Omnitron Systems Technology iConverter 100Tx User's Manual

image

Contents

1. matched pairs The transmit Tx and receive Rx wavelengths of one converter must match the receive Rx and transmit Tx wavelengths of the mating converter For example an 8370 1 must be connected to an 8371 1 Page 7 example the fault at the fiber port is propagated forward causing the switch port to drop its link due to the propagated fault Fig 1 c The Remote Fault Detection RFD mode transmits a link signal only when a link signal is detected When a loss of link is detected this mode will perform both a loop back and propagate forward For example the fiber fault is looped back in the opposite direction causing the port on the other media converter to lose fiber link It also propagates the fault forward toward the UTP port causing the switch port to lose link Fig 1 d Note Connecting two converters set to RFD is an illegal setting and will cause a deadly embrace lockup Symmetrical Fault Detection is only supported on modules with the revision of xx 08 In Symmetrical Fault Detection SFD the UTP port transmits a Link signal only when receiving a Link at the fiber port The fiber port transmits a Link signal only when receiving a Link signal at both the fiber port and the UTP port As a result fiber faults no Link received at the fiber are looped back and can be reported to the network core In addition connecting two back to back converters which are both set to SFD facilitates dual loop back whe
2. signal will only affect the port detecting the loss of signal All the other ports will continue to generate a link signal For example a loss of link on the fiber port only affects the fiber port the other ports remain unaffected Fig 1 b The Link Propagate LP mode transmits a link signal only when a link signal is detected Utilizing this configuration a loss of a receive link signal will continue to propagate through to the next port in the network For Page 2 LED INDICATORS LED Color Description Pwr Yellow On Power on F O Lk Green On Link Blink Activity AN Green On UTP Auto Negotiation enabled FDx Green On Full Duplex mode UTP Lk Green On UTP Link Blink Activity MOUNTING AND CABLE ATTACHMENT The iConverter modules are hot swappable and can be installed into any iConverter chassis 1 Using the chassis module guides for alignment insert the module into the selected slot and secure using the front panel fastener screw Note Ensure that the module is firmly seated against the backplane 2 Using a Category 5 cable attach the UTP port to a 100BASE TX Ethernet device 3 Using a multimode or single mode dual fiber cable as required per the converter type attach the fiber port toa 100BASE FX mating Ethernet device The transmit Tx must attach to the receive side of the mating device and the receive Rx must attach to the transmit side 4 Single fiber SF converters must be used in
3. 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 USA Email support omnitron systems com URL www omnitron systems com Form 040 08360 001G 9 07 Page 10
4. LS RFD Remote Fault Detection LP RFD LP RFD LP legal Setting Fig 3 Link Mode Selection Table Link Mode LS Normal Link Segment LS Link Propagate LP SW SW2 ormal Remote Fault Detection LP RFD LP Symmetrical Fault Detection SFD Fig 4 Link Mode Selection Table for Revision xx 08 UTP Auto Manual Negotiate AN Man DIP Switch When this DIP Switch is in the UTP Auto Negotiate AN position factory setting the converter auto negotiates Page 5 equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory Technical Support For help with this product contact our Technical Support Phone 949 250
5. ed hard coded UTP port may result in an unpredictable port setting with excessive collisions and poor link performance When operating in Manual mode both mating ports MUST be set manually to the same speed and duplex mode RJ45 Crossover X Switch Not Shown When connecting the UTP to a hub or switch set this front plane switch to Straight Through factory setting When connecting to a workstation set it to Crossover X Page 6 OVERVIEW The iConverter 100Fx Tx converters support the IEEE 802 3 Ethernet standard and converts 100BASE FX fiber to 100BASE TX unshielded twisted pair UTP Models are available for multimode MM and single mode SM dual fiber and single mode single fiber The 100Fx Tx supports UTP Half Duplex and Full Duplex auto negotiation with manual override and features a crossover UTP switch for easy attachment to hubs switches and workstations The 100Fx Tx can be used in an unmanaged or managed fashion When unmanaged it can be installed in a chassis without an iConverter Network Management Module NMM or iConverter 10 100M2 To be managed an NMM module or 10 100M2 module must be installed in the same chassis LINK MODES In order to accommodate different user needs the 100Fx Tx supports three different linking modes The Link Segment LS mode transmits a link signal independently of any received link at any port Utilizing this configuration a loss of a receive link
6. fied and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS Or you may register your product on the Internet at www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyers designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied Page 9 FRONT PANEL DIP SWITCH SETTINGS Link Segment Link Seg J Link Prop Link Propagate Normal Norm DE R Fit Det Remote Fault Detect UTP Auto Negotiate AN J Man UTP Manual Negotiate UTP Full Duplex FDX J HDX UTP Half Duplex Fig 2 Front Panel DIP Switches LS Normal Link Segment LS LP Normal Link Propagate LP
7. osr Omnitron Systems Technology Inc iConverter 100Fx Tx User Manual SM 120 km 8363 3 8367 3 iConverter 100Fx Tx SF Single Fiber Modules ence Tx 1310 nm Tx 1550 nm Rx 1550 nm Rx 1310 nm Type Suse 20704 E Sis 29702 sa712 For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models When using single fiber SF media converter models the Tx wavelength on one end has to match the Rx wavelength on the other Page 1 and matches the duplex mode of a mating auto negotiating device connected to its UTP port When in the UTP Manual Negotiate Man position the converter does not auto negotiate and operates in the duplex mode selected by the UTP Full Half Duplex FDX HDX DIP Switch UTP Full Half Duplex FDX HDX DIP Switch When the UTP Auto Manual Negotiate AN Man DIP Switch is in the Manual Man position the UTP Full Half Duplex FDX HDX DIP Switch determines the duplex mode for the converter When the UTP Full Half Duplex DIP Switch is in the UTP Full Duplex FDX position factory setting the converter operates in Full Duplex mode When in the UTP Half Duplex HDX position it operates in Half Duplex mode Set the duplex mode to match the connecting device and check for link status Note Attaching an auto negotiating UTP port to a non auto negotiating manual forc
8. re fiber faults are reported to both ends of the network link A blinking fiber link LED on a converter indicates a fault of the transmit fiber or UTP cables of that converter Fig 1 e Note Converters in SFD mode must be deployed in pairs Page 3 100Fx Tx SPECIFICATIONS 100Fx Tx Model Type Protocols 100BASE FX 100BASE TX Copper RJ 45 Connectors Fiber SC ST LC MT RJ SFD Connectors Single Fiber SC UTP X over LS LP RFD Controls UTP FDX HDX UTP A N Power FO link UTP link CEU DISpayg Auto FDX HDX W 0 85 x D 4 5 x H 2 8 UL CE FCC Class A Compliance NEBS Level 3 Power cuisine 0 7A 3 3VDC typical Standard 0 to 50 C Temperature Wide 40 to 60 C Storage 40 to 80 C 5 to 95 non condensing 100m to 4000m 730 000 Page 8 Humidity MTBF hrs LS LS a Switch 1 Converter A Converter B Switch 2 LS LS R l okl eh Switch 1 Converter A Converter B Switch 2 LP LP A kt ok Switch 1 Converter A Converter B Switch 2 LP RFD LP Switch 1 Converter A Switch 1 Converter A Converter B Switch 2 LED Lit LED Blinking A LED Off O LED Status depends on connected device Fig 1 Link Modes Page 4 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are quali