Home

Patton electronic Serial G.SHDSL Bridge/Router 3087 User's Manual

image

Contents

1. When detaching the cables detach the end away from the device first Do not work on the system or connect or disconnect cables during periods of lightning activity 1 0 Power up the Bridge Router the proper application with respect to voltage current anticipated temperature flam mobility and mechanical serviceability The interconnecting cables shall be acceptable for external use and shall be rated for CAUTION Your ipRocketLink comes with one of the following power supply options Internal AC powger supply with detachable power cord External AC adapter with detachable power cord 1 1 Models with internal AC power supply 1 Insert the female end of the AC power cord into the internal power supply connector 2 Connect the male end of the power cord into an AC power outlet mains 100 240 V AC 1 2 Models with external AC adaptor 1 Connect the female plug of the AC power cord to the AC adaptor provided 2 Connect the barrel type connector of the AC adaptor to the barrel type power jack on the ipRocketLink 2 Model 3087 Quick Start Guide 3 Insert the male plug of the AC power cord into an AC power outlet mains 100 240 V AC 1 3 Power up indication The Power LED blinks as the ipRocketLink is powering up When the Power LED stops blinking and remains lit the ipRocketLink is ready for you to configure 2 0 Configure the IP address The ipRocketLink is shipped with a factory configured IP address to t
2. installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches C 3 EC Declaration of Conformity See section C 4 EG Konformit tserkl rung for German version Product Description ipRocketLink 3087 The products described above in the form as delivered are in conformity with the provisions of the following European Directive R amp TTE Directive 1999 5 EC Guidelines of the European Parliament and the Committee for the Harmonization of the mia Regu lations of the Member States concerning radio equipment and telecommunications terminal equip ment and the mutual recognition of their conformity The conformity to the above directive is indicated by the CE sign on the device C C The safety advice in the documentation accompanying the products shall be obeyed The signed Declaration of Conformity can be downloaded from www patton com certifications C 4 EG Konformit tserkl rung see section C 3 EC Declaration of Conformity for English version Produktbezeichnung ipRocketLink 3087 Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrac
3. user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the ground connections of the power utility telephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas Model 3087 Quick Start Guide 9 Copyright statement Copyright 2006 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors that may appear in this document Trademarks statement The term ipRocketLink is a trademark of Patton Electronics Company All othe
4. B PATTON ME Electronics To RocketLink Model 3087 rial G SHDSL Bridge Quick Start Guide G SHDSL Integrated Access Device Modes 7 OLE Lwan_ L Sync Seri Console 10 100 Ethernet Interface Port Document Number 03330U7 003 Rev A Sales Office 1 301 975 1000 Part Number 07M3087 QS Technical Support 1 301 975 1007 Revised June 29 2006 E mail support patton com WWW www patton com This devise contains no user serviceable parts The equipment shall be IN returned to Patton Electronics for repairs or repaired by qualified service personnel WARNING Voltage Do not open the case when the power cord is attached Line voltages are present within the power supply when the power cords are connected The mains outlet that is utilized to power the devise shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker For AC powered units ensure that the power cable used meets all applicable standards for the country in which it is to be installed and that it is connected to a wall outlet which has earth ground For units with an external power adapter the adapter shall be a listed Limited Power Source e Hazardous network voltages are present WAN ports regardless of whether power to the unit is ON or OFF To avoid electric shock use caution when near WAN ports
5. e configured as a DTE you must use a tail circuit cable You can purchase a tail circuit cable from a datacom supply vendor A tail circuit cable will cross over the necessary V 35 signals so that the two DCE interfaces can communicate Note The 3087 s X 21 interface is default configured as a DCE Changing the DTE DCE strap internally can set the configuration for DTE The 3087 s X 21 interface requires a cable with a male DB 15 connector 7 0 Additional Information Refer to the Model 3201 3086 amp 3087 Getting Started Guide located on the CD ROM shipped with your 3087 Bridge Router and available online at www patton com manuals For detailed information about e Installing configuring operating and troubleshooting e Warranty trademark amp compliance The CD ROM also includes many freeware and shareware tools including TFIP servers and Telnet clients A O Customer and Technical Support Toll Free VolP support call sip support patton com with a VolP SIP dient Online support www patton com E mail support support patton com answered within 1 business day Telephone support Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST 1300 to 2200 UTC GMT Alternate 41 0 31 985 25 55 Switzerland Monday Friday 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland 6 Model 3087 Quick Start Guide Appendix Key factory defaul
6. f your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications fo maintain uninterrupted service If trouble is experienced with this equipment for repair or warranty information please contact our company If the equipment is causing harm to the telephone network the telephone company may request that you discon nect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility commission public ser vice commission or corporation commission for information 3 6 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is con firmed by the registration number The abbreviation IC before the registration number signifies that registra tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment This Declaration of Conformity means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the
