Home

Nortel Networks Centillion 1600 User's Manual

image

Contents

1. 77 Opening the Contvity GOW os sue que data eee dd ake Lhe nd dak De 78 Contivity 600 system board layout 80 Installing Contivity 600 option cards 81 MSN BOUON ss vesersedinrsbinidiste in sente bie stat dere sed 83 DPC Re 85 302283 E Rev 00 11 Figures Figure 1 Removing the Contivity 4600 front bezel 20 Figure 2 Contivity 4600 front components 21 Figure 3 Sample Contivity 4600 system board 22 Figure 4 Installing Contivity 4600 LAN WAN and hardware accelerator cards 23 Figure 5 Installing Contivity 4600 DIMMs 25 Figure 6 Removing a Contivity 4600 power supply 26 Figure 7 Removing a Contivity 4600 hard disk drive 28 Figure 8 Removing the Contivity 4500 front bezel 32 Figure9 Contivity 4500 front components 33 Figure 10 Sample Contivity 4500 system board 35 Figure 11 Installing 4500 LAN WAN and hardware accelerator option cards 37 Figure 12 Installing Contivity 4500 DIMMs 38 Figure 13 Removing a Contivity 4500 power supply 40 Figure 14 Removing a Contivity 4500 hard disk drive 42 Figure 15 Removing
2. Installing Hardware Options for the Contivity VPN Switch 38 Chapter 2 Contivity 4500 Option Installation Installing Contivity 4500 DIMMs Figure 12 shows you how to unlock a Dual Inline Memory Module DIMM in the Contivity 4500 and remove or install a DIMM Install a DIMM in the next available slot for example if the DIMM 1 slot is populated then add the next DIMM to the DIMM 2 slot Figure 12 Installing Contivity 4500 DIMMs Rear panel of switch Phillips screw Alignment Support bracket captive screws oN Locking lever CS450015A 302283 E Rev 00 Chapter 2 Contivity 4500 Option Installation 39 To install a DIMM into the Contivity 4500 follow these steps 1 2 3 Turn off the switch Remove the power cords Unscrew the slide out tray at the back of the unit and pull it out using the thumb screws Remove the support bracket by loosening the two secured captive screws and the rear Phillips screw Press down the locking levers on both sides of the next available DIMM slot to allow the new DIMM to be inserted Place the new DIMM in the slot making sure to properly position the DIMM s alignment keys Make sure the DIMM is pressed firmly into the socket Pull up the locking levers on both sides of the DIMM and snap the DIMM into the socket Replace the support bracket by tightening the two secured captive screws and the rear Phillips screw Push in the slide out tr
3. Opening the Contivity 2600 To access the Contivity 2600 disk drive for system recovery operations you must first remove the switch s front bezel To install LAN or WAN cards install hardware accelerator PCI cards install additional memory replace power supplies or replace hard disk drives you must remove the front bezel and then remove the switch s top cover You may find it easier to work on the system when it has been removed from the rack Installing Hardware Options for the Contivity VPN Switch 58 Chapter 4 Contivity 2600 Option Installation Removing the Contivity 2600 front bezel the chassis intrusion alarm whether or not the switch is turned on This intrusion is reported to the system log file Note Removing the front bezel on the Contivity 2600 system activates gt You must remove the bezel to insert the recovery diskette Note that you do not need to turn off the switch if you are only removing the front bezel Figure 24 shows you how to remove the front bezel from the switch not use the part labeled with the Nortel Networks logo and the LEDs as a handle Caution When handling the switch outside of the rack mount shelf do Figure 24 Removing the Contivity 2600 front bezel 000000 JM OB666000 CS260015A 302283 E Rev 00 Chapter 4 Contivity 2600 Option Installation 59 The first few times you remove the front bezel it will
4. Example If the command syntax is show at lt valid route gt valid route is one variable and you substitute one value for it Indicates command syntax and system output for example prompts and system messages Example Set Trap Monitor Filters Shows menu paths Example Protocols gt IP identifies the IP option on the Protocols menu Installing Hardware Options for the Contivity VPN Switch 16 Preface vertical line asterisk Acronyms Separates choices for command keywords and arguments Enter only one of the choices Do not type the vertical line when entering the command Example If the command syntax is show ip alerts routes you enter either show ip alerts or show ip routes but not both Indicates a trademark See the Title Page for trademark information Example Contivity This guide uses the following acronyms CSU DSU DIMM DTE ERC FTP HSSI HTTP IP IPMI LAN LED PCI PDN SCSI SNMP TCP Channel Service Unit Digital Service Unit Dual inline memory module Data Terminal Equipment Express Routing Code File Transfer Protocol high speed serial interface HyperText Transfer Protocol Internet Protocol Intelligent Platform Management Interface Local area network Light emitting diode Peripheral component interconnect Public data network Small computer system interface Simple Network Management Protocol Transmission Control Protocol 302283 E Rev 00 P
5. O O O 3 O O 3 ie e Power supplies CS450012A Installing Hardware Options for the Contivity VPN Switch 34 Chapter 2 Contivity 4500 Option Installation Contivity 4500 system board layout This section describes installing option cards onto the system board Warning Only Nortel Networks trained service personnel should A change existing hardware configurations Improper handling of internal components or assemblies with the power connected could cause severe injury Note Wear an antistatic band when handling electronic components for the switch to avoid damaging them Warning Turn off the switch and unplug both power cords before A installing LAN and WAN cards or system memory 302283 E Rev 00 Chapter 2 Contivity 4500 Option Installation 35 Figure 10 shows the Contivity 4500 system board in particular the DIMMs and option card slots Figure 10 Sample Contivity 4500 system board 00000000 00000000 DOO0000000000000000000000 OOO0000000000000000000000 PCI 6 G 5 G Sse SS slots CS450013A Installing Hardware Options for the Contivity VPN Switch 36 Chapter 2 Contivity 4500 Option Installation Installing Contivity 4500 LAN WAN and hardware accelerator option cards This section describes how you install option cards into the Contivity 4500 option card slide out tray The following procedure is for Nortel Networks tr
6. 50 Replacing a Contivity 4000 disk drive 52 Installing Contivity 2500 2000 4000 DIMMs 54 RIGOR Obs ses 159669465044 e het S45 et SET er OA As HERE ARES 55 Chapter 4 Contivity 2600 Option Installation 57 Opening he Contivity 2600 ae a Chad 6 Ra DR ER RR RR 57 Removing the Contivity 2600 front bezel 58 Removing the Contivity 2600 top cover 59 Contivity 2600 system board layout 60 Installing LAN WAN and hardware accelerator option cards 62 Installing Contivity 2600 DIMMs 64 Memory Option c ccccnceneseacareeyeee eo t krer OR M OR RE RR EWS 65 Chapter 5 Contivity 1600 Option Installation 67 Opening the Contivity 1600 onic cea due aa names de ba dia eee qd 67 Removing the Contivity 1600 front bezel 68 Removing the Contivity 1600 top cover 69 Contivity 1600 system board layout 71 Installing Contivity 1600 option cards 72 Installing Gontivity 1800 DIMME s s ritsu date RES IR RER ee DURE 75 Memo COUR D rE NETERA EARTEN bE a ENDA 76 Chapter 6 Contivity 600 Option Installation
7. 6 Slide the option card into the intended slot as shown in Figure 35 Make sure the card seats firmly and evenly into the card slot If the card is not seated properly it will not work Installing Hardware Options for the Contivity VPN Switch 74 Chapter 5 Contivity 1600 Option Installation Figure 35 Installing Contivity 1600 option cards Option card slot Option card Motherboard CS160019A 7 Replace the card and screw 8 Replace the top cover 9 Replace the front bezel 10 Reconnect the power cord 11 Turn on the switch 302283 E Rev 00 Chapter 5 Contivity 1600 Option Installation 75 Installing Contivity 1600 DIMMs Figure 36 shows you how to unlock a DIMM and remove or install the DIMM in the next available slot for example if the DIMM 1 slot is populated than add the next DIMM to the DIMM 2 slot Figure 36 Installing Contivity 1600 DIMMs Alignment keys To remove DIMMs pull back locking levers and pull out DIMM To install DIMMs pull back locking levers and push in DIMM Locking lever CS160008A Installing Hardware Options for the Contivity VPN Switch 76 Chapter 5 Contivity 1600 Option Installation To replace a DIMM follow these steps a fF O N Oo 9 Turn off the switch Remove the power cord as shown in Figure 30 Remove the front bezel as shown in Figure 29 Remove the top cover as shown in Figure 31 Pres
