Home
NuTone QTXEN110SFLT User's Manual
Contents
1. Joist OR MODEL QTXEN110SFLT Nulone 1b Mount housing anywhere between 2 Attach damper Page 3 trusses joists or I joists using hanger bars Sliding hanger bars are provided to allow for accurate posi tioning of housing anywhere between framing They can be used on all types of framing I joist standard joist and truss construction and span up to 24 as MOUNTING CHANNEL 2 Attach the MOUNTING CHANNELS to the housing using the SCREWS supplied Make sure TABS face up as shown Use the set of channel mounting holes marked STD to mount the housing flush with the bottom of the drywall Use the other set of holes not marked to mount the housing flush with the top of the drywall HOLE FOR OPTIONAL BOTTOM EDGE OF FRAMING Extend HANGER BARS to the width of the framing Hold ventilator in place with the hanger bar tabs wrapping around the BOTTOM EDGE OF THE FRAMING NAIL ventilator to framing or fasten with screws not provided through HOLES near nails To ensure a noise free mount Secure hanger bars together with SCREWS or use a pliers to crimp mounting channels tightly around hanger bars 3 Install duct connector Snap damper duct con nector onto housing Make sure connector is flush with top of housing and damper flap falls closed Qo 0 an SLED A 6 inch round duc twork Connect 6 inch round ductwork to damper duct connector Run ductwork to a roof
2. cap or wall cap Tape all ductwork con nections to make them secure and air tight WIRING OPTION 1 Allows fan to operate in automatic mode or manual mode for odor control by cycling ON OFF switch MODEL 66V 66W P66V PE6W 3 FUNCTION CONTROL PURCHASE SEPARATELY NIGHT LIGHT ON OFF FAN AUTO OFF SWITCH BOX WIRING OPTION 2 Fan can be turned ON OFF or set to operate automatically MODEL 77DV 77DW P77DV P77DW 4 FUNCTION CONTROL PURCHASE SEPARATELY Go Q HUMIDITY CONTROL FAN ON OFF AUTO ON OFF LIGHT ON OFF NIGHT LIGHT BLK 120 VAC WHT LINE IN GRD SWITCH BOX 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams Nulone INSTALL GRILLE 6 Finish ceiling Install ceiling material Cut out around housing 7 Plug in wiring Plug wiring into the proper receptacles A a WY Al AI AS XB Wy FA 8 Attach grille to housing Squeeze grille springs and insert them into slots on each side of housing 9 Push grille against ceiling 10 Remove light lens Carefully insert a small flat blade screwdriver be tween grille and lens Pry lens out 11 Install light bulbs Insert fluorescent bulb supplied into its socket Purchase a 4W incandes ce
3. de la clave 99043590B
4. has a TIMER that can be adjusted from 5 to 60 minutes factory set at 20 minutes This TIMER controls the length of time that the fan re mains ON a after the sensor has stopped sensing a rise in humidity and the humidity level is below the user adjustable set point or b after being energized by cycling the power switch To adjust the TIMER 1 Disconnect power at service entrance 2 Through the grille locate the screwdriver slot marked TIMER 3 Using a small flat blade screwdriver carefully rotate the TIMER adjustment to desired setting from 5 to 60 minutes 4 Check operation by cycling the power switch as instructed under MANUAL ON WITH TIMED OFF or by turning on a humidity source until the fan turns on 5 Turn humidity source off and time the unit 6 Repeat above steps if necessary CLEANING amp MAINTENANCE For quiet and efficient operation long life and attractive appearance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The impeller should also be replaced SENSOR CLEANING The humidity sensor is mounted in the grille The sensor will operate most reliably when cleaned occasionally as follows 1 Disconnect power at service entrance 2 Remove the grill
