Home
Paradyne 4-Module User's Manual
Contents
1. 0 0 1 7 Connect Your Subscriber Lines NOTE No configuration is necessary for the interface module s installed in your IPD4000E to operate at default settings However if you wish to run your subscriber connections at settings other than the factory defaults Net to Net recommends configuring the interface module s prior to connection Refer to the installation instructions for your particular interface module model s at http www nettonet com support docs for configuration information The IPD4000E chassis supports ADSL IDSL SDSL and T1 E1 technologies Ensure that the subscriber lines you are connecting correspond with the technology of the interface module s installed in your IPD4000E 1 7 1 Identify the Appropriate RJ21 Connector s Subscriber lines must be connected according to the IPD4000E slot in which the corresponding interface module was installed Interface module slots 1 4 run from bottom to top the corresponding RJ21 ports are directly behind each slot on the back of the chassis 1 4 bottom to top Each interface module slot on the IPD4000E has two 2 corresponding RJ21 connectors on the back of the chassis the RJ21 connectors on the left A provide the subscriber connections for interface module ports 1 24 on most models and the RJ21 connectors on the right B provide the subscriber connections for interface module ports 25 48 on applicable models IPD4000E REAR VIEW B CL Interface Modul
2. NMS IPD4000E management capabilities depend upon the management module model installed in your chassis Once the management module has been initialized the interface modules installed in your IPD4000E may also be configured as desired Refer to the following documentation at http www nettonet com support docs for further information DOCUMENT CONTENTS management module installation instructions model specific uplink module installation instructions model specific interface module user guides model specific CLI Management User Guide NMS Management User Guide IPD4000E Installation Instructions 220 0000097 revOl module installation port pinouts parameter defaults parameter configuration options management system capabilities module installation port pinouts parameter defaults parameter configuration options module installation distance and bandwidth capabilities port pinouts parameter defaults parameter configuration options management module initialization instructions command user guide command definitions configuration options common to all management module models configuration options common to all interface module models management module initialization instructions screen by screen user guide parameter definitions configuration options common to all management module models configuration options common to all interface module models Page 14 of 17 3 0 ADDITIONAL I
3. in your IPD4000E you will need either a Media Interface Module MIM or an Uplink Interface Module UIM Only one uplink module is required for operational purposes however two uplink modules may be installed one in each port of the management module if redundancy is desired Refer to your management module and or uplink module installation instructions at http www nettonet com support docs for further information CAUTION If a blank plate is removed from a management module uplink port it must be replaced with an uplink module DO NOT OPERATE AN IPD4000E WITH A MANAGEMENT MODULE THAT HAS AN OPEN UPLINK PORT 1 3 2 Identify the Appropriate Slot for Installation The IPD4000E is a five slot chassis slots 1 4 are reserved for interface modules and Slot U1 is reserved for a management module The IPD4000E is factory shipped with slots 1 and U1 open and ready for module installation Management Module Slot IP DSL Access Multp kwar IPD4000E 0 0 0 0 0 WR NETTO NET TEHNOLOG ES OOM O00 1 3 3 Align the Management Module with the Slot Module Guides With the management module printed circuit board PCB facing UP and the management module model name and Net to Net logo on the RIGHT side of the module faceplate facing towards you align the left and right edges of the PCB with the U1 slot module guides on the IPD4000E IPD4000E Installation Instructions 220 0000097 rev01 Page 5 of 17 MANAGEME
