Home
Omron M1 Compact User's Manual
Contents
1. 9 Some Useful Information about Blood Pressure 33 Introduction Thank you for purchasing the OMRON M1 Compact Upper Arm Blood Pressure Monitor The OMRON M1 Compact is a manual inflation blood pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly The unit also stores up to 14 measurements in memory ME Please read this instruction manual thoroughly before using the unit For specific information about your own blood pressure CONSULT YOUR DOCTOR Important Safety Information Consult your doctor during pregnancy arrhythmia and arteriosclerosis You should never change the dosage of medication prescribed by your doctor Please read this section carefully before using the unit A Warning e Indicates a potentially hazardous situation which if not avoided could result in death or serious injury General Usage Always consult your doctor Self diagnosis of measurement results and self treatment are dangerous People with severe blood flow problems or blood disorders should consult a doctor before using the unit Cuff inflation can cause internal bleeding Battery Usage If battery fluid should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately A Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or pa
2. Manual Inflation Blood Pressure Monitor Model M1 Compact e Instruction Manual e Mode d emploi e Gebrauchsanweisung e Manuale di istruzioni Manual de instrucciones e Gebruiksaanwijzing PYKOBOACTBO NO KCMNYATAUNN e Instrukcja PL e Kezel si tmutat HU ai Y Gs e AR HREEE All for Healthcare IM HEM 4022 E 04 10 2011 1664455 7D Contents Before using the unit INtrOCUCTION sssrin eprore aeann trapin etren iran aan aneas i AE 3 Important Safety Information 1 Overview cece 6 2 Preparation c ccseseceesseeeeseeees 9 2 1 Installing Replacing the Batteries ooononccnnncicinnncicncccnncnns 9 Operating instructions 3 Using the Uniti niri eaaa etaa aeaiia dai 11 3 1 How to Sit Correctly When Taking a Measurement 11 3 2 Applying the Arm Cuff oooooccnnnccccnnnocccconocacononcnnonancnnanancnnanos 13 3 3 Taking a Readingis io iassa haori iauna 15 3 4 Using the Memory Function oooconoccccnocccconoccccononcnconacinannns 20 4 Quick Reference Guide oocmonncnnccnnnnnincnocnnonananac oran naar 23 Care and maintenance 5 Handling Errors and Problems oonmcccconnccinnnnccnnnancnanacnnnnnnos 24 5 1 Error Messages 24 5 2 Troubleshooting 1 26 6 Maintenance and Storage 28 7 Optional Parts coooonccconnncccnnnnnccanancncnannnnnnn cnn cnn cn rancia cnn 30 8 Technical Data ooconnncnnnnonnnnnnnnosncncnnnncn cacon nnar cnc cra re nana 31
3. Remove any tight fitting clothing from your upper arm Sit on a chair with your feet flat on the floor and place your arm ona table so that the arm cuff will be at the same level as your heart Apply the arm cuff to your upper arm The coloured marker should be centred on the inside of your arm and point down the inside of the arm so that the air tube runs down the inside of your forearm and is in line with your middle finger Secure the cuff around your arm using the fabric fastener strip Press the I O button to turn the unit on then pump the inflation bulb to inflate the cuff After measurement is complete and the measurement results are displayed press the air release button to release any air in the cuff Press the I O button to turn the unit off Note Always wait at least 2 3 minutes before taking another blood pressure measurement 23 5 Handling Errors and Problems 5 1 Error Display Error Messages Cuff is under inflated Press air release button and restart the measurement with a higher inflation level Carefully read steps under section 3 3 Movement during measurement Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 Air tube disconnected Insert the air tube securely Refer to section 3 2 Arm cuff not applied correctly Apply the arm cuff correctly Refer to section 3 2 Clothing is int
4. algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol CD If the irregular heartbeats cause the measurement to be invalid no result is shown If the irregular heartbeat symbol O is shown after you have taken a measurement repeat the measurement If the irregular heartbeat symbol O is shown frequently please make your doctor aware of it 18 3 Using the Unit What is Irregular Heartbeat An irregular Normal Heartbeat heartbeat is a Pulse heartbeat rhythm AAA A A A that varies by more Blood pressure SKAPLRARIN than 25 from the average heartbeat Irregular Heartbeat rhythm detected Short Long while the unit is Pulse measuring the Blood pressure ANAS LINN systolic and diastolic blood pressure If such an irregular rhythm is detected more than twice during measurement the irregular heartbeat symbol Q appears on the symbol when the measurement results are displayed What is Arrhythmia A heartbeat is stimulated by electrical signals that cause the heart to contract Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio electrical system that drives the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow brady