5. ADO El ventilador con sensor de humedad tiene una caracter stica opcional de operaci n Para el control del olor o del vapor se puede energizar el ventilador al ciclar apagar y encender el conmutador de alimentaci n Una vez que se ha energizado de esta manera el ventilador perman ecer encendido durante el per odo establecido en el TEMPORIZADOR TIMER por el usuario de 5 a 60 minutos Este periodo se establece en f brica en 20 minutos Para energizar manualmente el ventilador 1 Si el conmutador de alimentaci n ya est en encendido proceda con el paso 2 de otra manera encienda el conmutador de alimentaci n durante m s de 1 segundo 2 Apague el conmutador de alimentaci n por menos de 1 segundo 3 Vuelva a encender el conmutador de alimentaci n el ventilador se encender AJUSTE DE LA SENSIBILIDAD La SENSIBILIDAD es ajustada en f brica para la mayor a de las aplicaciones de regadera Sin embargo si el ventilador se encuentra en el rea de la tina o se est usando para el control de la humedad es posible que se necesite aumentar la SENSIBILIDAD hasta el m ximo MAX Si el control est respondiendo con demasiada frecuen cia a condiciones ambientales cambiantes quiz s sea necesario ajustarlo a una SENSIBILIDAD menor MIN Para ajustar la SENSIBILIDAD 1 Desconecte la energ a en la entrada de servicio 2 A trav s de la rejilla local
6. CI protected circuit required or within 5 feet of shower head Locate unit away from heating or cooling sources which can affect humidity levels e Do not locate near window Unit may respond to the outdoor humidity level e Unit must be installed in ceiling to properly sense moisture e Locate unit only on flat ceilings up to 12 feet high for proper sensing e The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed 2 Plan the wiring e Plan to supply the unit with proper line voltage and appropriate power cable Power cable should be routed to the switch box first and then to the unit See CONNECT WIRING on page 3 e Do not operate this unit with a speed control Damage to the sensor unit will result e Light or night light may be installed with a wall mounted motion control INSTALL HOUSING amp DUCT 1a Mount housing to joist or I joist Use a pliers to bend housing TABS out to 90 Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with four 4 screws or nails Screw or nail housing to joist through lowest holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist SPACER use for mounting to
7. E se extienden hasta 61 cm e Ubique la unidad lejos de fuentes de calefacci n o a i enfriamiento que puedan afectar los niveles de humedad H CUBIERTA e No la ponga cerca de una ventana La unidad puede CABLE xo EL CTRICO Va om responder a los niveles de humedad del exterior e La unidad se debe instalar en el cielo raso para CUBIERTA detectar adecuadamente la humedad 5 e Ubique la unidad s lo en cielos rasos planos con altura de MATERIAL DEL pp i MEET a aa ess hasta 3 6 m 12 pies para obtener una detecci n CIELO RASO LLORO REJILLA adecuada de medad 7 e El ventilador funcionar m s eficientemente cuando se Montaje de la cubierta en Montaje de la cubierta en cualquier ubique en un rea en la que se necesite el tramo m s viguetas T parte entre las viguetas I por corto de conductos posible y un n mero m nimo de codos medio de barras de suspensi n 2 Planifique la conexi n el ctrica CABLE CABLE EL CTRICO EL CTRICO BARRAS DE SUSPENSION e Alimente la unidad con la tensi n de l nea y el cable ni se extienden hasta 61 cm z z z o DE 24 pulg el ctrico apropiados El cable el ctrico debe tenderse primero hacia la caja de interruptores y seguidamente a aie a la unidad consulte la secci n CONEXION ELECTRICA de la p gina 3 e No utilice esta unidad con un control de velocidad porque CUBIERTA se podr a da ar el sensor e La l mpara o la l mpara de noche
8. ECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify NuTone at the address or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 MODEL QTXEN110SFLT Page 4 SERVICE PARTS Replacement parts can be ordered on our website Please visit us at www O 0 YO 01 RA ON nutone com 97016466 97016450 98010102 99170245 97017086 99020284 99080580 99100491 97017084 99250959 99260558 97017088 97016864 99260423 97016967 99140199 97016888 99111345 99111293 QTNHB1 99271344 SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove screw 4 from motor plate 9 flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a straight blade screwdriver into slot in housing next to t