4. of 17 Frequently Asked Questions Net to Net Enterprise MIBs Product Discontinuation Notices Product Documentation Visio Network Diagram Stencils 3 3 2 Technical Support Engineers If you are unable to locate the answers to your questions online please contact Net to Net Technologies Technical Support Department directly CUSTOMER LOCATION TECH SUPPORT EMAIL TECH SUPPORT PHONE Europe Middle East and Africa support emea nettonet com 44 0 1635 570953 United States support nettonet com 1 877 638 2638 all other locations support nettonet com 1 603 427 0600 3 4 Regulatory Compliance NEBS EMC SAFETY TELECOM 3 4 1 GR 63 CORE GR 1089 CORE FCC Part 15 CSA C108 8 EN55022 EN55024 UL 60950 1 Ist Edition UL Marking CSA 22 2 No 60950 1 03 EN60950 1 2001 CE Marking ACTA968 Part 68 ICCS 03 TBR1 2 TBR13 Site Selection Criteria In choosing a location for the installation of this product 3 4 2 Select a RESTRICTED ACCESS area where admittance is limited to trained and authorized service personnel Ensure that the internal temperature of a rack containing this equipment will not exceed the maximum recommended ambient temperature of 149 F 65 C Place the chassis such that connecting cables will not become a tripping hazard or pull loose from the chassis Do not block power supply vents or otherwise restrict airflow when installing this equipment Ensure that installation of this e
5. 003 du Canada 3 4 2 3 Europe This Class A product complies with European Norm EN55022 Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation Copyright 2004 Net to Net Technologies Inc The Net to Net Logo is a trademark of Net to Net Technologies Inc Worldwide Headquarters http www NetToNet com Net to Net Technologies 112 Corporate Drive Portsmouth NH 03801 USA 1 877 638 2638 support nettonet com IPD4000E Installation Instructions 220 0000097 revOl EMEA Headquarters Net to Net Technologies Victoria House 19 Park Way Newbury Berkshire RG14 1EE UK 44 0 1635 570950 support emea nettonet com Page 17 of 17
6. 12 Phillips Rack Screws 7 High x 17 Wide x 18 Deep 17 8 cm x 43 2 cm x 46 cm 28 Ibs 12 73 kg Co NA fo If there is visible damage do not attempt to connect the device Contact Customer Support customers in Europe the Middle East and Africa please call 44 0 1635 570953 or email support emea nettonet com customers in the United States please call 1 877 638 2638 or email support nettonet com All other customers please call 1 603 427 0600 or email support nettonet com 1 2 Select a Site for Installation NOTE The IPD4000E is designed for installation in a Restricted Access area where admittance is limited to trained and authorized service personel OPERATING REQUIREMENTS Operating Temperature 40 F to 149 F 40 C to 65 C Non Operating Temperature 40 F to 158 F 40 C to 70 C Humidity 5 to 95 non condensing Altitude 200ft to 16 500ft 60m to 5 000m 1 2 1 Tabletop Insert the four 4 provided rubber bumper screws into the mounting holes at the bottom four corners of the IPD4000E chassis for surface grip Position and secure all connecting cables such that they will not become a tripping hazard or pull loose from the chassis Ensure that the air supply vents around the top and bottom edges of the chassis are not blocked IPD4000E BOTTOM VIEW RUBBER BUMPER SCREW Side Top Front Rear IPD4000E Installation Instructions 220 0000097 rev0Ol Page 3 of 17 1 2 2