7. he Ethernet LAN port green outline The IP address is 192 168 200 10 24 In most cases you must change the address to be on the same subnet as your PC as described in the procedures below If you are not sure which IP address to use for your installa tion contact your network administrator 2 1 Connect a PC and log in 1 Using the included combination RS 232 Ethernet cable and DB9 RJ45 adaptor connect a PC s serial port to the ipRocketLink s Console port see figure 1 PC with terminal emulator 5 Serial port Connect to Console port Figure 1 Connecting the ipRocketLink console port to the PC s RS 232 serial port 2 Start a HyperTerminal or similar terminal emulation program session on the PC using the following set tings 9600 bps 8 data bits 1 stop bit no parity no flow control 3 Log into the ipRocketLink using the factory default login username and password Login superuser Password superuser Login successful 2 2 Modify the IP address 1 Display current IP interface settings for the ipRocketLink Ethernet LAN port Model 3087 Quick Start Guide 3 gt ip list interfaces lt enter gt IP Interfaces ID Name IP Address 2 Modify the IP address for the LAN port according to your network requirements gt ip set interface ipl ipaddress 10 10 10 5 255 255 255 0 Note The above IP address is only an example You must choose an IP address on the same subnet as your PC 3 Verify the new addre
8. hten Ausf hrung mit den Vorschriften fol gender Richtlinie berein R amp TTE 1999 5 EG Richtlinie des europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Funkanlagen und Telekommunikations Endeinrichtungen und die gegenseitige Anerkennung ihrer Konformitat Die Konformit t mit der oben erw hnten Richtlinie wird durch das CE Zeichen auf dem C C Die Sicherheitshinweise in der mitgelieferten Produktdokumentation sind zu beachten Ger t best tigt 8 Model 3087 Quick Start Guide Die unterzeichnete Konformit tserkl rung kann heruntergeladen werden von www patton com certifications 3 5 FCC Part 68 ACTA Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AAAEQ TXXXX If requested this number must be provided to the telephone company The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone com pany will notify the customer as soon as possible Also you will be advised o
9. r trademarks presented in this doc ument are the property of their respective owners Warranty Trademark amp Compliance Information For warranty trademark and compliance information refer to the Models 3201 3086 amp 3087 ipRocketlink Getting Started Guide located on the CD ROM that came with your 3087 or available online at www patton com Electrical and Electronic Equipment WEEE ensure that at end of life you separate this product from other waste and scrap and deliver to the WEEE collection system in emm your country for recycling T In accordance with the requirements of council directive 2002 96 EC on Waste of 10 Model 3087 Quick Start Guide
10. ss is correct and save it in system memory gt ip list interfaces lt enter gt gt system config save lt enter gt 3 0 Connect to the local IP network Now you can connect the ipRocketLink to your local IP network and complete the remaining configuration from your PC using a standard web browser Connect the ipRocketLink s Ethernet port green to the same Ethernet segment as your PC see figure 2 The front panel Ethernet Link LED should turn on If it does not turn on press the rear panel MDI X switch so that the Ethernet Link LED illuminates Ethernet port MDI X switch Figure 2 Connecting the ipRocketLink to the local IP network You can check the connection with the ping command For the example shown in you would ping 10 10 10 5 from a PC on the IP network 4 Model 3087 Quick Start Guide 4 0 Log onto the GUI web management page You will now access the web management graphical user interface GUI to configure the ipRocketLink using a standard web browser such as Netscape or Internet Explorer 1 At your PC open a web browser and enter the IP address you assigned to the ipRocketLink s Ethernet LAN port in step 2 of 2 2 Modify the IP address 2 Log into the web management home page using the username superuser and the password superuser See figure 3 Patton Electronics Company 3087 C G SHDSL Access Device Software Revision 2 6 6 Jun 2 2006 z E z e mio Stat
11. t parameters Key factory default parameters Parameter Defavlt Defavlt Default Ethernet port IP address 192 168 200 10 255 255 255 0 G SHDSL port 512 kbps Annex B Remote Serial port 512 kbps Internal clock mode WAN Static IP address type DHCP server Disabled DHCP relay Disabled Security Disabled SNTP client Unicast mode disabled Anycast mode disabled Broadcast mode enabled C 1 Compliance EMC Compliance FCC Part 15 Class A EN55022 Class A EN55024 Safety Compliance UL 609501 1 SA 22 2 NO 60950 1 IEC EN 60950 1 AS NZS 60950 1 PSTN Regulatory FCC Part 68 6 03 TBR 12 amp 13 El only AS MCIF S016 2001 only AS ACIF S043 2003 Model 3087 Quick Start Guide Compliance Information C 2 Radio and TV interference FCC Part 15 This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television recep tion This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in commercial installation However there is no guarantee that interference will not occur in a particular
12. us of 3087 C G SHDSL Access Device DSL Link Status In Progress DSL Link Rate Timeslot 8 Operational Mode Software Control Local IP Address 10 10 19 17 PP CPU Usage 1 NP CPU Usage 1 Up Time 00 0147s Current Time Wed 31 Dec 2003 190138 Figure 3 Model 3087 web management home page 5 0 Connect to the G SHDSL Port 1 Obtain single twisted pair cable with an RJ 11 plug connector at each end 2 Plug one end of the cable into the yellow RJ 11 socket labeled DSL on the ipRocketLink Integrated Access Device 3 Plug the other end of the cable into the RJ 11 wall socket that provides your G SHDSL service 4 When a DSL link is established the front panel WAN LINK LED will turn on 6 0 Connect the serial port Your ipRocketLink is equipped with one of the following serial WAN ports for connection to an NTU V35 M 34 08 25 Model 3087 RIC EUI X21 08 15 Model 3087 RID EUI T1 E1 RJ 48C and dual BNC Moel 3087 RIC EUI Model 3087 Quick Start Guide 5 Connect the serial cable to the ipRocketLink serial port as follows 1 Attach the male connector of the serial cable to the female serial connector on the 3087 2 Attach the other end of the cable to the serial connector on local device s serial port Note The 3087 s 1 35 interface is wired as a DCE No DTE configuration is possible If you are directly con necting the 3087 s V 35 interface to a third party equipment that cannot b