1. BF510 Body Composition Monitor e Instruction Manual e Mode d emploi e Gebrauchsanweisung e Manuale di istruzioni e Manual de instrucciones e Gebruiksaanwijzing e PYKOBOOCTBO NO KCMIYATAUNN Cj sla Liis e AR Thank you for purchasing the OMRON Body Composition Monitor Before using this unit for the first time please be sure to read this Instruction Manual carefully and use the unit safely and properly Please keep this Instruction Manual at hand all the time for future reference A Good Sense of IM HBF 510 E 04 08 08 1665710 1D BF510 Body Composition Monitor Please read instructions carefully before use and keep this manual for future reference Do not use this unit for purposes other than described in this manual Contents Before using the unit 4 Taking a Measurement ssssssseesesseeees 7 Notes on Safety sses 1 5 Measuring Weight Only sssr 10 Useful Information cscssssscssscssseeeerses 2 Care and maintenance Operating instructions 6 Error Displays sssssssssssssscsssssssssssssesssssseees 11 4 Know Your Unit sesssssssscessssesssesstessesssesseen 4 7 Troubleshooting ssssssersrssrereseesesorossenesesseses 11 2 Inserting and Replacing the Batteries 4 8 How to Take Care of and Store the Unit 12 3 Setting and Storing Personal Data 5 9 Technical Data viissiscivicisssinsssuiinstssitinaestrasetia 13 Notes on Safety Symbols and definitions are as
2. 4 Taking a Measurement 5 Check the measurement results Press the SET MODE button to view the desired measurement results The display changes with each press of the SET MODE button as follows FAT gt VISCERAL FAT gt BMI gt MUSCLE gt WEIGHT again No 1 WEIGHT WT MH wy 70 UU Ace No 1 MUSCLE Skeletal Muscle Percentage i Body Fat Percentage Skeletal Muscle Percentage se Body Fat Percentage Classification Classification 4a BMI Classification Classification Interpreting the Body Fat Percentage Result Cender Age Low Nomaro Migne Very High 20 38 lt 210 210 329 330 389 300 40 58 230 230 339 340 399 400 20 39 lt 80 80 199 200 249 250 a 59 lt mo 14 0 219 220 279 280 30 0 Based on NIH WHO guidelines for BMI Based on Gallagher et al American Journal of Clinical Nutrition Vol 72 Sept 2000 Interpreting the Visceral Fat Level Result Visceral Fat Level Level Classification 0 Normal High Very High According to Omron Healthcare figures 5 Measuring Weight Only Interpreting the BMI Result BMI Designation by the WHO BMI Classification Bar C Jjo C G 18 5 lt BMI lt 25 0 Normal cease 25 lt BMI lt 30 Overweight Beam 6 28 30 lt BMI Obese peeueecwe eeeaeeeeeeece 40 ie 90 0 The above mentioned indices refer to the values for obesity judgment proposed by WHO the W
3. Moisten the palms or soles with a wet towel then repeat measurement e Please ensure that age gender and height settings stored as personal data are correct see Setting Items in Section 9 e The main unit cannot measure body composition outside its measurement range even if the Age Gender and Height settings are correct Insert the batteries again and repeat measurement Abnormal operation If this error still occurs consult your OMRON service representative You stepped on the unit before the display Step on the main unit after the display indicated 0 0 kg indicates 0 0 kg You moved the main unit before the display Do not move the main unit until the display indicated 0 0 kg indicates 0 0 kg a a Walle a a Do not move while measuring body weight Body weight of 150 kg 330 0 Ib or over is Your weight is 150 kg 330 0 Ib or over out of the measuring range of this unit You 7 Troubleshooting Values of body composition are out of measurable range cannot use this unit Problem Cause Correction The displayed value of body composition is abnormally high or low The power turns off approximately 5 minutes after the body weight is confirmed and before your body fat percentage visceral fat level and skeletal muscle percentage is measured Nothing is displayed when the power is turned on Refer to Useful Information You did not select the correct per
4. 0 0 kg Wait until 0 0 kg is displayed Press the USER button to select your personal profile number 1 The selected number blinks on the display 2 Press the SET MODE button to confirm Then the default age setting blinks on the display Selecting Measurement Unit 3 TO SET THE AGE Setting range 10 to 80 years old 1 Press the or V button to adjust the age 2 Press the SET MODE button to confirm Then the gender icons blink on the display 4 TO SET THE GENDER AND HEIGHT Set the gender MALE or FEMALE and height in the same way After all the settings are displayed for your confirmation 0 0 kg appears on the display This completes the setting You can change the measurement units used for the height and weight settings 1 Turn on the power CAL blinks on the display then the display changes to 0 0 kg Wait until O 0 kg appears on the display Keep the W button pressed until Ib and kg blink on the display 3 Press the W button to select kg or Ib This will also automatically change cm and In 4 Press the SET MODE button to confirm All height and weight measurements are displayed using the new measurement units The change remains in effect until you change it again 3 Setting and Storing Personal Data Changing the Personal Data 1 Turn on the power With
