1. mes Shop on line at www omega com e mail info omega com 7 Dual Relay Option Board for the DPF700 Meter CEOMEGA OMEGAnet On Line Service Internet e mail www omega com info omega com USA ISO 9001 Certified Canada Servicing North America One Omega Drive P O Box 4047 Stamford CT 06907 0047 TEL 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 TEL 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance USA and Canada Mexico and Latin America Benelux Czech Republic France Germany Austria United Kingdom ISO 9002 Certified Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TEL 001 800 FAX 001 203 359 7807 En Espa ol 001 203 359 7803 e mail espanol omega com Servicing Europe Postbus 8034 1180 LA Amstelveen The Netherlands TEL 31 20 3472121 FAX 31 20 6434643 Toll Free in Benelux 0800 0993344 e mail sales omegaeng nl Frystatska 184 733 01 Karvin TEL 420 59 6311899 FAX 420 59 6311114 e mail info omegashop cz 11 rue Jacques Cartier 78280 Guyancourt TEL 33 1 61 37 29 00 FAX 33 1 30 57 54 27 Toll Free in France 0800 466 342 e mai
2. faces oa eas ae E ERG ves Me bu d EEG ie Re 1 1 UNPACKING Remove the Packing List and verify that all equipment has been received If there are any questions about the shipment use the phone number for the Customer Service Department nearest you Upon receipt of shipment inspect the container and equipment for any signs of damage Take particular note of any evidence of rough handling in transit Immediately report any damage to the shipping agent The carrier will not honor any claims unless all shipping material is saved for their examination After examining and removing contents save packing material and carton in the event reshipment is necessary 1 2 SAFETY CONSIDERATIONS Refer to your main owners guide manual for complete safety considerations accordance with Class of EN 61010 115 230 AC power connections Installation of this This option card is intended for use in a DPF700 panel mount device that is protected in instrument should be done by Qualified personnel Do not exceed voltage rating on the label located on the top of the instrument housing Always disconnect power before changing signal and power connections Do not use this instrument on a work bench without its case for safety reasons Do not operate this instrument in flammable or explosive atmospheres Do not expose this instrument to rain or moisture Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operati
3. 9456 1250938 FRANCE BREVET No 91 12756 SPAIN 2039150 2048066 UK PATENT No GB2 249 837 GB2 248 954 GERMANY DE 41 34398 C2 OTHER INTERNATIONAL PATENTS PENDING Where Do I Find Everything I Need for Process Measurement and Control M1799 1203 OMEGA Of Course Shop on line at www omega com TEMPERATURE 4 Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies A Wire Thermocouple amp Thermistor L Calibrators amp Ice Point References 24 Recorders Controllers amp Process Monitors A Infrared Pyrometers PRESSURE STRAIN AND FORCE A Transducers amp Strain Gauges lA Load Cells amp Pressure Gauges A Displacement Transducers A Instrumentation amp Accessories FLOW LEVEL 24 Rotameters Gas Mass Flowmeters amp Flow Computers lA Air Velocity Indicators A Turbine Paddlewheel Systems L Totalizers amp Batch Controllers pH CONDUCTIVITY 4 pH Electrodes Testers amp Accessories 24 Benchtop Laboratory Meters 4 Controllers Calibrators Simulators amp Pumps A Industrial pH amp Conductivity Equipment DATA ACQUISITION lA Data Acquisition amp Engineering Software 24 Communications Based Acquisition Systems IY Plug in Cards for Apple IBM amp Compatibles 24 Datalogging Systems 24 Recorders Printers amp Plotters HEATERS 24 Heating Cable A Cartridge amp Strip Heaters 4 Immersion amp Band Heaters Flexible Heaters A Laboratory Hea
4. LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is re
5. l sales omega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 7056 9398 0 FAX 49 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom TEL 44 161 777 6611 FAX 44 161 777 6622 Toll Free in England 0800 488 488 e mail sales omega co uk It is the policy of OMEGA to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for patient connected applications This device is marked with the international caution symbol It is important to read the Setup Guide before installing or commissioning this device as the guide contains important information relating to safety and EMC This device is marked with the international caution symbol It is important to read the Setup Guide before installing or commissioning this device as the guide contains important information relating to safety and EMC MANUAL OBJECTIVES This manual
6. n Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGAS control Components which wear are not warranted including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF
7. ng temperature rating Use electrical wires with adequate size to handle mechanical strain and power requirements Install without exposing bare wire outside the connector to minimize electrical shock hazards 2 1 INSTALLING THE DUAL RELAY OPTION BOARD To install the dual relay option board follow these steps refer to the Figure 2 1 CAUTION The meter has no power on switch so it will be in operation as soon as you apply power IMPORTANT Disconnect the power from the unit before installing this option board 1 Hold the board in a horizontal position with the TB3 connector facing towards the rear of the meter 2 Line up the 3 connectors located on the back side of the board with pin groups J3 J4 and J5 on the mother card 3 Push connectors down to secure on relay board TB3 RELAY 000000 NC1 N01 CM1 NC2 NO2 CM2 RELAY BD Figure 2 1 Dual Relay Option Board 2 2 SETTING UP THE DUAL RELAY OPTION BOARD You may enter a setpoint from 99999 to 999999 with a decimal point in any of the following positions 9 9 9 9 9 9 After applying the scale factor and offset the displayed measurement is compared to the setpoint values LO ALARM Displayed value is less than Setpoint LO HI ALARM Displayed value is more than Setpoint HI HYSTERESIS Relay 2 is energized when display value is more than Setpoint HI Relay 2 is not energized when display value is less than Setpoint LO Setpoint Example Setp
8. ntact of relay 1 TB3 2 is a normally open contact of relay 1 TB3 3 is a common contact of relay 1 TB3 4 is a normally closed contact of relay 2 TB3 5 is a normally open contact of relay 2 TB3 6 is a common contact of relay 2 5 RELAY1 TB3 4 lt 1 TB3 2 lt NO1 K1 SETPOINT LOW OUTPUT TB3 8 M1 RELAY2 TB3 4 2 ri HYSTERESIS OUTPUT 5 02 pss d 6 M2 SETPOINT HIGH OUTPUT Figure 2 3 Electrical Wiring for Relay Connections RELAY 1 RELAY 2 NC1 NO1 CM1 NC2 NO2 CM2 EXTERNAL LOAD Figure 2 4 Dual Relay Connections 3 1 RELAY OUTPUT OPTION BOARD SPECIFICATIONS 2 Form C on off relays Configurable for latched and unlatched by software Max Current 5 Amps resistive load Max Voltage 250 Vac or 28 NOTES MADE USA WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA Warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that customers receive maximum coverage on each product If the unit should malfunction it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue a
9. oint HI is 500 0 and Setpoint LO is 100 0 Reading changes from 0 to 600 and back to 0 Figure 10 2 on the following page illustrates Table 2 1 Table 2 1 Setpoint Example Alarm Status Reading LO Relay 1 Hl Relay2 _ Pn Ho xo oO _ of On 100 500 on SON 1 GEM NM NU CENE 2 2 SETTING UP THE DUAL RELAY BOARD Continued STANDARD RELAY OPTION 708772 RELAY ON OR ENERGIZED 9 9 RELAY 1 LO RELAY 2 HI SETPOINT 0 RELAY 1 LO RELAY 2 HI RELAY OPERATION WITH HYSTERESIS VONZ RELAY ENERGIZED RELAY 1 LO RELAY 2 HI SETPOINT 0 9 9 500 1 RELAY 1 LO OFF OFF LIGA OF RELAY 2 HI Figure 2 2 Setpoint Example Illustration To convert Setpoint LO to a second high setpoint set software switch 3 of the configuration menu to 1 ConFIG XX1XXX LO ALARM becomes active when the reading is greater more positive than that setpoint To convert both setpoints to latched setpoints set software switch 2 of the configuration menu to 1 ConFIG X1XXXX When relays are energized they stay energized until a Reset either front panel or back connector reset 4 2 3 ELECTRICAL CONNECTION AND SPECIFICATION Each relay has a form contact Refer to Figure 2 1 and Figure 2 3 to locate contacts and 55 switch Install 55 to control Relay 2 with hysteresis action Install S5 B to control Relay 2 with setpoint TB3 1 is a normally closed co
10. shows you how to install and use the Dual Relay option board with the DPF700 meter In this manual we provide procedures for Setting up the Dual Relay option board Installing the Dual Relay option board Use this manual with you DPF700 manual M1676 NOTES and CAUTIONS Information that is especially important to note is identified by these labels NOTE WARNING CAUTION IMPORTANT NOTE provides you with information that is important to successfully setup and use the Programmable Digital Meter CAUTION or WARNING tells you about the risk of electric shock CAUTION WARNING or IMPORTANT tells you of circumstances or practices that can effect the meter s functionality and must refer to accompanying documents TABLE OF CONTENTS TT UNPACKING itech ah Pe a a es Se SE A ARP Ree iet 1 2 SAFETY CONSIDERATIONS eee 2 1 INSTALLING THE DUAL RELAY OPTION 2 2 SETTING UP THE DUAL RELAY OPTION BOARD 2 3 ELECTRICAL CONNECTION rre 3 1 RELAY OUTPUT OPTION BOARD SPECIFICATIONS FIGURES 2 1 DUAL RELAY OPTION BOARD 000000202 re 2 2 SETPOINT EXAMPLE ILLUSTRATION 00 00 0000 2 cee I n 2 3 ELECTRICAL WIRING FOR RELAY CONNECTION 2 4 DUAL RELAY CONNECTIONS sseeeesellel res TABLES 2 1 SETPOINT EXAMPLE s
11. sponsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult OMEGA for following information available BEFORE current repair charges Have the following information contacting OMEGA available BEFORE contacting OMEGA 1 P O number under which the product was 1 P O number to cover the COST PURCHASED of the repair 2 Model and serial number of the product under 2 Model and serial number of product and warranty and 3 Repair instructions and or specific problems 3 Repair instructions and or specific problems relative to the product relative to the product policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2003 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without prior written consent of OMEGA ENGINEERING INC PATENT NOTICE The Meter Case Bezel Design is a trademark of NEWPORT Electronics Inc registered in the U S USED UNDER LICENSE This product is covered by one or more of the following patents U S Pat No Des 336 895 5 274 577 CANADA 2052599 2052600 ITALY 124
12. ters ENVIRONMENTAL MONITORING AND CONTROL Metering amp Control Instrumentation A Refractometers A Pumps amp Tubing lA Air Soil amp Water Monitors 4 Industrial Water amp Wastewater Treatment A pH Conductivity amp Dissolved Oxygen Instruments 11689ML 99 Rev C