Home

Omron M1 Plus User's Manual

image

Contents

1. Press the I O button to turn the unit on All items in the display will be displayed briefly The battery symbol will also be displayed for test purposes This does not mean the batteries are empty The current date is displayed and the deflation symbol will flash Finally the heartbeat symbol will appear and the current time and 0 is displayed Note If the deflation symbol does not disappear soon press the air release button to release any air in the arm cuff Pump the inflation bulb to inflate the arm cuff 1 Inflate the cuff until it is 30 to 40 2 A mmHg above your expected systolic blood pressure value ex If your expected blood pressure is around 140mmHog inflate the arm cuff to between 170 and 180 mmHg Inflate the cuff rapidly so that the pressure is reached in about five seconds When the desired pressure has been achieved release the inflation bulb Remain still and do not talk 3 Using the Unit e The current time continues to be displayed while the cuff is being inflated Note Do not inflate the arm cuff more than necessary Measurement starts Measurement starts automatically after you stop inflating the arm cuff Decreasing numbers appear on the display and the heartbeat symbol flashes Remain still and do not talk during measurement During measurement the buzzer if set to on will beep in rhythm with your heartbeat Note To cancel a measurement
2. Manual Inflation Blood Pressure Monitor Model M1 Plus e Instruction Manual e Mode d emploi e Gebrauchsanweisung e Manuale di istruzioni e Manual de instrucciones e Gebruiksaanwijzing e PYKOBOACTBO NO KCNNYATAUNN e Instrukcja PL e Kezel si tmutat HU ALl for Healthcare IM HEM 4011C E 03 10 2011 1649533 0C Contents o AAA 3 Important Safety Information ooocccccconnninccononcnannnnnnnnaannnnnnnns 4 Es OM OIE W sudoracion toads E a Eaa Naaa 5 Zi Preparato a ae iaaea a taea aa Aaaa aaia aidaa drpd adas adan 8 2 1 Installing Replacing the Batteries ooooocccccccoommo 8 2 2 Setting the Date and Time ooccccccnncccccncncnnocnnnnnnnnnanonoss 10 2 3 Adjusting the Settings MOdeS ccccccsseeeeeeeeeeeeeeeees 13 Ja USING Me Ud a a 14 3 1 How to Sit Correctly When Taking a Measurement 14 3 2 Applying the Arm Cuff oiei nean iania ainai 16 9 9 FAKING a Reca sanidad 18 3 4 Using the Memory Function ccccocccccccncccccnnnccncnnncccnnnncnos 23 4 Quick Reference Guide ccccccccssssssseseeeeeeeeeeeeeenseees 26 5 Handling Errors and Problems ccccceeeeeeeeeeeeeeeeenes 27 del Eror MESSAGES mentada 27 52 Troubleshooting oi 29 6 Maintenance and Storage ccccessseceeeessseeeeeeeeeeeneeeeeees 31 1 Optional Parts suso coito a 34 9 Technical Data da stays 35 9 Some Useful Information about Blood Pressure 37 Introduction Than
3. 3 minutes before taking another blood pressure measurement 5 Handling Errors and Problems 5 1 Error Messages Press air release button and restart the measurement with a higher inflation level Carefully read steps under section 3 3 Cuff is under inflated Repeat measurement Remain Movement during still and do not talk during measurement measurement Refer to section 3 3 Insert the air tube securely Air tube disconnected Refer to section 3 2 Arm cuff not applied Apply the arm cuff correctly correctly Refer to section 3 2 Clothing is interfering o one interfering with the arm cuff Refer to section 3 2 Air is leaking from the Replace cuff with new one arm cuff Refer to Chapter 7 Release your hand from the air The arm cuff was inflated inflation bulb before the pressure above 299 mmHg reaches 299 mmHg Refer to section 3 3 Replace all four AAA batteries Battery power is low with new ones Refer to section 2 1 Blinks or appears continuously 5 Handling Errors and Problems E Contact your OMRON retail outlet oc 5 Device error or distributor Refer to Chapter 8 Press the inflation bulb to inflate the arm cuff until the reinflation symbol goes out Or deflate the Pressure is too low arm cuff and repeat measurement after checking that the heartbeat symbol has been displayed Refer to section 3 3 Note The irregular heartbeat symbol may also be displayed with error mess
4. HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 ODG U K OMRON MEDIZINTECHNIK Subsidiary HANDELSGESELLSCHAFT mbH John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANTE FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Made in China 39
5. push the I O button to turn off the monitor 2 3 2 Preparation Adjusting the Settings Modes You can modify the options for the various settings of your unit This is done by pressing the SET button to select a setting then pressing the MEMORY button to select the options for that setting After selecting a setting press the I O button to confirm the setting and turn the power off Buzzer Mode When Buzzer mode is on the unit emits sounds during measurement to indicate that pulse waves are detected and when measurement is complete Press the SET button once while the unit is in standby mode The buzzer symbol appears on the display Press the MEMORY button to select on or off The setting alternates between on and off with each press of the MEMORY button The default setting is on When you have selected the desired setting press the I O button to turn the unit off Notes e If you want to adjust the date or time press the SET button after setting the buzzer setting follow steps for setting date and time Refer to 2 2 press the I O button to turn the unit off e If you forget to turn the unit off it will automatically shut itself off after five minutes 13 3 Using the Unit 3 1 14 How to Sit Correctly When Taking a Measurement You can take a measurement on either your left or right arm Note e Measurements should be taken in a quiet place a
