Home
NuTone 9422P User's Manual
Contents
1. LB HEATER FAN ONLY e Plug in permanently lubricated motor e Quiet polymeric blower wheel e Polymeric damper duct connector with 1 5 8 long tapered sleeve and no metallic clatter e Unit may function with bulbs and fan controlled together bulbs and fan controlled separately or EACH bulb and fan controlled separately SPECIFICATIONS MODEL voLTs amps watTs SONES _CFM_ 9422P 120 43 505 3 5 70 3 4 5 545 4 Round Total Connected Load BR40 size Infrared Bulbs Use house wiring rated 60 C min 2100 c HVI 2100 CERTIFIED RATINGS comply with new testing technologies LN and procedures prescribed by the Home Ventilating Institute for off the shelf products as they are available to consumers Product Vi performance is rated at 0 1 in static pressure based on tests conducted in AMCA s state of the art test laboratory Sones are a CERTIFIED measure of humanly perceived loudness based on laboratory measurements NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Product specifications subject to change without notice REFERENCE ary REMARKS Project Location Contractor Submitted by Date 50G 99042989E
2. Nulone SPECIFICATION SHEET MODELS 9422P amp 9427P INFRARED BULB HEATERS Quick and efficient these twin bulb heaters provide TYPICAL SPECIFICATION ME ec ee uve temperature contrelyounees Bulb heater shall be NuTone Model 9422P NuTone Model FEATURES a 9427P i Hed ne a Heater shall have corrosion resistant steel housing and e Adjustable mounting brackets that span up to 24 adjustable mounting brackets e Housing can be adjusted vertically after ceiling is finished Unit must use 2 250W BR4O0 size infrared bulbs Bulb g a a ed ee ta se etic Heater to be U L Listed Suitable for use in insulated ceilings using the following controls Type I C Model 59W V 60 Minute Time Control l Model 61W V 15 Minute Time Control MODEL 9427P BULB HEATER FAN ONLY l Model 62W V 60 Minute Time Control with 2 Toggle Motor assembly to be removable and permanently lubricated Switches Model 9427P only Model 63W V 60 Minute Time Control w Toggle Switch Model 66W V Heat Fan Light Control Model 9427P only Heater and ventilator to operate separately or in combination Model 68W V Two Function Control e Suitable for use in insulated ceilings Type I C Non metallic damper duct connector to be included Air delivery shall be no less than 70 CFM and sound level no greater than 3 5 Sones All air and sound ratings shall be certified by HVI MODEL 9427P BU
Download Pdf Manuals
Related Search
Related Contents
viscosity cups MANUAL DEL USUARIO USER MANUAL - Nordisk Musik AB Valueline VLMP11955W mobile device charger CANopenマスタユニットハードウェアマニュアル取扱説明書 Ferro com gerador de vapor e pressão máx. da bomba 5.2. User regulation on testo Comfort Software CFR 4 level Samsung E2550D Kasutusjuhend Copyright © All rights reserved.
Failed to retrieve file