5. Do not carry out repairs of any kind yourself If a defect occurs consult the OMRON distributor or Customer Services as mentioned on the packaging 9 Technical Data Name Product Model Display Setting Items Weight Accuracy Accuracy S E E Power Supply Battery Life Operating Temperature Humidity Storage Temperature Humidity Air Pressure Weight External Dimensions Package Contents Note BF510 Body Composition Monitor HBF 510 E Body Weight 0 to 150 kg with an increment of 0 1 kg 0 0 to 330 0 Ib with an increment of 0 2 Ib Body Fat percentage 5 0 to 60 0 with an increment of 0 1 Skeletal Muscle percentage 5 0 to 50 0 with an increment of 0 1 BMI 7 0 to 90 0 with an increment of 0 1 Visceral Fat Level 30 levels with an increment of 1 level BMI classification Underweight 0 Normal Overweight Obese with 12 levels of Bar display Body fat percentage and Skeletal muscle percentage classification Low 0 Normal High Very High with 12 levels of Bar display Visceral fat level classification 0 Normal High Very High with 9 levels of Bar display Height 100 0 to 199 5 cm 3 4 to 6 6 3 4 Age 10 to 80 years old Gender Male Female Measurement Units kg cm lb feetsinch The age range for the skeletal muscle percentage skeletal muscle percentage classification visceral fat level and visceral fat level classification is 18
6. Do not use the unit on slippery surfaces such as a wet floor immediately rinse with plenty of clean water e Keep the unit out of the reach of young children e Remove the batteries from this unit when you are e Do not jump onto the unit or hop up and down on not going to use it for a long period of time the unit approximately three months or more Do not use different types of batteries together Do not use new and worn batteries together Remove the display unit from main unit before e Do not use this unit when your body and or feet are wet such as after taking a bath e Stand on the main unit bare footed Attempting to stand on it with socks on may cause you to slip and stepping on the unit If you try to remove the display result in injury unit while stepping on to the unit you may lose your e Do not step on the edge or display area of the main balance and fall unit e People with disabilities or who are physically frail Read and follow the Important information regarding should always be assisted by another person when Electro Magnetic Compatibility EMC in the using this unit Use a handrail or so when stepping Technical Data Section on the unit Useful Information Principle of body composition calculation Body fat has low electric conductivity The BF510 measures the body fat percentage by the Bioelectrical Impedance BI method Muscles blood vessels and bones are body tissues with a high water content
7. Holder J DDD Front View Foot Electrodes o E Power Switch omron KaradaScan Body Composition Monitor Heel Electrodes Main Unit Measurement Platform 2 Inserting and Replacing the Batteries 1 Open the battery cover on the back of 3 Close the battery cover the main unit 1 Press the tab of the battery cover to Battery Life and Replacement release it When the battery low indicator XJ appears replace all four batteries with new ones Tab Items stored in memory are retained even if the batteries are removed e Replace the batteries after turning off the power e Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries e Four AA batteries will last approximately 1 year when measurements are made four times a 2 Pull it up as shown day K a S e Because the supplied batteries are for trial use 2 Install the batteries in correct polarity only they may have a shorter life as marked inside the battery compartment m 3 Setting and Storing Personal Data For the measurement of body fat percentage visceral fat level and skeletal muscle percentage it is necessary to set your personal data age gender height 1 Turn on the power CAL blinks on the display then the display changes to
8. chart Daily activities After waking up Recommended time Breakfast m2 hours Before lunch and about 2 hours or more after breakfast Recommended time Lunch 2 hours amp In the afternoon about 2 hours or Recommended time more after lunch and before taking a bath or eating dinner Takingabathor Je 7 gt eating dinner _ a e eo ee l 2 hours Before going to bed and about 2 hours or more after dinner or bath Recommended time Going to bed Avoid taking measurements under the following conditions If a measurement is made under these physical conditions the estimated body fat percentage may differ significantly from the actual one because the water content in the body is changing Avoid taking measurements immediately after vigorous exercise Please wait for 2 hours or more after a bath or sauna after drinking alcohol after drinking lots of water after eating a meal Useful Information What is BMI Body Mass Index BMI uses the following simple formula to indicate the ratio between weight and height of a person BMI weight kg height m height m The OMRON BF510 uses the height information stored in your personal profile number or when entering information in the Guest Mode to calculate your BMI classification If the fat level revealed by BMI is higher than the international standard there is an increased likelihood of common diseas