6. used batteries should be carried out in accordance with the national regulations for the disposal of electronic products BR wee CE0197 This device fulfils the previsions of EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European Standard EN1060 Non invasive sohygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems liJCaution Please read the instruction manual carefully before using the device 35 8 Technical Data Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON Healthcare conforms to this EN60601 1 2 2001 standard for both i
7. you forget to turn the unit off it will automatically shut itself off after five minutes 20 3 Using the Unit Important e If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measurement result is displayed Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg This criteria is for home blood pressure measurement For professional office blood pressure measurement criteria please refer to Chapter 9 Some Useful Information about Blood Pressure e Your blood pressure monitor includes an irregular heartbeat feature Irregular heartbeats can influence the results of the measurement The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol O If the irregular heartbeats cause the measurement to be invalid no result is shown If the irregular heartbeat symbol O is shown after your have taken a measurement repeat the measurement If the irregular heartbeat symbol D is shown frequently please make your doctor aware of it ar ay Bp FI 7 a i e ca mu Vaad Ca
8. ages 28 5 2 Troubleshooting The reading is extremely low or high Arm cuff pressure does not rise Arm cuff deflates too soon Cannot measure or readings are too low or too high The unit loses power during measurement Arm cuff not applied correctly Movement or talking during measurement Clothing is interfering with the arm cuff Is the air tube securely connected into the main unit Air is leaking from the arm cuff The arm cuff is loose Has the arm cuff been inflated sufficiently Is the air release button being pressed during inflation The batteries are empty 5 Handling Errors and Problems Apply the arm cuff correctly Refer to section 3 2 Remain still and do not talk during measurement Refer to section 3 3 Remove any clothing interfering with the arm cuff Refer to section 3 1 Make sure that the air tube is connected securely Refer to section 3 2 Replace the arm cuff with a new one Refer to Chapter 7 Apply the cuff correctly so that it is firmly wrapped around the arm Refer to section 3 2 Inflate the cuff so that it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3 Be careful not to press the air release button during measurement Replace the batteries with new ones Refer to section 2 1 29 5 Handling Errors and Problems 30 Nothing happens when you press the buttons Other pro
9. anese or alkaline batteries with this unit Do not use other types of batteries e When using batteries the battery liquid may leak and damage the main unit e Please observe the following points Do not insert the batteries with their polarities incorrectly aligned Replace old batteries with new ones immediately When you are not going to use the unit for a long period of time approximately three months or more take out the batteries Do not use new and used batteries together Do not use batteries of a different type together e Do not forcibly bend the arm cuff or bend the air tube excessively e When removing the air tube pull on the edge of the tube at the connection with the main unit not the middle of the tube e Do not inflate the arm cuff when it is not wrapped around your arm 1 Overview Main unit Display F Battery compartment SET button Air connector MEMORY button I O button MOO gt 1 Overview Arm Cuff G Arm cuff Medium cuff arm circumference 22 32 cm H Air Tube If air starts to leak from the arm cuff please replace with a new one Refer to Chapter 7 Optional Parts Inflation Bulb CN O Air Release Button J Air Tube K Air Inflation Bulb 1 Overview Display Wo hi Ey PA 2 Ola L Systolic blood pressure R Heartbeat symbol M Diastolic blood pressure 1 Flashes during measureme