7. 5 1 1 Connect a Ground Wire to the IPD4000E Line up the 2 hole terminal lug of your ground wire with the two holes on the small unpainted section on the back of your chassis Secure the terminal lug to the chassis with two 10 32 screws IPD4000E REAR VIEW Ground Connection for 2 Hole Terminal Lug GROUND CONNECTION CLOSE UP O M T NN 1 5 1 2 Connect the Ground Wire to a Frame Ground Ground wire connection can vary from location to location although typically all equipment in a Central Office is grounded to a common copper bus 1 5 2 Select a Terminal Block Either terminal block on the back of the IPD4000E may be used to power the chassis only one terminal block is required for operational purposes The two terminal blocks on the IPD4000E are independent feeds Chassis power is supplied by only one terminal block at a time the second supply is merely back up Likewise the two terminal blocks do not load share Each terminal block must be supplied with adequate Amps to run the chassis independently power is not cumulative between the two IPD4000E Installation Instructions 220 0000097 rev0Ol Page 8 of 17 DC Terminal Blocks puo 1 5 3 Establish a Power Connection DC POWER SPECIFICATIONS 48V DC 10 Amps maximum Although actual power draw depends upon chassis configuration a fully loaded chassis averages around 6 Amps 1 5 3 1 Connect Your Positive Power Lead to the Terminal Block Usin
8. N NET TO Net TECHNOLOGIES Installation Instructions IPD4000E 4 Module IP DSLAM Internet Protocol Digital Subscriber Line Access Multiplexer NN NETTO NET TECHNOLOG ES 0 0 0 0 0 0000 OOO Copyright 2004 Net to Net Technologies Inc The Net to Net Logo is a trademark of Net to Net Technologies Inc Worldwide Headquarters http www NetToNet com EMEA Headquarters Net to Net Technologies Net to Net Technologies 112 Corporate Drive Victoria House 19 Park Way Portsmouth NH 03801 USA Newbury Berkshire RG14 1EE UK 1 877 638 2638 44 0 1635 570950 support nettonet com support emea nettonet com IPD4000E Installation Instructions 220 0000097 rev01 Page 1 of 17 Contents 1 0 INSTALLATION 1 1 Unpack and Inspect the Equipment 1 2 Select a Site for Installation 1 2 1 Tabletop 1 2 2 Rack 1 3 Install Your Management Module 1 3 1 Install an Uplink Module on the Management Module 1 3 2 Identify the Appropriate Slot for Installation 1 3 3 Align the Management Module with the Slot Module Guides 1 3 4 Slide the Management Module Firmly into the Chassis 1 4 Install Your Interface Module s 1 4 1 Select a Slot for Installation 1 4 2 Align the Interface Module with the Slot Module Guides 1 4 3 Slide the Interface Module Firmly into the Chassis 1 5 Power Up Your IPD4000E 1 5 1 Establish a Ground Connection 1 5 1 1 Connect a Ground Wire to the IPD4000E 1 5 1 2 Connect the Ground Wire t
9. NFORMATION 3 1 Fan Module The IPD4000E fan module is installed vertically to the right of the interface module slots It comes pre installed and should not be removed unless it is being replaced Fan functionality is indicated by a FAN LED on your management module all models NO illumination or solid GREEN illumination indicates all fans are currently functioning solid AMBER illumination indicates one or more of the four fans are no longer functioning IPD4000E FRONT VIEW vanan E Cm apie weseecees Peereeressessooeoseooooeooeoseooes 7 ai E seeeeseeee pporrerrrrerrerrrrcrrrrrirr tri ttt eee EZ e jeeeeee Peeeereresocoeoosoeoesososoeees gt NN NETTO NET m SNA IMO ASS MAINS SP AAHAANMBARSAMSASERS ST ET PENT o TEHNOLOG ES 0 0 0 0 0 OOM BOO Fan Module MODULE FANO OPWR Link Act Dplx UPLINK MANAGEMENT MODULE MULTIPLEXER T Fan LED CAUTION Do not operate the IPD4000E without a fan module or with a fan module that is not functioning properly 3 2 IPD4000E Interface Capacity 4 interface module slots 1 management module slot 8 RJ21 50 pin female Telco connectors 3 3 Technical Support 3 3 1 Net to Net Technologies Web Site The following information can be found at http www nettonet com support DSL Distance and Bandwidth Quick Reference Chart Firmware Downloads for applicable modules IPD4000E Installation Instructions 220 0000097 rev01 Page 15
