Home
Oregon Scientific WMR100NA User's Manual
Contents
1. Wind speed levels AVERAGE MAX GUST Wind speed level indicator Outdoor wind sensor battery is low Wind speed level description Gust wind or wind speed reading m s kph mph or knots HI gust wind alarm is set Wind direction display UVI Barometer Rainfall Area 1 O oO AO N eh UVI Hr A 38 di 10 8 6 4 2 O 4E BEB M gt 4 gt 24 na 2 RAIN GJJ PE Accum Te wa UVI None Pres 9 aitat t V Vey inHg COW MED V HI EX HI PE RRB 4 2 0 ON EEEE ie sE HEHEHEHEHE ole SEEE os 4H BRB 4 0 4 CHHEEEEH 6 Ol OB EEE HEHE lt 6 lt o 24 l2 6 3 1 OHr mbin UVI barometer rainfall readings is showing Outdoor UV rain sensor battery is low UV barometer rainfall alarm is set LL z 4 Rain rate is showing 5 UVI barometric pressure mmHg inHg or mb hPa rainfall readings in hr or mm hr UVI level indicator Accumulated rainfall is showing Past 24hrs rainfall is showing Altitude is showing 0 UVI barometric pressure rainfall historical bar chart display oO oN o Clock Alarm Calendar Moon Phase Area 1 2 4 3 ae gD OL wo 6 1 Clock radio pecs pion I Winddireaion 2 Alarm 1 and 2 are displayed and set o 2 Wind vane casing 3 Timestamp is displayed 3 Anemometer o gt Ofgar ime zone 4 Solar power socket 5 Moon phase j 6 Time date calendar Humidity Dew Point Area Base and funnel 1 Rain gauge 2 Bat
2. _ z Lu Advanced Weather Station with Wireless Sensor Set amp Mounting Package Thank you for selecting the Oregon Scientific Weather Model WMR100N WMR100NA Station WMR100N WMR100NA USER MANUAL The base station is compatible with other sensors To purchase additional sensors please contact your local retailer x Packaging Contents a Sensors with this logo 3 6 are compatible with this Base station ceccicesccancayssnecdcacecnececcecedisuacs teevacecevenbecee 1 Wind Sensor Temperature amp Humidity Sensor 1 Rain AGA OG esseeri iiin ene aE RERAN 2 NOTE Please keep this manual handy as you use Assembly Par is a EEEE 2 your new product It contains practical step by step Accessories TVS ONS ahs cecsceddepccssasabancuasessnnaienneeeacs 2 instructions as well as technical specifications and Overview a A a Aa a sc 2 warnings you should know about Front VIe W scccccacccseittin seacacccd cee saceeeeeedattecetdacapedenste 2 Back VieW acer cesses anad nectetntamnetanaitistneaceddvaperdicwinecienes 3 EE EAE cio T AEAEE EAO E 3 PACKAGING CONTENTS Wind SONS OR ii eere aa EES REER eaii 4 Rain Gauge wiusatecatonantaarecassraaaattesaasaaunsnesdeenensnicuteenes 4 Outdoor Temperature Humidity Sensor 5 Getting Stare Go sccccvessrsasceacctwetsrirortrtcrerecceedepa 5 Set Up Remote Wind Sensor ccccsscceeeeeeeees 5 J Set Up Remote Temperature Humidity Sensor 5 ty Remote U
3. of the versatile base and hammer down 16 Using the string tie a knot on the eye pins Hammer each eye pin into the ground at a 90 angle IMPORTANT Using the fasteners tighten the string To tighten pull fastener down To loosen thread the string up through the fastener eyelets 1 Secure the plastic base onto existing pole with U bolts washers and bolts 2 Insert the horizontal attachment bracket into the base 3 Using a screw fix firmly into place 4 Insert wind sensor into the top of the bracket 5 Using screws fix aluminium pole firmly into place 6 Slide outdoor sensor onto bracket IMPORTANT For best results point the wind vane North ALTERNATIVE SET UP TEMPERATURE HUMIDITY SENSOR MOUNTED SEPARATELY 1 Insert 4 type A screws into the holes of the sensor connector Screw firmly into place i e fence SET UP RAIN GAUGE The rain gauge collects rain and takes readings of rainfall rate and the total rainfall over a period of time The sensor can remotely transmit data to the base station The base station and rain gauge should be positioned within an effective range about 100 meters 328 feet in an open area The rain gauge should be mounted horizontally about 1 meter 3 feet from the ground in an open area away from trees or other obstructions to allow rain to fall naturally for an accurate reading To set up the Rain Gauge 1 Remove screws and slide the