10. average value will be based on any measurements taken after the date and time were reset However you can still view the readings stored in memory e Please note that all measurements are stored in the memory If different people measure with the same device make sure that you are aware of this fact 25 4 26 4 Press the I O button to turn the unit on then Quick Reference Guide Use this as a quick reference guide only If you are using this device for the first time please read carefully Chapter 3 of this Instruction Manual To help ensure a reliable reading avoid eating smoking or exercising for at least 30 minutes before taking a measurement Note Remove any tight fitting clothing from your upper arm Sit on a chair with your feet flat on the floor and place your arm on a table so that the arm cuff will be at the same level as your heart 2 Apply the arm cuff to your upper arm The coloured marker should be centred on the inside of your arm and point down the inside of the arm so that the air tube runs down the inside of your forearm and is in line with your middle finger 3 Secure the cuff around your arm using the fabric fastener strip pump the inflation bulb to inflate the cuff After measurement is complete and the measurement results are displayed press the air release button to release any air in the cuff 5 Press the I O button to turn the unit off Note Always wait at least 2
11. blems Replace the batteries with The batteries are empty New ones Refer to section 2 1 Insert the batteries with the correct polarity Refer to section 2 1 The batteries have been inserted incorrectly Press the I O button and repeat measurement If the problem continues try replacing the batteries with new ones If this still does not solve the problem contact your OMRON retail outlet or distributor 6 Maintenance and Storage Maintenance To protect your unit from damage please observe the following e Do not subject the main unit and cuff to extreme temperatures humidity moisture or direct sunlight e Do not fold the cuff or tubing tightly e Do not inflate the arm cuff over 299 mmHg e Do not disassemble the unit e Do not subject the unit to strong shocks or vibrations for example dropping the unit on the floor Do not use volatile liquids to clean the main unit The unit should be cleaned with a soft dry cloth e Use a soft moistened cloth and soap to clean the arm cuff e Do not wash the arm cuff or immerse it in water Do not use petrol thinners or similar solvents to clean the arm E Mi e Do not carry out repairs ee any kind Wout If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging 31 6 Maintenance and Storage Calibration and Service e The accuracy of this blood pressure monitor has been careful
12. blood pressure written as 135 85 is referred to as 135 over 85 mmHg 37 9 Some Useful Information about Blood Pressure 38 200 Upper curve systolic blood pressure Lower curve diastolic blood pressure 150 F D E E E Na HA A 50 F T T T T 6 12 18 24 Time of day Example fluctuation within a day male 35 years ola Classification of Blood Pressure by the World Heath Organization The World Health Organization WHO and the International Society of Hypertension ISH developed the Blood Pressure Classification shown in this figure Systolic blood pressure mmHg Severe hypertension 180 Moderate hypertension 160 Mild hypertension 140 Normal systolic value 130 Normal blood pressure 120 Optimal blood pressure Diastolic target value blood pressure 80 85 90 100 110 mmHg This classification is based on the blood pressure values measured on people in a sitting position in outpatient departments of hospitals There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotensive 9 Some Useful Information about Blood Pressure Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN EU representative OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS REP www omron healthcare com Production facility ee CO LTD alian OMRON
13. co 21 3 Using the Unit 22 What is Irregular Heartbeat An irregular heartbeat is a Normal Heartbeat heartbeat rhythm that varies Pulse f ff AA by more than 25 from the average heartbeat rhythm Blood pressure ANININ detected while the unit is Irregular Heartbeat measuring the systolic and Short Long diastolic blood pressure Pulse If such an irregular rhythm is SINN detected more than twice e during measurement the irregular heartbeat symbol O appears on the symbol when the measurement results are displayed What is Arrhythmia A heartbeat is stimulated by electrical signals that cause the heart to contract Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio electrical system that drives the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination Whether the appearance of the irregular heartbeat symbol O in the results indicates arrhythmia or not can only be determined by an examination and diagnosis by your doctor If the irregular heartbeat symbol is shown frequently please make your doctor aware of it Conducting self diagnosis and treatment based on measurement results is dangerous Be sure to