10. NT MODULE file ___ gt im Ge Slot Module Guides IP DSL Access Multp hor PD400 Ww NETTO NET TEHNIOLOG ES OOM BOO 1 3 4 Slide the Management Module Firmly into the Chassis Tighten the fastening screws on the management module faceplate by turning them clockwise with a Phillips screwdriver Be careful NOT TO OVER TIGHTEN the screws Fastening Screws IP DSL Access Multp kwar IPD4000E NETTO NET TEHNOLOG E5 000 O BOO 0 0 0 0 0 1 4 Install Your Interface Module s Interface modules provide the subscriber connections for an IPD4000E up to four 4 interface modules may be installed in the IPD4000E slots 1 4 There are a variety of models available for purchase visit http www nettonet com products for a list of available products or contact your Net to Net sales representative for further information Any combination of interface module models may be installed in an IPD4000E as long as they are supported by the model type and version number of your management module refer to the Release Notes for your particular management module model at http www nettonet com support docs for compatibility information 1 4 1 Select a Slot for Installation Although the IPD4000E is factory shipped with Slot 1 open interface modules may be installed in any slot 1 4 IPD4000E Installation Instructions 220 0000097 rev0Ol Page 6 of 17 CAUTION If a blank plate is remove
11. Rack Using a Phillips Screwdriver attach the two 2 provided rack mount brackets to the sides of the IPD4000E with eight 8 of the ten 10 provided bracket screws There are seven position options for the rack brackets position them as best suited to the space available for your chassis on the rack being utilized RACK MOUNT BRACKET j gt 0 IPD4000E SIDE VIEW Mount the chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of eight 8 rack screws whichever size fits the rack being utilized IPD4000E FRONT VIEW WQ NETO NET TECHNOLOG E5 Check the rack for stability ensuring that installation of the IPD4000E has not caused the rack to become top heavy IPD4000E Installation Instructions 220 0000097 rev01 Page 4 of 17 1 3 Install Your Management Module A management module provides the functional control for Net to Net Technologies IPD4000E the IPD4000E cannot function without one There are several different models available for purchase refer to http www nettonet com products for further information or contact your Net to Net sales representative to discuss your options 1 3 1 Install an Uplink Module on the Management Module An uplink module provides the upstream network connection for Net to Net Technologies IPD4000E a management module cannot function without one Depending on the management module model that you plan to install
12. ck screw on the right side of the RJ21 connector frame on the chassis NOTE If you are using a 120 or 180 degree cable both the right and left sides of the cable connector should be screwed to the RJ21 connector frame on the chassis 1 7 5 Verify The Connection s The LK Link LED for each port being connected with a remote modem will illuminate solid or flashing green to indicate a connection has been established Link up time between interface modules and remote modems can vary from one to five minutes depending on the quality gauge and distance of the copper cable pair s being used Refer to individual interface module user guides at IPD4000E Installation Instructions 220 0000097 rev0Ol Page 13 of 17 http www nettonet com support docs for specific information such as connector pinouts parameter configurations and distance capabilities ADSL2 INVERSE MULTIPLEXER OPWR 1 8 Secure the Connecting Cables Soo000000 ALLII 0000000 rN OD Position all connecting cables such that they will not become a tripping hazard or pull loose from the chassis secure with cable ties or velcro straps 2 0 CONFIGURATION AND MANAGEMENT Although no configuration is necessary to run subscriber lines at Net to Net Technologies default settings all IPD4000E parameter settings are software selectable via Command Line Interface CLI Simple Network Management Protocol SNMP and or Net to Net s Network Management System
