Home

Omron rs2 User's Manual

image

Contents

1. Notes If the battery low symbol x4 appears on the display turn off the unit then replace both batteries at the same time The measurement values continue to be stored in memory even after the batteries are replaced Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries 3 Using the Unit 3 1 Applying the Wrist Cuff Do not apply over clothing 1 Place the wrist cuff over your wrist Your palm should face upward 2 Wrap the wrist cuff around your wrist Wrap the wrist cuff securely around the wrist for taking accurate measurements Make sure that the wrist cuff does not cover the protruding part of the wrist bone ulna on the outside of the wrist Note You can take a measurement on either your left or right wrist 3 2 How to Sit Correctly To take a measurement you need to be relaxed and comfortably seated under comfortable room temperature No bathing drinking alcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your feet flat on the floor Sit upright with your back straight The cuff should be at the same level as your heart Relax your wrist and hand Do not bend your wrist back clench your fist or bend your wrist forward 3 3 Taking a Reading Notes To cancel a measurement press the START STOP button at any time during m
2. the monitor will delete the oldest readings To View the Readings Stored in Memory 1 Press the amp button The Memory number appears for a second before the pulse rate is displayed The newest set is numbered 1 Note If there are no measurements results stored in the memory the screen to the right is displayed 2 Press the amp button repeatedly to view the readings stored in memory To Delete All the Values Stored in Memory When the memory symbol amp appears first press the amp button Then while holding it down press the START STOP button simultaneously for about 2 3 seconds E4 START START _ STOP D First Second Note You cannot partially delete the stored readings 4 Troubleshooting and Maintenance 4 1 The Icons and Error Messages Error Display Cause Remedy Irregular heartbeats are detected Remove the wrist cuff Wait 2 3 minutes and then take another measurement Repeat the steps in section 3 3 If this error continues to appear contact your doctor The batteries are low You should replace them with new ones ahead of time Refer to section 2 1 The batteries are exhausted You should replace them with new ones at once Refer to section 2 1 Wrist cuff not applied correctly Apply the wrist cuff correctly Refer to section 3 1 EJ E4 Movement during measurement Repeat Measurement
3. Inflation Deflation Memory Power Source Battery Life Applied Part Protection Against Electric Shock Wrist Blood Pressure Monitor OMRON RS2 HEM 6121 E LCD Digital Display Oscillometric method Pressure 0 to 299 mmHg Pulse 40 to 180 min Pressure 3 mmHg Pulse 5 of display reading Automatic inflation by pump Automatic rapid deflation 30 Measurements 2 AAA alkaline LRO3 batteries 1 5V Approx 300 measurements with new alkaline batteries at a room temperature of 23 C Type B Internally powered ME equipment Operating temperature 10 to 40 C Maximum 30 to 85 RH Humidity Storage temperature 20 to 60 C Maximum 10 to 95 RH Blood pressure readings constantly vary with time of day and how relaxed you are Take several deep breaths and try to remain relaxed before taking a measurement The blood pressure is different each time The reading is extremely low or high The unit loses power during measurement Replace the batteries with new ones Refer to section 2 1 The batteries are exhausted Nothing happens when you press the buttons The batteries have Insert the batteries with been inserted the correct polarity incorrectly Refer to section 2 1 Press the START STOP button and repeat measurement If the problem continues try replacing the batteries with new ones If this still does not solve the problem contact your
4. authorised OMRON dealer or the OMRON Customer Service at the address given on the packaging or attached literature 700 to 1060hPa Approximately 101g without batteries Approximately 78 w mm x 60 h mm x 21 d mm without the wrist cuff Humidity Console Weight Outer Dimensions Measurable Approximately 13 5 to 21 5 cm circumference Cuff Material Nylon and polyester Package Content Main unit storage case battery set instruction manual guarantee card Note Subject to technical modification without prior notice C 0197 This device fulfils the provisions of EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European Standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co Ltd Japan The Core component for OMRON blood pressure monitors which is the Pressure Sensor is produced in Japan Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially
5. unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 2007 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the e
6. while remaining still and refraining from talking during the measurement Refer to section 3 3 ES Wrist cuff not applied correctly or movement during measurement Apply the wrist cuff correctly and repeat measurement while remaining still and refraining from talking during the measurement Refer to section 3 1 and 3 3 Er Device error Contact your OMRON retail outlet or distributor Note The irregular heartbeat symbol may also be displayed with error messages 4 2 Troubleshooting Problem Cause Remedy Measure while in the correct posture Refer to section 3 2 The wrist cuff is not at heart level The cuff is not wrapped snugly around the wrist Wrap the cuff correctly The reading is Refer to section 3 1 extremely low The arms and shoulders are tense or high Relax and try taking the measurement again Refer to section 3 3 Movement or talking during measurement Remain still and do not talk during Measurement Refer to section 3 3 Wrist cuff pressure Air is leaking from does not rise the wrist cuff Consult your OMRON retail outlet or distributor Apply the cuff correctly so that it is firmly wrapped around the wrist Refer to section 3 1 Wrist cuff deflates too soon The wrist cuff is loose 5 Technical Data Product Description Model Display Measurement Method Measurement Range Accuracy
7. OMRON retail outlet or distributor Other problems 4 3 Maintenance To protect your unit from damage please observe the following e Do not subject the main unit and the cuff to extreme temperatures humidity moisture or direct sunlight e Do not disassemble the unit Do not subject the unit to strong shocks or vibrations for example dropping the unit on the floor e Do not use volatile liquids to clean the main unit e Do not wash the cuff or immerse it in water e Do not use petrol thinners or similar solvents to clean the cuff e Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging e The unit should be cleaned with a soft dry cloth e Use a soft moistened cloth and soap to clean the cuff Keep the unit in its storage case when not in use Fold the cuff into the storage case Do not store the unit in the following situations lf the unit is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours Locations exposed to vibrations shocks or where it will be at an angle Calibration and Service e The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy Please consult your