9. ENSI N 4 OPCI N DE CONEXI N n 1 Permite que el ventilador funcione en modo Fije los CANALES DE MONTAJE a la cubierta con los TORNIL autom tico o en el modo manual para el control del olor al ciclar el conmutador LOS incluidos Aseg rese de que las LENGUETAS est n de cara de ENCENDIDO APAGADO hacia arriba tal como se muestra Utilice el conjunto de orificios de CONTAOL DEG uno ones ise compa N montaje del canal marcados como STD para montar la cubierta al ras con la parte inferior de la tablarroca Utilice el otro conjunto T TEEN de orificios sin marca para montar la cubierta al ras con la parte ENCENDIDO APAGADO superior de la tablarroca LAMPARA L MPARA DE NOCHE ENCENDIDO APAGADO VENTILADOR AUTO APAGADO ORIFICIO PARA TORNILLO 2 MONTAJE OPCIONAL CON TORNILLO 4 i CONTROL DE L NEA NEGRO HUMEDAD DE ENTRADA BLANCO DE TIERRA 120V CA CAJA DEL UNIDAD CONMUTADOR OPCI N DE CONEXI N n 2 El ventilador se puede encenderse apagarse o ajustarse para que funcione autom ticamente MODELO 77DV 77DW P77DV P77DW CONTROL DE 4 FUNCIONES SE COMPRA POR SEPARADO VENTILADOR Q 0 VENTILADOR O ENCENDIDO APAGADO AUTO CONTROL DE HUMEDAD BORDE INFERIOR CLAVO 4 DE LAESTRUCTURA LAMPARA DE NOCHE ENCENDIDO APAGADO LAMPARA DE NOCHE Abra las BARRAS DE SUSPENSION hasta el ancho de la estructura ENCENDIDO Sostenga el ventilador en su siti
10. Nulone HUMIDITY SENSING To register this product visit www nutone com MODEL QTXEN110SFLT FAN FLUORESCENT LIGHT NIGHT LIGHT READ AND SAVE THESE INSTRUCTIONS WARNING A dl TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OB SERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the ser vice disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient airis needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to pre vent backdrafting Follow the heating equip ment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Re frigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do notdamage electr
11. TH TIMED OFF The humidity sensing fan has an additional operation feature For odor or vapor con trol the fan can be energized by cycling the power switch Once the fan has been energized in this manner it will remain on for the user adjustable TIMER period 5 to 60 minutes This period is factory set for 20 minutes To manually energize the fan 1 If fan power switch is already ON proceed to Step 2 otherwise turn power switch ON for more than 1 second 2 Turn fan power switch OFF for less than 1 second 3 Turn fan power switch back ON and fan will turn ON SENSITIVITY ADJUSTMENT The SENSITIVITY has been factory set for most shower applications However if the fan is in a tub area or is being used for dampness control the SENSITIVITY may need to be increased toward maximum MAX If the control is responding too often to changing environmental conditions movement toward less MIN SENSITIV ITY may be required To adjust the SENSITIVITY 1 Disconnect power at service entrance 2 Through the grille locate the screwdriver slot marked SENSITIVITY 3 Using a small flat blade screwdriver carefully rotate the SENSITIVITY adjustment toward MAX or MIN 4 Turn on power and check operation by turning on the shower or other humidity source until the fan turns on 5 Repeat above steps if necessary TIMER ADJUSTMENT The humidity sensing fan
12. ab and twist screwdriver Housing Duct Connector 6 Wiring Plate Screw 8 18 X 375 2 req d Wire Panel Harness Assembly Blower Wheel Motor Isolator 4 req d Motor Plate amp Control Assembly Washer 8 4 req d Nut Hex Lock 8 32 4 req d Blower Assembly includes key nos 6 thru 11 Ballast Assembly Nut Hex 8 32 2 req d Grille Assembly includes key nos 15 17 amp 20 Grille Spring 2 req d Bulb 42W Fluorescent Lens Spacer 2 supplied Hanger Bar Kit Sensor Wire Harness Order service parts by Part No not by Key No 99043590B Nulone VENTILADOR CON SENSOR DE HUMEDAD L MPARA FLUORESCENTE L MPARA DE NOCHE ADVERTENCIA A PAN PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS ELECTRICAS O LESIONES PERSONALES OBSERVE LAS SIGUIENTES PRECAUCIONES 1 Use la unidad s lo de la manera indicada por el fabricante Si tiene preguntas comun quese con el fabricante en la direcci n o el n mero telef nico que se incluye en la garant a 2 Antes de dar servicio a la unidad o de limpiarla interrumpa el suministro el ctrico en el panel de servicio y bloquee los medios de desconexi n del servicio para evitar que la electricidad se reanude accidentalmente Cuando no sea posible bloquear los medios de desconexi n del servicio fije firme mente una se al de advertencia tal como una etiqueta en un lugar visible del panel de servicio 3 Una o m s personas calificadas deben rea