14. e taking a measurement for the first time If the batteries have been removed for more than 30 seconds the date and time setting will need to be reset When the I O button is pressed to turn the unit on for the first time after inserting batteries the year digits 2005 will flash on the display Press the MEMORY button to advance the digits one ata time Notes e The range for the year setting is 2005 to 2030 If the year reaches 2030 it will return to 2005 e If you hold down the MEMORY button the digits will advance rapidly 2 Preparation Press the SET button to confirm the setting when the desired number appears on the display The year is set and the month digits flash on the display Repeat steps 2 and 3 to set the month The month is set and the day digits flash on the display Repeat steps 2 and 3 to set the day The day is set and the hour digits flash on the display Repeat steps 2 and 3 to set the hour The hour is set and the minutes digits flash on the display 11 2 Preparation 12 if the minutes a The minutes settings is set The unit automatically switches to standby mode after the minute setting has been set To adjust the date and time press the SET button twice while the monitor is in standby mode Notes e After the buzzer setup is completed the time date setting will flash on the display e After each setup is completed please
15. follow the instructions of your doctor 3 4 3 Using the Unit Using the Memory Function This unit has a memory capable of storing 21 sets of readings Every time you complete the measurement the unit automatically stores the blood pressure and pulse rate If there are three readings within 10 minutes of the last reading the average of the three readings is displayed If there are only two readings in memory for that period the average will be based on two readings If there is only one reading in memory for that period that reading will be displayed as the average value Note When 21 sets of readings are stored in memory the oldest set will be deleted to store a new set Press the O I button to turn the power on When the heartbeat symbol appears on the display press the MEMORY button If there are three readings stored in memory that were taken within 10 minutes of the last reading an average value for those reading is displayed If there are only two readings in memory for that period the average will be based on two readings If there is only one reading in memory for that period that reading will be displayed as the average value 23 3 Using the Unit 24 Note If there are no measurements results stored in memory the screen to the right is displayed Press the MEMORY button again while the average values screen is displayed The result from the most recent measuremen
16. k you for purchasing the OMRON M1 Plus Upper Arm Blood Pressure Monitor The OMRON M1 Plus is a manual inflation blood pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly The unit also stores up to 21 measurements in memory and calculates an average reading based on the three most recent measurements taken within 10 minutes of the last reading If there are only two readings in memory for that period the average will be based on two readings If there is only one reading in memory for that period that reading will be displayed as the average value Please read this instruction manual thoroughly before using the unit For specific information about your own blood pressure CONSULT YOUR DOCTOR Important Safety Information Consult your doctor during pregnancy arrhythmia and arteriosclerosis You should never change the dosage of medication prescribed by your doctor Use the M1 Plus only for yourself A Caution e Do not leave the unit unattended with infants or persons who cannot express their consent e Do not use the unit for any purpose other than measuring blood pressure e Do not use a cellular phone near the unit This may result in incorrect operation of the unit e Do not operate unit in a moving vehicle car airplane e Do not apply strong shocks and vibrations to or drop the main unit and arm cuff e Only use four AAA mang
17. l Data Product Description Model Display Measurement Method Measurement Range Memory Accuracy Inflation Deflation Pressure Detection Power Source Battery life Operating temperature Humidity Storage temperature Humidity Console Weight Cuff Weight Outer Dimensions Cuff Dimensions Package Content Manual Inflation Blood Pressure Monitor OMRON M1 Plus HEM 4011C E LCD Digital Display Oscillometric method Pressure 0 mmHg to 299 mmHg Pulse 40 to 180 min 21 Measurements with date and time Pressure 3 mmHg Pulse 5 of display reading Manual by inflation bulb Automatic pressure release valve Capacitive pressure sensor 4 AAA batteries 1 5V Capacity of new alkaline batteries is approx 1500 measurements 10 C to 40 C Maximum 30 to 85 RH 20 C to 60 C Maximum 10 to 95 RH Approximately 210g without batteries Approximately 130g Approximately 106 w mm x 80 h mm x 136 I mm Approximately 146 mm x 446 mm Medium cuff arm circumference 22 to 32 cm Medium cuff instruction manual storage case battery set guarantee card blood pressure pass regular bulb Subject to technical modification without prior notice e This OMRON product is produced under the strict quality system of OMRON Healthcare Co Ltd Japan The Core component for OMRON blood pressure monitors which is the Pressure Sensor is produced in Japan for assembly e Disposal of this product and