4. MODE to enter the altitude setting 2 Rotate the dial left or right to set the desired values 3 Press MODE to confirm the setting To view the current hour accumulated or last 24 hours rainfall history In the UV Barometer Rainfall Area and Rainfall reading display press MEMORY ON OFF repeatedly to toggle between current past 24 hours or accumulated rainfall The clock line will change to display the start time when the accumulated rainfall is displayed The icon SINCE appears and the start date is showing To toggle between rainfall amp rain rate display In the UV Barometer Rainfall Area and Rainfall reading display press and hold MODE To reset the accumulated rainfall and timestamp In the UV Barometer Rainfall Area and Rainfall reading display Press and hold MEMORY A ON OFF to reset the accumulated rainfall to 0 and to set the timestamp to current date and time To change the HI rainfall rate alarm 1 In the UV Barometer Rainfall Area and Rainfall reading display press and hold ALARM to enter the Rainfall alarm setting 2 Rotate the dial left or right to set the desired values 12 3 Press ALARM to confirm the settings To activate deactivate the HI rainfall rate alarm 1 In the UV Barometer Rainfall Area and Rainfall reading display press ALARM repeatedly to select the desired alarm 2 Press MEMORY A ON OFF to activate or deactivate the alarm WE
5. cc1 ccccsssscesssseeessseeeesssseeeeenes 12 Set Up Software First time use sseeeeeeee 12 _ i 2 x AA UM 3 Additional step for Windows Vista users only 12 F 1 5V batteries Install SOR WAN CS estes cca cists cetenatiieccesiaiconeesadeccadetaoans 13 Disable Sleep Mode ccccccceeceeeceeeesseeeeeeeeeeees 13 4x Wind To disable sleep mode on computer 0 13 Sensor Windows XP 1 x Wind p T To disable sleep mode on computer 0 13 Wane Above Windows Vista maT Upload data to PC Software ccccsssseeeeeeeeeeeeees 13 Anemone 1 x Aluminium 2 x AAA UM 4 Software UPCates ccccceee cesses cess seen nenn nnnnn nenen nnna 14 Below pole 1 5 batteries Backlight veasciiec sp ceccastcnnxneceecaxmncaccennencccceceeesennicennmsonuns 14 i RESO ene eee eee 14 PDC CIC AUIONS issii iniinum iird ien 14 Precautions siiis isociiiinsninnninnn eiiiai iai aana E 15 About Oregon Scientific aasessssnennnsnnnnnnnnnnnn nenne 15 EU Declaration of Conformity ceeeee 15 FCC Statement sccceess sceccuncticietrrensistevnncei teenies 16 _ E 4 x Screws ja Type A 1x Temperature 1 x Temperature Humidity Humidity Sensor casing Sensor 1 x sensor connector gt l 4 x Screws 1 x Filter Type C LS oO 1 x Rain 2 x AA UM 3 6 x Washers Collector 1 5V batteries if y N See e 1x Vertical 1 x Cone 1 x Horizontal Attachment Shaped End Attachment B
6. comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help The following information is not to be used as contact for support or sales Please visit our website at www2 oregonscientific com service for all enquiries We Name Oregon Scientific Inc Address 19861 SW 95 Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No WMR100N WMR100NA Product Name Advanced Weather Station with Wireless Sensor Set amp Mounting Pack
7. cover off in an upwards motion 2 Insert the batteries 2 x UM 3 AA matching the polarities Press RESET after each battery change 3 Remove the fibre tape To ensure a level plane Put a few drops of water on the cross at the base of the funnel to check the horizontal level Water will pool to the center of the cross when the rain gauge is level If water remains on 1 4 the gauge is not horizontal If necessary adjust the level using the screw i INOTE For best results ensure the base is horizontal to allow maximum drainage of any collected rain z m SET UP BASE STATION NOTE Install batteries in the remote as before the base station matching the polarities and s For eoniindous use please install the AC adapter The batteries are for back up use only NOTE Make sure the adapter is not obstructed and is easily accessible to the unit NOTE The base station and adapter should not be exposed to wet conditions No objects filled with liquid such as vases should be placed on the base station and adapter Install the base station batteries 4 x UM 3 AA matching the polarity and Press RESET after each battery change NOTE Do not use rechargeable batteries It is recommended that you use alkaline batteries with this product for longer performance NOTE Batteries should not be exposed to excessive heat such as sunshine or fire The battery icon indica
8. of mercury mmHg inches of mercury inHg millibars per hectopascal mb hpa e Rainfall Millimeters mm inches in inches per hour in hr or millimeters per hour mm hr The UV index levels are as follows UV INDEX ICON 02 LOW 38 MED Hi 8 10 V HI 11 and above X HI To change the high UV alarm 1 Inthe UV Barometer Rainfall Area and UVI reading display Press and hold ALARM to enter the high UV alarm setting SEE LL 2 Rotate the dial left or right to set the desired values 3 Press ALARM to confirm the settings To activate deactivate the high UV alarm 1 Inthe UV Barometer Rainfall Area and UVI reading display press ALARM repeatedly to select the desired alarm 2 Press MEMORY A ON OFF to activate or deactivate the alarm To change the barometer alarm 1 Inthe UV Barometer Rainfall Area and Barometer reading display press and hold ALARM to enter the Barometer alarm setting 2 Rotate the dial left or right to set the desired values 3 Press ALARM to confirm the settings To activate deactivate the barometer alarm 1 Inthe UV Barometer Rainfall Area and Barometer reading display press ALARM repeatedly to select the desired alarm 2 Press MEMORY A ON OFF to activate or deactivate the alarm To set the altitude level compensation for the Barometer readings 1 Inthe UV Barometer Rainfall Area and Barometer reading display Press and hold