9. follows N Danger Improper use may cause danger resulting in death or serious injury N Warning Improper use may result in possible death or serious injury Caution Improper use may result in injury or property damage e If battery fluid should get in your eyes immediately Z Danger Sa o rinse with plenty of clean water Consult a doctor e Never use this unit in combination with medical immediately electronic devices such as 1 Medical electronic implant h 1 i ic implants such as A Caution pac mae D tdi mble repair or remodel the displ 2 Electronic life support systems such as i ase a E unit or the main unit Do not use a cellular phone near the display unit or the main unit Take care when storing the display unit Your fingers may be trapped between the grip and the main unit if you press it too strongly an artificial heart lung 3 Portable electronic medical devices such as an electrocardiograph This unit could cause these devices to malfunction posing a considerable health risk to users of these devices Do not use batteries not specified for this unit Do not insert the batteries with the polarities in the AN Warning wrong direction e Never start weight reduction or exercise therapy e Replace worn batteries with new ones immediately Do not dispose of batteries in fire If battery fluid should get on your skin or clothing without the instructions of a doctor or specialist e
10. to 80 years old The age range for the body fat percentage classification is 20 to 79 years old 0 0 kg to 40 0 kg 0 4 kg 0 0 Ib to 88 2 Ib 0 88 Ib 40 0 kg to 150 0 kg 1 88 2 Ib to 330 0 Ib 1 Body Fat percentage 3 5 Skeletal Muscle percentage 3 5 Visceral Fat Level 3 levels 4 AA batteries R6 You may also use AA alkaline batteries LR6 Approximately 1 year when manganese batteries are used with four measurements a day 10 C to 40 C 30 to 85 RH 20 C to 60 C 10 to 95 RH 700 hPa 1060 hPa Approximately 2 2 kg 4 85 Ib including batteries Display unit Approx 300 W x 35 H x 147 mm D Approx 11 3 4 W x 1 3 8 H x 5 3 4 D Main unit Approx 303 W x 55 H x 327 mm D Approx 11 7 8 W x 2 1 8 H x 12 7 8 D Body Composition Monitor 4 AA manganese batteries R6 instruction manual Guarantee Card Subject to technical modification without prior notice Rh Tresr CE0197 Ba Please read the instruction manual carefully before using the device 13 14 9 Technical Data Correct Disposal of this Product St Waste Electrical amp Electronic Equipment This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of was
11. when measuring weight only 4 Taking a Measurement Measurement should be taken on a level and hard surface 1 Turn on the power 4 Start measurement CAL blinks on the display then the display changes to 0 0 kg 1 Step on the main unit and place your feet on the foot electrodes with your weight evenly distributed If you step onto the unit before 0 0 kg appears on the display an error message Err will appear The display will show your weight and then the weight result will blink twice The unit will then start to measure your body fat 2 When the 0 0 kg is displayed take _ ee visceral fat level and skeletal muscle out the display unit 2 When START appears on the display extend your arms straight at a 90 angle to your body Note Do not take out the display unit until 0 0 kg appears on the display Otherwise the weight of the display is add to your body weight which causes an incorrect result FAT VISCERALFAT MUSCLE 3 Select the personal profile number Press the USER button while holding the display unit Selected number will appear after blinking once If the following display is indicated The indicators in the measurement progress bar at the bottom of the display will gradually appear from left to right Your personal data is not stored in the personal 3 After the measurement fre fil b h lected PI is complete your profile n