18. ll still be able to use the unit for a short while You should replace the batteries with new ones ahead of time When the symbol ex remains lit the batteries are exhausted You should replace the batteries with new ones at once Turn the unit off before replacing the batteries Remove the batteries if the unit will not be used for three months or more If the batteries are removed for 30 seconds the Date Time setting will need to be reset See 2 2 Setting the Date and Time for details e Dispose of batteries according to applicable local regulations Four new AAA alkaline batteries will last for approximately 1500 measurements when used to take two measurements a day Since the supplied batteries are for monitoring use only they may have a shorter life and not last for 1500 measurements 2 Preparation 2 2 10 Setting the Date and Time Your blood pressure monitor automatically stores up to 21 measurements values including date and time of measurement in its memory and calculates an average value based on the three most recent measurements taken within 10 minutes of the last reading If there are only two readings in memory for that period the average will be based on two readings If there is only one reading in memory for that period that reading will be displayed as the average value To make use of the memory and average values functions e Set the unit to the correct date and time befor
19. ly tested and is designed for a long service life e It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy Please consult your authorised OMRON dealer or the OMRON Customer Service at the address given on the packaging or attached literature e Do not carry out any repairs yourself If a defect occurs or you have doubts about the correct functioning of the device consult your authorised OMRON dealer or the OMRON Customer Service 32 6 Maintenance and Storage Storage Keep the unit in its storage case when not in use Unplug the air tube from the air connector 2 Gently fold the air tube into the arm cuff Note Do not bend the air tube excessively 3 Place the arm cuff inflation bulb and main unit in the storage case Do not store the unit in the following situations e If the unit is wet e Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours e Locations exposed to vibrations shocks or where it will be at an angle e Locations exposed to chemicals or corrosive vapours 33 7 Optional Parts Medium Arm Cuffs Large Arm Cuff Small Arm Cuff Arm circumference 22 32cm Arm circumference 32 42cm Arm circumference 17 22 cm CL 4997065 4 CS 4997076 0 CM1 7935058 8 Small cuff and bulb combination Regular bulb Arm circumference 17 22 cm Ca So 4997099 9 4997965 1 34 Note 8 Technica
20. mmunity and emissions Nevertheless special precautions need to be observed e Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recom mendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mi
21. nd you should be in a relaxed seated position Make sure that the room is not too hot or cold e Do not take measurement after bathing drinking alcohol or exercising e Do not move or talk during measurement Correct Remove tight fitting clothing from Posture your upper arm and any thick clothing such as a sweater Do not place the cuff over thick clothes and do not roll up your sleeve i if it is too tight Sit upright with your back straight Place your arm on a table so that the cuff will be at the same The gap between the chair and the top of the table should be between 25cm to 30cm 3 Using the Unit Notes e Correct posture during measurement is necessary to get accurate results e You should also try to measure your blood pressure at the same time each day Within 1 hour after waking up is recommended Incorrect Posture e Arched back leaning forwards e Sitting cross legged e Sitting on a sofa or at a low table so that you lean forward These situations tend to lead to higher blood pressure values due to strain or the arm cuff being lower than the heart If the arm cuff is at a lower position than your heart use cushions etc to adjust the height of your arm 15 3 Using the Unit 3 2 16 Applying the Arm Cuff Be sure to wrap the arm cuff correctly so that you get accurate results Measurements can be taken in light clothing However please remove thick clothes such as
22. nt N Memory symbol 2 If flashing after measurement Displayed when viewing is complete indicates blood values stored in memory pressure out of recommended O Average value symbol range Displayed when viewing Pulse average value for the last three Deflation symbol measurements Date Time Buzzer symbol P Irregular heartbeat symbol Q Battery low symbol Reinflation symbol a Package contents V X Storage case e Instruction manual Y Four AAA alkaline LRO3 e Guarantee card batteries e Blood pressure pass e Blood Pressure Monitor unit 2 Preparation 2 1 Installing Replacing the Batteries Turn the main unit upside down Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover Install or replace four AAA size batteries so that the positive and negative polarities match the polarities indicated on the battery compartment Put the battery cover back in place Slide the battery cover as indicated until it clicks into place Note The measurement values continue to be stored in memory for maximum 30 seconds even after the batteries are replaced 2 Preparation Battery Life amp Replacement If the battery low symbol appears on the display replace all four batteries at the same time When the battery low symbol x starts to blink you wi
