISK OF ELECTRIC SHOCK operating and maintenance instructions in the DO NOT OPEN literature accompanying this unit C1436M G 2 06 Description You can install the BK3512 Series blower kit only in enclosures in the EH3512 Series EH3515 Series and EH3515L Legacy Series MODELS BK3512 1 Blower kit continuous duty 120 VAC 4 watts BK3512 2 Blower kit continu
2. viewing window C1436M G 2 06 3 5 Connect the blower wires directly to power or if there is a heater and defroster installed you will need to connect the blower wires to the PC board To remove the PC board cover insert a screwdriver into the slot on top of the cover and lift the cover off Connect the blower wires to the PC board refer to Figure 3 If required connect ground to the stud on the bottom of the enclosure just in front of the PC board Replace the PC board cover making sure it snaps securely back into place Be sure the blower wires are not obstructing other accessories in the enclosure If you are installing the BK 3512 2 blower kit 24 VAC refer to Table A 6 If you removed the camera and camera sled reinstall them 7 Close the enclosure lid and latch 8 Reconnect power to the enclosure SCREW FRONT Hi HEATER LOCK WASHER BRACKET Figure 1 Blower Kit Installation in Enclosure with Rear Heater C1436M G 2 06 Figure 2 Blower Kit Installation in Enclosure without Rear Heater 120 VAC MODEL 24 VAC MODEL o o O INPUT AC HIGH INPUT AC HIGH is INPUT AC LOW NEUTRAL 1 6 INPUT AC LOW NEUTRAL 2 e 2 e 3 e 3 jo RED RED 4 e 4 e DIODE 518 BLOWER s le BLK BRIDGE JES BLOWER 6 e 6 e CAPI 7 e 70 8 e slo 9 e 9 e 10 le 10 e o o 230 V
3. AC MODEL o O INPUT AC HIGH NOTE THE DEFROSTERALSO INPUT AC LOW NEUTRAL IS CONNECTED TO TERMINALS 4AND 5 120 VAC BLOWER M RESISTOR SDoanaunwun O 0000000000 Figure 3 Wiring Diagrams for PC Board C1436M G 2 06 Table A 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Wire Gauge 20 18 16 14 12 10 10 283 86 451 137 716 218 1142 348 1811 551 2880 877 5 20 141 42 225 68 358 109 571 174 905 275 1440 438 E E 30 94 28 150 45 238 72 380 115 603 183 960 292 S a0 70 21 112 34 179 54 285 86 452 137 720 219 5 3 R 50 56 17 90 27 143 43 228 69 362 110 576 175 E E Example An enclosure that reguires 30 VA and is installed 94 feet 28 m from the transformer would reguire a minimum wire gauge of 20 AWG NOTE Distances are calculated in feet values in parentheses are meters This eguipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for proc
4. INSTALLATION BK3512 Series Blower Kit C1436M G 2 06 Important Safety Instructions Prior to installation and use of this product the following WARNINGS should be observed 1 Read these instructions Keep these instructions 8 Do not appara 2 3 4 Follow all instructions 5 Do not use this 6 7 Heed all warnings Clean only with dry cloth apparatus near water Do not block any ventilation openings Install in accordance with the manufacturer s instructions install near any heat sources such as radiators heat registers stoves or other us including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand with th comb 11 Refer all servicing to qualified has been damaged in any spilled or objects have fallen i tripod bracket or table specified by the manufacturer or sold e apparatus When a cart is used use caution when moving the cart apparatus nation to avoid injury from tip over service personnel Servicing is required when the apparatus way such as power supply cord or plug is damaged liquid has been nto the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 2 Apparatus shall not be ex such as vases shall be placed on the apparatus 3 WARNING To reduce the ris moisture measurement between the lin
5. e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Auth
6. edures for recycling this equipment BD C1436M G 2 06 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty e Three years on PMCL 200 300 400 Series LCD monitors e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products e Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders Endura Series distributed network based video products and TW3000 Series twisted pair transmission products
7. orization number RA and provide the following information Model and serial number 2 Date of shipment PO number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER
8. ous duty 24 VAC 2 watts BK3512 3 Blower kit continuous duty 230 VAC 9 watts Installation The following items are supplied 1 Blower 2 Screws BK3512 1 3 6 32 x 1 1 2 inch Phillips pan head BK3512 2 6 32 x 1 3 8 inch Phillips pan head 2 Internal star lock washers Perform the following steps to install the BK3512 blower kit 1 Disconnect all sources of power from the enclosure 2 Unlatch and open the lid 3 If necessary remove the camera and camera sled a Disconnect the power and video from the camera b Loosen the screws that hold the camera sled in place c Slide the sled forward so it can be lifted out over the screws Do not lift the sled out yet Retighten the screws so the sliding bar under the sled lip will not move This will assure that you reinstall the camera and sled in the same place e Remove the camera and sled 4 Do one of the following e f you have an EH3515 Series enclosure with a heater and defroster installed do the following a Remove the screws attaching the rear heater bracket to the enclosure b Place the blower against the rear heater bracket and attach using the screws and lock washers provided refer to Figure 1 Be sure the arrow on the blower housing is pointing toward the viewing window e Place the blower against the rear of the enclosure and attach using the screws and lock washers provided refer to Figure 2 Be sure the arrow on the blower housing is pointing toward the
9. send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C1436M G 2 06 Revised to new format Added cover photo Updated per ECO 04 10624 which added PCB cover and ground stud Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Copyright 2006 Pelco Endura and ExSite are trademarks of Pelco All rights reserved DLP is a registered trademark of Texas Instruments Inc PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East