13. cita de manera que las limitaciones antedichas pueden no aplicar a usted LA OBLIGACI N DE NuTone DE REPARAR O REEMPLAZAR A OPCI N DE NUTONE SER EL UNICO Y EXCLUSIVO RECURSO DEL COMPRADOR BAJO ESTA GARANT A NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES RESULTANTES O ESPECIALES QUE SURJAN DE O EN RELACI N CON EL USO O RENDIMIENTO DEL PRODUCTO Algunos estados no permiten la exclusi n o la limitaci n de da os incidentales o resultantes de manera que es posible que la limitaci n antedicha no se aplique en su caso Esta garant a le da derechos legales espec ficos y usted puede tener otros derechos que podr an variar entre los estados Esta garant a sustituye a todas las garant as anteriores Para tener derecho al servicio de la garant a usted debe a notificar a NuTone a la direcci n y n mero de tel fono que aparecen abajo b proporcionar el n mero de modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar el servicio de la garant a debe presentar comprobante de la fecha de la compra original NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 MODELO QTXEN110SFLT P gina 8 NOTA DE SERVICIO Para desmontar el conjunto del ventilador Desenchufe el motor 7 Saque el tornillo 4 de la brida de la placa del motor 9 Localice la LENGUETA nica de la placa de
14. e Use a dry dustcloth clean toothbrush or lightly vacuum to clean sensor and grille DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor Nulone TYPICAL INSTALLATIONS POWER CABLE HANGER BARS span up to 24 T JOIST SPACER BLOCK MOUNTING CEILING cy MATERIAL GRILLE JOIST CEILING GRILLE MATERAL Housing mounted to I joists Housing mounted anywhere between I joists using hanger bars POWER CABLE HANGER BARS POWER CABLE span up to 24 MOUNTING TABS HOUSING CEILING GRILLE CEILING MATERIAL JOIST CEILING CEILING GRILLE JOIST MATERAL Housing mounted anywhere between joists using hanger bars Housing mounted to joists POWER CABLE HANGER BARS span up to 24 HANGER BARS span up to 24 ia ites CEILING MATERAL GRILLE CEILING GRILLE MATERAL Housing mounted anywhere Housing mounted anywhere between trusses using between trusses using hanger hanger bars bars PLAN THE INSTALLATION 1 Choose the installation location ROOF CAP 6 ps vc a The location of your humidity sensing fan is very important Use the follow ing guidelines for best opera tion Purchase separatel R AZZ A WALL CAP E T N 6 IN ROU ND N ELBOW N anii y MODEL QTXEN110SFLT Page 2 Locate unit above GF
15. ical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 This unit must be grounded CAUTION A 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in flat ceilings only DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements Installer Leave this manual with the homeowner OPERATION The humidity control fan light and night light can be operated separately Use a 3 or 4 function wall control Do not use a dimmer switch to operate the humidity control or light See Connect Wiring for details SENSOR OPERATION The humidity sensing fan uses a sophis ticated humidity sensor that responds to a rapid to moderate user adjustable increases in humidity or b humidity above a user adjustable set point 50 100 relative humidity The humidity sensor may occasionally turn the fan ON when environmental conditions change If the fan continuously responds to changing environmental conditions SENSITIVITY adjustment may be required MANUAL ON WI