12. es However not all types of fat can be revealed by BMI What is Body Fat Percentage Body fat percentage refers to the amount of body fat mass in regards to the total body weight expressed as a percentage Body fat percentage Body fat mass kg Body weight kg x 100 Our device uses BI method to estimate your body fat percentage Depending on where fat is distributed in the body it is classified as visceral fat or subcutaneous fat What is Visceral Fat Level Visceral fat fat surrounding internal organs Too much visceral fat is thought to be closely linked to increased levels of fat in the bloodstream which can lead to common diseases such as hyperlipidemia and diabetes which impairs the ability of insulin to transfer energy from the bloodstream and using it in cells In order to prevent or improve conditions of common diseases it is important to try and reduce visceral fat levels to an acceptable level People with high visceral fat levels Ss tend to have large stomachs However this is not always the case and high visceral fat es A Fat image levels can lead to metabolically obese Metabolically obese visceral obesity with normal weight represents fat levels that are higher than average even if a person s weight is at or below the standard for their height What is Subcutaneous Fat Subcutaneous fat fat below the skin Subcutaneous fat not only accumulates around the stomach but also around the upper arm
13. orld Health Organization Interpreting the Skeletal Muscle Percentage Result Gender a Very High lt 33 1 33 1 39 1 39 2 43 8 43 9 7 80 32 9 38 9 39 0 43 6 gt 43 7 According to Omron Healthcare figures 6 After confirmation of the results turn off the power Note If you forget to turn off the power the unit will be turned off automatically after 5 minutes 5 Measuring Weight Only 1 Turn on the power 3 Check the measurement result CAL blinks on the display then the display changes to 0 0 Your weight is displayed and blinks twice to indicate that measurement is completed Note You can also check the measurement kg result by taking out the display unit If you step onto the SS unit before 0 0 kg 4 When the measurement is completed appears on the step down from the unit and turn off display an error the power message Err will appear 2 When the 0 0 kg is displayed step onto the unit Note Leave the display unit in the display unit holder 6 Error Displays Your palms or soles are not in firm contact with the electrodes The posture for measurement is wrong or the palms or soles are not in firm contact with the electrodes The palms or soles are too dry Press your palms or soles firmly to the electrodes then measure Refer to Section 4 Measure without moving the hands or soles Refer to Section 4
14. s hips and thighs and can cause a distortion of the body s proportions Although not directly linked to increased risk of disease it is thought to increase pressure on the heart and other complications Subcutaneous fat is not displayed in this unit but is included in ex TA the body fat percentage Sample Subcutaneous Fat MRI image What is Skeletal Muscle Muscle is divided into two types muscle in internal organs such as the heart and skeletal muscle attached to bones that is used to move the body Skeletal muscle can be increased through exercise and other activity Increasing the ratio of skeletal muscle means that body can burn energy more easily which means that it is less likely to turn to fat and makes it easier to lead an energetic lifestyle The reason calculated results may differ from actual body fat percentage The body fat percentage measured by this unit may significantly differ from the actual body fat percentage in the following situations Elderly people People with a fever Body builders or highly trained athletes Patients undergoing dialysis Patients with osteoporosis who have very low bone density Pregnant women People with swelling These differences may be related to changing ratios of body fluid and or body composition 1 Know Your Unit Display Unit Grip Electrodes Display Buttons Up Down Buttons B USER Button Cf GUEST GUEST Button Pi 8 Display Unit
15. sonal profile number or the Select the correct personal profile GUEST mode The personal profile number or the GUEST mode Refer number or G is not displayed on to Section 4 the display unit Batteries are not inserted Insert the batteries The polarities of batteries are not Insert the batteries in correct aligned correctly alignment Te Dances arawon out Replace all four batteries with new ones Refer to Section 2 The cord connecting the main unit Contact the nearest OMRON and the display unit is damaged or service representative worn 11 12 8 How to Take Care of and Store the Unit How to Clean the Unit e Always keep the unit clean before use e Wipe the main unit with a soft dry cloth If necessary use a cloth moistened with water or detergent and squeeze it well before wiping the unit then wipe dry with a dry cloth e You can use rubbing alcohol to clean the electrodes but do not use it on other parts of the unit e Do not use benzene or thinner to clean the unit Care and Storage e Store the display unit in the main unit as shown e When storing the display unit be careful not to crease the cord e Do not store the unit in the following conditions Humidity where moisture or water may get into the unit High temperatures direct sunlight or dusty places Places with the risk of sudden shocks or vibrations In places where chemicals are stored or where corrosive gas is present e
16. tes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal This product does not contain any hazardous substances Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PCs and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim of preventing unsafe product situations the EN60601 1 2 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device man