8. An Express Routing Code ERC is available for many Nortel Networks products and services When you use an ERC your call is routed to a technical support person who specializes in supporting that product or service To locate an ERC for your product or service go to the www12 nortelnetworks com URL and click Express Call Routing at the bottom of the page 302283 E Rev 00 19 Chapter 1 Contivity 4600 Option Installation This section describes how to install or replace hardware components for the Contivity 4600 Caution Wear an antistatic band when handling electronic components for the switch to avoid damaging them Warning Turn off the switch and unplug both power cords before A installing LAN and WAN cards or system memory Opening the Contivity 4600 To replace power supplies replace hard disk drives or access the diskette drive for system recovery operations you must remove the switch s front bezel Note Removing the front bezel on the Contivity 4600 activates the chassis intrusion alarm on power only This intrusion is reported to the system log file The first few times you remove the front bezel it might seem to resist removal This is simply because the ball stud and sockets are new After a few times removal is easier Remove the switch front bezel as follows 1 Inserta flat head screwdriver into the slots on the lower left and right sides of the chassis and pry the bezel forward
9. Slide your fingers between the front bezel and the switch Pull the bezel forward firmly separating the ball studs on the bezel from the sockets on the chassis Installing Hardware Options for the Contivity VPN Switch 20 Chapter 1 Contivity 4600 Option Installation Figure 1 shows you how to remove the front bezel from the Contivity 4600 You do not need to turn off the switch to remove the front bezel when installing a power supply or hard disk drive Figure 1 Removing the Contivity 4600 front bezel Using a phillips screwdriver rotate screws a quarter turn anti clockwise top right and left corners then separate ball stud on bezel from socket on chassis middle of both sides and bottom right and left corners we CS460005A 302283 E Rev 00 Chapter 1 Contivity 4600 Option Installation 21 Figure 2 shows the Contivity 4600 front components Figure 2 Contivity 4600 front components pese i ae ee ne ce Q Q D EPa o HE Ri oe aie ae fl lh fe Oo o o o ll o o W o LL TR RE ka T jl H hyll Milh H ul Power supplies CS460006A Installing Hardware Options for the Contivity VPN Switch 22 Chapter 1 Contivity 4600 Option Installation Contivity 4600 system board layout This section shows the Contivity 4600 system board Warning Only Nortel Networks trained service personnel should A change existing hardware configurations Improper handli
10. 70 Contivity 1600 system board 71 Removing the Contivity 1600 power cord 72 Installing Contivity 1600 LAN WAN option cards 73 Installing Contivity 1600 option cards 74 Installing Contivity 1600 DIMMs 75 Removing the bottom screws 79 Removing the system from the chassis 80 Contivity 600 system board 81 Replacing the system into the chassis 82 302283 E Rev 00 13 Preface This document describes how Nortel Networks trained service personnel can install or replace hardware components for models 4600 4500 4000 2600 2500 2000 1600 and 600 of the Contivity products The options include Installing LAN and WAN option cards Installing hardware accelerator PCI cards Adding or replacing memory Replacing a power supply 4600 4500 and 4000 only Replacing a hard disk drive 4600 4500 and 4000 only To install LAN WAN or hardware accelerator PCI cards and for system recovery operations you must remove the front bezel the top cover and or the rear T O panel tray depending on the type of Contivity product you are servicing The procedures for each Contivity model are described in the following chapters Warning Only Nortel Networks trained service
11. Unscrew the slide out tray at the back of the unit and pull it out using the thumb screws Remove the support bracket by loosening the two secured captive screws and the rear Phillips screw Press down the locking levers on both sides of the next available DIMM slot Place a new DIMM in the slot making sure to properly position the DIMM s alignment keys as shown in Figure 5 302283 E Rev 00 Chapter 1 Contivity 4600 Option Installation 25 Figure 5 Installing Contivity 4600 DIMMs Locking lever CS460009A 7 Pull up the locking levers on both sides of the next available DIMM and snap the DIMM into its socket 8 Replace the support bracket by tightening the two secured captive screws and the rear Phillips screw 9 Push in the slide out tray and tighten the thumb screws Replacing a Contivity 4600 power supply To remove the power supply 1 Remove the front bezel as shown in Figure 1 2 Use a flat head screwdriver to unscrew the top and bottom power supply screws as shown in Figure 6 Installing Hardware Options for the Contivity VPN Switch 26 Chapter 1 Contivity 4600 Option Installation Figure 6 Removing a Contivity 4600 power supply CS460010A Grab the handle and pull the power supply firmly until the device disengages Be careful of the sharp sheet metal edges Insert the new power supply Make sure it seats firmly in its socket and is locked in Be sure the green power LED on the front of
12. Installation This section describes how to install or replace hardware components for the Contivity 2500 2000 and 4000 Warning Wear an antistatic band when handling electronic AN components for the Contivity switch to avoid damaging them Note Turn off the Contivity switch and unplug it before installing LAN or WAN cards or system memory Opening the Contivity 2500 2000 4000 To install LAN or WAN cards install hardware accelerator PCI cards install additional memory replace power supplies or replace hard disk drives you must remove the front bezel and then remove the switch s top cover You may find it easier to work on the system when it has been removed from the rack Removing the Contivity 2500 2000 4000 front bezel To access the Contivity 2500 2000 4000 disk drive for system recovery operations you must first remove the switch s front bezel Figure 15 shows you how to remove the front bezel and top cover from the Contivity 2500 2000 4000 Note You do not need to turn off the switch to remove the front bezel p Installing Hardware Options for the Contivity VPN Switch 44 Chapter 3 Contivity 2500 2000 4000 Option Installation Figure 15 Removing the Contivity 2500 2000 4000 front bezel Slide fingers behind front bezel and firmly pull forward in the direction of arrows Front Bezel The first few times you remove the front bezel it will be rather difficult to remove This is bec
13. a disk drive Software First save any data that has not yet been saved to the hard disk from the disk cache 1 Launch a Web browser to the switch and go to the Admin gt File System display 2 Click the button Prepare selected device for removal Hardware Remove the switch s front bezel as shown in Figure 8 and then follow these steps 1 Insert and turn the hard disk drive key to the right The LED becomes a U for unlocked NOTE Turning the key shuts off the power to the hard disk drive gt 2 Pull the handle to remove the hard disk drive as shown in Figure 14 Installing Hardware Options for the Contivity VPN Switch 42 Chapter 2 Contivity 4500 Option Installation Figure 14 Removing a Contivity 4500 hard disk drive Insert and turn key then remove hard disk by handle CS460011A 3 Insert the replacement hard drive fully and lock it by turning the key clockwise Make sure the hard disk drive LED shows the proper drive number Replace the front bezel Reload the software on the disk Refer to Using the Recovery Diskette in Installing the Contivity 4600 for more information on using the recovery diskette Software Enable the switch by following these steps 1 Use your Web browser to navigate to the switch and go to the Admin File System display 2 Click on the drive and click the Enable button 302283 E Rev 00 43 Chapter 3 Contivity 2500 2000 4000 Option
14. be rather difficult to remove This is because the ball studs and socket clips are new After a few times removal is easier To remove the front bezel you need a Phillips screwdriver 1 Tum each of the two screws on the front bezel a quarter turn counter clockwise 2 Grip the two handles and pull the bezel towards you firmly to unsnap it from the chassis Removing the Contivity 2600 top cover To remove the cover to install LAN WAN or hardware accelerator cards or to install additional memory you must remove the switch s front bezel and then you must remove the switch s top cover Figure 25 shows you how to remove the top cover from the switch Installing Hardware Options for the Contivity VPN Switch 60 Chapter 4 Contivity 2600 Option Installation Figure 25 Removing the Contivity 2600 top cover Remove these four screws NE RTEL _ Slide cover forward and lift up t CS260006A Slide the top cover forward approximately 1 4 inch then lift the lid 2 to 3 inches and move it away from the chassis Contivity 2600 system board layout Figure 26 shows the Contivity 2600 s system board in particular the DIMMs option card slots and the CPU cooling fan 302283 E Rev 00 Chapter 4 Contivity 2600 Option Installation 61 Figure 26 The Contivity 2600 system board DIMMs CPU cooling fan 4 Option card slots CS260008A Warning Beware of d