9. signed and dated Declaration of Conformity is available Battery 2 x UM 3 AA 1 5V on request via our Oregon Scientific Customer Service no obstructions Approx every 60 seconds 1 for Wind Rain UV and 10 for Temp Humidity NOTE Features and accessories will not be available in all countries For more information please contact your local retailer ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products If you re in the US and would like to contact our Customer Care ai PRECAUTIONS C CO ROHS e Do not subject the unit to excessive force shock a COMPLIANT dust temperature or humidity e Donotcover the ventilation holes with any items such as newspapers curtains etc e Do not immerse the unit in water If you spill liquid COUNTRIES RTTE APPROVAL COMPLIED All EU countries Switzerland CHD and Norway CN gt 15 EN EN W LL FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to
10. to the right to secure 5 Slide temperature and humidity sensor onto the smaller end of the sensor connector REMOTE UNIT ASSEMBLY 1 Insert the cone shaped end into the pole 2 Using 2 screws fix it firmly into place Insert the versatile plastic base into the pole Align the holes of the pole with the holes of the plastic base 4 Secure the plastic base by inserting the screw and screwing it tightly into the holes of the plastic base and pole IMPORTANT The sensor should be positioned in an open area away from trees or other obstructions 5 Hammer pole cone end down into the ground at the desired spot until versatile plastic base is level with the ground TIP Place a block of wood between the pole and the hammer to prevent damage to the pole Assemble middle pole on top of the bottom one Using two screws fix it firmly into place Assemble top pole on top of the middle one Using two screws fix it firmly into place ot 10 Slide the vertical attachment bracket on top of the top pole 11 Using two screws fix it firmly into place To mount the temperature humidity sensor 12 Slide outdoor sensor onto vertical attachment bracket 13 Insert the wind vane into the attachment bracket 14 Screw aluminium pole firmly into place IMPORTANT For best results point the wind vane North Securing the assembled remote unit 15 Insert the 2 rectangular base legs through the holes
11. wind chill humidity and dew point alarms 1 Inthe Temperature or Humidity Area press ALARM repeatedly to toggle between high low alarms for temperature heat index wind chill humidity and dew point readings 2 Press and hold ALARM to enter the alarm setting Rotate the dial left or right to set the desired values 4 Press ALARM to confirm the setting a To activate deactivate the high low temperature heat index wind chill humidity and dew point alarms 1 Inthe Temperature or Humidity Area press ALARM repeatedly to select the desired alarm 2 Press MEMORY A ON OFF to activate or deactivate the alarm NOTE The dew point advises at what temperature condensation will form The wind chill factor is based on the combined effects of temperature and wind speed am Ww The trend lines are shown next to the temperature and humidity readings The trend is shown as follows RISING STEADY FALLING The Comfort Zone icon indicates how comfortable the climate is based on current temperature and humidity measurements a WIND DIRECTION SPEED AN e K The base station provides wind speed and wind direction information To read the wind direction find the compass point the Wis pointing to S The timestamp records the date and time when storing the wind speed readings To select the wind speed unit Press UNIT at the bottom of the base station to switch be