17. that conducts electricity easily Body fat is tissue that has little electric conductivity The BF510 sends an extremely weak electrical current of 50 KHz and less than 500 uA through your body to determine the amount of fat tissue This weak electrical current is not felt while operating the BF510 In order for the scale to determine body composition it uses the electrical impedance along with your height weight age and gender information to generate results based on OMRON s data of body composition Measures the whole body to avoid the influence of fluctuations During the course of a day the amount of water in the body tends to gradually shift to the lower limbs This is why there is a tendency for the legs and ankles to swell in the evening or at night The ratio of water in the upper body and lower body is different in the morning and evening and this means that the electrical impedance of the body also varies Since the BF510 uses electrodes for both hands and feet to take measurements it can reduce the influence of these fluctuations on measurement results Recommended measurement times Understanding the normal changes in your body fat percentage can help you in preventing or reducing obesity Being aware of the times when the body fat percentages shift within your own daily schedule will assist you in obtaining an accurate trending of your body fat It is recommended to use this unit in the same environment and daily circumstances See
18. the A or W button modify the CAL blinks on the display then the display selected item followed by presang changes to 0 0 kg SET MODE button The display will Wait until 0 0 kg appears on the display change in order of age gender and a height Press the USER button to select your personal profile number 1 Your number flashes one time on the display 2 Press the SET MODE button to confirm Then the selected age setting blinks on the display Deleting the Personal Data 1 Turn on the Power Delete the personal data CAL blinks on the display then the display Press the GUEST changes to 0 0 kg button for more Wait until O 0 kg appears on the display than two seconds _ OOO Clr will appear on Press the USER button to select the display and the your personal profile number personal data are deleted from memory 1 Your number flashes one time on the display 2 Press the SET MODE button to confirm Then the selected age setting blinks on the display Power Switch The power will automatically switch off in the following conditions 1 Ifthe monitor is not used within one minute of 0 0 kg appearing on the display 2 Ifno information is entered for 5 minutes when entering personal data 3 Ifthe monitor is not used for 5 minutes after the measurement results are displayed 4 Five 5 minutes after the result is displayed
19. ufactured by OMRON Healthcare conforms to this EN60601 1 2 2001 standard for both immunity and emissions Nevertheless special precautions need to be observed Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com EU representative Subsidiary 24 Yamanouchi Yamanoshita cho Ukyo ku Kyoto 615 0084 Japan OMRON HEALTHCARE EUROPE B V Kruisweg 577 2132 NA Hoofddorp The Netherlands REP www omron healthcare com OMRON HEALTHCARE UK LTD OMRON HEALTHCARE CO LTD l Opal Drive Fox Milne Milton Keynes MK15 ODG United Kingdom OMRON Medizintechnik Handelsgesellschaft mbH John Deere Str 81a 68163 Mannheim Germany www omron medizintechnik de OMRON SANT FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France Made in China UOUWO 01SAqd
20. umber you have selected Please see weight is displayed Section 3 to store personal data again At this point you may step off the unit If you do not have personal data stored on the unit GUEST mode 1 Press the GUEST button while holding the display unit 2 The GUEST indication G appears on the display 3 Set the personal data age gender and height Read steps 3 through 4 in Section 3 Setting and Storing Personal Data 4 Taking a Measurement Correct Posture for Measurement 2 The arms are horizontally raised and After measuring the elbows are extended straight your weight Extend your arms straight at a 90 angle to your body Hold the display unit so that you can see the display Stand with your knees and back straight and look straight ahead Press your palms firmly on the grip electrodes Ama a m24 a w enunnon Place your middle Hold the inner grip Hold the outer grip fingers in the dent electrodes firmly with electrodes with your at the back of the your thumb and ring finger and small grip electrodes index finger finger Heel Electrodes e Make sure each of your heels is positioned on a heel electrode Stand with your weight evenly distributed on the measurement platform Postures to Avoid During Measurement Movement during Arms bent Arms too low or Display facing Knees bent Standing on edge measurement high upwards of unit