16. ice la ranura de destornillador rotulada SENSIBILIDAD SENSITIVITY 3 Usando un destornillador pequeno de punta plana gire cuidadosamente el ajuste de SENSIBILIDAD hacia la posici n maxima MAX o m nima MIN 4 Suministre energ a y revise el funcionamiento abriendo la regadera u otra fuente de humedad hasta que el ventilador se encienda 5 Repita los pasos anteriores si es necesario MODELO QTXEN110SFLT AJUSTE DEL TEMPORIZADOR El ventilador con sensor de humedad tiene un TEMPORIZADOR que se puede ajustar de 5 a 60 minutos establecido en f brica a 20 minutos Este TEMPORIZADOR controla el tiempo en que el ventilador permanece encendido a despu s de que el sensor deja de detectar un aumento en la humedad y el nivel de humedad es menor del punto de referencia ajustable por el usuario o b despu s de haberlo energizado al ciclar el conmutador de alimentaci n Para ajustar el TEMPORIZADOR 1 Desconecte la energ a en la entrada de servicio 2 A trav s de la rejilla localice la ranura de destornillador rotulada TEMPORIZADOR TIMER 3 Usando un destornillador peque o de hoja plana gire cuidadosamente el ajuste TEMPORIZADOR hasta el ajuste deseado de 5 a 60 minutos 4 Revise la operaci n ciclando el conmutador de alimentaci n de acuerdo con las instrucciones contenidas en la secci n MANUAL CON TIEMPO DE APAGADO o al encende
17. l motor se encuentra junto al recept culo Empuje hacia arriba cerca de la lengueta de la placa del motor al mismo tiempo que empuja hacia afuera el costado de la cubierta O bien introduzca un destornillador de punta recta en la ranura de la cubierta junto a la lengueta y gire el destornillador Pieza n Descripci n 97016466 Cubierta 97016450 Conector de conductor 15 cm 6 pulg 98010102 Placa de cableado 99170245 Tornillo n 8 18 x 0 375 se requieren 2 97017086 Conjunto del panel de cableado arn s 99020284 Rueda del ventilador 99080580 Motor 99100491 Aislador se requieren 4 97017083 Placa de motor y conjunto de control 99250959 Arandela n 8 se requieren 4 99260558 Tuerca hexagonal de seguridad n 8 32 se requieren 4 97017088 Conjunto del ventilador incluye claves n 6 a 11 97016864 Conjunto de reactancia 99260423 Tuerca hexagonal n 8 32 se requieren 2 97016967 Conjunto de la rejilla incluye las piezas de clave n 15 17 y 20 99140199 Resorte de la rejilla se requieren 2 97016888 Bombilla fluorescente 42 watts 99111345 Lente 99111293 Separador se suministran 2 QTNHB1 Juego de barra de suspensi n 99271344 Arn s de cables del sensor Se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio web Le rogamos visitarnos a www nutone com 2000 YO000 A4A0D0DN 1 1 Al hacer el pedido de una pieza de servicio se debe especificar el n mero de la pieza no el n mero
18. la lente Haga bombilla incandescente para palanca con el destornillador y l mpara de noche de 4 watts saque la lente y atorn llela a su recept culo Vuelva a colocar la lente GARANT A GARANT A LIMITADA DE TRES A OS DE NUTONE NuTone garantiza al consumidor comprador original de sus productos que tales productos estar n libres de defectos en materiales o mano de obra durante un per odo de tres a os a partir de la fecha de la compra original NO EXISTEN OTRAS GARANTIAS EXPRESAS NI IMPL CITAS INCLUIDAS PERO SIN LIMI TARSE A GARANTIAS IMPLICITAS DE COMERCIALIZACI N O IDONEIDAD PARA UN PROPOSITO PARTICULAR Durante este per odo de tres a os NuTone a su criterio reparar o reemplazar sin cargo alguno cualquier pieza o producto que se encuentre defectuoso bajo condiciones normales de uso y servicio ESTA GARANT A NO SE EXTIENDE A ARRANCADORES NI A TUBOS DE LAS L MPARAS FLUORES CENTES Esta garant a no cubre a mantenimiento y servicio normales ni b ning n producto o piezas que se hayan sometido a uso inadecuado negligencia accidente mantenimiento o reparaci n inadecuada no hecha por NuTone instalaci n incorrecta o instalaci n que vaya en contravenci n de las instrucciones de instalaci n recomendadas La duraci n de una garant a impl cita se limita al per odo de tres a os como se especifica para la garant a expl cita Algunos estados no permiten la limitaci n de la duraci n de una garant a impl