15. bracket screw and remove the PCI interface card or blank PCI bracket 6 Install a new PCI interface being careful to completely press the card into the PCI connector on the mother board Replace the chassis along the guide rails in the outer casing Replace the bottom screws Installing Hardware Options for the Contivity VPN Switch 78 Chapter 6 Contivity 600 Option Installation 9 Reconnect the power cord to turn the switch back on Opening the Contivity 600 To access the system you must remove remove all cables the power cord and the bottom metal screws and pull the chassis from the rear You need a Phillips screwdriver to access the system 1 Unplug the switch s power cord from the back of the chassis and all the signal cables Turn the switch over to see the bottom of the box Using the Phillips screwdriver remove the four screws that secure the bottom to the chassis as shown in Figure 37 302283 E Rev 00 Chapter 6 Contivity 600 Option Installation 79 Figure 37 Removing the bottom screws CS60003A 4 Firmly pull the chassis towards you to loosen it from the casing You can gently shake it so that it slips outwards and into your hand or you can pull gently on the I O expansion bay Figure 38 shows how to remove the system from the chassis Installing Hardware Options for the Contivity VPN Switch 80 Chapter 6 Contivity 600 Option Installation Figure 38 Removing the system from the chass
16. the Contivity 2500 2000 4000 front bezel 44 Figure 16 Removing the Contivity 2500 2000 4000 top cover 45 Figure 17 Sample Contivity 2500 2000 system board 46 Figure 18 Sample Contivity 4000 system board 47 Figure 19 Installing 2500 2000 4000 LAN WAN option cards 48 Figure 20 Installing Contivity 2500 2000 4000 DIMMs 50 Figure 21 Removing a Contivity 4000 power supply 51 Figure 22 Removing a Contivity 4000 hard disk drive 53 Figure 23 Installing Contivity 2500 2000 4000 DIMMs 54 Figure 24 Removing the Contivity 2600 front bezel 58 Figure 25 Removing the Contivity 2600 top cover 60 Figure 26 The Contivity 2600 system board 61 Figure 27 Installing LAN WAN or hardware accelerator cards 62 Figure 28 Installing Contivity 2600 DIMMs 64 Figure 29 Removing the Contivity 1600 front bezel 68 Installing Hardware Options for the Contivity VPN Switch 12 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Removing the Contivity 1600 power cord 69 Removing the Contivity 1600 top cover
17. the power supply is on Secure the power supply screws tightly with a screwdriver Replace the front bezel 302283 E Rev 00 Chapter 1 Contivity 4600 Option Installation 27 Replacing a Contivity 4600 hard disk drive Figure 7 shows you how to replace Contivity 4600 hard disk drives for the switch Caution Hard disks are not hot swappable To replace a hard disk drive you must do the following Software First save any data that has not yet been saved to the hard disk from the disk cache 1 Use your Web browser to navigate to the switch and go to the Admin File System display 2 Click the button Prepare selected device for removal Hardware Next remove the switch s front bezel as shown in Figure 1 and then follow these steps 1 Insert and turn the hard disk drive key to the right The LED becomes a U for unlocked Note Turning the key shuts off the power to the hard disk drive gt 2 Pull the handle to remove the hard disk drive as shown in Figure 7 Installing Hardware Options for the Contivity VPN Switch 28 Chapter 1 Contivity 4600 Option Installation Figure 7 Removing a Contivity 4600 hard disk drive Insert and turn key then remove hard disk by handle CS460011A 3 Insert the replacement hard drive fully and lock it by turning the key clockwise Make sure the hard disk drive LED shows the proper drive number 4 Replace the front bezel If you need to re
18. 19 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 55 To replace or change a DIMM follow these steps Turn off the switch Remove the power cord Remove the front bezel as shown in Figure 15 Remove the top cover as shown in Figure 16 a fF O N Press down the locking levers on both sides of the next available slot to allow the new DIMM to be inserted Pull the DIMM up to remove it from the slot 7 Place a new DIMM in the slot making sure to properly position the DIMM s alignment keys Make sure the DIMM is pressed firmly into the socket 8 Pull up the locking levers on both sides of the DIMM and snap the DIMM into the slot 9 Replace the top cover 10 Replace the front bezel Memory option The Contivity 2500 2000 4000 ships with 128 Mbits of memory installed An additional 128 Mbits can be installed To increase the memory contact Nortel Networks Customer Support Installing Hardware Options for the Contivity VPN Switch 56 Chapter 3 Contivity 2500 2000 4000 Option Installation 302283 E Rev 00 57 Chapter 4 Contivity 2600 Option Installation This section describes how to install or replace hardware components for the Contivity 2600 Warning Wear an antistatic band when handling electronic AN components for the Contivity switch to avoid damaging them Note Turn off the Contivity switch and unplug it before installing LAN or WAN cards or system memory
19. EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Licensee is responsible for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files data or programs 4 Limitation of liability INNO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE EVEN IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE 5 Government licensees This provision applies to all Software and documentation acquired directly or indirectly by or on behalf of the United States Government The Software and documentation are commercial products licensed on the open market at market prices and were developed entirely at private expense and without the use of any U S Government funds The license to the U S Government is granted only with restricted rights and use duplication or disclosure by the U S Government is subject to the restrictions set forth
20. OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In addition the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure that may incorporate by reference certain limitations and notices imposed by third parties 302283 E Rev 00 USA requirements only Federal Communications Commission FCC Compliance Notice Radio Frequency Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense European requirements only EN 55 022 statement Class A This is to certify that the Nortel Networks Contivity VPN Switch is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Clas
21. Part No 302283 E Rev 00 August 2001 600 Technology Park Drive Billerica MA 01821 4130 Installing Hardware Options for the Contivity VPN Switch NORTEL NETWORKS 2 Copyright 2001 Nortel Networks All rights reserved August 2001 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Nortel Networks Inc The software described in this document is furnished under a license agreement and may be used only in accordance with the terms of that license The software license agreement is included in this document Trademarks Nortel Networks the Nortel Networks logo the Globemark Unified Networks and Contivity are trademarks of Nortel Networks Microsoft Windows and Windows NT and MS DOS are trademarks of Microsoft Corporation Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated Restricted rights legend Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 Gi of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 Notwithstanding any other license agreement that
22. ained service personnel only 1 Turn off the switch and unplug both power cords from the power source 2 Unscrew the four slotted thumb screws securing the slide out tray Pull out the tray by gripping it with the screws It will only pull out half way Remove the filler panel screw and pull out the slot filler panel Slide the option card into the intended slot Make sure the card seats firmly and evenly into the card slot If the card is not seated properly it will not work Populate the slots from Slot 1 to Slot 6 in that order Secure the option card in the tray with the slot filler panel screw Push in the tray by gripping it with the screws Tighten the four slotted thumb screws securing the slide out tray 7 Plug in both power cords to the power source and turn on the switch Caution Be careful when inserting option cards into the Contivity 4500 because the slide out tray is not fully supported once pulled out You should support the back of the tray with your hand while inserting an option card 302283 E Rev 00 Chapter 2 Contivity 4500 Option Installation 37 Figure 11 shows you how to install LAN WAN or hardware accelerator option cards into the Contivity 4500 You can use the 6 slots for any mix of LAN and WAN or hardware accelerator cards however you must populate the slots from bottom to top in that order Figure 11 Installing 4500 LAN WAN and hardware accelerator option cards