12. 100 g 3 53 oz without battery m s kph mph knots 2 m s 10 m s 3 m s 10 m s 56 m s 10 16 positions Approx every 14 seconds Max speed gust 2 x UM 3 AA 1 5V batteries 115 x 87 x 118 mm 4 5 x 3 4 x 4 6 inches 130 g 4 59 oz without battery C F 50 C to 70 C 58 F to 158 F SEE Operating range 30 C to 60 C 4 F to 140 F over it dry it immediately with a soft lint free cloth e Do not clean the unit with abrasive or corrosive Accuracy 20 C 0 C 2 C 4 0 F 0 C 40 C 1 C 2 0 F materials o 40 C 50 C 2 C 4 0 F no nor a with the unit s internal components R i This invalidates the warranty 50 C 60 C 3 C 6 0 F e Only use fresh batteries Do not mix new and old Comfort 20 C to 25 C 68 F to 77 F batteries Memory Current Min and Max temp e Images shown in this manual may differ from the Dew Point w Max and Min Wind chill temp and min actual display e When disposing of this product ensure it is collected separately for special treatment and not as household waste e Placement of this product on certain types of wood Displayed range 2 to 98 may result in damage to its finish for which Oregon Operating range 25 to 90 Scientific will not be responsible Consult the furniture manufacturer s care instructions for information Resolution 1 o o o e The contents of this manual may not be rep
13. ATHER ALARMS Weather alarms are used to alert you of certain weather conditions Once activated the alarm will go off when a certain criterion is met Alarms can be set for e Indoor and outdoor high low temperatures dew point and High Low humidity e High Heat Index e High Gust Wind e Low wind chill e High UV e Pressure drop e High rain rate See the relevant section for how to set the alarm To silence any alarm Press any button or rotate the dial SET UP SOFTWARE FIRST TIME USE The base station is capable of connecting to a PC computer using the USB connection The software can read the latest weather data collected from the base station PC system requirements The minimum system requirements for use of the software is e Operating system Microsoft Windows XP SP2 or Vista e Processor Pentium 4 or above e RAM Min 512MB e Hard disk free space Min 512MB e Screen Display Area 1024 x 768 pixels recommended For Windows XP users please go straight to Install Software section IMPORTANT You must follow the below instructions before installing software Determine status of UAC User Account Control 1 Click on AN Start 2 In context menu scroll to Settings and select Control Panel 3 Double click the User Account and Family Safety 4 Double click on Change your Windows password If you chose the Control Panel classic link from left hand column in step 2 skip thi
14. FICATIONS Dimensions LxWxH Weight Barometer unit Measuring range Accuracy Resolution Altitude setting Weather display Memory Temp unit Displayed range 143 x 89 x 165 mm 5 6 x 3 5 x 6 5 inches 300 g 10 58 oz without battery mb hPa inHg and mmHg 700 1050mb hPa 10 mb hPa 1mb 0 0 inHg Sea level User setting for compensation Sunny Partly Cloudy Cloudy Rainy and Snowy Historical data and bar chart for last 24hrs C F 0 C to 50 C 32 F to 122 F 14 Operating range Accuracy Comfort Memory Alarm Displayed range Operating range Resolution Accuracy Comfort Memory Alarm Synchronization Clock display Hour format Calendar Weekday in 5 languages Battery Dimensions LxWxH Weight Wind speed unit Speed accuracy Direction accuracy Transmission of wind speed signal Memory Battery Dimensions LxWxH Weight Temp unit Displayed range 30 C to 60 C 4 F to 140 F 0 C 40 C 1 C 2 0 F 40 C 50 C 2 C 4 0 F 20 C to 25 C 68 F to 77 F Current Min and Max temp Dew Point w Min and Max Hi Lo 2 to 98 25 to 90 1 25 40 7 40 80 5 80 90 7 40 to 70 Current Min and Max Hi Lo Auto or disabled HH MM SS 12hr AM PM or24hr DD MM or MM DD E G F I S am Ww 4 x UM 3 AA 1 5V batteries AC adapter 6V 178 x 76 x 214 mm 7 x 3 x 8 4 inches
15. MORY A ON OFF to activate or deactivate the alarm UVI BAROMETER RAINFALL The weather station works with one UV sensor and one rain gauge The station is capable of storing and displaying the hourly history data for the last 10 hours 11 z of UV index and 24 hours of rainfall and barometric pressure readings UVI BAROMETER RAINFALL ae 4 20 Sy E gt 2 4 gt 14 E 2 0 2 EE 2 EEE EE 6 Om me BEBO EEHEEHE 2 smm E E EENEN 2 EHEHEHEH os caseus Sgsass Seecsn 2 4 E ey ttt BEBE lt c EEHEHE lt O OBB EEE 24 le 6 3 I OHMmb 54 12 6 3 I OH in The bar chart display shows the current and historical data for the UV index barometric pressure and rainfall readings To view the UV Barometer Rainfall readings 1 Press SELECT to navigate to the UV Barometer Rainfall Area W will show next to the Area 2 Press MODE to toggle between UVI Barometer Rainfall readings The corresponding icon will appear 3 Rotate the dial left or right to view the historical data for the selected area The corresponding historical readings are showing NOTE The number shown in the HR icon indicates how long ago each measurement was taken e g 2 hours ago 3 hours ago etc am Ww To select the measurement unit for the barometer or rainfall readings In the UV Barometer Rainfall Area press UNIT at the bottom of the base station to switch between e Barometer Millimeters
16. age Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 16
