1. Restart the computer to allow loading the newly installed Network driver If the Trumpcard is a Multi Function adapter additional steps may be required to complete the full installation Refer to the Installation Guide accompanying the adapter for more details Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C User s Guide and Reference 3 13 Section Three Microsoft Workgroup Connection for DOS To install Workgroup Connection for DOS the Trumpcard driver diskette contains the required files to allow the installer to import an OEM diskette 1 Run SETUP from MSWGCN Workgroup Connection diskette 2 When prompted to select a Network card select Network card not shown on list below 3 When prompted for the location path of the OEM driver insert the Trumpcard driver diskette and enter ANWFWN31 4 Press ENTER to select the highlighted entry Ositech Trumpcard 5 Continue with the installation if prompted to re insert the OEM driver diskette be sure to enter the location path A WFW 31 as well The following are examples of changes made to the CONFIG SYS AUTOEXEC BAT and PROTOCOL INI CONFIG SYS DEVICE C DOS PROTMAN DOS I C DOS DEVICE C DOS WORKGRP SYS DEVICE C DOS OTCETH DOS AUTOEXEC BAT C DOS NET START PROTOCOL INI Network setup version 0x3110 netcard msSotceth nic 1 MSSOTCETHSNIC tra
2. Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C Novell Netware for DOS Depending on the version of Netware the installation of the Ositech Trumpcard ODI driver will be done automatically or must be done manually 3 16 Trumpcard Ethernet LAN Operation Netware NETX For Netware using NETX EXE the Trumpcard ODI driver must be installed manually by copying the Trumpcard ODI driver OTCETH COM to the directory containing the workstation software The Trumpcard ODI driver is located in the NETWARE DOS subdirectory on the Trumpcard driver diskette In order to configure the Trumpcard ODI driver a NET CFG file must be created refer to Appendix A for ODI keywords Netware VLM For Netware using VLM EXE the Trumpcard ODI driver can be installed automatically by using the Netware Client diskettes 1 Follow the instructions in the Workstation Basics and Installation for adapter installation using the Netware Client Install Any references to an ADAPTER OPTION DISKETTE means the Trumpcard driver diskette provided with the PC Card Proceed through steps 1 2 and 3 of the Netware Client Install making any changes as required At STEP 4 of the Netware Client Install press ENTER to install the Netware adapter driver When prompted to insert the adapter diskette follow the instructions and Remove the Netware Client Installation Diskette from the
3. Trumpcard Ethernet LAN User s Guide and Reference Copyright Information in this document is subject to change without notice Copyright 1995 1997 by Ositech Communications Inc Guelph Ontario Canada Ositech Communications Inc shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material Trumpcard is a trademark of Ositech Communications Inc P N 614006 001 Revision 3 0 How To Contact Us At Ositech Communications we make every effort to provide our customers with products that fit their needs and work well If you wish to communicate with technical support sales or any other department at Ositech please contact us in one or more of the following ways Ositech Communications Inc 679 Southgate Drive Guelph Ontario Canada N1G 4S2 Toll Free Telephone 1 888 OSITECH 1 888 674 8324 Local Telephone 519 836 8063 Facsimile 519 836 6156 24 HR Bulletin Board Service 519 836 1196 8 N 1 up to 33 6 KBPS Internet World Wide Web http www ositech com FTP ftp ositech com E Mail support ositech com sales ositech com Preface This guide provides Network software installation instructions for the Ositech Trumpcard Ethernet LAN PC Card The Trumpcard Ethernet LAN PC Card is a PCMCIA Type II PC Card that can connect to 10BaseT unshielded twisted pair or 10Base2
4. DRIVERNAME DXMEOS BINDINGS OSITECH_MOD OSITECH MOD DRIVERNAME OTCETHS Also in your AUTOEXEC BAT file the following line should have been added C LSP NETBIND Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C User s Guide and Reference 3 9 Section Three Microsoft LAN Manager To install Microsoft LAN Manager versions 2 0 2 1 and 2 2 the Trumpcard driver diskette contains the required files and directory structure to allow the LAN Manager installer to import an OEM disk 1 Begin installation of LAN Manager using SETUP from the LAN Manager Installation diskettes 2 When prompted to select the available Network adapter driver choose Other Driver at the bottom of the screen 3 When prompted insert the Trumpcard driver diskette 4 Select the OSITECH TRUMPCARD from the menu 5 Continue with installation until complete Your PROTOCOL INI file in your LANMAN directory should appear as follows PROTMAN MOD DRIVERNAME PROTMANS NETBEUI_NIF BINDINGS OSITECH_MOD OSITECH MOD DRIVERNAME OTCETHS In your CONFIG SYS the following lines should be present DEVICE C LANMAN PROTMAN DOS I C NLANMAN DEVICE C LANMAN OTCETH DOS In your AUTOEXEC BAT file the following line should appear C NLANMANNNETBIND Note Keyword s
5. To connect the Trumpcard to a 10Base2 Network connection using the Media Access Module follow these steps For the multi function Trumpcard the Ethernet connection is identified on the back of the PC Card insert the PCMCIA Ethernet Adapter connector on the Media Access Module into the one marked Ethernet Attach the T connector to the BNC connector on the Media Access Module align the notches in the T connector with the posts on the BNC connector push the connector in and twist about one quarter turn until it is seated properly Connect the coaxial cable s to the open ends of the T connector to form a single Network segment If at the end of the network segment attach a 50 ohm cable terminator to the unused T connector post The Trumpcard is keyed to go in one way only If you feel resistance before the it is fully inserted remove it turn it over and re insert it User s Guide and Reference 2 7 Section Two 2 8 Ethernet Adapter Connector BNC Connector Thin Ethernet Network Cable Media Access Module 10Base2 Network Connection Thin Coax Ethernet Segment A thin coax Ethernet cable segment is the length of cable between terminations The Trumpcard PC Card functions with 185 meter 607 foot with IEEE 10Base2 or 300 meter 984 foot using the extended length option cable segments The two above mentioned types of thin coax Ethernet cabling IEEE 10Base2 and extended length option are commonly used
6. thin coax Ethernet Networks The Ethernet LAN is available separately or combined with other functions This guide only describes the Ethernet LAN function of a single or multi function Trumpcard if your Trumpcard is multi function refer to the nstallation Guide accompanying the PC Card for more details Trumpcard Trumpcard LAN Trumpcard Ethernet LAN and Trumpcard Ethernet LAN PC Card will be used interchangeably throughout this manual All refer to the Ositech Trumpcard Ethernet LAN PC Card PCMCIA Card and PC Card will be used interchangeably throughout this manual As above both terms refer to the Ositech Trumpcard Ethernet LAN PC Card lii FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of t