23. al nonexclusive nontransferable license a to use the Software either on a single computer or if applicable on a single authorized device identified by host ID for which it was originally acquired b to copy the Software solely for backup purposes in support of authorized use of the Software and c to use and copy the associated user manual solely in support of authorized use of the Software by Licensee This license applies to the Software only and does not extend to Nortel Networks Agent software or other Nortel Networks software products Nortel Networks Agent software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel Networks Inc Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software 2 Restrictions on use reservation of rights The Software and user manuals are protected under copyright laws Nortel Networks and or its licensors retain all title and ownership in both the Software and user manuals including any revisions made by Nortel Networks or its licensors The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals Licensee may not modify translate decompile disassemble use for any competitive analysis reverse engineer distribute or create derivative works from the Software or user manuals or any copy in whole or in part Except as express
24. anger if battery is incorrectly replaced Replace with the same or an equivalent battery only as recommended by the manufacturer s instructions Danger In spite of the above warning which is mandated for regulatory approval you should not change the battery If you suspect a dead battery contact Nortel Networks Customer Support Installing Hardware Options for the Contivity VPN Switch 62 Chapter 4 Contivity 2600 Option Installation Installing LAN WAN and hardware accelerator option cards Figure 27 shows you how to install LAN WAN or hardware accelerator option cards into the switch You can use Slots 1 to 4 for any mix of LAN and WAN cards Figure 27 Installing LAN WAN or hardware accelerator cards Rear of Unit 9 ee CCE 7 Option Card Slots Filler Panel a Option Card Motherboard CS2600017A To remove the front bezel and cover you need a Phillips screwdriver 1 Power off the switch 2 Remove the power cord 302283 E Rev 00 Chapter 4 Contivity 2600 Option Installation 63 Remove the front bezel as shown in Figure 24 Remove the top cover as shown in Figure 25 Remove the filler panel screw and pull out the filler panel as shown in Figure 27 Caution Be careful when inserting option cards into the Contivity 2600 as the slide out tray is not fully supported once pulled out You should support the back of the tray with your hand whi
25. ative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Notice For equipment using loopstart lines please note that the Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 The REN is located on the FCC Rules Part 68 label located on the bracket of the module or on the back of the unit Canada CS 03 r gles et r glements Avis L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme aux normes de protection d exploitation et de s curit des r seaux de t l communications comme le
26. ause the ball stud and sockets are new After a few times removal is easier Sliding the top cover back is optional it allows you to get a better grip on the front bezel for removal Remove the switch s front bezel as follows 1 Optionally remove the three screws at the top rear of the chassis then slide the top cover back 2 Slide your fingers between the front bezel and the switch 3 Pull forward firmly 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 45 Removing the Contivity 2500 2000 4000 top cover Figure 16 shows you how to remove the top cover from the Contivity 2500 2000 4000 You must remove the cover to e Install LAN WAN or hardware accelerator cards e Install additional memory Figure 16 Removing the Contivity 2500 2000 4000 top cover 1 Remove the three screws fram top of cover 2 Lift rear of cover up a and pull away from unit To remove the Contivity 2500 2000 4000 top cover 1 Tum off the switch s power and unplug it 2 Remove the three screws at the top rear of the chassis 3 Slide the top cover back and move it away from the chassis Installing Hardware Options for the Contivity VPN Switch 46 Chapter 3 Contivity 2500 2000 4000 Option Installation Contivity 2500 2000 4000 system board layout Figure 17 shows the Contivity 2500 200 system board in particular the DIMMs option card slots and the CPU cooling fan The Contivity 4000 system board is
27. ay and tighten the thumb screws Caution Be careful when inserting option cards into the Contivity 4500 because the slide out tray is not fully supported once pulled out You should support the back of the tray with your hand while inserting an option card Installing Hardware Options for the Contivity VPN Switch 40 Chapter 2 Contivity 4500 Option Installation Replacing a Contivity 4500 power supply Figure 13 shows you how to replace a hot swappable power supply for the Contivity 4500 Figure 13 Removing a Contivity 4500 power supply CS460010A To remove the power supply 1 Remove the front bezel as shown in Figure 8 2 Use a flat head screwdriver to unscrew the top and bottom power supply screws 3 Grab the handle and pull the power supply firmly until the device disengages Avoid the sharp sheet metal edges 302283 E Rev 00 Chapter 2 Contivity 4500 Option Installation 41 4 Insert the new power supply Make sure the power supply seats firmly in its socket and is locked in Be sure the green power LED on the front of the power supply is on Secure the power supply screws tightly with a screwdriver Replace the front bezel Replacing a Contivity 4500 hard disk drive Warning Contivity 4500 hard disks are not hot swappable When swapping a disk drive you must first perform the steps listed below to ready the switch for the swap This process is referred to as warm swapping
28. ce If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC 4 Ifyou experience trouble with the unit please contact the Nortel Networks Technical Solutions Center in your area for service or repairs Repairs should be performed only by service personnel authorized by Nortel Networks North America 800 4NORTEL or 800 466 7835 EMEA 33 4 92 966 968 Asia Pacific 61 2 9927 8800 China 800 810 5000 5 You are required to notify the telephone company when you disconnect the unit from the network Nortel Networks Inc software license agreement NOTICE Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre enabled software each of which is referred to as Software in this Agreement BY COPYING OR USING THE SOFTWARE YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE If you do not accept these terms and conditions return the product unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License grant Nortel Networks Inc Nortel Networks grants the end user of the Software Licensee a person
29. dia on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee Nortel Networks will replace defective media at no charge if it is returned to Nortel Networks during the warranty period along with proof of the date of shipment This warranty does not apply if the media has been damaged as a result of accident misuse or abuse The Licensee assumes all responsibility for selection of the Software to achieve Licensee s intended results and for the installation use and results obtained from the Software Nortel Networks does not warrant a that the functions contained in the software will meet the Licensee s requirements b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Nortel Networks is not obligated to remedy any Software defect that cannot be reproduced with the latest Software release These warranties do not apply to the Software if it has been i altered except by Nortel Networks or in accordance with its instructions ii used in conjunction with another vendor s product resulting in the defect or iii damaged by improper environment abuse misuse accident or negligence THE FOREGOING WARRANTIES AND LIMITATIONS ARE
30. drives you must remove the front bezel and then remove the switch s top cover You may find it easier to work on the system when it has been removed from the rack Installing Hardware Options for the Contivity VPN Switch 68 Chapter 5 Contivity 1600 Option Installation Removing the Contivity 1600 front bezel You must remove the bezel to insert the recovery diskette Note that you do not need to turn off the Contivity switch if you are only removing the front bezel Figure 29 shows you how to remove the front bezel from the Contivity switch Warning When handling the Contivity switch outside of the A rack mount shelf do not use the part labeled with the Nortel Networks logo and the LEDs as a handle Figure 29 Removing the Contivity 1600 front bezel CS160014A Note that the first few times you remove the front bezel it will be rather difficult to remove This is because the ball studs and socket clips are new After a few times removal is easier To remove the front bezel you need a Phillips screwdriver 1 Turn each of the two screws on the front bezel a quarter turn counter clockwise 2 Grip the two handles and firmly pull the bezel towards you to unsnap it from the chassis 302283 E Rev 00 Chapter 5 Contivity 1600 Option Installation 69 Removing the Contivity 1600 top cover To install LAN or WAN cards or to install additional memory you must remove the Contivity 1600 s front beze
