Home
Oricom M5050 User's Manual
Contents
1. Oricom M5050 Additional 1 8GHz DECT Cordless Handset amp Charger Use with M5000 series or any GAP compatible DECT phone User Guide M5050 User guide doc Page 1 of 6 ABOUT YOUR PHONE This Oricom cordless handset is compatible with any Oricom M5000 series base or any other DECT GAP compatible cordless phone Note that not all original functions may operate when used with another brands base unit 1 Getting Started This package should contain the following 1x Handset 1x Handset Battery Cover 1x Handset Base 1x Mains Power Adapter 2x Rechargeable Batteries AAA Ni MH 1 2V 600mAh 1x User guide Warranty card If any of these items are missing please contact the retailer where you purchased the product from CAUTION Use only the mains power adaptor charger supplied with this telephone Incorrect adapter polarity or voltage can seriously damage the unit Input 230 Vac 50Hz CAUTION RISK OF EXPLOSION IF BATTERIES ARE REPLACED WITH INCORRECT TYPE Refer to the original type supplied with this telephone Ni MH batteries must be disposed of in accordance with applicable waste disposal regulations CAUTION This telephone is not designed for making emergency telephone calls when the mains power fails Ensure there are alternative arrangements for access to emergency services via a mobile phone or a corded telephone ALWAYS have a corded or mobile phone available 24 hours a day Do not use your telephone during an
2. UNLOCK LAST NUMBER Answer a call redial When the handset rings 1 Press PHONE or SPEAKERPHONE button Note Call timer The call timer shows the duration of your current call on display End a call VOLUME Call button for earpiece amp ringer C 1 Press PHONE or SPEAKERPHONE button The i symbol disappears from the display M5050 User guide doc Page 3of6 M5050 User guide doc Page 4of6 ABOUT YOUR PHONE 6 Multi handset use Your M5000 series phone can have up to 5 handsets registered to 1 base unit Each handset has its own number HS 1 HS 2 HS 3 HS 4 amp HS 5 shown on the left hand side of the display A maximum of 1x outside call amp 2x intercom calls can take place per base unit If you make an outside call another handset is on line result is a busy tone If you make an intercom call one is already in progress result is a busy tone With 2 or more handsets you can Make an intercom call Press INTERCOM button When you hear your outgoing message press Key the handset number 1 2 3 4 OR 5 you wish to call On the RECIEVING handset press PHONE button To end press PHONE button on the CALLING handset The RECIEVING handset will hear a busy tone ee Transfer a call between handsets Press INTERCOM button Key the handset number 1 2 3 4 OR 5 you wish to call On the RECIEVING handset press PHONE button to receive call Press PHONE button on the CALLING handset to trans
3. all respects with another item of Telepermitted equipment of a different make or model nor does it imply that any product is compatible with all of Telecom s network services This device may be subject to ringing or bell tinkle when certain other devices are connected to the same line If this occurs the problem should not be referred to the Telecom Faults service This equipment shall not be set to make automatic calls to the Telecom 111 Emergency Service This equipment may not provide for the effective hand over of a call to another device connected to the same line REN RN for New Zealand The REN Ringer Equivalence Number or RN is of significance only if you wish to connect more than 1 telephone to your telephone line A standard telephone line has a maximum REN capacity of 3 RN of 5 It is possible to connect 3 5 devices with a REN of 1 RN of 1 with no degradation to the product s performance Exceeding this limit may cause the volume of the ringer in any phone to decrease or not ring at all Caller ID Customers in NZ using NON TELECOM toll services should not use the dial back feature for local calls as this will incur a charge only the 7 digit number should be dialled Some of the CID services listed may not be available in New Zealand This telephone is NOT designed for making emergency telephone calls when the power fails Ensure there are alternative arrangements for access to emergency services via a mobile phon
4. e or a corded telephone 8 Warranty Information This product is covered by a 12 month warranty against defective workmanship or parts The warranty does not extend to damage caused by misuse negligence excessive voltage faults on the telephone line or lightning This guarantee in no way affects your statutory rights Full details of the warranty are contained in the enclosed warranty card If you feel this product is not working correctly please consult the user guide and ensure that you are using the product in accordance with the instructions Remove all extra telephone equipment and connect only this telephone directly to the telephone socket If the fault is still present connect another telephone if available to the telephone socket The results will show you whether the fault lies with this unit or with the telephone line If the product is working correctly the fault is on the telephone line Please contact your network operator for assistance To orders spare parts additional handsets replacement batteries and in case of any technical issues you may have with product please consult our website for further information or send us an email for a prompt response to your enquiry In the unlikely event of a fault developing please contact us for assistance If the product is then found to be faulty you will be asked to return it directly to us with a copy of the purchase receipt Australia New Zealand Oricom International Pty Ltd Atlas Gent