7. Network Interface Card Driver enter OTCETH SYS 3 The installation utility will confirm if this is a third party NIC driver enter YES 4 When prompted to enter the file to install enter A NNETWARENOS2NOTCETH SYS Insert the Trumpcard driver diskette into Drive A 5 Continue with the Netware requester installation the final step will be to configure the NET CFG file See Appendix A for ODI keywords End of Installation Trumpcard Ethernet LAN Operation Loading the OS 2 ODI Driver Note Note The OS 2 ODI driver OTCETH SYS for the Trumpcard is an OS 2 device driver it must always be loaded afterthe LSL Link Support Layer module and before the IPX IPX Protocol Stack Below is an example of a possible CONFIG SYS file which allows the loading of necessary modules to establish a link from an OS 2 Workstation to a Netware Server REM Netware Requester statements BEGIN DEVICE C NETWARE LSL SYS RUN C NETWARE DDAEMON EXE D D EVICE C NETWARE OTCETH SYS EVICE C NNETWARENIPX SYS rem DEVICE C NNETWARENSPX SYS rem RUN 2C NNETWARENSPDAEMON EXE rem DEVICE C NETWARE NMPIPE SYS rem DEVICE C NETWARE NPSERVER SYS rem RUN C NNETWARENNPDAEMON EXE NP_COMPUTERNAME DEVICE C NETWARE NWREQ SYS IFS C NETWARE NWIFS IFS RUN C NETWARENNWDAEMON EXE rem DEVICE C NETWARE NETBIOS SYS rem RUN C NETWARE NBDAEMON EXE rem DEVICE C NETWARE VIPX SY
8. Pair Networks ccceescceesseteeeeeesteeeeeeees 2 3 Interface Cabling and PinOut cecceeeeessceeeseeeeeeeeeeeeeseeeeeeeeaeeeeeeeeseeeeaeees 2 5 elle e EE 2 6 Twisted Pair Ethernet Network Characteristics cc cccccessceeeeesteeeeeeeees 2 6 Connecting to 10Base2 Thin Ethernet Networks eese 2 7 Thin Coax Ethernet Segment nennen 2 8 Thin Ethernet Network Characteristics sssssssssssseeeene 2 10 Media Access Module LED Indicators AA 2 11 Section Three Operation 3 1 Socket Services and Card Services cccccsccccccccessssseeeeeeeeeceesesteeeeeeeeeeeeseeaaes 3 2 Multi Function Configuration nennen 3 2 Network Software Installation eeeeeeeeeeee nn 3 3 Banyan VINES E 3 3 DEC PAT EE 3 4 FTE Software Lapnatechy eeneg EE 3 5 IBM LAN Semer coetui asumir ti oos aaia ie dose 3 6 IBM LAN Support Prograf u csciecsceeccseceseesccneetiessceeesenenduttesceeedeestuneaeccbesers 3 8 Microsoft LAN Menager iren recen traen rte iuncto e code evan a 3 10 Microsoft Windows for Workoroupe me 3 11 Microsoft Windows NT 3 5 ccccccccccsssesseceeeeeesneeeseceeeceesaeeseceeeeeesuenseseneneneaes 3 13 Microsoft Workgroup Connection for DOS 1 0 0 2 eeceeeeeeeeeeeeteeeeeeeeteeeeeeeeeee 3 13 leie IEEE 3 15 Novell Netware for DOS 3 16 Novell Netware for OS 3 17 Novell Unixware DEPI Driver nesciens ecu ite en dag extr Pda ca nna aai tat 3
9. Pick one type of cabling and consistently obey the protocol for that type throughout your network If you mix the rules for example using two repeater links permitted by 10Base2 with the 100 nodes per segment permitted under the extended length option your network may have an excessive number of errors or may not operate at all If your network uses standard 185 meter cable segments all thin Ethernet cable segments in the network can be up to 185 meters long Five standard length cable segments may be connected in line using commercially available repeaters The total network span with five standard length segments is 925 meters 3 035 feet No more than four repeaters can be on the signal path from one node to any other node The standard 185 meter segment length is recommended because it allows you to use common thin coax Ethernet components which conform to the IEEE standard If your network is using extended length 300 meter cable segments all thin coax Ethernet cable segments in the network can be a maximum of 300 meters long Three 300 meter cable segments may be connected in line using repeaters The total network span with three extended length segments is 900 meters 2 953 feet No more than two repeaters can be in the signal path from one node to any other node Trumpcard Ethernet LAN Hardware Installation If you are using extended length segments all repeaters and transceivers must be designed for 300 meter operation In
10. activity is detected by the Media Access Module The Activity LED can be used as a simple method of determining if the Media Access Module is exchanging data with the network Link LED GREEN The Link LED lights whenever a twisted pair connection between the Media Access Module and the 10BaseT concentrator has been made The Link LED is not used for 10Base2 thin coax connections If the Link LED is not lit this would indicate that a connection between the Media Access Module and the 10BaseT concentrator has not been detected Verify the wiring and make sure that a Trumpcard network driver has been loaded User s Guide and Reference 2 11 Section Two Trumpcard EthernetLAN Operation Section Three Operation User s Guide and Reference 3 1 Section Three Socket Services and Card Services Your computer having Personal Computer Memory Card International Association PCMCIA support allows you to insert credit card sized devices called PC Cards The PCMCIA standard defines both a hardware and software standard The software standard identifies two specifications which are called Socket Services and Card Services Socket Services provides lowest level support by providing a common interface to varying types of PCMCIA adapter hardware Card Services provides support for PCMCIA aware device drivers known as clients and is responsible for coordinating access to the PC Cards and allocating system resources among client drivers
11. on the Trumpcard is currently active The IRQ or PORT keywords are used and either the IRQ or PORT requested is unavailable Trumpcard Ethernet LAN Appendices To correct this error make sure that the requested resources i e IRQ PORT or EXCLUSIVE used do not conflict with other resources currently in use PCMCIA adapter not found The network driver has been unable to detect a PCMCIA adapter A valid PCMCIA adapter must be INTEL or Databook compatible If your computer does have a PCMCIA adapter but it is not recognized by the network driver use the Socket Services software provided by the computer manufacturer to remedy this situation Failed to register with Card Services This error only occurs if Card Services is detected The network driver was unable to register a valid configuration with Card Services Registration could be disallowed if the IRQ or PORT keyword is used and either the IRQ or PORT requested is unavailable To correct this error make sure that the requested resources i e IRQ or PORT do not conflict with other resources currently in use Failed to obtain IRQ Failed to release IRQ Failed to obtain I O Port Failed to release I O Port Failed to obtain Configuration Failed to release Configuration These errors are related to the obtaining and releasing of resources needed to operate the network For errors related to obtaining resources make sure that the I O Port and IRQ requested is available f
