Home

Pelco AUX2000 User's Manual

image

Contents

1. AUX2000 Auxiliary Control Box Installation Operation Manual C916M 11 90 Pelco 3500 Pelco Way Clovis CA 93612 5699 USAwww pelco com In North America and Canada Tel 800 289 9100 FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 TABLE OF CONTENTS Section Page 1 0 WARNINGS arica a 1 A TN 2 3 0 IDESGRIPTIONe lenze uni 2 MODEL NUMBERS cases esti bad rad ate a ra kas Praia dido 2 3 2 RECOMMENDED CONTROLS arara arara aaa 2 4 0 INSTALLATION ico tas rossi Du S Dau h ba qa q SS a ACE 3 4 1 MATING CONNECTOR ASSEMBLY 4 5 09 OPERATION m a line 5 5412 SYSTEM TESTA os nd aa a i 5 6 0 TROUBLESHOOTING GUIDELINES 5 7 0 AUX2000 MECHANICAL PARTS LIST 6 8 0 ELEGTRICAL PARES STi aa ean dda aaa ida 6 9 0 SGHEMALIOS le e io 7 10 0 SPECIF OAT O NO aa ila ni Rea 8 11 0 WARRANTY AND RETURN 0 0640000 10 LIST OF ILLUSTRATIONS Figure Page 1 Output Circuits citan 3 2 Mating Connector Assembly Diagram nana cnc nana anna 4 3 AUX2000 Schematics i 2a tii 7
2. Pelco and the Pelco logo are registered trademarks of Pelco OCopyright 1990 Pelco All rights reserved ii Pelco Manual C916M 11 90 INSTALLATION OPERATION MANUAL AUX2000 AUXILIARY CONTROL BOX FOR THE COAXITRON AND WIRETRON RECEIVER DRIVER 1 0 WARNINGS Prior to installation and use of this product the follow ing WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Lo cal codes Unless the unit is specifically marked as a NEMA 3 3R 35 4 6 enclosure it is de signed for Indoor use only and it must not be in stalled where exposed to rain and moisture The product may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION TOREDUCE THE RISKOF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Only use replacement parts recommended by Pelco After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the ex posed parts have not been connected to line cir cuitry The installation methods and materials should be capable of supporting four 4 times the weight of the AUX2000 This symbol indicates that there are important operating and maintenance instructions in t
3. IRIS LEFT DOWN UP RIGHT GROUND FEED THROUGH TO ENCLOSURE CAMERA AC HIGH IRIS FOCUS ZOOM LENS COMMON CAMERAAC LOW AUX 1 OUTPUT TO A LAMP AUX 2 OUTPUT TOA MOTOR AC HI AUX 3 AC NEUTRAL OUTPUT CIRCUITS ARE RATED FOR 120 VAC 1 AMP 120 VA MAXIMUM EACH Figure 1 Typical Output Circuits Pelco Manual C916M 11 90 3 4 1 MATING CONNECTOR ASSEMBLY 4 The contact pins supplied with the mating connec tor are the crimp type which may also be sol Installation and or testing will require you to assemble dered if you so desired item 4 the connector parts provided Fabricate the intercon necting cable according to the following steps refer 5 After crimping or soldering the contact pins to the ence Figure 2 conductors push them into the proper holes in the connector until they snap in place 1 Slide part A of the cable clamp item 1 over the end of the cable item 1 part C with the threaded end NOTE Contacts cannot be removed from the of the cable clamp facing the connector item 5 connector without the use of the appropriate AMP extraction tool which is available from 2 Ifthe cable has a diameter less than 1 2 inch 1 3 cm Pelco slide the rubber boot item 2 over the end of the cable and pull through the cable clamp to so that the 6 Slide part A of the cable clamp toward the connec boot encases the cable and forms a good seal tor and screw the parts together Attach part B i
4. includ ing when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications thatis preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the neglig
5. lbs 36 45 kg ELECTRICAL Input Voltage 120 VAC Power Requirements 360 VA Power Cord 18 3 AWG listed SJT Fuse Protection 3 amp Connectors AMP CPC type Conductor Requirements Minimum 20 AWG Cable Distance Wire Maximum Distance Maximum Distance Gauge In Feet meters In Feet meters 495 150 9 1 490 454 2 310 94 5 940 286 5 195 59 4 590 179 8 One amp load for each auxiliary function and one common neutral One amp for each auxiliary function and one neutral conductor for each auxiliary function Pelco Manual C916M 11 90 NOTES Pelco Manual C916M 11 90 11 0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years FT FR8000 Series fiber optic products Three years on Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses e Two years Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners
6. 1 800 289 9100 The TAP Line is available 24 hours a day seven days a week Pelco Manual C916M 11 90 7 0 AUX2000 MECHANICAL PARTS LIST Enclosure DS100JA4000COMP Fuse holder FUS357001 Terminal Strip TRS20007 Strain Relief EH5510043 Mating Connector Sockets 75 Mating Connector Pins CONA37P 8 0 ELECTRICAL PARTS LIST CON1 Connector 37 pins CON206151 1 CON2 CON3 Connector 6 position CON640428 6 CON4 CONS Connector 2 position CON640428 2 Connector 37 sockets CON206306 1 Fuse 3 AMP 3AG FUS3 Choke 6 2 Microhenery s 4610 Plug 1 Cord 18 AWG SJT WIRC1318006BL RY1 RY3 Relay 120VAC SPST REL120A01MP 6 Pelco Manual C916M 11 90 9 0 SCHEMATICS Lona XNV L XNV SNI WOOZ sn904 SIYI HDIH IVANVIA NONNO HONOYHL 0333 LXNV NONINOO SN31 WOOZ SNOO4 SIYI HDIH OV VH3NVO IVANVIA NONNOO Figure 3 AUX2000 Schematics Pelco Manual C916M 11 90 10 0 SPECIFICATIONS MECHANICAL Enclosure UL listed gray industrial control panel enclosure Weatherproofing Cover and connectors fully gasketed Mounting Means 6 0 31 79 cm diameter holes Dimensions 11 31 H x 9 44 W x 4 32 D 28 7 cm x 4 25 cm x 10 97 cm Unit Weight 7 lbs 3 15 kg Shipping Weight 9