19. lizar el trabajo de instalaci n y el cableado el ctrico de acuerdo con todos los c digos y normas cor respondientes incluidos los c digos y normas de construcci n espec ficos de protecci n contra incendios 4 Se necesita suficiente aire para que se lleve a cabo una combusti n adecuada y la descarga de los gases a trav s del tubo de humos chimenea del equipo quemador de combustible a fin de evitar las contracorrientes Siga las directrices y las normas de seguridad del fabricante del equipo de calentamiento como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las auto ridades de los c digos locales 5 Al cortar o perforar a trav s de la pared o del cielo raso tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos 6 Los ventiladores con conductos deben siempre conectarse hacia el exterior 7 Esta unidad puede instalarse sobre una tina o ducha siempre que se conecte a un GFCI inter ruptor accionado por p rdida de conexi n a tierra en un circuito de derivaci n protegido 8 Esta unidad debe conectarse a tierra PRECAUCI N A S lo para usarse como medio de ventilaci n general No se use para descargar materiales ni vapores peligrosos o exp
20. losivos 2 Este producto est dise ado para instalarse sola mente en un cielo raso plano NO MONTE ESTE PRODUCTO EN LA PARED 3 Para evitar da os a los cojinetes del motor y rotores ruidosos y o no equilibrados mantenga la unidad de accionamiento al resguardo de rociados de yeso polvos de construcci n etc 4 L ase la etiqueta de especificaciones que tiene el producto para ver informaci n y requisitos adicio nales Aviso al instalador Deje este manual con el due o de la casa Para registrar este producto visite www nutone com OPERATION El control de humedad el ventilador la l mpara y la l mpara de noche pueden funcionar sepa radamente Utilice un control de pared de 3 4 funciones No utilice un reductor de intensidad para hacer funcionar el control de humedad o la l mpara vea los detalles en la secci n Conexi n el ctrica OPERACI N DEL SENSOR Este ventilador utiliza un avanzado sensor de humedad que responde a a aumentos r pidos a moderados de humedad ajustables por el usuario o b humedad superior a un punto de referencia establecido por el usuario humedad relativa de 50 a 100 Ocasionalmente el sensor de humedad puede encender el ventilador cuando cambian las condiciones ambientales Si el ventilador responde continuamente a las cambiantes condiciones ambi entales es posible que se requiera el ajuste de la SENSIBILIDAD SENSITIVITY MANUAL CON TIEMPO DE APAG
21. nt night light bulb and screw it into its socket Replace lens WARRANTY NUTONE THREE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE During this three year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subjectto misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the three year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NuTone S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONN
22. o envolviendo las leng etas de NEK ES LAMPARA la barra de suspension alrededor del BORDE INFERIOR DE LA oes ance ae ESTRUCTURA DE aa 120V CA CLAVE el ventilador a la estructura o suj telo con tornillos no incluidos CAJA DEL a trav s de los ORIFICIOS que est n cerca de los clavos ella ind Para lograr un montaje silencioso Acople y fije las barras de 4 Conecte los cables el ctricos suspensi n con TORNILLOS o doble con un alicate los canales de Extienda el cableado de la casa de 120 V CA al lugar de la montaje bien justos alrededor de las barras de suspensi n instalaci n Utilice una conexi n aprobada por UL para afianzar el cableado de la casa a la placa de cableado Conecte los cables tal como se ilustra en los diagramas de cableado Nulone INSTALE LA REJILLA 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta 7 Conecte el cableado Enchufe las conexiones en los recept culos adecuados E NS ao Y FS SS N JF Te Aan 8 Acople la rejilla ala 9 Empuje la rejilla cubierta contra el cielo raso Apriete los resortes de la rejilla e ins rtelos en las ranuras que se encuentran a cada lado de la cubierta 10 Quite la lente de la 11 Instale las bombillas l mpara Inserte la bombilla fluores Con cuidado inserte un cente suministrada en su destornillador plano peque o recept culo Compre una entre la rejilla y