12. protocol manager DRIVERNAME PROTMANS stack DRIVERNAME STACKS BINDINGS OSITECH_NIF ositech_nif DRIVERNAI E OTCETHS EDIA BAS EXCLUSIVE ISLINK SOCKET 1 User s Guide and Reference ET EM 0xD0000 D INTERRUPT 5 IOBASE 0x300 NETADDRESS 000079821660 AXTRANSMITS 24 Appendices Section Four APPENDIX C MESSAGES WARNING MESSAGES Warning messages will result in the network driver being loaded into memory provided no error messages were reported The driver will use pre defined defaults when warnings are issued the user will be informed of these defaults Improper operation may result when defaults are used MEDIA parameter is invalid valid values are 100BASET 10BASE2 or AUTO default AUTO SOCKET parameter is invalid valid values are 1 or 2 default AUTO MEM parameter is invalid valid range is any hexademical address default C8000 ERROR MESSAGES Error messages will result in the network driver not being loaded into memory Correct the error condition and reload the network driver Failed to register with Multi Function Manager This error only occurs if the Multi Function Manager is being used The network driver is unable to register a valid configuration with the Multi Function Manager Registration could be disallowed for any one of these reasons The EXCLUSIVE keyword was used and the other function
13. 19 SCC HN P SM EDITT E 3 20 Section Four Appendices 4 1 APPENDIX A ODI Revwors nennen eren 4 2 NET CEG EXample deeg 4 5 APPENDIX B NDIS Keywords oorsit ireren easain in 4 6 PROTOGOL NI EXaimiple eese ra cei ona reece 4 8 APPENDIX C MESGGAGES senes 4 9 WARNING MESSAGES sese nnne 4 9 ERROR MESSAGES ener ener 4 9 ODI Specific Error Messages REENEN 4 12 NDIS Specific Error Messages A 4 12 vi Introduction Section One Introduction Note Congratulations on your choice of an Ositech Trumpcard Ethernet LAN PC Card We believe you will find it a superior quality product that will meet or exceed your Networking needs The Trumpcard Ethernet LAN PC Card is a convenient dual media credit card sized adapter that provides an interface between a PCMCIA capable computer and an Ethernet Network Direct connection to a 10BaseT Network is possible via a 10BaseT PCMCIA cable only For 10Base2 connections a Media Access Module is required Two styles of connectors are provided on the Media Access Module enabling connection to the Network using RJ 45 to connect to 10BaseT or BNC to connect to 10Base2 This manual is intended as a supplement to the manual s supplied with your Network system software Use that document as the primary reference source for information about your Network Software installation instructions are given in Section Two for connecting to Banyan VINES DEC PATHWORKS FT
14. NMSGDD OS2 I C NIBMCOM EVICE C IBMCOM PROTMAN OS2 I C IBMCOM D D RUN C IBMCOM PROTOCOL NETBIND EXE RUN C NIBMCOMNLANMSGEX EXE DEVICE C IBMCOM PROTOCOL BEUI OS2 DEVICE C IBMCOM PROTOCOL NETBIOS OS2 DEVICE C IBMCOM PROTOCOL LANDD OS2 DEVICE C IBMCOM PROTOCOL LANDLLDD OS2 DEVICE C IBMCOM MACS OTCETH OS2 RUN C IBMCOM PROTOCOL LANDLL EXE User s Guide and Reference 3 7 Section Three PROTOCOL INI PROT_MAN DRIVERNAME PROTMANS IBMLXCFG OSTETH nif OTCETH nif LANDD_nif LANDD nif NETBEUI nif NETBEUI nif LANDD nif DRIVERNAME LANDDS BINDINGS OTCETH_nif ETHERAND TYPE I NETBEUI nif DRIVERNAME NETBEUIS BINDINGS OTCETH_nif ETHERAND TYPE I OTCETH nif DRIVERNAME OTCETHS Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C IBM LAN Support Program When installing the IBM Local Area Network Support Program LSP version 1 3 or later you may use the OEM Network adapter driver import capability for the Ositech Trumpcard NDIS device driver Follow the instructions in the LSP manual User s Guide for adapter installation using the nstallation A
15. Ositech s Trumpcard software is PCMCIA aware and will work with most Socket Services and Card Services available that conform to the PCMCIA 2 x standard The Trumpcard software will operate as a client driver when used with Card Services and can coexist with other client drivers i e Super Clients Flash ATA When operating with Card and Socket Services the Trumpcard software will support hot removal and insertion of the PC Card If Card Services is not detected by the Trumpcard software but Socket Services is then the software will operate with Socket Services only Support for Socket Services is provided to allow for differing types of PCMCIA hardware to be used by the Trumpcard software but the full range of features will not be supported mainly hot removal insertion It is also possible to use the Trumpcard software without Card Services or Socket Services but as with only using Socket Services the full range of features will not be supported If your computer did not come equipped with Card and Socket Services contact your computer manufacturer or dealer for more details Multi Function Configuration If the Trumpcard you are using provides other functions in addition to Ethernet networking please refer to the nstallation Manual accompanying the Trumpcard Details on how to enable and use all the functions provided on the Trumpcard will be discussed in that manual Trumpcard Ethernet LAN Operation Network Soft
16. P Software LanWatch IBMLAN Server IBM LAN Support Program Microsoft LAN Manager Microsoft Windows for Workgroups Microsoft Windows NT Microsoft Workgroup connection for DOS NDIS Generic Novell Netware for DOS Novell Netware for OS 2 Novell Unixware SCO Unix User s Guide and Reference 1 1 Section One 1 2 Trumpcard Ethernet LAN Hardware Installation Section Two Hardware Installation Unpack the Trumpcard Ethernet LAN hardware and follow the steps listed below to install it on your computer Instructions are included for both 10BaseT twisted pair and 10Base2 thin coax Ethernet Network operations Preparing for Installation To install the Trumpcard you require the accompanying diskettes and the following items A computer equipped with a PCMCIA Release 2 0 Type Il PC Card slot e PCMCIA Card and Socket Services Version 2 x or higher installed This is optional since the Trumpcard can be operated without Card and Socket Services A Network operating system that is supported by the Trumpcard Network drivers For 10Base2 thin coax Networks a coaxial T connector and a terminator if at the end of the coaxial segment For 10BaseT twisted pair Networks a twisted pair Network cable terminated with an RJ 45 connector when using the Media Access Module for 10BaseT connections User s Guide and Reference 2 1 Section Two Installing the Trumpcard Ethernet LAN The Trumpcard Ethernet LAN can
17. Pinout The direct connect 10BaseT cable provided with the Trumpcard is wired for direct connection to an Ethernet 10BaseT Concentrator If the premises wiring scheme you are using does not match this wiring scheme then contact Ositech for assistance on how to make a 10BaseT Network connection in your environment ND co JO Om P GO A 10BaseT Pinout User s Guide and Reference 2 5 Section Two Concentrators The Trumpcard when used with 10BaseT Twisted pair cable must always connect to a concentrator This results in a star wired Network with the concentrator at the centre of the star The Trumpcard is compatible with 10BaseT concentrators from a variety of vendors Twisted Pair Network Characteristics Standard IEEE 802 3 10BaseT Data Rate 10 Mbits per second Maximum length of connecting 100m 328 nodes per network Maximum number of computer 1024 nodes per network Twisted pair cable Category 3 10 mbps or Category 4 16 mbps or Category 5 100 mbps that meet the requirements of EIA TIA 568 and EIA TIA TSB 36 Trumpcard Ethernet LAN Hardware Installation Connecting to 10Base2 Thin Ethernet Networks Note The Trumpcard can only be connected to a 10Base2 Network by using the Media Access Module The following items are required to interconnect the Trumpcard to a 10Base2 thin coax Ethernet Network A BNC coaxial T connector Coaxial cable s and a 50 ohm cable terminator if required