7. 24RX except for in door use CX9224RXI 12V Same as CX9224RXI except with 12 VDC camera power WX8024RX Wiretron receiver in weatherproof box for 24 VAC pan tilts zoom lens 24 VAC camera power and four ac cessory functions WX8024RXI Same as WX8024RX except for in door use WX8224RXI Same as WX8024RXI except with 24 VAC power input WX8115RX Wiretron receiver in weatherproof box for 120 VAC pan tilts zoom lens 120 VAC camera power and four accessory functions Pelco Manual C916M 11 90 4 0 INSTALLATION Refer to the following instructions when installing the AUX2000 auxiliary control box for the Coaxitron and Wiretron receiver drivers 1 Determine the location for the AUX2000 auxiliary control box for the Coaxitron or Wiretron receiver drivers To determine the mounting location con sider the distance between the AUX2000 auxiliary control box for the Coaxitron and Wiretron receiver drivers and auxiliary functions used Attention should be given to the wire distance table shown above 2 Using the AUX2000 auxiliary control box for the Coaxitron and Wiretron receiver drivers box as a template mount the box to the desired location using the fasteners not supplied which will sup port the full load of the unit 3 Assemble the mating connector as described in Section 4 1 4 Connect the auxiliary device as shown in Figure 1 5 Plug the AUX2000 into a 120 VAC source P T COMMON MANUAL
8. elco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following Ifthe goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco O Copyright 1990 Pelco All rights reserved
9. ence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state Ifa warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem Ifthere is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In orderto expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 P
10. he literature accompanying this unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Please thoroughly familiarize yourself with the information in this manual prior to installation and operation Pelco Manual C916M 11 90 2 0 SCOPE The information contained within this manual covers the installation and operation of the AUX2000 3 0 DESCRIPTION The AUX2000 is an auxiliary control box for the Coaxitron and Wiretron receiver drivers It enables the logic level AUX 1 3 signals from the Coaxitron and Wiretron receiver drivers to control devices such as motors for motor operated gates lights for parking ar eas or power relays for high power requirements 3 1 MODEL NUMBERS AUX2000 Auxiliary control box for the Coaxitron and Wiretron receiver drivers 2 3 2 RECOMMENDED CONTROLS CX9024RX Coaxitron receiver in weatherproof box for 24 VAC pan tilts zoom lens 24 VAC camera power and four ac cessory functions CX9024RX 12V Same as CX9024RX except supplied with 12 VDC camera power CX9024RXI Coaxitron receiver Same as CX9024RX except for indoor use CX9024RXI 12V Same as CX9024RXI except sup plied with 12 VDC camera power CX9115RX Coaxitron receiver in weatherproof box for 120 VAC pan tilt zoom lens 120 VAC camera power and four accessory functions CX9115RXI Same as CX9115RX except for in door use CX9224RX Same as CX9024RX except with 24 VAC power input CX9224RXI Same as CX92
11. tem 1 onto part A and connect both parts with the 3 Strip back the cable jacket approximately 1 1 4 screws provided inches 3 2 cm and separate the individual con ductors item 3 7 Connect the cable assembly to the unit and seat the connector by twisting the locking collar until it snaps into position threaded end of cable clamp Ny STRIP 1 8 STEPS 3 7 CRIMP INSULATION OUTSIDE JACKET OF CABLE ITEM 5 DETAIL 37 FRONT VIEW FRONT VIEW 37 PIN CONNECTOR 28 PIN CONNECTOR 2 pa 15 FRONT VIEW 16 PIN CONNECTOR THE MOST COMMONLY USED CONNECTOR PIN OUT CONFIG URATIONS ARE SHOWN HERE REFERENCE THE CONNECTOR I DRAWING APPLICABLE TO wi 12 YOUR SITUATION FRONT VIEW FRONT VIEW 14 PIN CONNECTOR 9 PIN CONNECTOR Figure 2 Mating Connector Assembly Diagram 4 Pelco Manual C916M 11 90 5 0 OPERATION The AUX2000 is operated by the Coaxitron or Wiretron controller 5 1 SYSTEM TEST Using the systems controller verify that the auxiliary devices function 6 0 TROUBLESHOOTING GUIDELINES In the event that the auxiliary equipment do not work retrace the wiring and verify correctness and check the fuse to make sure it did not open Correct all errors in wiring and replace the fuse if opened Retry to operate the auxiliary equipment If the auxiliary equipment does still not operate call Pelco s Technical Assistance Program TAP line at

Download Pdf Manuals

image

Related Search

Related Contents

QUAD VIDEO COULEUR 8 Entrées et Alarme  DeLOCK Express Card - 2 x FireWire A  216084 ES - Craigcat Costa Rica  Compaq XW6200 PC Desktop  Thomson One Analytics Excel Addin User Guide  Zeta Test Management  CycleavePCR®ウシ白血病ウイルス (BLV)検出キット  Audiovox MMD7HRPKG Owner's Manual  Senco PC1010 User's Manual  