5. the previous measurement results Keep the button pressed down to cycle rapidly through the previous results If the irregular heartbeat symbol was displayed after a measurement it will also be stored in the memory with the result of that measurement Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after five minutes 21 3 Using the Unit To Delete All the Values Stored in Memory You cannot delete individual stored readings all the readings in the unit will be deleted 1 Press the I O button to turn the unit on 2 When the heartbeat symbol 49 appears on the display first press the M button Then while holding it down press the I O button simultaneously for about 2 3 seconds All readings will then be deleted Important Be careful not to press oe the I O button first If the I O button is Sto pressed first the Be monitor is shut off 3 Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after five minutes 22 Quick Reference Guide Use this as a quick reference guide only If you are using this device for the first time please read carefully Chapter 3 of this Instruction Manual To help ensure a reliable reading avoid eating drinking alcohol smoking or exercising for at least 30 minutes before taking a measurement Note
6. 13 3 Using the Unit 14 3 Position the arm correctly 1 The air tube should run down the inside of your forearm and be in line with your middle finger 2 The bottom of the cuff should be approximately 1 to 2 cm above your elbow 3 Apply the cuff to your upper arm so that the coloured marker blue arrow under tube is centered on the middle of your inner arm and points down the inside of the arm Taking measurements on the right arm Apply the cuff so that the air tube is at the side of your elbow Be careful not to rest your arm on the air tube or otherwise restrict the flow of air to the cuff The cuff should be 1 to 2 cm above the elbow 1 to2cm When the cuff is positioned correctly close the fabric fastener FIRMLY 3 3 2 3 Using the Unit Taking a Reading Preparation 1 Press the air release button to release any air in the arm cuff 2 Press the I O button to turn the unit on 3 Allitems in the display will be displayed briefly 4 The deflation symbol will flash 5 Finally the heartbeat symbol will appear and 0 is displayed etd 8 x be Note If the deflation symbol does not disappear soon press the air release button to release any air in the arm cuff Pump the inflation bulb to inflate the arm cuff 1 Inflate the cuff until it is 30 to 40 mmHg above your expected systolic blood pressure value ex If your expected blood pre
7. anical blood pressure measuring systems Ji Caution Please read the instruction manual carefully before using the device 31 8 Technical Data Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON Healthcare conforms to this EN60601 1 2 2001 standard for both immunity and emissions Nevertheless special precautions need to be observed Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the d
8. ational Society of Hypertension ISH developed the Blood Pressure Classification shown in this figure Systolic blood pressure mmHg A Severe hypertension 180 Moderate hypertension 160 Mild hypertension 140 Normal systolic value 199 Normal blood pressure 120 E Optimal blood pressure Diastolic target value blood gt 80 8 90 100 110 prenda mmHg This classification is based on the blood pressure values measured on people in a sitting position in outpatient departments of hospitals Note There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotensive 34 9 Some Useful Information about Blood Pressure Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN EU representative OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS REP www omron healthcare com OMRON DALIAN CO LTD Production facility i Dalian CHINA OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 ODG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH Subsidiary John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANTE FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Made in China EN 35
9. cardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination Whether the appearance of the irregular heartbeat symbol O in the results indicates arrhythmia or not can only be determined by an examination and diagnosis by your doctor AA Warning If the irregular heartbeat symbol O is shown frequently please make your doctor aware of it Conducting self diagnosis and treatment based on measurement results is dangerous Be sure to follow the instructions of your doctor 19 3 Using the Unit 3 4 Using the Memory Function The unit automatically stores up to 14 sets of measurement values blood pressure and pulse rate When 14 sets of measurement values are stored the oldest record is deleted to save the most recent values 20 Press the I O button to turn the power on DIA mmHg When the heartbeat symbol appears on the display press the M button The result from the most recent measurement is displayed Note If there are no measurements results stored in memory the screen to the right is displayed Important If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measurement result is displayed Refer to 3 3 number 7 3 Using the Unit Press the M button repeatedly to cycle through
10. case when not in use 1 Unplug the air tube from the air connector 2 Gently fold the air tube into the arm cuff Note Do not bend the air tube excessively 3 Place the arm cuff inflation bulb and main unit in the storage case Do not store the unit in the following situations If the unit is wet e Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours e Locations exposed to vibrations shocks or where it will be at an angle e Locations exposed to chemicals or corrosive vapours 29 7 Optional Parts Medium Arm Cuff Large Arm Cuff Small Arm Cuff Arm circumference Arm circumference Arm circumference 22 32 cm 32 42 cm 17 22 cm CM 4997086 7 CL 4997065 4 CS 4997076 0 Small cuff and bulb combination Arm circumference 17 22 cm Cavs Y 4997099 9 4997965 1 Regular bulb Note You need a special bulb for a small cuff When you use a small cuff please replace a cuff and a bulb together 30 8 Technical Data Product Description Model Display Measurement Method Measurement Range Memory Accuracy Inflation Deflation Pressure Detection Power Source Battery life Operating temperature Humidity Storage temperature Humidity Air Pressure Console Weight Cuff Weight Outer Dimensions Cuff Dimensions Package Content Note Subject to technical modification without prior notice This OMRON product is produced unde
11. cle is called the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressure readings the Systolic and Diastolic are necessary to enable a doctor to evaluate the status of a patient s blood pressure Why is it a Good Thing to measure Blood Pressure at Home Having your blood pressure measured by a doctor can cause anxiety which is itself a cause of high blood pressure As a variety of conditions affect blood pressure a single measurement may not be sufficient for an accurate diagnosis Many factors such as physical activity anxiety or the time of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indication of any changes in blood pressure Blood pressure is typically low in the morning and increases from afternoon to evening It is lower in the summer and higher in the winter Blood pressure is measured in millimetres of mercury mmHg and measurements are written with the systolic pressure before the diastolic e g A blood pressure written as 135 85 is referred to as 135 over 85 mmHg 200 Upper curve systolic blood pressure Lower curve diastolic blood pressure mmHg a o Time of day Example fluctuation within a day male 35 years old 33 9 Some Useful Information about Blood Pressure Classification of Blood Pressure by the World Heath Organization The World Health Organization WHO and the Intern
12. cm to 30cm 11 3 Using the Unit 12 Note You can take a measurement on either your left or right arm The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different Omron recommends to always use the same arm for measurement If the values between the two arms differ substantially please check with your physician which arm to use for your measurement Incorrect Posture Arched back leaning forwards Sitting cross legged Sitting on a sofa or at a low table so that you tend to lean forward These situations could lead to higher blood pressure values due to strain or the arm cuff being lower than the heart If the arm cuff is at a lower position than your heart use cushions etc to adjust the height of your arm 3 Using the Unit 3 2 Applying the Arm Cuff Be sure to wrap the arm cuff correctly so that you get accurate results Measurements can be taken in light clothing However please remove thick clothes such as sweaters before taking a reading 1 Connect the air tube of the arm cuff and the inflation bulb to their respective air connectors 2 Put your left arm through the cuff loop Note If the cuff is not assembled pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop jam AT liar CU TULL