18. S rem DEVICE C NETWARE VSHELL SYS REM Netware Requester statements END If your Ethernet frame type is NOT 802 2 you must use the NET CFG file to supply the appropriate frame type The OTCETH driver will default to 802 2 in accordance with Novell s specifications Keyword specifications associated with the ODI driver are explained in Appendix A Error Messages in Appendix C Novell Unixware DLPI Driver The Trumpcard DLPI Driver is an AT amp T Data Link Provider Interface DLPI compliant loadable STREAMS driver for UNIX System V Release 4 2 The driver has a built in enabler for Intel Databook and compatible PCMCIA equipped computers With this driver installed networking functions will be available under Unixware User s Guide and Reference 3 19 Section Three Note Note The Trumpcard DLPI driver requires that the Trumpcard PC Card be inserted prior to the driver being loaded If no Trumpcard is found the driver will not be loaded and networking functions will NOT be available When the driver has successfully loaded unpredictable results will occur if the Trumpcard is now removed from the PCMCIA slot The Trumpcard DLPI Driver DOES NOT support hot insertion and removal To install t
19. UTO Accepted Values BASE2 BASET AUTO Note If you are using the dual media Trumpcard network PC Card setting this keyword to Base2 or BaseT will force that media type connection only By default the driver will try to determine which media is connected by first trying BaseT and then Base2 MEMz memory location Description Maps to 4K host memory location Default 0xC800 Note When Card Services is not present the only scenario in which this keyword applies the Trumpcard driver will require the 4K memory window in order to determine the Trumpcard s presence If running a memory manager such as EMM386 or QEMM make sure to exclude the memory range used i e X C800 C8FF EXCLUSIVE Description Put Trumpcard in LAN only mode Default Multi mode Note If the Trumpcard is a multi function card specifying this keyword will disable the other function as long as the network driver is loaded If the other function is already in use the driver will report an error DISLINK Description Disable link poll mode Default Enable link Note This keyword is used to disable the Link Test Function on 10BaseT network connection only User s Guide and Reference 4 5 Section Four INTERRUPT lt interruptlevel gt Description Set the interrupt level Default 5 or AUTO Accepted values Any valid interrupt value excluding 0 1 2 6 8 and 13 Note If this keyword exists the driver will return an error if unable to operate us
20. addition all LAN adapters must be configured to operate with the extended segment length Note You cannot use Ethernet adapters to extend 185 meter segments to 300 meter segments unless all LAN adapters and repeaters in the network are capable of operation on the extended segment length User s Guide and Reference 2 9 Section Two Thin Ethernet Network Characteristics Characteristics Data Rate Segment Length Standard Length Segment Extended Length Segment IEEE 802 3 10Base2 10 Mbits per second 300m 984 IEEE 802 3 10Base2 10 Mbits per second 185m 607 Maximum number of segments between nodes Maximum number of repeaters between nodes 3 coax plus 2 repeater links 4 when using 2 repeater links 3 coax no repeater links 900m 2953 1024 0 5m 1 64 20 RG58 A U or C U 50 ohm Network Span 925m 3035 Maximum number 30 of nodes per segment Maximum number of nodes per network Minimum space between nodes 0 5m 1 64 20 RG58 A U or C U 50 ohm Cable type Trumpcard Ethernet LAN Hardware Installation Media Access Module LED Indicators The Media Access Module has two LED indicators used to provide a visual indication of the state of the network link The LED indicators will only be operational once the Trumpcard network driver has been loaded or during Diagnostic testing Activity LED RED The Activity LED will flash whenever any network
21. be inserted into a computer whether the power is ON or OFF Follow these steps Orient the Trumpcard so that the 68 pin connector is next to the PCMCIA slot of the computer Insert the Trumpcard into the slot until it is firmly seated Note These are general installation instructions that apply to most computers Please refer to the manual accompanying your computer for any additional instructions on installing PC Card adapters Note The Trumpcard is keyed to go in one way only If you feel resistance before it is fully inserted remove it turn it over and re insert it Top Left Ethernet Installing the Trumpcard 2 2 Trumpcard Ethernet LAN Hardware Installation Connecting to 10BaseT Twisted Pair Networks The Trumpcard Ethernet LAN can be connected to a 10BaseT Network in one of two ways directly connected through a cable attached to the Trumpcard if you have the 10BaseT version or via the Media Access Module if you need to connect with 10Base2 cabling Connecting directly to the Trumpcard the cable supplied has a male RJ 45 connector at one end that can be attached to an input port of a 10BaseT compatible concentrator the external Media Access Module is not required All the necessary interface is provided within the Trumpcard To direct connect the Trumpcard to a 10BaseT Network connection follow these steps Locate the twisted pair cable that has a male RJ 45 connector at one end and a PCMCIA Ethe
22. create the Ositech Trumpcard DLPI Driver install diskette and to install the driver you need only execute the INSTALL shell script that you have copied to the tmp directory You can only execute the INSTALL script after you have become the root user It is highly recommended that you run the shell script as root because the installation process will require that you relink the kernel Trumpcard Ethernet LAN Operation su enter the root password at the Password prompt cd tmp pkgadd d diskettel Then simply follow the instructions provided by the installation script to complete the installation of the driver SCO UNIX LLI Driver Note The Trumpcard LLI Driver is a Network driver and enabler for Intel Databook and compatible PCMCIA equipped computers With this driver installed networking functions will be available under SCO UNIX The Trumpcard LLI driver requires that the Trumpcard PC Card be inserted prior to the driver being loaded If no Trumpcard is found the driver will not be loaded and networking functions will NOT be available When the driver has successfully loaded unpredictable results will occur if the Trumpcard is now removed from the PCMCIA slot The Trumpcard LLI Driver DOES NOT support hot insertion and removal To install the Trumpcard LLI driver you need to create an Ositech LLI Driver Disk using the INSTALL shell script from the DOS formatted Network Drivers distribution diskette provided with t