8. Wrist Blood Pressure Monitor Model RS2 Instruction Manual IM HEM 6121 E 02 01 2013 5338844 7B Introduction Thank you for purchasing the OMRON RS2 Wrist Blood Pressure Monitor The OMRON RS2 is a compact and easy to use blood pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly For comfortable controlled inflation without the need of pressure pre setting or re inflation the device uses its advanced IntelliSense technology Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff following the instructions in this instruction manual It is mainly designed for general household use Please read the Important Safety Information in this instruction manual before using the unit Cl Please read this instruction manual thoroughly before using the unit Please keep for future reference For specific information about your own blood pressure CONSULT YOUR DOCTOR Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis Please read this section carefully before using the unit A Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury General Usage Always consult your doctor Self diagnosis of measurement results and self t
9. easurement Remain still while taking a measurement 1 Press the START STOP button All the symbols appear on the display The wrist cuff will start to inflate automatically START AINFLATE ADEFLATE ACOMPLETE Cuff Wrapping Guide The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the wrist Even when the Q is displayed a blood pressure reading will be taken Note This reading is NOT reliable due to the incorrect wrapping of the cuff Please wrap the cuff again taking care to wrap it correctly and take the measurement again When the is displayed the cuff is correctly wrapped tightly enough on the wrist and the reading is accurate and reliable 2 Undo the wrist cuff and remove the unit 3 Press the START STOP button to turn off the monitor The monitor automatically stores the measurement in its memory It will automatically turn off after two minutes Important If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measurement result is displayed Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg This criteria is for home blood pressure measurement Your blood pressure monitor includes an irr
10. egular heartbeat feature Irregular heartbeats can influence the results of the measurement The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol If the irregular heartbeats cause the measurement to be invalid no result is shown If the irregular heartbeat symbol is shown after you have taken a measurement repeat the measurement If the irregular heartbeat symbol is shown frequently please make your doctor aware of it Notes Wait 2 3 minutes before taking another blood pressure measurement Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different OMRON recommends to always use the same arm for measurement If the values between the two arms differ substantially please check with your physician which arm to use for your measurement A Warning Self diagnosis of measured results and treatment are dangerous Please follow the instructions of your doctor 3 4 Using the Memory Function The unit automatically stores up to 30 sets of measurement values blood pressure and pulse rate If the memory is full
11. nd vibrations to or drop the unit Do not take measurements after bathing drinking alcohol or caffeine smoking exercising or eating Do not inflate the wrist cuff when it is not wrapped around your wrist Read and follow the Important information regarding Electro Magnetic Compatibility EMC in the Technical Data Section Read and follow the Correct Disposal of This Product in the Technical Data Section when disposing of the device and any used accessories or optional parts Q 1 Overview Main unit A Wrist cuff D Memory E button B Battery compartment E START STOP button C Display Display Systolic blood pressure Diastolic blood pressure K Irregular heartbeat symbol Heartbeat symbol L Cuff wrapping guide 1 Flashes during measurement M Deflation symbol 2 If flashing after measurement N Battery low symbol completed or when viewing results stored in the memory indicates blood pressure out of recommended range I Pulse display and Memory number J Memory symbol roan Note If your systolic or diastolic pressure is outside the standard range above 135 85 mmHg the Heartbeat symbol 49 will blink Please refer to Section 3 3 2 Preparation 2 1 Installing Replacing the Batteries 1 Remove the battery cover 2 Insert two 1 5V AAA alkaline LRO3 batteries as indicated in the battery compartment and then replace the battery cover
12. nvironment or human health from uncontrolled waste disposal please separate this product from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can return this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Manufacturer eal EU representative Production facility OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS www omron healthcare com OMRON DALIAN CO LTD Dalian CHINA OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANT FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Made in China Subsidiary
13. reatment are dangerous People with severe blood flow problems or blood disorders should consult a doctor before using the unit as cuff inflation can cause internal bleeding Battery Usage If battery fluid should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately A Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property General Usage Do not leave the unit unattended with infants or persons who cannot express their consent Do not use the unit for any purpose other than measuring blood pressure Do not use a mobile phone or other devices that emit electromagnetic fields near the unit This may result in incorrect operation of the unit Do not disassemble the unit or wrist cuff Do not operate the unit in a moving vehicle car airplane Battery Usage If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Use only two AAA alkaline LRO3 batteries with this unit Do not insert the batteries with their polarities incorrectly aligned Replace old batteries with new ones immediately Replace both batteries at the same time Remove the batteries if the unit will not be used for three months or more Do not use new and used batteries together eneral Precautions Do not apply strong shocks a

Download Pdf Manuals

image

Related Search

Related Contents

Section 1 - Emerson Network Power  7405 E & H Near Field Probe Set - ETS  ラスターパネル・ラスターボード ラスターバーモジュール  Manual de Instalaçao POWERMAX X DC Indoor  Philips RI2081/01 blender    AUTORESPONDER UNLIMITED 2.0 User`s Guide  Tangent Duo Clock Radio - Black  Manual de usuario  Affiche Bébé mode d`emploi Calais 13.11.14  