31. e inserted Pull the DIMM up to remove it from the slot 7 Place a new DIMM in the slot making sure to properly position the DIMM s alignment keys Make sure the DIMM is pressed firmly into the socket 8 Pull up the locking levers on both sides of the DIMM and snap the DIMM into the slot 9 Replace the top cover 10 Replace the front bezel Memory option The Contivity 2600 ships with 128 Mbits of memory installed An additional 128 Mbits can be installed To increase the memory contact Nortel Networks Customer Support Installing Hardware Options for the Contivity VPN Switch 66 Chapter 4 Contivity 2600 Option Installation 302283 E Rev 00 67 Chapter 5 Contivity 1600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations including installing LAN and WAN cards and how to add memory for the Contivity 1600 Warning Wear an antistatic band when handling electronic A components for the Contivity switch to avoid damaging them Note Turn off the Contivity switch and unplug it before installing LAN or WAN cards or system memory Opening the Contivity 1600 To access the Contivity 1600 s diskette drive for system recovery operations you must first remove the switch s front bezel To install LAN or WAN cards install hardware accelerator PCI cards install additional memory replace power supplies or replace hard disk
32. eats firmly and evenly in the card slot If the card is not seated properly it will not work Populate the slots from Slot 1 to Slot 6 top to bottom in that order as shown in Figure 4 Figure 4 Installing Contivity 4600 LAN WAN and hardware accelerator cards CS460014A 5 Secure the option card in the tray with the slot filler panel screw 6 Push in the tray by gripping it with the screws Tighten the four slotted thumb screws securing the slide out tray Installing Hardware Options for the Contivity VPN Switch 24 Chapter 1 Contivity 4600 Option Installation 7 Plugin both power cords to the power source and turn on the switch 4600 because the slide out tray is not fully supported once pulled out Caution Be careful when inserting option cards into the Contivity You should support the back of the tray with your hand while inserting an option card Installing Contivity 4600 DIMMs Figure 6 shows you how to unlock a DIMM in the Contivity 4600 and remove or install a DIMM Install a DIMM in the next available slot for example if the DIMM 1 slot is populated then add the next DIMM to the DIMM 2 slot To install a DIMM in the Contivity 4600 follow these steps 1 2 Turn off the switch and unplug both power cords from the power source Unscrew the four slotted thumb screws securing the slide out tray Pull out the tray by gripping it with the screws It will only pull out halfway
33. eplacing a Contivity 4600 power supply 25 Replacing a Contivity 4600 hard disk drive 27 Chapter 2 Contivity 4500 Option Installation 31 Opening the Contivity 4500 ca ae ace a ou ap 6 ened OR RE 31 Removing the Contivity 4500 front bezel 31 Contivity 4500 system board layout 34 Installing Contivity 4500 LAN WAN and hardware accelerator option cards 36 Installing Gontivity 4500 DIMMS 2 sssis das eshte eeews eben bees ob bese aee ds 38 Replacing a Contivity 4500 power supply 40 Replacing a Contivity 4500 hard disk drive 41 Chapter 3 Contivity 2500 2000 4000 Option Installation 43 Opening the Contivity 2500 2000 4000 43 Removing the Contivity 2500 2000 4000 front bezel 43 Removing the Contivity 2500 2000 4000 top cover 45 Contivity 2500 2000 4000 system board layout 46 Installing Hardware Options for the Contivity VPN Switch 10 Installing Contivity 2500 2000 4000 LAN WAN option cards 48 Installing Contivity 2500 2000 4000 DIMMs 49 Replacing a Contivity 4000 power supply
34. for a Contivity 4000 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 51 Figure 21 Removing a Contivity 4000 power supply Press down on the release button and remove power supply by pulling handle To remove a Contivity 4000 power supply remove the switch s front bezel then follow these steps Press the button down to turn off the power supply Press down on the release button Pull the handle forward ER Q N a Insert the new power supply Make sure that the release button is pressed down while inserting the power supply o Make sure the power supply is locked in 6 Turn on the power supply and replace the front bezel Installing Hardware Options for the Contivity VPN Switch 52 Chapter 3 Contivity 2500 2000 4000 Option Installation Replacing a Contivity 4000 disk drive To replace a Contivity 4000 disk drive you must do the following Software First save any data that has not yet been saved to the hard disk from the disk cache 1 Use your Web browser to navigate to the switch and go to the Admin File System display 2 Click the button Prepare selected device for removal Hardware Remove the switch s front bezel as shown in Figure 15 then follow these steps 1 To remove a Contivity 4000 hard disk drive insert and turn the hard disk drive key to the right as shown in Figure 22 The LED becomes a U for unlocked NOTE Turning the key shuts off t
35. h B8ZF coding 04DU9 1ZN 1 544 MB ANSI ESF and ZBTSI without line power The telephone company will select the code it has available The Service Order Code s SOC 6 0Y The required Universal Service Order Code USOC jack RJ48C e When you request ISDN U Interface Service you must provide the telephone company with The Facility Interface Code 02IS5 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ49C e When you request ISDN S T Interface Service you must provide the telephone company with The Service Order Code s SOC 6 0P The make model number and FCC Registration number of the NT1 Note ISDN S T cannot be directly connected to the network e When you request Primary Rate ISDN Service you must provide the telephone company with The Facility Interface Code 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding The Service Order Code s SOC 6 0Y The required Universal Service Order Code USOC jack RJ48C 302283 E Rev 00 2 Your telephone company may make changes to its facilities equipment operations or procedures that could affect the proper functioning of your equipment The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service 3 If the unit causes harm to the telephone network the telephone company may temporarily discontinue your servi
36. he power to the hard disk drive gt 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 53 Figure 22 Removing a Contivity 4000 hard disk drive Drive 0 Drive 1 A Insert and turn key then remove hard disk by handle Pull the handle to remove the hard disk drive Insert the replacement hard drive fully and lock it by turning the key clockwise Make sure the hard disk drive LED shows the proper drive number Replace the front bezel Reload the software on the disk Refer to Using the Recovery Diskette in Installing the Contivity 4600 for more information on using the recovery diskette Installing Hardware Options for the Contivity VPN Switch 54 Chapter 3 Contivity 2500 2000 4000 Option Installation Software Enable the switch by following these steps 1 Use your Web browser to navigate to the switch and go to the Admin gt File System display 2 Click on the drive and click the Enable button Installing Contivity 2500 2000 4000 DIMMs Figure 23 shows you how to unlock a Dual Inline Memory Module DIMM and remove or install the DIMM in the next available slot for example if the DIMM 1 slot is populated add the next DIMM to the DIMM 2 slot Figure 23 Installing Contivity 2500 2000 4000 DIMMs Alignment keys To remove DIMMs pull back locking sep and pull out DIMM Locking lever To install DIMMs pull back locking levers 2600194 and push in DIMM CS2600
37. in subparagraph c 1 of the Commercial Computer Software Restricted Rights clause of FAR 52 227 19 and the limitations set out in this license for civilian agencies and subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause of DFARS 252 227 7013 for agencies of the Department of Defense or their successors whichever is applicable 6 Use of software in the European Community This provision applies to all Software acquired for use within the European Community If Licensee uses the Software within a country in the European Community the Software Directive enacted by the Council of European Communities Directive dated 14 May 1991 will apply to the examination of the Software to facilitate interoperability Licensee agrees to notify Nortel Networks of any such intended examination of the Software and may procure support and assistance from Nortel Networks 7 Term and termination This license is effective until terminated however all of the restrictions with respect to Nortel Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Nortel Networks copyright those restrictions relating to use and disclosure of Nortel Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license Upon terminatio