13. ecautions Do not operate unit in a moving vehicle car airplane Do not apply strong shocks and vibrations to or drop the unit and arm cuff Do not take measurements after bathing drinking alcohol smoking exercising or eating Do not forcibly bend the arm cuff or bend the air tube excessively EN When removing the air tube pull on the edge of the tube at the connection with the main unit not the middle of the tube Do not inflate the arm cuff when it is not wrapped around your arm Do not wash the arm cuff or immerse it in water Read and follow the Important information regarding Electro Magnetic Compatibility EMC in the Technical Data Section Read and follow the Correct Disposal of This Product in the Technical Data Section when disposing of the device and any used accessories or optional parts 1 Overview Main unit A Display E Battery compartment B 1 O button Power switch C Air connector for cuff and inflation bulb D M Memory button Arm Cuff F Arm cuff Medium cuff arm circumference 22 32 cm G Air Tube 1 Overview Inflation Bulb H Air Release Button Air Tube J Air Inflation Bulb Display lt 388 o igg M AA TO O lad 188 ON 7 CJ K Systolic blood pressure O Heartbeat symbol L Diastolic blood pressure 1 Flashes during measurement 2 If flashing after measurement M Memory symbol completed or when viewing Displayed w
14. erfering with the arm cuff Remove any clothing interfering with the arm cuff Refer to section 3 2 Air is leaking from the arm cuff Replace cuff with new one Refer to Chapter 7 The arm cuff was inflated above 299 mmHg Release your hand from the air inflation bulb before the pressure reaches 299 mmHg Refer to section 3 3 ic doe 2 Blinks or appears continuously 24 Battery power is low Replace all four AAA batteries with new ones Refer to section 2 1 Error Display 5 Handling Errors and Problems ocS Device error Contact your OMRON retail outlet or distributor Refer to Chapter 8 I Pressure is too low iS 1 I ox Press the inflation bulb to inflate the arm cuff until the reinflation symbol goes out Or deflate the arm cuff and repeat measurement after checking that the heartbeat symbol 4 has been displayed Refer to section 3 3 Note The irregular heartbeat symbol OQ may also be displayed with error messages 25 5 Handling Errors and Problems 5 2 26 Troubleshooting Problem The reading is extremely low or high Arm cuff not applied correctly Apply the arm cuff correctly Refer to section 3 2 Movement or talking during measurement Remain still and do not talk during measurement Refer to section 3 3 Clothing is interfering with the arm cuff Remove any clothing interfering wit
15. h the arm cuff Refer to section 3 1 Arm cuff pressure does not rise Is the air tube securely connected into the main unit Make sure that the air tube is connected securely Refer to section 3 2 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to Chapter 7 Arm cuff deflates too soon The arm cuff is loose Apply the cuff correctly so that it is firmly wrapped around the arm Refer to section 3 2 Cannot measure or readings are too low or too high Has the arm cuff been inflated sufficiently Inflate the cuff so that it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3 Is the air release button being pressed during inflation Be careful not to press the air release button during measurement Problem The unit loses power during measurement 5 Handling Errors and Problems The batteries are empty Replace the batteries with new ones Refer to section 2 1 Nothing happens when you press the buttons The batteries are empty Replace the batteries with new ones Refer to section 2 1 The batteries have been inserted incorrectly Insert the batteries with the correct polarity Refer to section 2 1 Other problems Press the I O button and repeat measurement If the problem continues batteries with new ones try replacing the If this still doe
16. hen viewing values results stored in the memory stored in memory indicates blood pressure out of N Battery low symbol recommended range Pulse display Deflation symbol Reinflation symbol Irregular heartbeat symbol Note If your systolic or diastolic pressure is outside the standard range above 135 85 mmHg the Heartbeat symbol 4 will blink Please refer to Chapter 3 3 7 mov 0m 7 1 Overview Package contents others T Storage case U Four AAA alkaline LRO3 batteries w e Instruction manual e Guarantee card Blood pressure pass 2 Preparation 2 1 Installing Replacing the Batteries 1 Turn the main unit upside down 2 Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover 3 Install or replace four AAA size batteries so that the positive and negative polarities match the polarities indicated on the battery compartment 4 Put the battery cover back in place Slide the battery cover as indicated until it clicks into place Note The measurement values continue to be stored in memory even after the batteries are replaced 2 Preparation Battery Life amp Replacement If the battery low symbol x1 appears on the display replace all four batteries at the same time When the battery low symbol 3 starts to blink you will still be able to use the unit for a s