17. ddddddddddddddd Ks ddd ETE kd x HI HEAT WIND Pio INDEX CHILL POINT Lo IRAIA MR aL ic ha ie N Bt m s kph mph knots NY AVERAGE MAX GUST y Ann KON we Cece LIGHT MODERATE ay STRONG STORM 9 E a8 vN0 8 6 4 20 UV BARO RAIN WR 2mm EEEE 20 ACCUM PAST Om BEB M e 1 6 i Lit at etd Re 2 MMM OO LOW MEDV HIEX HI 24 12 6 3 1 OHr mbin Ce 2 re Oem Hue gO E aes Gl RATE ALT 24hrs sma oO le us lt gt LOL In ONE av inHg OB BB lt c lt 0 l TIME STAMP Lt Li E pt T ICI Weather Forecast Area Temperature Heat Index Wind Chill Area Wind Speed Wind Direction Area UVI Barometer Rainfall Area Clock Alarm Calendar Moon Phase Area AC adapter icon displays when unplugged Low battery icon for base station Humidity Dew Point Area Temperature Heat Index Wind Chill Area EO NDPA on oo 0 A UON HEAT WIND Eo l NDEX CHILL O COON OD Temperature trend Wind Chill level temperature is showing Heat Index level temperature is showing HI LO temperature HI Heat Index and LO Wind Chill alarms are set Selected area icon Indoor Outdoor channel temperature and humidity is displayed MAX MIN temperature Outdoor sensor battery is low Temperature C F Wind Speed Wind Direction Area AT MAX GUST HI N v 150 AAAA 1 ARONA ARWN D lt lt E di cs m s kph mph knots Y NY LIGHT MODERATE 7 STRONG STORM S
18. erature measurement unit Press UNIT at the bottom of the base station to select C F NOTE The unit of all temperature related displays will be changed simultaneously To view temperature Current temperature Heat Index and Wind Chill 1 Press SELECT to navigate to the Temperature Area W will show next to the Area Rotate the dial left or right to select the channel Press MODE repeatedly to toggle between the different displays 4 Press MEMORY A ON OFF to select MAX MIN display j NOTE To view wind chill ensure channel 1 Q is selected To view humidity Humidity Dew point 1 Press SELECT to navigate to the Humidity Area W will show next to the Area 2 Rotate the dial left or right to select the channel 3 Press MODE repeatedly to toggle between the different displays 4 Press MEMORY A ON OFF to select MAX MIN display Data Area Channels Type of required located supported memory Current Indoor MAX Temperature Temperature and 1 10 MIN Heat Index outdoor MAX Wind Chill MIN Humidity Indoor ara sci MIN Humidity and 1 10 MAX Dew Point outdoor MIN The timestamp is displayed accordingly in the Clock Area 10 To clear the memories and timestamp for the temperature heat index wind chill humidity and dew point readings In the Temperature or Humidity Area press and hold MEMORY A ON OFF to clear the readings To change the high low temperature heat index
19. image next to your selection to confirm it is the correct model 4 Plug one end of the USB cable into the base station s USB port and the other end into the PC s USB port 5 Uploading will start immediately NOTE This product should be supplied by an identical USB port complying with the requirements of Limited Power Source To learn more about how to utilize the functions available on the software please refer to PC Software Manual EN o Z LL downloadable from the software webpage IMPORTANT You must first successfully install software to access the PC Software Manual 1 In the PC software homepage click on MENU located at the top right hand corner of software main webpage 2 Select HELP from drop down list This will redirect you to a new webpage Click on PC Software Manual SOFTWARE UPDATES As we continually strive for improvement the software will be updated from time to time If there is a new version the moment PC is connected to the internet a dialogue box informing of available software will appear 1 Click OK 2 After a few moments File Download Security Warning dialogue box will appear Click Run 3 In the Internet Explorer Security Warning click Run 4 Follow steps 3 7 from Install Software section BACKLIGHT Press any button or rotate the dial to activate the backlight J Press RESET to return to the default settings SPECI
20. ink when it is searching for a signal If the radio signal is weak it can take up to 24 hours to get a valid signal reception G O indicates the status of the clock reception signal MEANING Time is synchronized Receiving signal is strong Time is not synchronized Receiving signal is weak To enable and force a signal search disable the clock radio reception clock synchronization 1 Press SELECT to navigate to the Clock Calendar Alarm Area W will show next to the Area 2 Press and hold SEARCH G oO appears when it is enabled NOTE For best reception the base station should be placed on a flat non metallic surface near a window in an upper floor of your home The antenna should be placed away from electrical appliances and not be moved around when searching for a signal CLOCK CALENDAR To manually set the clock You only need to set the clock and calendar if you have disabled the clock radio reception 1 Press SELECT to navigate to the Clock Area W will show next to the Area 2 Press and hold MODE to change the clock setting The setting will blink 3 Rotate the dial left or right to decrease or increase the setting value 4 Press MODE to confirm 5 Repeat steps 1 to 5 to set the time zone offset hour 23 hours 12 24 hour format hour minute year date month format month date and weekday language NOTE If you enter 1 in the time zone setting this will give you you