38. is CS60004A Contivity 600 system board layout Figure 39 shows the Contivity 600 system board in particular the option card slot DIMM memory and the CPU cooling fan 302283 E Rev 00 Chapter 6 Contivity 600 Option Installation 81 Figure 39 Contivity 600 system board Option card slot CPU cooling fan DIMM slot CS60005A Warning Beware of danger if the battery is incorrectly replaced A Replace with the same or an equivalent battery only as recommended by the manufacturer s instructions Danger In spite of the above warning which is mandated for AN regulatory approval you should not change the battery If you suspect a dead battery contact Nortel Networks Customer Support Installing Contivity 600 option cards This section shows you how to install LAN or WAN option cards in the Contivity 600 Installing Hardware Options for the Contivity VPN Switch 82 Chapter 6 Contivity 600 Option Installation 1 Remove the blank PCI bracket by inserting a Phillips screw driver into the slot at the right of the blank PCI bracket and rotating the screw counter clockwise 2 Lift out the blank PCI bracket and slide the replacement card into the intended slot Note Be careful not to bend the copper fingers in the slot Make sure the card seats firmly and evenly in the card slot and that the left tabbed end of the card is seated in its slot If the card is not seated pro
39. l and then the switch s top cover To remove the cover you need a Phillips screwdriver Note You do need to turn off the Contivity switch to remove the top 1 Turn off the switch s power and remove the power cord Figure 30 shows how to remove the power cord from the Contivity switch Figure 30 Removing the Contivity 1600 power cord 100 2240VAC 2 1A 50 60Hz Al Power cable CS160009A 2 Turn each of the two screws on the front bezel a quarter turn counter clockwise 3 Grip the two handles and firmly pull the bezel towards you to unsnap it from the chassis Do not use the part labeled with the Nortel Networks logo and the LEDs as a handle Installing Hardware Options for the Contivity VPN Switch 70 Chapter 5 Contivity 1600 Option Installation 4 Use the Phillips screwdriver to remove the four screws that secure the cover to the chassis as shown in Figure 31 Figure 31 Removing the Contivity 1600 top cover r Slide cover forward and lift up C CS160003A 5 Slide the top cover forward approximately 1 4 inch then lift the lid 2 to 3 inches and move it away from the chassis 302283 E Rev 00 Chapter 5 Contivity 1600 Option Installation 71 Contivity 1600 system board layout Figure 32 shows the Contivity 1600 s system board in particular the DIMMs option card slots and the CPU cooling fan Figure 32 Conti
40. le inserting an option card 6 Slide the option card into the intended slot Make sure the card seats firmly and evenly into the card slot If the card is not seated properly it will not work Replace the card and screw Replace the top cover Replace the front bezel Caution Be careful when inserting option cards into the Contivity 2600 as the slide out tray is not fully supported once pulled out You should support the back of the tray with your hand while inserting an option card Installing Hardware Options for the Contivity VPN Switch 64 Chapter 4 Contivity 2600 Option Installation Installing Contivity 2600 DIMMs Figure 28 shows you how to unlock a Dual Inline Memory Module DIMM and remove or install the DIMM in the next available slot for example if the DIMM 1 slot is populated add the next DIMM to the DIMM 2 slot Figure 28 Installing Contivity 2600 DIMMs Alignment keys To remove DIMMs pull back locking ve i and pull out DIMM Locking lever To install DIMMs pull back locking levers 2600194 and push in DIMM CS260019 302283 E Rev 00 Chapter 4 Contivity 2600 Option Installation 65 To replace or change a DIMM follow these steps Turn off the switch Remove the power cord Remove the front bezel as shown in Figure 24 Remove the top cover as shown in Figure 25 a fF O N Press down the locking levers on both sides of the next available slot to allow the new DIMM to b
41. load the software on the disk see the information on using the recovery diskette in the Installing the Contivity 4600 book 302283 E Rev 00 Chapter 1 Contivity 4600 Option Installation 29 Software Enable the switch by following these steps 1 Use your Web browser to navigate to the switch and go to the Admin File System display 2 Click on the drive and click the Enable button Installing Hardware Options for the Contivity VPN Switch 30 Chapter 1 Contivity 4600 Option Installation 302283 E Rev 00 31 Chapter 2 Contivity 4500 Option Installation This section describes how to install or replace hardware components for the Contivity 4500 Warning Wear an antistatic band when handling electronic AN components for the Contivity switch to avoid damaging them Note Turn off the Contivity switch and unplug it before installing LAN or WAN cards or system memory Opening the Contivity 4500 To replace power supplies replace hard disk drives or access the Contivity 4500 s diskette drive for system recovery operations you must remove the switch s front bezel To install LAN or WAN cards or install additional memory you must remove the front bezel and then remove the switch s top cover as well Removing the Contivity 4500 front bezel Note Removing the front bezel on the Contivity 4500 system activates the chassis intrusion alarm only if the switch is turned on This intrusion is repo
42. ly provided in this Agreement Licensee may not copy or transfer the Software or user manuals in whole or in part The Software and user manuals embody Nortel Networks and its licensors confidential and proprietary intellectual property Licensee shall not sublicense assign or otherwise disclose to any third party the Software or any information about the operation design performance or implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors however Licensee may grant permission to its consultants subcontractors and agents to use the Software at Licensee s facility provided they have agreed to use the Software only in accordance with the terms of this license 3 Limited warranty Nortel Networks warrants each item of Software as delivered by Nortel Networks and properly installed and operated on Nortel Networks hardware or other equipment it is originally licensed for to function substantially as described in its accompanying user manual during its warranty period which begins on the date Software is first shipped to Licensee If any item of Software fails to so function during its warranty period as the sole Installing Hardware Options for the Contivity VPN Switch 8 remedy Nortel Networks will at its discretion provide a suitable fix patch or workaround for the problem that may be included in a future Software release Nortel Networks further warrants to Licensee that the me
43. may pertain to or accompany the delivery of this computer software the rights of the United States Government regarding its use reproduction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of conditions In the interest of improving internal design operational function and or reliability Nortel Networks Inc reserves the right to make changes to the products described in this document without notice Nortel Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Portions of the code in this software product may be Copyright 1988 Regents of the University of California All rights reserved Redistribution and use in source and binary forms of such portions are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation advertising materials and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California Berkeley The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES
44. n for any reason Licensee will immediately destroy or return to Nortel Networks the Software user manuals and all copies Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license 8 Export and re export Licensee agrees not to export directly or indirectly the Software or related technical data or information without first obtaining any required export licenses or other governmental approvals Without limiting the foregoing Licensee on behalf of itself and its subsidiaries and affiliates agrees that it will not without first obtaining all 302283 E Rev 00 Contents PYOTACG oii cei eas dd das goes ne ede SEE DRASS SRE eee ee EERE 13 Related puDICaUONS sere one CS nid ie al Sh ete ali races sede aed deu 14 Ne CONVO OE ogc uGig dc aeeksayere ae ina SCRELERREE ERE EK ORE RS 14 20 DE LIL 52446525 Se FEAL SESE ST E PE E TERA RE RRR REED TREE MBAS S 16 Hardcopy technical manuals csc ee aed ook am ee eee eee 64 17 How t get help aus eee eee e We Re bed Ree PREM EERE ER PRE ERR ERR E RE ES 17 Chapter 1 Contivity 4600 Option Installation 19 Opening the Contivity 4600 occ ke ane eu ie date doi eR A AU de RE E 19 Contivity 4600 system board layout 22 Installing Contivity 4600 LAN WAN and hardware accelerator cards 23 Installing Contivity 4600 DIMMS 24 R
