1. Tighten all screws FRONT PLATE 8 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Cable Management C Cables may be routed using short cable ties I Use holes on bottom of lower mounting plate C with cable ties I to secure cables as shown below Cables may be routed using cable clip H Slip cable clip H onto bottom of center joint as shown in figure 7 1 and secure cables to cable clip using long cable tie N as shown in figure 7 2 Secure cables to bottom of wall plate using cable tie N as shown below 9 of 11 ISSUED 10 01 10 SHEET 095 9354 1 2009 Peerless Industries Inc All rights reserved All other brand and product names are trademarks or registered trademarks of their respective owners Roll Adjustment O Adapter plate may be rolled 5 Loosen four M6 nylock nuts half a turn grasp edges of display and roll screen to desired position as shown Retighten four M6 nylock nuts and place four snap caps J onto M6 nylock nuts CAUTION e Do not tighten joint screws Doing so may cause damage to screws greatly reducing its holding power JOINT SCREWS 0 9 Q 9 gJ 0 ae ee e 9 F 9 M6 NYLOCK NUTS 10 of 11 ISSUED 10 01 10 SHEET 095 9354 1 2009 Peerless Industries Inc All rights reserved All other brand and product names are trademarks or registered trademarks of their respective
2. h your product Parts List Description wall arm assembly upper mounting plate lower mounting plate wood screw concrete anchor security driver fastener cap cable clip short cable tie snap caps 8 32 x 1 4 flat head thread forming screw 1 4 20 x 1 2 hex head 520 2592 thread forming screw M4 x 16 mm phillips screw 520 2088 long cable tie 590 2168 046 4176 046 4177 046 4178 500 1090 590 0320 560 1133 046 4096 046 4137 560 2004 560 2029 520 2622 Re TOAMmM MVIADPSY RHRW OA AAA m M N 3 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Installation to Wood Stud Wall A WARNING e Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in Ib 9 N M Make sure that mounting screws are anchored into the center of the stud The use of an edge to edge stud finder is highly recommended Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs Installers are responsible to provide hardware for other types of mounting situations not evaluated by UL Use a stud finder to locate the edges of the studs Use of an edge to edge stud finder is highly recommended D Ba
3. ly 1 25 mm minimum from the side of the block Cinder block must meet ASTM C 90 specifications It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor e Installer must verify that the supporting surface will safely support the combined load of the equipment and all at tached hardware and components D NOTE Wall arm assembly A must be mounted to wall using inner mounting holes concrete surface E Make sure that wall arm assembly is level and use wall plate as a template to mark four mounting holes Top mounting slot will be X above the screen center as shown in figure 1 1 and chart 1 on page 4 Drill four 5 16 8 mm dia holes to a minimum depth of 2 5 64 mm Insert anchors E in holes flush with wall as shown Place wall arm assembly over anchors and secure with wood screws D Level then tighten all fasteners Insert eight fastener caps G into mounting holes NOTE Be sure arrow of label is pointing up when mounting wall arm assembly A to wall as shown in figure 1 1 A WARNING e Tighten screws so that wall plate is firmly attached but do not overtighten Overtightening can damage screws great
4. ly reducing their holding power Never tighten in excess of 80 in Ib 9 N M Always attach concrete anchors directly to load SOLID CONCRETE bearing concrete Never attach concrete anchors to concrete covered with plaster drywall or other finishing material If mounting to concrete surfaces covered with a finishing surface is unavoidable not evaluated by UL the finishing surface must be counterbored as shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 16 mm custom fasteners must be supplied by installer not evaluated 3 Tighten all fasteners CINDER BLOCK INCORRECT CUTAWAY VIEW 5 of 11 ISSUED 10 01 10 SHEET 095 9354 1 e Be sure to carry display upright from the top and bottom edges or damage to display may occur 2 Follow instruction manual included with display to remove display from stand Set display on a flat level surface Refer to display manufacturer s installation guide for recommended careful handling Remove two M4 chrome plated screws from Ultra Slim wall mount bar Save all screws Install eight standoff screws included with display into eight mounting holes on bottom of display M5 CHROME SCREWS STANDOFFS Asse
5. mble upper mounting plate B to lower mounting plate C using four 8 32 x 1 4 flat head thread forming screws K Use configuration as shown in figures 3 1 and 3 2 FOR 46 DISPLAYS FOR 55 DISPLAYS 6 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Q Install two 1 4 20 x 1 2 thread forming screws L into lower mounting plate C leaving 1 8 exposed thread as shown below Set control box into lower mount plate C and place assembly onto back of display Secure assembly to back of display by reinstalling two M4 chrome plated screws included with display into ultra slim wall mount bar four M4 black phillips screws included with display into lower mounting holes of control box and four M4 x 16 mm phillips screws M into upper mounting holes of control box ULTRA SLIM WALL MOUNT BAR DISPLAY __ CONTROL BOX 7 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Mounting Flat Panel Screen A WARNING e Tighten screws so screen brackets are firmly attached to screen Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw heads to become detached Tighten to 40 in Ib 4 5 N M maximum torque O Hook two 1 4 20 x 1 2 thread forming screws L onto top slots of front plate as shown in figure 6 1 Fasten two 1 4 20 x 1 2 thread forming screws L into bottom mounting holes as shown in figure 6 2