5. ech NZ Ltd PO Box 5681 South Windsor NSW 2756 Private Bag 14927 Panmure Auckland Customer support Customer support Email support oricom com au Email support atlasgentech co nz Web www oricom com au Web www atlasgentech co nz Fax 02 4572 0939 Fax 09 574 2722 Ph 1300 889 785 Ph 0900 50 025 Toll Call M5050 User guide doc Page 6of6
6. electrical storm thunderstorm as it is possible to get an electric shock Refer to information contained in White pages directory M5050 User guide doc Page 2of6 ABOUT YOUR PHONE ABOUT YOUR PHONE 2 Setting up your phone 4 Registering Handsets f Note Before you can use this handset You need to Basic steps to setup 1 Charge the batteries for 14 hours 2 Register the handset to the Base unit 1 Plug the mains power adapter of the charger into the wall mains supply 2 Insert the two AAA batteries observing the correct polarity into the battery compartment on the handset 3 Slide the battery door firmly into place 4 Place the handset on the base unit or the charger and let the batteries charge for a full 14 hours before using Register a handset Handset may get warm during initial charge This is normal Ensure wall mains supply is switched ON This handset is GAP compatible You must go through the registration process with a base unit in order for it to 5 Register the handset to the base unit Refer to Register Handsets section for details operate Each handset can register to one base at a time only The current base will be deregistered when a new base is registered If you register the handset with another manufacturer s base unit some features may not be available Note Before you can use this handset You need to 1 Charge the batteries for 14 hours The following procedure may not apply if the base unit
7. fer Call will return back within 90 seconds if Unanswered e Sh a Switch between calls An outside call an intercom call in progress you switch between the 2 calls 1 Press INTERCOM button to speak to outside call while the intercom call is on hold 2 Press INTERCOM button again to speak to intercom call while outside call is on hold 3 Press PHONE to transfer outside call to the other handset while connected to intercom call If you press the PHONE button while connected to the outside call you will disconnect If the other handset user presses the PHONE button to hang up you will be left with the outside call Conference calls A 3 way call between yourself outside call intercom call 1 Either make or answer an outside call Press INTERCOM button Key in the other handset number 1 2 3 4 OR 5 On the RECIEVING handset press PHONE button to receive call Press INTERCOM button amp hold for about 3 seconds aR WN F 5 When connected both symbols are shown on display bi M5050 User guide doc Page 5of6 ABOUT YOUR PHONE 7 Notes for operation in New Zealand The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with the minimum conditions for connection to its network It indicates no endorsement of the product by Telecom nor does it provide any sort of warranty Above all it provides no assurance that any item will work correctly in
8. is from another manufacturer Please refer to the instruction 2 Register the handset to the Base unit manual of the base unit Ensure no handset is resting on the base unit s charging cradle 1 Press amp hold HANDSETLOCATOR button on the BASE UNIT for 10s until the IN USE light flashes you have 3 3 About your phone minutes to register handset 2 Key in a base unit number 1 2 3 OR 4 If you have one base unit key in 1 g 3 Key in your handset s PIN code default 0000 Your Oricom M5000 Handset oneal j 4 Handset now registered You will hear a tone display shows a handset number a PHONE button 5 Making Calls Ge Arrow RIGHT RECALL CALLER Note OUT OF RANGE warning Button DISPLAY You may be out of range with the BASE UNIT if you hear a warning tone or the sound becomes distorted button Either 1 Move handset closer within 20 seconds until the tone stops Otherwise your call may be cut off 2 Reposition amp reconnect BASE UNIT to a phone connection closer to where the handset will be used MEMORY DEL MUTE an extension lead s for power amp telephone line may be useful where necessary m button DELETE button O T Make a handset call Speaker INTERCOM N Sor 1 Key number into telephone 7 7 2 If necessary press MUTE DEL to clear single digit or Press amp Hold MUTE DEL to clear all digits A Ringer ON Keypad 3 Press PHONE button to dial OFF button LOCK 4 if necessary press LAST NUMBER REDIAL button
Download Pdf Manuals
Related Search
Related Contents
Bosch PLR 30 C Sun Fire X4600 and Sun Fire X4600 M2 Servers Service Manual MOV-Handbuch - Afag Handhabungs Copyright © All rights reserved.
Failed to retrieve file