23. press the I O button to turn off the unit and press the air release button to release the air in the arm cuff Common Causes of Inaccurate Results Arm cuff is too loose Movement or talking Leaning forwards during measurement Note Ifthe arm cuff is at a lower position than your heart use cushions etc to adjust the height of your arm 19 3 Using the Unit The deflation symbol flashes on the display Blood pressure and pulse rate values are displayed 4 Measurement ends Press the air release button to Y release the air in the arm cuff until the deflation symbol is no longer displayed 5 Check the measurement results m a Systolic blood The unit automatically stores blood pressure pressure and pulse rate into its Disstolicbiobd memory including date and time of pressure measurement Refer to 3 4 Using Pulse the Memory Function e aa BD a m w lt lt E 5 gt Ca en e nu ca co The buzzer will sound if switched on when measurement is completed Notes e Self diagnosis of measured results and treatment are dangerous Please follow the instructions of your doctor e Wait 2 3 minutes before taking another blood pressure measurement Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement 6 Undo the fastener and remove the arm cuff T Press the I O button to turn the unit off Note If
24. sweaters before taking a reading Connect the air tube of the arm cuff and the inflation bulb to their respective air connectors Put your left arm through the cuff loop The air tube should run down the inside of your forearm and be in line with your middle finger Note If the cuff is not assembled pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop AN AN A IAN IAN 3 Using the Unit Position the arm correctly 1 The air tube should run down the inside of your forearm and be in line with your middle finger 2 The bottom of the cuff should be approximately 1 to 2 cm above your elbow 3 Apply the cuff to your upper arm so that the coloured marker blue arrow under tube is centered on the middle of your inner arm and points down the inside of the arm Taking measurements on the right arm Apply the cuff so that the air tube is at the side of your elbow Be careful not to rest your arm on the air tube or otherwise restrict the flow of air to the cuff The cuff should be 1 to 2 cm above the elbow 1 to 2 cm When the cuff is positioned correctly close the fabric fastener FIRMLY 17 3 Using the Unit Taking a Reading 3 3 18 Turning on the unit Note Press the air release button to release any air in the arm cuff 1 2 gt
25. t is displayed The date and time of each measurement is displayed alternately with the measurement values Important If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measurement result is displayed Refer to 3 3 number 7 Press the MEMORY button roy mw repeatedly to cycle through the previous measurement results Keep the button pressed down to cycle rapidly through the previous results If the irregular heartbeat symbol was displayed at the time of a measurement this is displayed when that result is displayed Press the I O button to turn the unit off If you forget to turn the unit off it will automatically shut itself off after five minutes 3 Using the Unit To Delete All the Values Stored in Memory You cannot delete individual stored readings all the readings in the unit will be deleted To delete stored readings first press the MEMORY button Then while holding it down press the I O button simultaneously for about 2 3 seconds All readings will then be deleted Important Be careful not to press the I O button first If the I O button is pressed first the monitor is shut off 2 Press the I O button to turn the unit off If you forget to turn the unit off it will automatically shut itself off after five minutes Notes e If the date and time are reset to a time before the most recent measurement the
26. xed with other commercial wastes for disposal This product does not contain any hazardous substances 9 Some Useful Information about Blood Pressure What is Blood Pressure Blood pressure is a measure of the force of blood flowing against the walls of the arteries Arterial blood pressure is constantly changing during the course of the heart s cycle The highest pressure in the cycle is called the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressure readings the Systolic and Diastolic are necessary to enable a doctor to evaluate the status of a patient s blood pressure Why is it a Good Thing to measure Blood Pressure at Home Having your blood pressure measured by a doctor can cause anxiety which is itself a cause of high blood pressure As a variety of conditions affect blood pressure a single measurement may not be sufficient for an accurate diagnosis Many factors such as physical activity anxiety or the time of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indication of any changes in blood pressure EN Blood pressure is typically low in the morning and increases from afternoon to evening It is lower in the summer and higher in the winter Blood pressure is measured in millimetres of mercury mmHg and measurements are written with the systolic pressure before the diastolic e g A