21. nit ASSEMDIY cccccceeeeeeeeeeeeeeeeeeeeeeees 5 AS Alternative Set Up Remote Wind Sensor on 5 2 SF 1 x USB cable Existing PP ONG eriseeria i 6 gy PX Alternative Set Up Temperature Humidity ed Sensor Mounted Separately ccccccsssseeeeeseeees 7 Set Up Rain Gauge iwictdencdsasasachideamannnncsbasesecnceewuiss T Set Up Base Station aiiccsisscvennnncacccssnnccsdvcncscomnciesnnnce 8 Base SLU U ON eke daicecitcisidnnwnicntida adacenncensediediadeussiwsnnenias 8 q Change Display Setting 0 0 0ccceeceeeeeeeeeeee 8 1 x 6V adapter Clock RECO DON cisiiiisisrisiini nnns suin annannati 8 Clock Calendar s ccvccesssstsccsceccsessiserdernmeccovieeiniieils 9 l o Clock Alari eners aE 9 1 x Base Station a Moon Phase sess ciiscaccacdetaciicncocnsnsanttsidunseceeccscandecceeneecess 9 4 x AA UM 3 1 5V Auto Scanning Fun ction ccccsseeesssseeeseeeeeeeeeees 9 batteries Weather Forecast aati cnissnicwnsiccicence ddceccnencensdccdunsnncccitaies 9 Temperature and Humidity ceeeeeeeeeeeeeeeees 10 Temperature and Humidity Trend 08 10 Comfort LCV Cl nt22235 05ccsesnscnsaseccdeduncseaaceaseddcosaabecases 10 Wind Direction Speed cccceeeeeeeeeeeeeneeeseees 10 UVI Barometer Rainfall eeeeeeessseeeeeeeeeees 11 II TG OX EEEE E 11 BAN OMG UCN sisccaccciccecensesiavchedusserescmedtietancescceuecat vedere 12 o Raini alleeneienaar eases 12 Weather Alarms
22. r regional time plus 1 hour If you are in the US WMR100NA only set the clock to O for Pacific time 1 for Mountain time 2 for Central time 3 for Eastern time NOTE The weekday is available in English German French Italian or Spanish To change the clock display 1 Press SELECT to navigate to the Clock Area W will show next to the Area 2 Press MODE to toggle between e Clock with Seconds e Clock with Weekday e Calendar CLOCK ALARM The clock has 2 alarms that can be set to sound with a beep ICON MEANING I i ta Alarm 1 or 2 is displayed gt Alarm 1 or 2 is activated No icons No alarm is set To set an alarm 1 Press SELECT to navigate to the Clock Area W will show next to the Area 2 Press ALARM to toggle between alarm 1 9 and alarm 2 8 display 3 When you ve selected the alarm you wish to change press and hold ALARM The alarm setting will blink 4 Rotate the dial left or right to change the setting 5 Press ALARM to confirm z To activate deactivate an alarm 1 Press SELECT to navigate to the Clock Area W will show next to the Area 2 Press ALARM to toggle between alarm 1 ce and alarm 2 s 3 Press MEMORY A ON OFF to activate or deactivate the alarm Y or appears when the alarm is activated MOON PHASE The Calendar must be set for this feature to work see Clock Calendar section Full Moon Waning Gibbous Third quarter Waning Crescen
23. racket Bracket 1 x Bottom Pole 1 x Mid Pole 1x Top Pole 0 2 x Round 2 x Rectangular 3 x Eye pins U bolts Base Legs li bed 1 x Versatile Base Wall or Ground Fixable ACCESSORIES SENSORS This product can work with up to 10 sensors at any one time to capture outdoor temperature relative humidity or UV readings in various locations Optional wireless remote sensors such as those listed below can be purchased separately For more information please contact your local retailer e Solar Panel STC800 connectable to Wind Sensor and Temperature humidity sensor e Thermo hygro THGR800 3 Ch e Thermo hygro THGR810 10 Ch e UV UVN800 Features and accessories will not be available in all countries OVERVIEW iP MEMORY A ON OFF Read the max min memory record Activate deactivate alarms 2 ALARM View and set alarms for barometer temperature humidity rainfall and wind speed 3 MODE Switch between the different display modes settings 4 Rotating dial Rotate left or right to increase or decrease the values of the selected reading 5 SELECT Switch between the different areas ae Se ee el ee oe eS AC adapter socket RESET Returns unit to default settings SEARCH Searches for sensors or for the radio controlled clock signal UNIT Selects unit of measurement Battery compartment WMR100N only EU UK radio signal USB connector Xdddddd a OOOO OK ddd zj ddddd