45. ng of internal components or assemblies with the power connected could cause severe injury Figure 3 shows a sample Contivity 4600 system board including the Dual Inline Memory Modules DIMMs and peripheral component interconnect PCI slots Figure 3 Sample Contivity 4600 system board aonn Tocoooo son ooo ono ooN ooo ooo ooo A cee Tonoa oroo aonn Todoooo eon ooo ono ooN oo ooo ooo SS aonana monona SS l Sl aonn TodooooTon ooo ono ooo eoo ooo ooo E Doa TooooHo oo ooo OHO oONHooOMooooe Tony a k If oogooo DODOUOODONDOONNODONNUNONUNEE Tanne TocooooeoA ooo ono oo ooo Ooo ooo A Donnan nomnoman amn mn a Sonano aa J Cod DIMM slots CS460007A 302283 E Rev 00 Chapter 1 Contivity 4600 Option Installation 23 Installing Contivity 4600 LAN WAN and hardware accelerator cards This section describes how you install option cards in the switch option card slide out tray The following procedure is for Nortel Networks trained service personnel only 1 Turn off the switch and unplug both power cords from the power source 2 Unscrew the four slotted thumb screws securing the slide out tray Pull out the tray by gripping it with the screws It will only pull out halfway Remove the filler panel screw and pull out the slot filler panel Slide the option card into the intended slot Make sure the card s
46. nications Radio Interference Regulations This digital apparatus Contivity 1600 and Contivity 2600 does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Classe B Cet appareil num rique Contivity 1600 and Contivity 2600 respecte les limites de bruits radio lectriques visant les appareils num riques de classe B prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Canada CS 03 rules and regulations Notice The Industry Canada label identifies certified equipment This certification means that the equipment meets telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent the degradation of service in some situations Repairs to certified equipment should be coordinated by a represent
47. ns of the R amp TTE Directive 1999 5 EC Installing Hardware Options for the Contivity VPN Switch 4 Japan Nippon requirements only Voluntary Control Council for Interference VCCI statement Class A CORB AURRE SERRE ERER VCCI ORE KED VSGRZATRRHRE CT TOHE AKERE A LB BES ARIOTCEMHVES TCOMSIITHAEMBIEMRERS ZKLDBRENSZTEMBVET Voluntary Control Council for Interference VCCI statement Class B Contivity 1600 and 2600 CORB WRUBRESERMSAERA BRS VCCI ORE KEDY ZFA BARRHRETT CORB KERTET ATE EBELTOFT CORBMIVAPCTV EV a VRR T BASNSL SaMBeslSRCTCEMHVET RRS ASI 2 TIELUBROUBUELTFEL Taiwan requirements Bureau of Standards Metrology and Inspection BSMI statement HERRIE GE PRNRRES ERER RP AM T S RH ATE CRA AESH ERAN REM BNR Canada requirements only Canadian Department of Communications Radio Interference Regulations This digital apparatus Contivity VPN Switch does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique Contivity VPN Switch respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada 302283 E Rev 00 Canadian Department of Commu
48. oose the text to enter based on the description inside the brackets Do not type the brackets when entering the command Example If the command syntax is ping lt ip address gt you enter ping 192 32 10 12 bold Courier text Indicates command names options and text that you need to enter Example Use the dinfo command Example Enter show ip alerts routes 302283 E Rev 00 braces brackets ellipsis points italic text plain Courier text separator gt Preface 15 Indicate required elements in syntax descriptions where there is more than one option You must choose only one of the options Do not type the braces when entering the command Example If the command syntax is show ip alerts routes you must enter either show ip alertsorshow ip routes but not both Indicate optional elements in syntax descriptions Do not type the brackets when entering the command Example If the command syntax is show ip interface alerts you can enter either show ip interface or show ip interface alerts Indicate that you repeat the last element of the command as needed Example If the command syntax is ethernet 2 1 lt parameter gt lt value gt you enter ethernet 2 1 and as many parameter value pairs as needed Indicates new terms book titles and variables in command syntax descriptions Where a variable is two or more words the words are connected by an underscore
49. perly it will not work 3 Replace the screw at the right end of the PCI bracket 4 Slide the system into the chassis as shown in Figure 40 Figure 40 Replacing the system into the chassis CS60004A 5 Replace the four Phillips head screws to secure the bottom panel 6 Reconnect the signal cables 7 Reconnect the power cord to restart the Contivity 600 302283 E Rev 00 Chapter 6 Contivity 600 Option Installation 83 Memory option The Contivity 600 ships with 64 Mbits of memory installed No additional memory can be installed Installing Hardware Options for the Contivity VPN Switch 84 Chapter 6 Contivity 600 Option Installation 302283 E Rev 00 85 Index A M acronyms 16 memory additional memory size 55 65 76 83 installing 45 antistatic 19 34 O C conventions 14 conventions text 14 customer support 17 D DIMMs 16 22 35 installing 24 38 49 54 64 75 documentation map 14 DSU CSU required 16 F front bezel removing 19 20 31 32 43 44 58 68 H hard drives 33 L LAN cards installing 37 45 48 62 72 81 option cards slots 22 35 P power supplies 33 replacinga 40 power supply replacinga 50 product support 17 publications hard copy 17 R recovery diskette drive 33 58 68 78 S safety 19 34 power off 37 39 48 55 62 65 72 76 81 support Nortel Networks 17 system board illustration 22 35 T technical publication
50. personnel should change existing hardware configurations Improper handling of internal components or assemblies with the power connected could cause severe injury Warning Note that some models must be returned to Nortel Networks AN Manufacturing via your Customer Service Representative for repair Do not attempt to make any changes to these models because untrained individuals could be harmed you could invalidate your warranty or you could possibly cause irreparable damage to the equipment Installing Hardware Options for the Contivity VPN Switch 14 Preface This guide refers to the Contivity 4600 4500 4000 2600 2000 1600 and 600 as the switch It assumes that you are familiar with Web browsers and their general operation Related publications The following list shows the associated documentation that you will need to configure and manage the switch Contivity VPN Switch Release Notes provide the latest information including known problems workarounds and special considerations Configuring the Contivity VPN Switch included on the CD provides complete detailson how to configure monitor and troubleshoot the switch Getting Started with the Contivity xxxx or Installing the Contivity xxxx included on the CD provides complete details to help you set up and get started using your switch Text conventions This guide uses the following text conventions angle brackets lt gt Indicate that you ch
51. prescrivent les documents concernant les exigences techniques relatives au mat riel terminal Le Minist re n assure toutefois pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de t l communication Le mat riel doit galement tre install en suivant une m thode accept e de raccordement L abonn ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp che pas la d gradation du service dans certaines situations Les r parations de mat riel homologu doivent tre coordonn es par un repr sentant d sign par le fournisseur L entreprise de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Installing Hardware Options for the Contivity VPN Switch Pour sa propre protection l utilisateur doit s assurer que tous les fils de mise la terre de la source d nergie lectrique des lignes t l phoniques et des canalisations d eau m talliques s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales Avertissement L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des ins