6. or consequential damages or damages arising from the theft of any product whether or not secured by a security device which may be included with the product This Limited Five Year Warranty is in lieu of all other warranties expressed or implied and is the sole remedy with respect to product defects No retailer dealer distributor installer or other person is authorized to modify or extend this warranty or impose any obligation on Peerless in connection with the sale of any product manufactured or supplied by Peerless This warranty gives specific legal rights and you may also have other rights provided by the national legislation of the country in which you purchased such product peer less www peerlessmounts com 2008 Peerless Industries Inc 11 of 11 ISSUED 10 01 10 SHEET 095 9354 1
7. owners LIMITED FIVE YEAR WARRANTY Peerless Industries Inc establishes a warranty period of five years for products manufactured or supplied by Peerless This period commences from the date of sale of the product to the original consumer but will in no case last for more than six years after the date of the product s manufacture During the warranty period such products will be free from defects in material and workmanship provided they are installed and used in compliance with the instructions established by Peerless Industries Inc Subject to applicable legal requirements during the warranty period Peerless will repair or replace or refund the purchase price of any such product which fails to conform with this warranty Any other warranties prescribed by the law which may apply with respect to such products also are limited in duration to the warranty period specified in this Limited Five Year Warranty This warranty does not cover damage caused by a service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless Industries Inc b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or warnings when installing using or storing the product or d misuse or accident in transit or otherwise including in cases of third party actions and force majeure In no event shall Peerless be liable for incidental
8. peer less Installation and Assembly Peerless Ultra Slim Articulating Mount for Samsung 46 and 55 C9000 LED displays Models SUAC9000 Max UL Load Capacity 75 Ib 34 kg 3215 W North Ave Melrose Park IL 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 10 01 10 SHEET 095 9354 1 NOTE Read entire instruction sheet before you start installation and assembly A WARNING Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet If you have any questions regarding any of the instructions or warnings for US customers please call Peerless customer care at 1 800 865 2112 for all international customers please contact your local distributor This product should only be installed by someone of good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Never exceed the Maximum UL Load Capacity See page one If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not over
9. sed on their edges draw a vertical line down each stud s center Center of screen mounting plate will be 2 5 offset from center of outer mounting slot as shown in figure 1 1 or will be 0 19 offset from center of inner mounting slot as shown in figure 1 2 Place wall arm A on wall as template level and mark the center of four mounting holes Top mounting slot will be X above the screen center as shown in figure 1 1 and chart 1 Drill four 5 32 dia holes to a minimum depth of 2 5 Secure wall arm A to wall with four wood screws D as shown in figure 1 2 NOTE Be sure arrow is pointing up when mounting wall arm A to wall as shown in figure 1 1 Level then tighten all fasteners Insert eight fastener caps G into wall plate mounting holes fig 1 1 ou ene ARROW 7 k fig i 0 19 5mm nae Te 5 eS E e SCREEN E eE EC amp J i MOUNTING PLATE a CENTER OF SCREEN 4 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Installation to Solid Concrete or Cinder Block A WARNING e When installing Peerless wall mounts on cinder block verify that you have a minimum of 1 3 8 35 mm of actual concrete thickness in the hole to be used for the concrete anchors Do not drill into mortar joints Be sure to mount in a solid part of the block general
10. tighten Overtightening can damage the items greatly reducing their holding power This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury This product was designed to be installed on the following wall construction only WALL CONSTRUCTION HARDWARE REQUIRED e Wood Stud Included Wood Beam Included Solid Concrete Included Cinder Block Included Brick Contact Qualified Professional Not evaluated by UL Other or unsure Contact Qualified Professional Not evaluated by UL Tools Needed for Assembly e stud finder edge to edge stud finder is recommended e phillips screwdriver e drill 5 16 8 mm bit for concrete and cinder block wall e 5 32 4 mm bit for wood stud wall e level Table of Conten Pants ENS basis caste ae cia eect oies vcatdind da ed aa V4 cya va sv gadis buena E een due dua nied ea aAa vaangaada vee E ated ea banddaa aed 3 Wall installation cisictieciie2 aides edited cbanigessiiaideas id vestagd ned vacmnads E ved vaoudgnbdedaeadiceadexteWidivedssiegsneesdiestesieMasiwecdes 4 5 Installing Adapter plates tO SCEC Mis iicscyecedscecseh char dea seesadecaesaen deeedseh ed eyandadaendaaceeetagvecd aa Ea aT a AEAEE EDA 6 Mounting Flat Panel Sereia annan anaa aa dence beac anda a lees oaaxateas gheadentanjucaacetieaad A aaa ebicaata ANNAA anes 8 2 of 11 ISSUED 10 01 10 SHEET 095 9354 1 Before you begin make sure all parts shown are included wit

Download Pdf Manuals

image

Related Search

Related Contents

OM Manual - Type-21/21a Ball Valve  Samsung GT-I8150B User Manual  

Copyright © All rights reserved.
Failed to retrieve file