23. drive Insert the Trumpcard driver diskette Press ENTER Follow the instructions to select the Trumpcard ODI driver and configure the driver as required At STEP 5 press ENTER to install the Client software on the workstation End of Installation User s Guide and Reference 3 17 Section Three Loading the DOS ODI Driver Note Note The DOS ODI driver OTCETH COM for the Trumpcard PC Card is an executable DOS TSR Terminate and Stay Resident program It must be loaded always after the LSL Link Support Layer module and before the IPXODI IPX Stack Protocol An example of a possible AUTOEXEC BAT file allowing the loading of necessary modules to establish a link from a DOS Workstation to a Netware Server is LSL OTCETH IPXODI NETX or VLM If your Ethernet frame type is NOT 802 2 you must use the NET CFG file to supply the appropriate frame type The OTCETH ariver will default to 802 2 in accordance with Novell s specifications Keyword specifications associated with the ODI drivers are explained in Appendix A Error Messages in Appendix C Novell Netware for OS 2 When installing Netware for OS 2 you may use the automatic installation for the Ositech Trumpcard ODI device driver Netware 3 x and 4 x 1 Follow the instructions in the Netware Requester for OS 2 manual on how to Install and Configure the Novell Netware OS 2 Requester 2 During installation of the requester when prompted for the
24. e MD C NNDIS 2 Copy the files OTCETH DOS and PROTOCOL INI from the FTP directory on Trumpcard driver diskette to NDIS directory on C drive i e COPY A FTP OTCETH DOS C NDIS 3 Run LANWatch install program i e INSTALL User s Guide and Reference 3 5 Section Three Note 4 When prompted for Packet driver or NDIS driver select NDIS driver 5 When asked do you have a PROTOCOL INI file answer YES 6 When prompted for path to PROTOCOL INI file type C NDIS 7 When asked which driver does LanWatch bind to type OSITECH_NIF 8 When prompted for full path and filename of NDIS driver type C NDIS OTCETH DOS Continue with installation The following are examples of the CONFIG SYS AUTOEXEC BAT and PROTOCOL INI file modifications after installing LanWatch CONFIG SYS DEVICE C LW PROTMAN DOS I C NNDIS DEVICE C LW FTPSOFT DOS DEVICE C NDIS OTCETH DOS AUTOEXEC BAT C NLWNNETBIND COM PROTOCOL INI OSITECH NIF DRIVERNAME OTCETH LANWATCH DRIVERNAME PSOFTS BINDINGS OSITECH_NIF Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C IBM LAN Server When installing IBM LAN Server 3 0 or 4 0 you may use the OEM Network adapter driver import capability for the Ositech Trumpcard NDIS device driver For a DOS workstation follow the in
25. ers The keywords must be in the NET CFG file under the line LINK DRIVER OTCETH and must be indented in by at least one space If the keyword is not present the default value shown will be assumed FRAME lt frame type gt Description Frame type used by the driver Default Ethernet_802 2 Accepted values Ethernet 802 3 Ethernet Il Ethernet SNAP Ethernet 802 2 Note Make sure the frame type matches that used by the server MEDIA media type Description Media type selected by the driver Default AUTO Accepted Values 10BASE2 or BASE2 10BASET or BASET AUTO Note If you are using the dual media Trumpcard network PC Card setting this keyword to 10Base2 or 10BaseT will force that media type connection only By default the driver will try to determine which media is connected by first trying 10BaseT and then 10Base2 EXCLUSIVE Description Put Trumpcard in LAN only mode Default Multi mode Note If the Trumpcard is a multi function card specifying this keyword will disable the other function as long as the network driver is loaded If the other function is already in use the driver will report an error DISLINK Description Disable link poll mode Default Enable link 4 2 Trumpcard Ethernet LAN Appendices Note This keyword is used to disable the Link Test Function on a 10BaseT network connection only INT interrupt level gt Description Set the interrupt level Default 5 or AUTO Accepted values Any
26. he Trumpcard DLPI driver you need to create an Ositech DLPI Driver Disk using the INSTALL shell script from the DOS formatted Network Drivers distribution diskette provided with the PC Card The first step is to copy the INSTALL shell script to the Unixware tmp directory from the distribution diskette UNIX UW directory The installation process performed by the INSTALL shell script consists of two basic steps 1 Creating the Ositech DLPI Driver Disk from the compressed disk image extracted from the osi uw tar archive 2 Second installing the driver from the Ositech DLPI Driver Disk using the pkgadd utility If the Trumpcard is a Multi Function PC Card additional steps may be required to complete the full installation Refer to the Installation Guide accompanying the PC Card for more details In order to successfully complete the installation process the following is required One blank 3 5 inch high density 1 44MB diskette labelled Ositech Trumpcard DLPI Driver Disk IO ports and IRQs that you wish to assign to the LAN function The LAN will need 32 ports default of 0x300 0x31f A 4K memory window that you can assign to the driver in the range of 0xc0000 and 0xf0000 The default is 0xc8000 Ability to use pkgadd to install and configure the Network software 2MB of free disk space for the various temporary files that are created during the install process on the file system containing the tmp directory To
27. he adapter The first step is to copy the INSTALL shell script to the UNIX tmp directory from the distribution diskette UNIX SCO directory If you do not have the DOS file system support installed on your UNIX system then you must also copy the osi sco tar file to the tmp directory If you wish to install the DOS file system support then execute the UNIX command mkdev dos as the root user and reboot your machine The installation process performed by the INSTALL shell script consists of three basic steps 1 Creating the Ositech LLI Driver Disk from the compressed disk image extracted from the osi sco tar archive 2 Second installing the driver from the Ositech LLI Driver Disk using the custom utility 3 Binding the Network software to the Trumpcard driver using netconfig If the Trumpcard is a Multi Function PC Card additional steps may be required to complete the full installation Refer to the Installation Guide accompanying the PC Card for more details In order to successfully complete the installation process the following is required User s Guide and Reference 3 21 Section Three Note One blank 3 5 inch high density 1 44MB diskette libelled Ositech Trumpcard LLI Driver Disk IO port and IRQ that you wish to assign to the LAN function You can use hwconfig to see what devices are currently configured into your UNIX system The LAN will need 32 ports default of 0x300 0x31f A 4K memory window
28. he following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Ositech Communications Inc may void the user s authority to operate this equipment Operating Conditions This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation Canadian Electromagnetic Compatibility Advisory This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Conseil sur la compatibilit des Electromagn tiques pour le Canada Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Contents Section One Introduction 1 1 Section Two Hardware Installation 2 1 Preparing for Installation eerte ce cett ree tne nete et Rp nnne 2 1 Installing the Trumpeard LAN BEE 2 2 Connecting to 10BaseT Twisted