24. roduced Accuracy 25 40 T without the permission of the manufacturer 40 80 5 Do not dispose old batteries as unsorted municipal 80 90 7 waste Collection of such waste separately for special Comfort 40 to 70 treatment is necessary Memory Current Min and Max e Please note uve some units ale equipped with a battery safety strip Remove the strip from the battery Battery 2 x UM 4 AAA 1 5V batteries compartment before first use NOTE The technical specifications for this product and RF frequency 433MHz the contents of the user manual are subject to change without notice Range Up to 100 meters 328 feet with Transmission No of Channel Dimensions 114 x 114 x 145 mm y pare department directly please visit www2 oregonscientific L xW x H 4 5 x 4 5 x 5 7 inches com service support asp Weight 241 g 8 50 oz Ibs without battery For international inquiries please visit www2 Rainfall unit Mm hr and in hr oregonscientific com about international asp Range 0 mm hr 9999 mm hr Resolution 1 mm hr EU DECLARATION OF CONFORMITY Accuracy lt 15 mm hr 1mm Hereby Oregon Scientific declares that this Advanced Weather Station with Wireless Sensor Set amp Mounting 79 1o mm So maimik E ae Package models WMR100N WMR100NA is in Memory Past 24hrs hourly and compliance with the essential requirements and other accumulated relevant provisions of Directive 1999 5 EC A copy of the from last memory reset
25. s ensure Sleep Mode on computer is disabled 1 Right click on Desktop 2 In context menu click on Properties 3 Click on Screen Saver tab in the Display Properties dialogue box 4 Click on Power located at the bottom half of dialogue box 13 5 In new dialogue box Power Options Properties click on Power Schemes tab 6 In Settings for Timers off Presentation power scheme section under System Standby option choose Never in drop down list 7 Click Apply and then click OK 8 Previous window will return Click OK to confirm and exit 1 Right click on Desktop 2 In context menu click on Personalize 3 Click on Screen Saver link in the Personalize appearance and sounds dialogue box 4 Click on Change Power Settings located at the bottom half of window 5 Select High Performance and click Change plan settings link 6 Click Change advanced power settings link 7 Click on next to Sleep in sub menu click on next to Hibernate after 8 Click Setting link and select Never in drop down list 9 Click Apply and then OK UPLOAD DATA TO PC SOFTWARE NOTE The USB is only used for uploading weather data It cannot be used for charging battery power 1 After successful installation double click on desktop shortcut 2 Click Display in Oregon Weather Station dialogue box 3 You will be prompted to select model number Please select your model in the drop down list and refer to the
26. s step 5 In Turn User Account On or Off screen identify if UAC option is enabled on ticked or disabled off un ticked NOTE We highly recommend disabling this option for seamless operation of the Weather OS software To Turn User Account Off 6 Deselect the UAC option by un ticking the box click once 7 Click OK 8 In You must restart your computer dialogue box click Restart now 1 Insert provided CD into disk drive 2 Run CD software 3 Setup Wizard dialogue box will appear and guide you through the installation process If you have Windows Vista and User Account Control is ON ticked i In Select Installation Folder dialogue box next to Folder text box C Program Files Oregon Scientific Weather OS click Browse ii To select a new location to save the program select C Users admin Or click C Drive subfolder Users subfolder admin iii Click on jg Create New Folder icon iv Type OS Weather and click OK v In User Account Control dialogue box click Allow i Continue with installation process 4 During installation Microsoft Visual C Redistributable Setup dialogue box may appear Select Repair and click Next 5 Once Setup has been successfully completed click Finish then Close 6 After successful installation double click on G desktop shortcut 7 Click Display in Oregon Weather Station dialogue box lt DISABLE SLEEP MODE To allow for continuous data update