13. d from slot 2 4 it must be replaced with an interface module DO NOT OPERATE YOUR IPD4000E WITH AN EMPTY MODULE SLOT 1 4 2 Align the Interface Module with the Slot Module Guides With the interface module PCB facing UP and the interface module model name and Net to Net logo on the RIGHT side of the module faceplate facing towards you align the left and right edges of the PCB with the slot module guides of the chosen slot on the IPD4000E IP DSL Access Mu ttp kwar IPD4000E 0 0 0 0 0 I NETTO NET TECHNOLOG ES OOM 0000 Slot Module Guides n j y Toeoeeesoteeeoee ai o Seeeeeessesoosoooooos 52 3000800 A t tet INTERFACE MODULE 1 4 3 Slide the Interface Module Firmly into the Chassis Tighten the fastening screws on the interface module faceplate by turning them clockwise with a Phillips screwdriver Be careful NOT TO OVER TIGHTEN the Screws IP DSL Access Multp kwar IPD4000E vanan 0 0 0 0 0 PeCoooooesesesooooooooesesesoooooeoeeeeeeS gt Ww NETTO NET MINSI A PAHAAANNKAARRARARRKRR T ET PENT ss TEGHNOLOG ES Fastening Screws 1 5 Power Up Your IPD4000E CAUTION Turn your DC power source s OFF until you have completed connection of the IPD4000E as outlined below IPD4000E Installation Instructions 220 0000097 rev0Ol Page 7 of 17 1 5 1 Establish a Ground Connection CAUTION DO NOT operate your IPD40000E without a ground connection 1
14. e B connectors Interface Module A Connectors subscriber connections for ports 25 48 subscriber connections for ports 1 24 on applicable models on most models IPD4000E Installation Instructions 220 0000097 rev01 Page 11 of 17 EXCEPTION For the TIM1500 24 and EIM2000 24 interface modules the A connectors provide the subcriber connections for ports 1 12 and the B connectors provide the subscriber connections for ports 13 24 1 7 2 Detach the Velcro Strap Detach the Velcro Strap from the female RJ21 connector port lift the Velcro tab from the bottom and pull the strap upward to open leaving it looped under the right side of the connector frame FEMALE RJ21 CONNECTOR A FOR INTERFACE MODULE SLOT 3 1 7 3 Position the RJ21 Connector Slide the male RJ21 connector of your interface cable underneath the Velcro from the left and press it firmly into the female RJ21 connector port on the chassis MALE RJ21 CONNECTOR OF YOUR INTERFACE CABLE 1 7 4 Secure the RJ21 Connector Pull the Velcro strap upward making sure that it is snug against the connector then pull the strap back down such that the Velcro layers stick to one another across the top of the connector IPD4000E Installation Instructions 220 0000097 rev01 Page 12 of 17 Tuck the tab at the end of the strap down between the connector frames so that it is out of the way of other connections e Eao 4 Screw the right side of the RJ21 cable connector into the ja
15. g a Phillips Screwdriver remove the upper screw from the chosen terminal block labeled on the chassis Slide the ring terminal of your positive power lead around the shaft of the screw and re insert the screw into the same terminal from which it was removed T 4 Ring Qo POSITIVE Terminal POWER LEAD Positive Terminal DC POWER TERMINAL 1 5 3 2 Connect Your Negative Power Lead to the Terminal Block Remove the right hand screw labeled from the same terminal block Slide the ring terminal of your NEGATIVE lead around the shaft of the screw and re insert the screw into the same terminal from which it was removed IPD4000E Installation Instructions 220 0000097 rev0Ol Page 9 of 17 Negative Terminal DC POWER TERMINAL Ring NEGATIVE Terminal POWER LEAD CAUTION Be sure to attach THE POSITIVE LEAD TO THE POSITIVE TERMINAL and the NEGATIVE LEAD TO THE NEGATIVE TERMINAL as indicated on your IPD4000E terminal block labels 1 5 3 3 Connect Both Power Leads to a Fuse Panel The negative lead connects to a Batt Battery terminal and the positive lead connects to a Return terminal on your DC power supply CAUTION The power source s connected to the IPD4000E must be equipped with a disconnect device such as an On Off switch Otherwise an appropriately rated circuit breaker must be installed on each power circuit to be used In the case of an emergency hazardous voltages will not be re