29. id Any references to an ADAPTER OPTION DISKETTE means the Trumpcard Driver diskette provided 1 At the Environment Information screen answer YES for the question Do you have an adapter Option Diskette 2 At the Process Adapter Option Diskette screen follow the instructions and Remove LSP 1 3 Installation Diskette from the drive Insert the Trumpcard driver diskette Press ENTER 3 8 Trumpcard Ethernet LAN Operation 3 At the Current Configuration screen go to the box Selections for Adapter and select Ositech Trumpcard 4 Press F4 to install the IBM LSP and the Ositech Trumpcard NDIS driver End of Installation The following are examples of possible CONFIG SYS file setups These lines would be present in the CONFIG SYS file For one NDIS adapter with both IEEE 802 2 and NETBIOS support the sequence is as follows DEVICE C LSP PROTMAN DOS I LSP DEVICE C LSP OTCETH DOS DEVICE C LSP DXMAOMOD SYS 001 DEVICE C LSP DXMEOMOD SYS DEVICE C LSP DXMTOMOD SYS O N For one NDIS adapter with only NETBIOS support the sequence is as follows DEVICE C LSP PROTMAN DOS I LSP DEVICE C LSP OTCETH DOS DEVICE C LSP DXMAOMOD SYS 001 DEVICE C LSP DXMJOMOD SYS The following is an example of a possible PROTOCOL INI file setup PROTMAN_MOD DRIVERNAME PROTMANS DXMEO_MOD
30. ing the specified interrupt If the keyword does not exist the default interrupt level will be 5 if Card Services is not present otherwise the first available interrupt obtained from Card Services will be used IOBASE I O port Description Set the UO port Default 300 or AUTO Accepted values Any location within a 64 port boundary 300 and up in increments of 40 with the upper limit dictated by the individual machine Note If this keyword exists the driver will return an error if unable to operate using the specified I O port If the keyword does not exist the default I O port will be 300 if Card Services is not present otherwise the first available I O port obtained from Card Services will be used NETADDRESS nnnnnnnnnnnn s Description Station address used to override the default PROM value Default None driver uses PROM Accepted values Valid hexadecimal for a Station Address according to Ethernet pattern SOCKET socket number Description Enable operation with PCMCIA socket indicated Default Auto Accepted values 1 2 or Auto Note Specifying a socket number will limit the driver to only checking that socket for the presence of a Trumpcard MAXTRANSMITS lt transmits gt Description Maximum transmit queue blocks Default 4 Accepted values Any value between 4 40 inclusive 4 6 Trumpcard EthernetLAN PROTOCOL INI Example An example of a possible PROTOCOL INI file follows
31. n the Trumpcard driver diskette to the Banyan VINES directory i e COPY A VINES OTCETH DOS C VINES Use an ASCII text editor and edit the CONFIG SYS file to include the following lines DEVICE C VINES PROTMAN DOS I C NVINES DEVICE C VINES OTCETH DOS The command to edit the file is EDIT C NCONFIG SYS Change to the VINES directory User s Guide and Reference 3 3 Section Three Type PCCONF IG and select Network Card Settings and then select NDIS Ethernet Atthe PROTOCOL INI bindings prompt type OSITECH_NIF and press F10 to save and press ESC to return to main menu Select Login Environment Settings then select Default Communications driver then select NDIS Ethernet Press ESC to return to main menu and F10 to save Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C DEC PATHWORKS To install DEC PATHWORKS version 4 1 on a DOS NDIS workstation you can use the automated installation provided with PATHWORKS for the Ositech Trumpcard NDIS device driver 1 Install DEC PATHWORKS using the instructions provided in the DEC PATHWORKS manual In order to set up the Trumpcard Network adapter for use with DEC PATHWORKS please run the PATHWORKS Network setup software i e NETSETUP Choose Ethernet controller type and
32. nal ms odimac 1 ms netbeui lana2 osiSotceth 1 ms nwlinknb net cfg PATH C NOVELL NET CFG OSISOTCETH LINK DRIVER OTCETH Link Driver XXXX Link Support NewMaxBoards Max Boards 8 OldMaxBoards Max Boards 8 User s Guide and Reference Section Three NWLINK BINDINGS OTCETH In your CONFI NETBEUI BINDINGS OTCETH XXXX LANABASE 0 SESSIONS 10 G SYS the following line should be present DEVICE C WINDOWS IFSHLP SYS In your AUTOEXEC BAT the following lines should be present C WINDOWS NETSTART CD NOVELL LSL OTCETH IPXODI C WINDOWS ODIHLP EXE NETX Your NET CFG file under the Novell directory would contain the following lines LINK DRIVER OTCETH Frame Ethernet_802 3 Frame Ethernet II Frame Ethernet 802 2 Frame Ethernet SNAP LINK DRIVER XXXX Frame Ethernet 802 3 Frame Ethernet II Frame Ethernet 802 2 Frame Ethernet SNAP Link Support Max Boards 8 Refer to the Installation Instructions for Novell Networks for details on Netware installation and setup Note If the Trumpcard is a Multi Function adapter additional steps may be required to complete the full installation Refer to the Installation Guide accompanying the adapter for more details Note Keyword specifications associated with the NDIS driver are explained in Appendix B E
33. ng to Ethernet pattern User s Guide and Reference 4 3 Section Four PROTOCOL named protocol gt protocol id gt lt frame type gt Description Associate the named protocol with the protocol id Default Pre defined Novell values Accepted values Refer to Novell documentation SOCKET socket number Description Enable operation with PCMCIA socket indicated Default Auto Accepted values 1 2 or Auto Notes Specifying a socket number will limit the driver to only checking that socket for the presence of a Trumpcard LOOK AHEAD SIZE look ahead value Description Set the look ahead size to pass to the protocol stack Default 18 Accepted value Any even value between 18 and 256 inclusive NET CFG Example An example of a possible NET CFG file is as follows Link Driver OTCETH FRAME ETHERNET 802 3 EDIA 10BASET EXCLUSIVE DISLINK INT 5 EM D000 PORT 300 ODE ADDRESS 000079821660 PROTOCOL IPX 0 ETHERNET 802 3 DOE AHEAD SIZE 120 SOCKET 1 4 4 Trumpcard Ethernet LAN Appendices APPENDIX B NDIS Keywords The following NDIS keywords are supported by the Trumpcard NDIS drivers The keywords must be in the PROTOCOL INI file under the section with a DriverName OTCETH If the keyword is not present the default value shown will be assumed MEDIAz media type Description Media type selected by the driver Default A
34. nsport msSnetbeui MSSNETBEUIL lanaO msSotcethSnic 1 ms netbeui protman DriverName PROTMANS PRIORITY MSSNETBEUI MSSOTCETHSNIC DriverName OTCETHS MEM 0xc800 Interrupt 5 TOBase 0x300 Trumpcard Ethernet LAN Operation MSSNETBEUI Drivername netbeui SESSIONS 6 NCBS 12 BINDINGS MSSOTCETHSNIC LANABASE 0 Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C NDIS Generic These steps outline how to install the Trumpcard NDIS device driver for Network operating systems that are not described in this manual and will operate with a NDIS driver The easiest way to perform the installation is to install a NDIS driver that is supported by the Network operating system and then edit the required files to use the Trumpcard NDIS driver These steps will apply to both DOS and OS 2 environments The 3COM Etherlink driver will be used as an example but any NDIS driver will do 1 Follow the instructions for workstation installation in the installation manual 2 When prompted for the adapter select any of the available ethernet adapters that support NDIS i e 3COM ETHERLINK 3 Continue with the installation until complete 4 After the automatic installation has completed you must make changes to your CONFIG SYS and PROTOCOL INI files as well as copying over the Trumpcard NDIS driver 5 Fi