27. t AUTO SCANNING FUNCTION To activate the outdoor temperature and humidity auto scan function 1 Press SELECT to navigate to the Temperature or Humidity Area W will show next to the Area 2 Press and hold MODE to activate auto scan The temperature and humidity display will scroll from indoor to ch1 through to ch10 3 Press MEMORY A ON OFF or MODE or ALARM to stop the auto scan am Ww NOTE Channel 1 is used for the outdoor temperature and humidity sensor Additional temperature and humidity sensors can use other channels WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 50 km 19 31 mile radius Weather Forecast Area ICON DESCRIPTION We Ji A AS Sunny ry yn wy I o FNS Partly cloud a AS Cloudy ina I D Rainy f a C r Snowy SEE LL TEMPERATURE AND HUMIDITY The weather station displays indoor and outdoor readings for 1 Current minimum and maximum temperatures and relative humidity 2 Comfort level indicator and trend line 3 Heat index wind chill and dew point level The weather station can connect up to 10 remote sensors NOTE Channel 1 is dedicated for outdoor temperature and humidity shows which remote sensor s data you are viewing A appears when indoor data is displayed The timestamp records the date and time when storing the temperature and humidity readings in memory To select the temp
28. tery compartment 3 RESET button O a AO N Dew point level Temperature is showing HI LO humidity and Dew Point alarms are set Comfort levels Humidity trend MAX MIN humidity Humidity reading D oe ONS 1 Funnel 2 Indicator Temperature humidity sensor casing Solar power socket RESET button Battery compartment a N a GETTING STARTED The wind sensor takes wind speed and direction readings The sensor is battery operated It is capable of transmitting data to the base station wirelessly within an approximate operating range of 100 meters 328 feet IMPORTANT Ensure that the wind sensor is pointing North to enable it to record accurate readings NOTE The sensor should be positioned in an open area away from trees or other obstructions To insert batteries 1 Unscrew the anemometer from the wind sensor carefully 2 Insert batteries matching the polarities and replace the anemometer Press RESET after each battery change 3 Slide wind vane onto the end of the plastic attachment located on the aluminium pole NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing 1 Holding sensor twist and click to the left 2 Pull sensor away from casing 3 Insert batteries matching the polarities Press RESET after each battery change 4 Insert sensor into the casing twist and click
29. tor A may appear in the following areas AREA MEANING Battery in the base station is low will show when AC adapter is disconnected Weather Forecast Area The displayed channel indicates the outdoor sensor for which battery is low Temperature Heat Index Wind Chill Area Wind Speed Wind Direction Area Battery in the wind sensor is low UVI Barometer Rainfall Area Battery in the UV Rain sensor is low BASE STATION To change the display and settings use the following buttons on the rotating dial SELECT MEMORY A ON OFF MODE and ALARM In addition the UNIT and SEARCH buttons located at the bottom of the base station allows pre setting of the remote sensor channels and the measurement units for display TIP To exit from the setting mode push any button Alternatively the base station will automatically exit after 30 seconds CLOCK RECEPTION This product is designed to synchronize its calendar clock automatically once it is brought within range of a radio signal WMRT100N e EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany e UK MSF 60 signal within 1500 km 932 miles of Anthorn England WMR100NA e WWVB 60 signal within 3200km 2000 miles of Fort Collins Colorado WMR100N only slide the EU UK switch to the appropriate setting based on your location Press RESET whenever you change the selected setting The reception icon will bl
30. tween e Metres per second m s Tt Sa Sa Sa gt SD Gp lt gt e Kilometers per hour kph m D a A e Miles per hour mph m s kph mph knots e Knots knots The wind level is shown by a series of icons ICON y N A y Light LEVEL DESCRIPTION lt 2 mph lt 4km h 2 8 mph 3 13 km h Moderate 9 25 mph 14 41 km h Strong 26 54 mph 42 87 km h G Storm gt 55 mph gt 88 km h To display the AVERAGE and GUST wind 1 Press SELECT to navigate to the Wind Speed and Wind Direction Area W will show next to the Area 2 Press MODE to toggle between AVERAGE and GUST wind readings To display the maximum speed and direction for gust wind In the Wind Speed and Wind Direction Area press MEMORY A ON OFF to toggle between wind speed MAX GUST wind readings The timestamp is displayed accordingly in the Clock Area To clear the memories and timestamp for the wind readings In the Wind Speed and Wind Direction Area press and hold MEMORY A ON OFF to clear the readings To change the high gust wind speed alarm 1 In the Wind Speed and Wind Direction Area press and hold ALARM to enter the high gust wind alarm setting 2 Rotate the dial left or right to set the desired values 3 Press ALARM to confirm the settings To activate deactivate the high gust wind speed alarm 1 In the Wind Speed and Wind Direction Area press ALARM repeatedly to select the desired alarm 2 Press ME