23. podr a instalarse con MATERIAL DEL Reja VIGUETA DE VIGUETA DE un control de movimiento montado en la pared CIELO RASO TECHO MATERIAL DEL REJILLA TECHO CIELO RASO Montaje de cubierta en Montaje de la cubierta en cualquier viguetas parte entre las viguetas por N STAL E LA C U B E RTA Y medio de barras de suspensi n EL CONDUCTO CABLE SUSPENSI N SE ike BARRAS DE SUSPENSION ene se extienden an 1a Instale la BARRAS DE hasta 61 cm 24 pulg AS cubierta cuna en las viguetas o viguetas T n alicat SD REA SO PELA as LENGUETAS 7 7 A n de la cubierta a un Montaje de la cubierta en cualquier Montaje de la cubierta en cualquier ngulo de 90 Sos parte entre armaduras por medio parte entre armaduras por medio tenga la cubierta en de barras de suspensi n de barras de suspensi n su lugar de manera SEPARADOR A 7 que las leng etas se usa para el montaje a la de la cubierta hagan PLANIFICACION DE LA INSTALACION contacto conta parte inferior de la vigueta Para el montaje de la 1 Elija el A J d x L is cubierta se utilizan toe e cuatro 4 tornillos instalaci n o clavos Atornille o CONDUCTO clave la cubierta a Laubi nd AEEA la vigueta a trav s P a upicacion qe es Z de los orificios m s VIGUETA su ventilador bajos de cada brida con sensor de de montaje y segui humedad es Porr damente a trav s de los m s altos muv importan
24. r una fuente de humedad hasta que el ventilador se encienda 5 Luego apague la fuente de la humedad y mida el tiempo de operaci n de la unidad 6 Repita los pasos anteriores si es necesario LIMPIEZA Y MANTENIMIENTO Para lograr un funcionamiento silencioso y eficiente como tambi n larga vida y una apariencia atractiva del producto baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar aceite Si los cojinetes del motor est n haciendo ruido excesivo o inusitado reemplace el motor con el motor de servicio exacto Tambi n debe reemplazar el impulsor LIMPIEZA DEL SENSOR El sensor de humedad est montado en la rejilla El funcionamiento del sensor ser m s fiable si se limpia ocasionalmente Para ello haga lo siguiente 1 Desconecte la energ a en la entrada de servicio 2 Quite la rejilla Limpie el sensor y la rejilla con un pa o sacudidor seco o un cepillo de dientes limpio o asp relos ligeramente NO USE PA OS ABRASIVOS ALMOHADILLAS DE LANA DE ACERO NI POLVOS ABRASIVOS 3 NO USE sprays limpiadores solventes ni agua en o cerca del sensor N ulo ne MODELO QTXEN110SFLT P gina 6 INSTALACIONES T PICAS e Coloque la unidad sobre o dentro de una distancia de 1 5 m 5 pies de la cabeza de la regadera se requiere un circuito Mu D DE ESOS BARRAS DE SUSPENSI N protegido vee un ace
25. te NY OO T NOTA El montaje en la VIGUETA T mostrada requiere utilizar Siga es linea N SEPARADORES incluidos entre el orificio m s alto de cada I I N py mientos para PRAT a EN TADE brida de montaje y la vigueta i obtener el mejor secompRa CODO REDONDO eS y Nse O BIEN funcionamiento POR SEPARADO DE 15 CM N Nulone 1b Instale la cubierta en cualquier parte entre las armaduras viguetas o viguetas I por medio de barras de suspension Se proporcionan barras de suspensi n deslizantes para facilitar la colocaci n adecuada de la cubierta en cualquier parte entre la estructura Estas barras se adaptan a toda clase de estructuras construcciones de viguetas I viguetas est ndar y armaduras y 2 Acople el conectador MODELO QTXEN110SFLT P gina 7 del regulador de tiro conducto Conecte a presi n el conectador del regulador de tiro conducto en la cubierta Aseg rese de que el conec tor est al ras con la parte se extienden a un m ximo de 61 cm 24 pulg superior de la cubierta y que la aleta del regulador caiga LENGUETA cerrada 3 Instale el conducto redondo de 15 cm 6 pulg Conecte el conducto redondo de 15 cm 6 pulg al conector del regula dor conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas CANAL DE y hacerlas herm ticas al aire BARRA DE MONTAJE 2 SUSP
Download Pdf Manuals
Related Search
Related Contents
Craftsman 40-In. Service Parts Manual Alvarion BreezeACCESS EZ Defi-Link Display取扱説明書 mm [mm [1 um um [11115151116 |])|]1] T9000 Premium Throttle 盲人用具カタログ SMAN320 - 3-Port Digital Manifold Copyright © All rights reserved.
Failed to retrieve file