17. hort while You should replace the batteries with new ones ahead of time When the symbol 41 remains lit the batteries are exhausted You should replace the batteries with new ones at once Remove the batteries if the unit will not be used for three months or more Dispose of batteries according to applicable local regulations Four new AAA alkaline batteries will last for approximately 1500 measurements when used to take two measurements a day Since the supplied batteries are for monitoring use only they may have a shorter life and not last for 1500 measurements 10 3 Using the Unit 3 1 How to Sit Correctly When Taking a Measurement Correct posture during measurement is necessary to get accurate results Notes Measurements should be taken in a quiet place and you should be in a relaxed seated position Make sure that the room is not too hot or too cold Avoid eating drinking alcohol smoking or exercising for at least 30 minutes before taking a measurement Do not move or talk during measurement Correct Remove tight fitting clothing from Posture your upper arm and any thick N clothing such as a sweater Do not place the cuff over thick clothes and do not roll up your Sit upright sleeve if it is too tight with your back straight Place your arm on a table so that the cuff will be at the same The gap between the chair and the top of the table should be between 25
18. istance is shorter Further documentation in accordance with EN60601 1 2 2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment ad This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of quam its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal This product does not contain any hazardous substances 32 9 Some Useful Information about Blood Pressure What is Blood Pressure Blood pressure is a measure of the force of blood flowing against the walls of the arteries Arterial blood pressure is constantly changing during the course of the heart s cycle The highest pressure in the cy
19. r the strict quality system of OMRON Healthcare Co Ltd Japan The Core component for OMRON blood pressure monitors which is the Pressure Sensor is produced in Japan for assembly Disposal of this product and used batteries should be carried out in accordance with the national regulations for the disposal of electronic A we CE0197 This device fulfils the previsions of EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European Standard EN1060 products Manual Inflation Blood Pressure Monitor OMRON M1 Compact HEM 4022 E LCD Digital Display Oscillometric method Pressure 0 mmHg to 299 mmHg Pulse 40 to 180 min 14 Measurements Pressure 3 mmHg Pulse 5 of display reading Manual by inflation bulb Automatic pressure release valve Capacitive pressure sensor 4 AAA batteries 1 5V Capacity of new alkaline batteries is approx 1500 measurements 10 C to 40 C 30 to 85 RH 20 C to 60 C 10 to 95 RH 700 1060 hPa Approximately 126g without batteries Approximately 130g Approximately 86 w mm x 75 h mm x 109 I mm Approximately 146 mm x 446 mm Medium cuff arm circumference 22 to 32 cm Main unit medium cuff instruction manual storage case battery set guarantee card blood pressure pass regular bulb ps on invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromech
20. s not solve the problem contact your OMRON retail outlet or distributor 27 6 Maintenance and Storage Maintenance To protect your unit from damage please observe the following e Do not subject the main unit cuff and inflation bulb to extreme temperatures humidity moisture or direct sunlight Do not fold the cuff or tubing tightly Do not inflate the arm cuff over 299 mmHg Do not disassemble the unit e Do not subject the unit to strong shocks or vibrations for example dropping the unit on the floor Do not use volatile liquids to clean the main unit The unit should be cleaned with a soft dry cloth Use a soft moistened cloth and soap to clean the arm cuff Do not wash the arm cuff or immerse it in water Do not use petrol thinners or similar solvents to clean the arm cuff Y Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging Calibration and Service The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy Please consult your authorised OMRON dealer or the OMRON Customer Service at the address given on the packaging or attached literature 28 6 Maintenance and Storage Storage Keep the unit in its storage