52. rds Rear of Unit 9 ee CCE 7 Option Card Slots Filler Panel a Option Card Motherboard CS2600017A 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 49 To install an option card 1 Turn off the switch and remove the power cord Remove the front bezel and top cover as shown in Figure 16 Remove the filler panel screw and pull out the filler panel as shown in Figure 19 4 Slide the option card into the intended slot Make sure the card seats firmly and evenly in the card slot If the card is not seated properly it will not work Replace the card and screw Replace the and top cover and front bezel Turn the switch on Installing Contivity 2500 2000 4000 DIMMs Figure 20 shows you how to unlock a Dual Inline Memory Module DIMM in a Contivity 2500 2000 4000 and remove or install a DIMM Install a DIMM in the next available slot for example if the DIMM 1 slot is populated add the next DIMM to the DIMM 2 slot Installing Hardware Options for the Contivity VPN Switch 50 Chapter 3 Contivity 2500 2000 4000 Option Installation Figure 20 Installing Contivity 2500 2000 4000 DIMMs Alignment keys To remove DIMMs pull back locking i a and pull out DIMM Locking lever To install DIMMs pull back locking levers and push in DIMM RESTES Replacing a Contivity 4000 power supply Figure 21 shows you how to replace a power supply
53. reface 17 URL Uniform Resource Locator VPN Virtual private network WAN Wide area network Hard copy technical manuals You can print selected technical manuals and release notes free directly from the Internet Go to the www nortelnetworks com documentation URL Find the product for which you need documentation Then locate the specific category and model or version for your hardware or software product Use Adobe Acrobat Reader to open the manuals and release notes search for the sections you need and print them on most standard printers Go to Adobe Systems at the www adobe com URL to download a free copy of the Adobe Acrobat Reader You can purchase selected documentation sets CDs and technical publications through the Internet at the www1 fatbrain com documentation nortel URL How to get help If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Nortel Networks service program contact one of the following Nortel Networks Technical Solutions Centers Technical Solutions Center Telephone Europe Middle East and Africa 33 4 92 966 968 800 2LANWAN or 800 252 6926 61 2 9927 8800 800 810 5000 North America Asia Pacific China gos ae ae a Installing Hardware Options for the Contivity VPN Switch 18 Preface
54. rted to the system log file The first few times you remove the front bezel it will be somewhat difficult to remove This is because the ball stud and sockets are new After a few times removal is easier Remove the switch s front bezel as follows Installing Hardware Options for the Contivity VPN Switch 32 Chapter 2 Contivity 4500 Option Installation 1 Insert a flat head screwdriver into the slots on the lower left and right sides of the chassis and pry the bezel forward Slide your fingers between the front bezel and the switch Pull the bezel forward firmly separating the ball studs on the bezel from the sockets on the chassis Figure 8 shows you how to remove the front bezel from the switch You do not need to turn off the switch to remove the front bezel Figure 8 Removing the Contivity 4500 front bezel Using a screwdriver seperate ball stud on bezel from socket on chassis 4 corners SSS Ee c gt NO RT E orks CONTIVITY Extranet Switch 45000 e CS450011A 302283 E Rev 00 Chapter 2 Contivity 4500 Option Installation 33 Remove the Contivity 4500 front bezel to e Replace a power supply e Replace a hard disk drive e Insert the recovery diskette Figure 9 shows the Contivity 4500 front components Figure 9 Contivity 4500 front components Disk drives 3 5 floppy drive
55. s 17 technical support 17 Installing Hardware Options for the Contivity VPN Switch 86 Index text conventions 14 top cover removing 45 W WAN cards installing 37 45 48 62 72 81 302283 E Rev 00
56. s A CISPR 22 Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in welchen Fallen der Benutzer f r entsprechende Gegenma nahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilisateur de prendre les mesures sp cifiques appropri es To maintain compliance with FCC radio frequency emission limits shielded cables are required to connect equipment to other Class A certified devices and the use of quadshield RG 6 U type CATV cable is required for connection to the CATV system Any changes or modifications may void the user s authorization to operate this equipment EN 55 022 statement Class B This is to certify that the Nortel Networks Contivity 1600 and 2600 are shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class B CISPR 22 Compliance is dependent upon the use of shielded Nortel Networks Contivity 1600 or 2600 EC Declaration of Conformity Tthese products conform to the provisio
57. s down the locking levers on both sides of the DIMM as shown in Figure 36 Pull the DIMM up to remove it from the slot Place a new DIMM in the slot making sure to properly position the DIMM s alignment keys Make sure the DIMM is pressed firmly into the socket Pull up the locking levers on both sides of the DIMM and snap the DIMM into the socket Replace the top cover 10 Replace the front bezel 11 Reconnect the power cord 12 Turn on the switch Memory option The Contivity 1600 ships with 64 Mbits of memory installed An additional 64 Mbits can be installed To increase the memory contact Nortel Networks Customer Support 302283 E Rev 00 77 Chapter 6 Contivity 600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations including installing LAN and WAN cards for the Contivity 600 Note The expansion slot is renamed to Slot 2 by the Contivity 600 software Warning Wear an antistatic band when handling electronic AN components for the Contivity 600 to avoid damaging them Note Unplug the power cord from the rear of the Contivity 600 before installing LAN or WAN interface cards To install LAN or WAN cards you must Remove the power cable Remove all signal cables Remove the four screws on the bottom of the switch Slide the inner chassis out of the casing a A O N Unscrew the PCI interface
58. similar but has two CPUs as shown in Figure 18 Figure 17 Sample Contivity 2500 2000 system board Factory installed DIMMs 1 4 CPU cooling fans Four option card slots only three are usable 302283 E Rev 00 Chapter 3 Contivity 2500 2000 4000 Option Installation 47 Figure 18 Sample Contivity 4000 system board Factory Installed DIMMs 1 2 or 4 Replaceable Battery T U U a Cooling Fans Option Card Slots 4 Installing Hardware Options for the Contivity VPN Switch 48 Chapter 3 Contivity 2500 2000 4000 Option Installation Installing Contivity 2500 2000 4000 LAN WAN option cards Figure 19 shows you how to install LAN or WAN option cards into a Contivity 2500 2000 4000 You can use Slots 1 to 3 for any mix of LAN and WAN cards Note that Slot 4 is not supported Figure 19 Installing 2500 2000 4000 LAN WAN option ca
59. tallations lectriques ou un lectricien selon le cas Avis Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart l indice d quivalence de la sonnerie IES assign chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent tre raccord s une interface La terminaison d une interface t l phonique peut consister en une combinaison de quelques dispositifs la seule condition que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas 5 Le REN figure sur l tiquette FCC Rules Part 68 situ e sur le support du module ou l arri re de l unit FCC Part 68 compliance statement This equipment complies with Part 68 of FCC Rules All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68 Please note the following You are required to request service from the telephone company before you connect the unit to a network When you request service you must provide the telephone company with the following data e When you request T1 Service you must provide the telephone company with The Facility Interface Code Provide the telephone company with all the codes below 04DU9 BN 1 544 MB D4 framing format 04DU9 DN 1 544 MB D4 framing format with B8ZF coding 04DU9 1KN 1 544 MB ESF framing format 04DU9 1SN 1 544 MB ESF framing format wit
60. vity 1600 system board DIMMs 1 and 2 Option card slots only two are usable Not used CS160004A Warning Beware of danger if the battery is incorrectly replaced Replace with the same or an equivalent battery only as recommended by the manufacturer s instructions Danger In spite of the above warning which is mandated for regulatory approval you should not change the battery If you suspect a dead battery contact Nortel Networks Customer Support Installing Hardware Options for the Contivity VPN Switch 72 Chapter 5 Contivity 1600 Option Installation Installing Contivity 1600 option cards This section shows you how to install LAN or WAN option cards in the Contivity 1600 1 Turn off the switch 2 Remove the power cord as shown in Figure 33 Figure 33 Removing the Contivity 1600 power cord 100 2240VAC 2 1A 50 60Hz Al Power cable CS160009A 3 Remove the front bezel as shown in Figure 29 302283 E Rev 00 Chapter 5 Contivity 1600 Option Installation 73 4 Remove the top cover as shown in Figure 31 5 Remove the filler panel screw and pull out the filler panel as shown in Figure 34 Figure 34 Installing Contivity 1600 LAN WAN option cards Screwdriver Phillips Option card slots screw slot a E OL Te a Nl Option card s I En mA Motherboard CS160020A