35. or use by the network driver Errors related to releasing resources should not occur under normal circumstances if these errors occur contact technical support for assistance Unable to configure Trumpcard The driver was unable to successfully configure the Trumpcard for network operation Only supported on PCMCIA 2 x or higher Socket Card Services The OTCETH xxx network driver will only support PCMCIA Socket and Card Services software that comply with PCMCIA version 2 x or higher Contact your computer manufacturer or dealer for more details on how to obtain a current version User s Guide and Reference 4 9 Section Four The expected Tuple not found The network driver has been unable to locate configuration information needed to operate the network Run the diagnostic software accompanying the Trumpcard to correct this situation Must be an AT 286 or higher system The network driver requires that the computer as a minimum is a PC AT 80286 or higher Hardware not responding Run the diagnostic software accompanying the Trumpcard PC Card to verify that the hardware is functioning properly No Media Cable Connected The network driver was instructed to auto detect the media cable connected but no media connection was detected If a media connection does exist run the diagnostics accompanying the Trumpcard to verify that the hardware is functioning properly 4 10 Trumpcard Ethernet LAN Appendices ODI Specific E
36. pecifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C Microsoft Windows for Workgroups To install Microsoft Windows for Workgroups WFW versions 3 1 and 3 11 the Trumpcard driver diskette contains the required files to allow the WFW installer to import an OEM disk 1 Run the Windows for Workgroups installation according to the manual provided 3 10 Trumpcard Ethernet LAN Operation 2 When prompted for INSTALL NEW NETWORK ADAPTER select Unlisted or Updated Network Adapter 3 When prompted to INSERT NETWORK DRIVER DISKETTE IN DRIVE AT place the Trumpcard driver diskette in drive A 4 For WFW 3 1 enter A WFW 31 For WFW 3 11 enter A WFW 311 If you have used the configuration software to configure the Network driver diskette use the default A Then select Ok 5 Select OSITECH TRUMPCARD from menu 6 Continue with installation until complete If you have setup to use both the WFW 3 11 and Novell ODI the following example shows the PROTOCOL INI CONFIG SYS AUTOEXEC BAT and NET CFG file changes made during the installation of Windows for Workgroups version 3 11 Your PROTOCOL INI file under the Windows directory should contain the following Network setup version 0x3110 netcard osiSotceth 1 OSISOTCETH 4 netcard msSodimac 1 MSSODIMAC 4 transport ms nwlinknb NWLINK transport ms netbeui NETBEUI lana0 osiSotceth 1 ms netbeui la
37. rnet Adapter connector at the other e For a multi function Trumpcard the Ethernet connection is identified on the back of the PC Card Insert the PCMCIA Ethernet Adapter connector into the one marked Ethernet e Connect the male RJ 45 connector into an input port of a 10BaseT compatible concentrator Ethernet Adapter Connector Network Port Connector 10 Cable Direct 10BaseT Ethernet Connection User s Guide and Reference 2 3 Section Two The second method of connecting to a 10BaseT Network is via the Media Access Module A female RJ 45 connector is provided on the Media Access Module for 10BaseT Network connections To connect the Trumpcard to a 10BaseT Network connection using the Media Access Module follow these steps For a multi function Trumpcard the Ethernet connection is identified on the back of the PC Card Insert the PCMCIA Ethernet Adapter connector on the Media Access Module into the one marked Ethernet Plug the male RJ 45 connector from the Network access cable into the female RJ 45 connector on the Media Access Module Note The Trumpcard is keyed to go in one way only If you feel resistance before it is fully inserted remove it turn it over and re insert it Ethernet Adapter Connector Red Activity LED Unshielded Twisted Pair Ethemet Network Cable Media Access Module 10BaseT Network Connection 2 4 Trumpcard Ethernet LAN Hardware Installation Interface Cabling and
38. rror Messages MLID could not be unloaded the operation was aborted MLID could not register Protocol ID This version of LSL is not supported The frame type is already activated for frame The node address was incorrectly specified in NET CFG An invalid keyword was specified in NET CFG on line nnn The frame type specified in the NET CFG is not supported The LSL is not loaded The LSL has no more room for a board using Frame xxxxxxxxxx The above error messages are specific to the Trumpcard Ethernet ODI drivers The error messages are self explanitory and are only shown for completeness H NDIS Specific Error Messages Media Parameter is Invalid Socket Parameter is Invalid Mem Parameter is Invalid NetAddress parameter is invalid MaxTransmit parameter is invalid Can not establish a unique name for driver The above error messages are specific to the Trumpcard Ethernet NDIS drivers The error messages are self explanitory and are only shown for completeness User s Guide and Reference 4 11 Section Four Trumpcard Ethernet LAN
39. rror Messages in Appendix C Trumpcard Ethernet LAN Operation Microsoft Windows NT 3 5 The Trumpcard Windows NT 3 5 NDIS3 0 driver is a Network driver and enabler for Intel Databook and compatible PCMCIA equipped computers With this driver installed networking functions will be available under Windows NT 3 5 Note Note The Trumpcard Windows NT 3 5 driver requires that the Trumpcard PC Card be inserted prior to the driver being loaded If no Trumpcard is found the driver will not be loaded and networking functions will NOT be available When the driver has successfully loaded if the Trumpcard is now removed from the PCMCIA slot unpredictable results will occur The Trumpcard Windows NT 3 5 Driver DOES NOT support hot insertion and removal hot swapping To install the Trumpcard NDIS3 0 Network driver for Windows NT 3 5 the Trumpcard Network Drivers diskette contains the required files to allow Windows NT installer to import an OEM disk 1 From the Main Program Group select CONTROL PANEL and then NETWORK Choose ADD ADAPTER then select OTHER from the Network Adapter Card list of choices Select CONTINUE when prompted to insert the disk and to enter a path name place the Network Driver diskette into the floppy drive and enter A WINNT35 The default settings will work in most environments Select CONTINUE once finished configuring the LAN driver select OK once finished setting up the Network
40. rst edit the CONFIG SYS file on the root c gt drive This is done by using a standard text editor such as EDIT in DOS or E in OS 2 6 In the CONFIG SYS file locate the lines that are related to the Network operating system being used Typically the lines would be DEVICE C lt path gt PROTMAN SYS I lt path gt DEVICE C lt path gt ELNK DOS DOS or DEVICE C lt path gt ELNK OS2 OS2 User s Guide and Reference 3 15 Section Three Change the second line above to DEVICE C lt path gt OTCETH DOS DOS or DEVICE C lt path gt OTCETH OS2 OS2 Save the changes made to this file 7 Next edit the PROTOCOL INI file the file will be in the lt path gt directory In this file under the heading ELNK_NIF please change the line DRIVERNAME ELNK to read DRIVERNAME OTCETH Also remove any existing settings under this line i e INTERRUPT IOADDRESS DMACHANNEL etc Remove any keywords that were for the 3COM Etherlink driver Add any required settings using the keywords described in Appendix B Save the changes made to this file 8 Finally place a copy of the Trumpcard NDIS Device Driver OTCETH DOS from the DOS subdirectory or OTCETH OS2 from the OS2 subdirectory on the Trumpcard driver diskette to the directory on your hard disk drive that contains your Network files lt path gt Your Network installation is now complete