21. ssure is around 140mmHg inflate the arm cuff to between 170 and 180 mmHg Inflate the cuff rapidly so that the pressure is reached in about five seconds d 2 When the desired pressure has been achieved release the inflation bulb Remain still and do not talk 15 3 Using the Unit 16 Notes If the reinflation symbol e appears squeeze the inflation bulb to re inflate the arm cuff Do not inflate the arm cuff more than necessary Measurement starts Measurement starts automatically after you stop 4 l inflating the arm cuff Decreasing UE o numbers appear on the display de Sy and the heartbeat symbol TAT a flashes Remain still and do not talk during measurement Note To cancel a measurement press the I O button to turn off the unit and press the air release button to release the air in the arm cuff Measurement ends When the measurement is finished the deflation symbol flashes on the display Blood pressure and pulse rate values are displayed Press the air release button to release the air in the arm cuff until the deflation symbol is no longer displayed 3 Using the Unit Check the measurement results Systolic blood The unit automatically stores Pressure blood pressure and pulse rate Diastolic blood into its memory Refer to 3 4 Pressure Using the Memory Function Pulse display Note Wait 2 3 minutes before taking another blood press
22. tient or damage to the equipment or other property General Usage Do not leave the unit unattended with infants or persons who cannot express their consent Do not use the unit for any purpose other than measuring blood pressure Do not disassemble the unit arm cuff or inflation bulb Use only the approved arm cuff for this unit Use of other arm cuffs may result in incorrect measurement results Make sure that the air tube is not wrapped around other parts of your body when taking measurements at night This could result in injury when the air pressure in the air tube is increased Do not wrap the arm cuff tightly when taking measurements at night This could result in injury 4 Important Safety Information Do not inflate the arm cuff over 299 mmHg If the cuff is over inflated it can cause internal bleeding Do not use a mobile phone near the unit This could cause a malfunction Battery Usage If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Use only four AAA alkaline batteries with this unit Do not use other types of batteries Do not insert the batteries with their polarities incorrectly aligned e Replace old batteries with new ones immediately Replace all four batteries at the same time Remove the batteries if the unit will not be used for three months or more Do not use new and used batteries together General Pr
23. ure measurement Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement A Warning Self diagnosis of measured results and treatment are dangerous Please follow the instructions of your doctor Common Causes of Inaccurate Results Arm cuff is too loose Movement or talking Leaning forwards during measurement Note Ifthe arm cuff is at a lower position than your heart use cushions etc to adjust the height of your arm Undo the fastener and remove the arm cuff Press the I O button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after five minutes 17 3 Using the Unit Important If your systolic or diastolic pressure is outside the standard range the heartbeat symbol will blink when the measurement result is displayed Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg This criteria is for home blood pressure measurement For professional office blood pressure measurement criteria please refer to Chapter 9 Some Useful Information about Blood Pressure Your blood pressure monitor includes an irregular heartbeat feature Irregular heartbeats can influence the results of the measurement The irregular heartbeat
Download Pdf Manuals
Related Search
Related Contents
PATIO GAS GRILL PATIO PARRILLA A GAS P57-59 BrokerMetrics Enterprise User Manual OmniMount WM1-S flat panel wall mount User`s Manual for Thuban 1.0 - Previous Directory Sumário Atos do Poder Judiciário Atos do Poder Achiever CCS5000 Shredder - C:\Documents and Settings\Gini\My Documents\GINI''S FILES\MANUALS\Achiever CCS5000 paper shredder 取扱説明書 ED-POG-1TS Gefen EXT-CAT5-7000 console extender Copyright © All rights reserved.