16. moved from the IPD4000E until all power sources have been either turned off or disconnected from the chassis 1 5 4 Verify the Connection Turn your power source s on The PWR power LED on both the interface module and management module faceplates will illuminate solid green to indicate the modules are receiving power MANAGEMENT INTERFACE MODULE MODULE Power LED Power LED 4 4 a a w 4 wx o eoo PE ots aui g Xoo cano 5 lt 4 gt E 000 55 Qe 9 5 Hooded 5 x 5 1 6 Establish Your Uplink Connections NOTE No configuration is necessary for Uplink Interface Modules UIMs or Media Interface Modules MIMs as installed on the management module s in your IPD4000E to operate at default settings However if you wish to run your uplink connections at settings other than the UIM or MIM defaults Net to Net recommends configuring the UIM or MIM prior to connection For further connection and configuration information refer to the installation instructions of your particular UIM or MIM model at http www nettonet com support docs IPD4000E Installation Instructions 220 0000097 rev01 Page 10 of 17 Uplink Module IP DSL Access Mu ttp kwar IPD4000E CO O G00 O p Ritsssssressssseresssssetrecsseeeresseerrresesees 7 PPSSSSOSSSSSSSSSESSOSSSESSEOSSSOOEOSD be SSSSSSSSOSSSSSSSSSESSSSSOSSSSSESOOOD OS PE ABS LEST OP MAR ARRKARRAMRARRBA AT OTT TNT se NN NETTO NET TEGHNOLOG ES 0 0 0
17. o a Frame Ground 1 5 2 Select a Terminal Block 5 3 Establish a Power Connection 5 3 1 Connect Your Positive Power Lead to the Terminal Block 3 2 Connect Your Negative Power Lead to the Terminal Block 3 3 Connect Both Power Leads to a Fuse Panel 1 5 4 Verify the Connection 1 5 1 5 1 6 Establish Your Uplink Connections 1 7 Connect Your Subscriber Lines 1 7 1 Identify the Appropriate RJ21 Connector s 1 7 2 Detach the Velcro Strap 1 7 3 Position the RJ21 Connector 1 7 4 Secure the RJ21 Connector 1 7 5 Verify The Connection s 1 8 Secure the Connecting Cables 2 0 CONFIGURATION AND MANAGEMENT 3 0 ADDITIONAL INFORMATION 3 1 Fan Module 3 2 IPD4000E Interface Capacity 3 3 Technical Support 3 3 1 Net to Net Technologies Web Site 3 3 2 Technical Support Engineers 3 4 Regulatory Compliance 3 4 1 Site Selection Criteria 3 4 2 Class A Equipment 3 4 2 1 US Federal Communications Commission FCC 4 2 2 Industry Canada 3 3 4 2 3 Europe IPD4000E Installation Instructions 220 0000097 revOl Page 2 of 17 1 0 INSTALLATION CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge ESD precautions when handling this equipment 1 1 Unpack and Inspect the Equipment The following components should be included IPD4 E with 1 f 12 blank pl LEER a ea eo a CHASSIS SPECIFICATIONS Rack Mount Brackets either 19 or 23 as ordered 6 Phillips Bracket Screws 10 Phillips Rack Screws
18. quipment in a rack will not cause the rack to become top heavy or unstable Do not overload the electrical branch circuit of the power source for this equipment For tabletop use attach the enclosed rubber feet to the bottom of the chassis For rack installation attach the enclosed rack mount brackets to the sides of the chassis with the screws provided Class A Equipment 3 4 2 1 US Federal Communications Commission FCC Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These IPD4000E Installation Instructions 220 0000097 rev01 Page 16 of 17 limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment 3 4 2 2 Industry Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe A est conforme a la norme NMB
Download Pdf Manuals
Related Search
Related Contents
Samsung Galaxy S Plus User Manual informazioni di base sulla componente secondaria straumann 総合カタログ VOL.11 ダウンロード PDF 13.21MB applications - Mobil™ Industrial Lubricants SMART kapp iQ 55" capture board specifications Solar PV Consumer Guide Tripp Lite P010-012 User's Manual Internet : Celeste : Raccorder son entreprise à la Fibre Optique ロ歴ロアミロ TGPGE=R (p z。ーgzs Ver-L。ー Copyright © All rights reserved.