41. select Other NDIS Insert the Trumpcard driver diskette into drive A When prompted for the path to the driver file type A DOS OTCETH DOS When prompted for the path to the PROTOCOL INI file type A NDOS Trumpcard Ethernet LAN Operation 7 Complete NETSETUP and return to the DOS prompt The PROTOCOL INI file in your DECNET directory should appear something like the following protocol manager DRIVERNAME PROTMANS IPX4MAC DRIVER IPXSMAC INDINGS OTCETH DOS D DATALINK RIVERNAME LLSMAC G_BUFFERS 16 D L SM_BUFFERS 6 O H UTSTANDING 32 EURISTICS 6 BINDINGS OTCETH DOS OTCETH DOS DRIVERNAME OTCETHS Your CONFIG SYS file should contain the following lines DEVICE C DECNET PROTMAN SYS I C NDECNET DEVICE C DECNET OTCETH DOS Your AUTOEXEC BAT file should contain the following line CALL DECNET STARTNET Note Keyword specifications associated with the NDIS driver are explained in Appendix B Error Messages in Appendix C FTP Software LanWatch The Ositech Trumpcard hardware and software supports promiscuous mode operation allowing it to work with products such as FTP s LanWatch The Ositech Trumpcard NDIS device driver installation will be automated to work with LanWatch once copied over to your hard disk 1 Create a directory on the C drive called NDIS i
42. structions for installing the IBM LAN Support Program Trumpcard Ethernet LAN Operation For an OS 2 workstation you must first install LAN Adapter and Protocol Support LAPS and then import the Trumpcard driver 1 Follow the instructions for installing LAPS in accordance with your IBM LAN Adapter and Protocol Support Configuration Guide You must first install LAPS on the workstation in order to install additional Network adapter drivers 2 Issue the LAPS command from the IBMCOM subdirectory of the drive that contains the copy of LAPS 3 Select INSTALL from the LAPS logo window 4 When prompted for the source path of additional Network drivers enter A OS2 Insert the Trumpcard driver diskette into Drive A 5 Select Configure then select Configure LAN Transports and then select Continue 6 Remove any existing adapters and protocols from the Current Configuration menu that are not required 7 Select Ositech Trumpcard adapter from the Network Adapters menu and then select Add 8 Add the required protocols from the Protocol menu and finally select OK when complete After installation of the Trumpcard NDIS device driver and protocols you must install the needed requester DOS or OS 2 to complete the installation The following are examples of changes made to the CONFIG SYS and PROTOCOL INI files on an OS 2 workstation installation CONFIG SYS EVICE C IBMCOM LA
43. that you can assign to the driver in the range of 0xc0000 and 0xf0000 The default is 0xc8000 Ability to use netconfig to configure the Network software 2MB of free disk space for the various temporary files that are created during the install process on the file system containing the tmp directory To create the Ositech Trumpcard LLI Driver install diskette and to install the driver you need only execute the INSTALL shell script that you have copied to the tmp directory You can only execute the INSTALL script after you have become the root user It is highly recommended that you run the shell script as root in single user mode because the installation process will require that you relink the kernel su enter the root password at the Password prompt If you are not already in the System Maintenance mode use the following command to reboot the machine etc shutdown il INIT SINGLE USER MODE Type CONTROL d to proceed with normal setup or give root password for system maintenance enter the root password to activate the System Maintenance mode cd tmp sh install Then simply follow the instructions provided by the installation script to complete the installation of the driver Trumpcard Ethernet LAN Section Four Appendices User s Guide and Reference Appendices Section Four APPENDIX A ODI Keywords The following ODI keywords are supported by the Trumpcard ODI driv
44. valid interrupt value excluding 0 1 2 6 8 and 13 Note If this keyword exists the driver will return an error when unable to operate using the specified interrupt If the keyword does not exist the default interrupt level will be 5 if Card Services is not present otherwise the first available interrupt obtained from Card Services will be used MEM memory location Description Maps to 4K host memory location Default C8000 Note When Card Services is not present the only scenario in which this keyword applies the Trumpcard driver will require the 4K memory window in order to determine the Trumpcard s presence If running a memory manager such as EMM386 or QEMM make sure to exclude the memory range used i e X C800 C8FF PORT I O port Description Set the UO port Default 300 or AUTO Accepted values Any location within a 64 byte boundary 300 and up in increments of 40 with the upper limit dictated by the individual machine Note If this keyword exists the driver will return an error if unable to operate using the I O port specified If the keyword does not exist the default I O port will be 300 if Card Services is not present otherwise the first available I O port obtained from Card Services will be used NODE ADDRESS nnnnnnnnnnnn Description Station address used to override the default PROM value Default None driver uses PROM Accepted values Valid hexadecimal for a Station Address accordi
45. ware Installation Note In order to assist with the installation and configuration of networks drivers Ositech has provided Installation Software for the DOS Windows and OS 2 operating systems Follow the instructions printed on the appropriate diskette label for details on how to invoke the Installation Software For operating systems other than DOS Windows and OS 2 please refer to the appropriate section for instructions on how to install and configure the Network driver under these operating systems The following sections provide details on how to install and configure the Trumpcard Ethernet Network drivers The Network operating systems have been listed alphabetically If the Trumpcard you are using provides other functions in addition to Ethernet networking please refer to the Installation Manual accompanying the Trumpcard for details on how to operate the functions simultaneously Banyan VINES To install Banyan VINES version 4 x and later on a DOS NDIS workstation you must manually install the Ositech Trumpcard NDIS device driver 1 Follow the instructions for workstation installation in accordance with your Banyan VINES workstation installation manual At this point you should have all the relevant Banyan VINES files in a directory on your hard disk drive In this manual we will assume that the Banyan Vines directory is called VINES Copy the files PROTOCOL INI and OTCETH DOS from the VINES directory o